Labshake search
Citations for Quantifoil Micro Tools :
251 - 300 of 1446 citations since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2023Quote: The affinity-purified RNCs were vitrified on UltrAuFoil R 1.2/1.3 300-mesh grids (Quantifoil) coated with graphene oxide (Sigma-Aldrich) ...
-
bioRxiv - Biochemistry 2023Quote: ... UltrAufoil Au 200 mesh R2/2 grids (Quantifoil) EM grids were glow-discharged on each side for 90 s at 30 sccm ...
-
bioRxiv - Biophysics 2023Quote: UltrAuFoil holey-gold 300 mesh 1.2/1.3 μm size/hole space grids (UltrAuFoil, Quantifoil) were glow discharged ...
-
bioRxiv - Molecular Biology 2023Quote: ... 3.5 μL sample was applied to a glow-discharged 300 mesh gold grid (Quantifoil R1.2/1.3). The sample was incubated with the grid for 60 seconds at 8 □ and 100% humidity to maximize the absorption ...
-
bioRxiv - Biophysics 2023Quote: EM grids (UltrAuFoil R2/2 Au 200 mesh Q250AR2A and Quantifoil R2/2 Au 200 mesh Q2100AR2) were micropatterned using the Alveole PRIMO micropatterning system20–22 ...
-
bioRxiv - Biochemistry 2023Quote: ... Holey carbon R2/2 300 mesh grids (Quantifoil Micro Tools GmbH) were glow-discharged for 90 sec at 25 mA using a PELCO easiGlow glow discharge cleaning system ...
-
bioRxiv - Biochemistry 2023Quote: ... R1.2/1.3 TEM grids (Quantifoil). 3 μl of Hexon-hLF complex (1 mg/ml ...
-
bioRxiv - Molecular Biology 2023Quote: ... 200 mesh grids (Quantifoil) at 37°C and 5% CO2 ...
-
bioRxiv - Neuroscience 2023Quote: Three μl of the sarkosyl-insoluble fractions were applied to glow-discharged (Edwards S150B) holey carbon grids (Quantifoil AuR1.2/1.3, 300 mesh) that were plunge-frozen in liquid ethane using a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Immunology 2023Quote: ... The sample was diluted in PBS and incubated on ice for 20 minutes before freezing on glow discharged R1.2/1.3 200 mesh Au holey carbon grids (Quantifoil). The grids were then plunge frozen in ethane using a Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Microbiology 2023Quote: ... trehalose solution to mitigate crystalline ice formation and 4 μL of this mixture immediately applied to a R2/1 Cu 200 grid (Quantifoil), which had been glow-discharged for 1 min at 0.19 mbar and 20 mA in a PELCO easiGlow device shortly before use ...
-
bioRxiv - Neuroscience 2023Quote: Three μl of the sarkosyl-insoluble fractions were applied to glow-discharged (Edwards S150B) holey carbon grids (Quantifoil Au R1.2/1.3, 300 mesh) that were plunge-frozen in liquid ethane using a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Neuroscience 2023Quote: ... applied to glow-discharged 2/2 μm holey carbon-coated 200-mesh gold grids (Quantifoil) and plunge-frozen in liquid ethane using a Vitrobot Mark IV (Thermo Fisher) ...
-
bioRxiv - Neuroscience 2023Quote: A volume of 3 µl purified complex at a concentration of 1.5 mg/ml was applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3 Cu 200 mesh). The grids were blotted with a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Neuroscience 2023Quote: ... The supernatants were retained and applied to glow-discharged 1.2/1.3 μm holey carbon-coated 300-mesh gold grids (Quantifoil) and plunge-frozen in liquid ethane using a Vitrobot Mark IV (Thermo Fisher) ...
-
bioRxiv - Pathology 2023Quote: ... bombycis spores (1×108 spores/mL) were placed on grids (Cu R2/1, 200 mesh) (Quantifoil Micro Tools GmbH, Jena, Germany) for 5 min and germinated in 0.1 M KOH for 15 min at 30°C ...
-
bioRxiv - Pathology 2023Quote: ... bombycis spores (1×105 spores/mL) were placed on nickel grids (Quantifoil, Beijing, China) for 15 min and germinated in 0.1 M KOH for 30 min at 30°C ...
