Labshake search
Citations for Quantifoil Micro Tools :
201 - 250 of 1446 citations since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2024Quote: ... Double application of 3 μL protein (∼0.6 mg/mL) SYM2081 complex was carried out on glow-discharged gold grids (R 0.6/1, 300 mesh, Quantifoil). The grids were blotted for 4.5 s and 3.5 s ...
-
bioRxiv - Neuroscience 2024Quote: ... Double application of 2 μL protein (∼0.9 mg/mL) SYM2081 complex was carried out on glow-discharged gold grids (1.2/1.3, 200 mesh, Quantifoil). Grids were blotted for 3 s and 10 s ...
-
bioRxiv - Biophysics 2024Quote: UltrAuFoil holey-gold 300 mesh 1.2/1.3 μm size/hole space grids (UltrAuFoil, Quantifoil) were glow discharged ...
-
bioRxiv - Biochemistry 2024Quote: UltrAuFoil R2/2 Au300 mesh grids (Quantifoil) were glow discharged for 30 seconds on each side at 25 mA using a Pelco easiGlow unit (Ted Pella ...
-
bioRxiv - Immunology 2024Quote: Neutrophils were stimulated with 100 nM LTB4 in mHBSS for 15 mins at 37 °C in 35 mm glass bottom dishes containing glow-discharged Au SiO2 R1/4 200 mesh grids (Quantifoil GmbH) precoated with 25 μg/ml fibrinogen in DPBS ...
-
bioRxiv - Microbiology 2024Quote: ... and 4 µl of the mixture was applied to a glow-discharged holey-carbon copper EM grid (R2/1 or R2/2, [Quantifoil]). The grid was automatically blotted from the backside for 4-6 s in a Mark IV Vitrobot by using a Teflon sheet on the front pad ...
-
bioRxiv - Microbiology 2024Quote: ... 3 μl of parasites were applied onto a freshly plasma-cleaned UltrAufoil R1.2/1.3 300 mesh EM grid (Quantifoil) in a humidity controlled facility ...
-
bioRxiv - Microbiology 2024Quote: ... A 4.5 µL droplet of the culture was applied to glow discharged copper grids (Quantifoil R2/2, Quantifoil Micro Tools) and blotted for 2.5 s in a 95% humidity chamber at 20 °C ...
-
bioRxiv - Biochemistry 2024Quote: ... 3 μL of hexapeptide sample were applied to glow-discharged Quantifoil R 2/2 grids (Quantifoil Micro tools GmbH, Germany), blotted for 1 second ...
-
bioRxiv - Biochemistry 2024Quote: The GPR68-Gs pH 6 complex was concentrated to 4 mg/mL and 3 µL was applied onto a glow-discharged 300 mesh 1.2/1.3 gold grid covered in a holey carbon film (Quantifoil). Excess sample was removed with a blotting time of 4 s and a blotting force of 1 at 4 °C prior to plunge freezing into liquid ethane using a Vitrobot Mark IV (Thermo Fisher) ...
-
bioRxiv - Synthetic Biology 2024Quote: ... 300 mesh (Quantifoil) at 9.0 mg/ml and 4.2 mg/ml ...
-
bioRxiv - Plant Biology 2024Quote: ... 2.5 μL of solution was applied to R1.2/1.3 Cu 400-mesh grids (Quantifoil, Germany) that had been glow-discharged for 60 seconds with a current of 15 mA in a PELCO easiGlow system ...
-
bioRxiv - Molecular Biology 2023Quote: Cells were cultured directly on gold grids (R2/1, carbon film, Quantifoil) after being glow-discharged using a Pelco GD system ...
-
bioRxiv - Molecular Biology 2023Quote: ... to prepare thin vitreous samples on Quantifoil type R 1.2/1.3 holey-carbon grids (Quantifoil Microtools). The grids were made hydrophilic ...
-
bioRxiv - Molecular Biology 2023Quote: Samples were prepared by glow discharging 1.2/1.3 300 mesh UltrAuFoil (QuantiFoil Micro Tools GmbH ...
-
bioRxiv - Microbiology 2023Quote: ... Phage particles were negatively stained for 20 seconds with 2% uranyl acetate on carbon-coated copper grids (Quantifoil) and observed at 100 kV on a Hitachi HT 7700 equipped with an AMT XR81B Peltier cooled CCD camera (8M pixel ...