-
bioRxiv - Pathology 2023Quote: ... and they were prepared as previously described [60] and placed on nickel grids (Quantifoil, Beijing, China). All samples were washed three times by ddH2O at room temperature ...
-
bioRxiv - Molecular Biology 2023Quote: Affinity purified ribosomes at a concentration of ~ 65 nM (A260 of 3.2) were vitrified on UltrAuFoil R1.2/1.3 300-mesh grids (Quantifoil) coated with graphene oxide (GO) ...
-
bioRxiv - Microbiology 2023Quote: ... Au 200 mesh grids (Quantifoil Micro Tools GmbH, Germany). The grids were blotted with filter paper for 6 s and immediately plunged into liquid ethane using a Vitrobot Mark IV (ThermoFisher Scientific ...
-
bioRxiv - Molecular Biology 2023Quote: ... Quantifoil R3.5/1 200-mesh grids (Quantifoil Micro Tools GmbH) were glow-discharged for 30 s at 40 mA using a GloQube (Quorum ...
-
bioRxiv - Physiology 2023Quote: ... Sample solution (~ 3 μl) was applied on freshly glow discharge TEM grids (Quantifoil R2/1, Cu, mesh 200) and plunge-frozen in liquid ethane using Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Neuroscience 2023Quote: ... Three μl were applied to glow-discharged (Edwards S150B) holey carbon grids (Quantifoil Au R1.2/1.3, 300 mesh) that were plunge-frozen in liquid ethane using Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2023Quote: ... Cryo-EM grids were prepared by applying 3.5 μL of protein sample at a concentration of 0.25 mg/ml to one side of a Quantifoil 400 mesh 1.2/1.3 gold grid with graphene oxide support film (Quantifoil). After 30 s ...
-
bioRxiv - Molecular Biology 2023Quote: Cryo-EM grids preparation for the isolated BRCA1ΔExon11:FL BARD1 complex: UltrAuFoil R1.2/1.3 300-mesh gold grids (Quantifoil Micro Tools GmbH) were cleaned via indirect plasma using a Tergeo EM plasma cleaner (Pie Scientific ...
-
bioRxiv - Molecular Biology 2023Quote: ... applied to a glow-discharged R 1.2/1.3 300 mesh UltrAuFoil gold grid (Quantifoil Micro Tools GmbH) and plunge-frozen in liquid ethane using a Vitrobot Mark IV (Thermo Scientific ...
-
bioRxiv - Biophysics 2023Quote: ... R1.2/1.3 Mo400 grids (Quantifoil, Jena, Germany) were glow discharged and used within an hour ...
-
bioRxiv - Bioengineering 2023Quote: ... 3.0 µl aliquots at a concentration of 0.87 or 1.0 mg/ml of the spikeD614G-binder sample or the spikeOmicron-binder sample were applied onto glow-discharged carbon-coated copper grids (Quantifoil R2/1, 400 mesh), blotted for 4.0-8.0 s ...
-
bioRxiv - Neuroscience 2023Quote: ... UltrAuFoil grids 300 mesh 1.2/1.3 or 0.6/1.0 from Quantifoil were glow discharged in a PELCO easiGlow for 25mA/15s ...
-
bioRxiv - Cell Biology 2023Quote: Cells were blotted on EM grids (R 2/1 holey carbon 200 films on Cu 200 mesh, Quantifoil Micro Tools). The grids were first glow-discharged and 4 µl of trypanosome wild-type culture (2-4 · 107 cells/ml ...
-
bioRxiv - Cell Biology 2023Quote: ... 3 μl of this sample were placed on a glow-discharged EM grid (lacey carbon films on Cu 200 mesh, Quantifoil Micro Tools), blotted from the back side for 3 s ...
-
bioRxiv - Biochemistry 2023Quote: ... holey carbon grids (Quantifoil, 300 mesh Au R0.6/1) glow-discharged for 50 seconds were used for EM grids preparation ...
-
bioRxiv - Biochemistry 2023Quote: ... Cryo-EM grids were prepared by pipetting 3 µl of sample on a R1.2/1.3 Cu 300 mesh grid (Quantifoil) and plunge-freezing in liquid ethane using a Vitrobot Mark IV (ThermoFisher).
-
bioRxiv - Biochemistry 2023Quote: ... UltrAuFoil R1.2/R1.3 300 mesh gold grids (Quantifoil) were glow-discharged twice (once on each side ...
-
bioRxiv - Molecular Biology 2023Quote: ... but the sample concentration was 4.4 mg/ml and it was applied to holey carbon grids with copper mesh (Quantifoil R1.2/1.3 Cu 200 mesh).
-
bioRxiv - Molecular Biology 2023Quote: ... and vitrification of samples on holey carbon R 1.2/1.3 copper 300 mesh grids (Quantifoil) using a Vitrobot MarkIV device (Thermofisher ...
-
bioRxiv - Molecular Biology 2023Quote: ... UltrAuFoil R 1.2/1.3 300 Au mesh (Quantifoil) grids were glow discharged with residual air for 30 seconds ...
-
bioRxiv - Molecular Biology 2023Quote: ... were applied onto glow-discharged holey carbon grids (Quantifoil R1.2/1.3). Excess samples were blotted for 3s with a blot force of 1 and were vitrified by plunging into liquid ethane using a Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Microbiology 2023Quote: ... and 4 µl of the mixture was applied to a glow-discharged holey-carbon copper EM grid (R2/1 or R2/2, Quantifoil). The grid was automatically backside blotted for 4-6s in a Mark IV Vitrobot (Thermo Fischer Scientific ...
-
bioRxiv - Molecular Biology 2023Quote: ... a 4 µl sample of purified complex was applied to glow-discharged R2/1 300 mesh holey carbon copper grids (Quantifoil Micro Tools GmbH), using a conc ...
-
bioRxiv - Microbiology 2023Quote: 3 µL of the purified FL or truncated RSV NC sample were applied to a glow-discharged R2/1 300 mesh holey carbon copper grid (Quantifoil Micro Tools GmbH) and plunge-frozen in liquid ethane using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Microbiology 2023Quote: ... continuous carbon film-covered grids (Quantifoil Cu R3.5/1 with 2 nm continuous carbon film ...
-
bioRxiv - Molecular Biology 2023Quote: Cryo-EM specimens were prepared on UltrAuFoil R1.2/1.3 holey gold grids (Quantifoil Microtools). For complex formation ...
-
bioRxiv - Molecular Biology 2023Quote: ... 3μL of protein was deposited on holey carbon copper grids (QUANTIFOIL R 1.2/1.3-2nm, 300 mesh, EMS) which had been glow-discharged for 20s at 15 mA using PELCO easiGlow (TedPella Inc) ...
-
bioRxiv - Biophysics 2023Quote: ... 2.5 µl samples of GDN-purified SLC26A6 were applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3 Au 200 mesh) at a concentration of 2 mg ml-1 ...
-
bioRxiv - Molecular Biology 2023Quote: ... 3.5 μL was applied to freshly glow discharged Quantifoil R2/2 300-square-mesh gold grids (Quantifoil) in a Vitrobot IV (ThermoFisher ...
-
bioRxiv - Biophysics 2023Quote: ... The mixture was applied to plasma-cleaned grids (300 mesh Quantifoil Au R1.2/1.3, EMS) for 30-second incubations ...
-
bioRxiv - Biochemistry 2023Quote: 3 μL of ∼120 nM mitoribosome was applied onto a glow-discharged (20 mA for 30 sec) holey- carbon grid (Quantifoil R2/2, copper, mesh 300) coated with continuous carbon (of ∼3 nm thickness ...
-
bioRxiv - Biochemistry 2023Quote: ... was prepared and 3.0 μl applied to freshly glow-discharged grids (1.2/1.3 300 mesh Cu Quantifoil), with blotting for 3 s at >90% humidity before freezing in liquid ethane using a CP3 plunger (Gatan) ...
-
bioRxiv - Biophysics 2023Quote: ... The mixture was applied to plasma-cleaned grids (300 mesh Quantifoil Cu R1.2/1.3, EMS) for 30-second incubations ...