-
bioRxiv - Systems Biology 2023Quote: ... 300 mesh TEM grids with a holey carbon substrate of 1.2/1.3 µm spacing (Quantifoil). The grids were blotted with #4 filter papers (Whatman ...
-
bioRxiv - Immunology 2023Quote: UltrAuFoil R1.2/1.3 grids (Au, 300-mesh; Quantifoil Micro Tools GmbH) were plasma discharged using a PELCO easiGlow (Ted Pella Inc. ...
-
bioRxiv - Immunology 2023Quote: ... 3 μL of the purified complex were loaded onto a glow-discharged holey grid (Quantifoil Au 300 mesh R1.2/1.3), and subsequently were plunge-frozen in liquid ethane using Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Immunology 2023Quote: ... the 300 mesh Au R1.2/1.3 grids (Quantifoil) were used ...
-
bioRxiv - Molecular Biology 2023Quote: ... 3.5 μL sample was applied to a glow-discharged 300 mesh gold grid (Quantifoil R1.2/1.3). The sample was incubated with the grid for 60 seconds at 8 □ and 100% humidity to maximize the absorption ...
-
bioRxiv - Biochemistry 2023Quote: ... Four microliters of purified Cx36 proteins (4-6 mg/ml) were applied onto a negatively glow-discharged holey carbon grid (Quantifoil R1.2/1.3 Cu 300 mesh). For samples involving Cx36-WT ...
-
bioRxiv - Biochemistry 2023Quote: The affinity-purified RNCs were vitrified on UltrAuFoil R 1.2/1.3 300-mesh grids (Quantifoil) coated with graphene oxide (Sigma-Aldrich) ...
-
bioRxiv - Biochemistry 2023Quote: ... UltrAufoil Au 200 mesh R2/2 grids (Quantifoil) EM grids were glow-discharged on each side for 90 s at 30 sccm ...
-
bioRxiv - Biophysics 2023Quote: UltrAuFoil holey-gold 300 mesh 1.2/1.3 μm size/hole space grids (UltrAuFoil, Quantifoil) were glow discharged ...
-
bioRxiv - Biophysics 2023Quote: Three microliters of the purified CLC-2 or CLC-2/AK-42 mixture was applied to glow-discharged copper Quantifoil R1.2/1.3 or R2/1 holey carbon grids (Quantifoil). Grids were incubated for 15 s ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... UltrAuFoil Au R1.2/1.3 300-mesh grids (Quantifoil) was glow discharged in a Tergeo-EM plasma cleaner ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 μL TRPV1-nanodiscs was applied to glow-discharged Quantifoil R1.2/1.3 Au 300 mesh grids covered in holey carbon film (Quantifoil Micro Tools GmbH) and blotted with Whatman 1 filter paper on a Vitrobot Mark IV (FEI company ...
-
bioRxiv - Biochemistry 2023Quote: ... It was subsequently prepared on UltraAuFoil R1.2/1.3 gold support grids (Quantifoil). 3 μL of sample was applied to glow-discharged grids ...
-
bioRxiv - Biochemistry 2023Quote: ... Quantifoil® R1.2/1.3 Au 300 mesh grids were purchased from Quantifoil Micro Tools GmbH (Großlöbichau ...
-
bioRxiv - Molecular Biology 2023Quote: ... 4 μL of sample were applied for 30 s to 1.2/1.3 holey carbon on 300 mesh copper grids (Quantifoil), followed by 5 s blotting with blot force 20 and plunge freezing in liquid ethane with a Vitrobot IV (FEI ...
-
bioRxiv - Molecular Biology 2023Quote: ... A concentrated sample (2.8 μl) was applied to holey carbon grids (Au R1.2/1.3, 300 mesh, Quantifoil, Jena, Germany) previously glow-discharged for 30 s at 5 mA ...
-
bioRxiv - Biochemistry 2023Quote: ... Cryo-EM specimens were prepared on Au300 R1.2/1.3 (Quantifoil) that were glow-discharged for 45s at 25 mA (PELCO easy glow) ...
-
bioRxiv - Biochemistry 2023Quote: The final high resolution data set was collected across 2 grids (Quantifoil 1.2/1.3 200 mesh) prepared with 1.8 mg mL-1 trimeric complex and 0.5 and 0.1 X CMC CHAPS ...
-
bioRxiv - Molecular Biology 2023Quote: Minicells were vitrified on QUANTIFOIL® R0.6/1 or R1.2/1.3 holey carbon grids (Quantifoil Micro Tools) using a Vitrobot Mark IV (Thermo Fisher Scientific).
-
bioRxiv - Microbiology 2023Quote: ... The samples were applied to a Quantifoil R2/2 Cu 300 mesh grid (Quantifoil Micro Tools GmbH), which had been freshly glow-discharged for 60 s at 10 mA using PIB-10 (Vacuum Device) ...
-
bioRxiv - Cell Biology 2023Quote: Grids (Quantifoil R1.2/1.3) were glow discharged in a Pelco easyGlow for 60s ...
-
bioRxiv - Cell Biology 2023Quote: ... the cells were seeded on Quantifoil R 2/2 200 gold mesh grids (Quantifoil, Großlöbichau, Germany) coated with 100 mg/mL poly-L-lysine and 50 µg/mL collagen I ...
-
bioRxiv - Cell Biology 2023Quote: ... Two μl of the diluted complex were applied to freshly glow-discharged R 2/2 holey carbon grids (Quantifoil), which were blotted with a force of 6 for 5 seconds and immediately vitrified by plunge-freezing in liquid ethane using a Vitrobot Mark IV (ThermoFisher ...
-
bioRxiv - Cell Biology 2023Quote: ... 150 or 200 mesh gold holey carbon grids (R 2/2, #N1-C16nAu15-01 and #N1-C16nAu20-01, respectively) were purchased from Quantifoil Micro Tools and glow discharged for 2 min in an ELMO glow discharge unit (Agar Scientific ...
-
bioRxiv - Cell Biology 2023Quote: ... or without exogenous substrate was applied to glow-discharged Au 400 mesh QUANTIFOIL R1.2/1.3 holey carbon grids (Quantifoil) and then plunged into liquid nitrogen-cooled liquid ethane with an FEI Vitrobot Mark IV (FEI Thermo Fisher) ...
-
bioRxiv - Cell Biology 2023Quote: ... a 200-mesh gold grid with Silicon Dioxide R2/1 film (Quantifoil) was coated with Matrigel as reported in the protocol ...
-
bioRxiv - Molecular Biology 2023Quote: ... applied to a glow-discharged R 1.2/1.3 300 mesh UltrAuFoil gold grid (Quantifoil Micro Tools GmbH) and plunge-frozen in liquid ethane using a Vitrobot Mark IV (Thermo Scientific ...
-
bioRxiv - Biophysics 2023Quote: ... R1.2/1.3 Mo400 grids (Quantifoil, Jena, Germany) were glow discharged and used within an hour ...
-
bioRxiv - Bioengineering 2023Quote: ... 3.0 µl aliquots at a concentration of 0.87 or 1.0 mg/ml of the spikeD614G-binder sample or the spikeOmicron-binder sample were applied onto glow-discharged carbon-coated copper grids (Quantifoil R2/1, 400 mesh), blotted for 4.0-8.0 s ...
-
bioRxiv - Neuroscience 2023Quote: ... UltrAuFoil grids 300 mesh 1.2/1.3 or 0.6/1.0 from Quantifoil were glow discharged in a PELCO easiGlow for 25mA/15s ...
-
bioRxiv - Cell Biology 2023Quote: Cells were blotted on EM grids (R 2/1 holey carbon 200 films on Cu 200 mesh, Quantifoil Micro Tools). The grids were first glow-discharged and 4 µl of trypanosome wild-type culture (2-4 · 107 cells/ml ...
-
bioRxiv - Cell Biology 2023Quote: ... 3 μl of this sample were placed on a glow-discharged EM grid (lacey carbon films on Cu 200 mesh, Quantifoil Micro Tools), blotted from the back side for 3 s ...
-
bioRxiv - Biochemistry 2023Quote: ... holey carbon grids (Quantifoil, 300 mesh Au R0.6/1) glow-discharged for 50 seconds were used for EM grids preparation ...
-
bioRxiv - Biochemistry 2023Quote: ... Cryo-EM grids were prepared by pipetting 3 µl of sample on a R1.2/1.3 Cu 300 mesh grid (Quantifoil) and plunge-freezing in liquid ethane using a Vitrobot Mark IV (ThermoFisher).