Labshake search
Citations for Quantifoil Micro Tools :
151 - 200 of 1446 citations since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2024Quote: 5 mg/mL ROCKET and ROCKETAAXWA with 100 µM CDL were frozen on Quantifoil 1.2/1.3 Au 300 mesh grids (Quantifoil Micro Tools). 3 µL of sample was applied to each grid which was then blotted for 3 s and plunge-frozen into liquid ethane using FEI Virtobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Biophysics 2024Quote: A 3 μL of aliquot Msmeg MmpL3 ΔC NDs at a concentration of 0.6 mg/mL was applied to glow-discharged (Quantifoil Cu R2/2, 300 mesh) holey carbon grids for 30 sec and blotted for 2×5 sec at 4°C and 100% humidity ...
-
bioRxiv - Microbiology 2024Quote: ... A 4.5 µL droplet of the culture was applied to glow discharged copper grids (Quantifoil R2/2, Quantifoil Micro Tools) and blotted for 2.5 s in a 95% humidity chamber at 20 °C ...
-
bioRxiv - Biophysics 2024Quote: A 3 µl aliquot of sample solution was applied to a glow discharge QUANTIFOIL R1.2/1.3 Au 300 mesh grid (Quantifoil Micro Tools GmbH) on a Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Biophysics 2024Quote: ... Four μl of this mixture was deposited to glow-discharged cryo-EM grids (UltrAuFoil R1.2/1.3, Quantifoil Cu 2/2, or Quantifoil AU 100 Holey carbon Films R2/1), blotted for 3 seconds at relative humidity 98% and temperature 4°C and plunge-frozen into liquid ethane (Vitrobot) ...
-
bioRxiv - Biophysics 2024Quote: ... Four μl of this mixture was deposited to glow-discharged cryo-EM grids (UltrAuFoil R1.2/1.3, Quantifoil Cu 2/2 ...
-
bioRxiv - Microbiology 2024Quote: ... To each 200-mesh holey carbon grid (Au R1.2/1.3, Quantifoil Micro Tools), 2.5 μL of sample was applied and blotted for 3 s at 80% humidity and 4 °C ...
-
bioRxiv - Biochemistry 2024Quote: The GPR68-Gq pH 6 complex was concentrated to 4 mg/mL and 3 µL was applied onto a glow-discharged 300 mesh 1.2/1.3 gold grid covered in a holey carbon film (Quantifoil). Excess sample was removed with a blotting time of 4 s and a blotting force of 1 at 4 °C prior to plunge freezing into liquid ethane using a Vitrobot Mark IV (Thermo Fisher) ...
-
bioRxiv - Biochemistry 2024Quote: ... while an UltrAuFoil 0.6/1.0 300 mesh (Quantifoil) grid was used with the C3*-hC3Nb2 sample at 0.3 mg/mL and blotted for 11 s at blot force -8 for tilted collection at an angle of 20° ...
-
bioRxiv - Neuroscience 2024Quote: ... 3 μl of sample was applied to glow-discharged 1.2/1.3 μm holey carbon-coated 300-mesh gold grids (Quantifoil) and plunge-frozen in liquid ethane using a Vitrobot Mark IV (Thermo Fisher) ...
-
bioRxiv - Microbiology 2024Quote: A volume of 3 µL of purified Pks13 at 0.9 mg/ml was loaded onto a glow discharged (35 mA, 60 seconds) R1.2/1.3 Au grid with holey carbon foil (Quantifoil). This was blotted for 3 sec at 100% humidity and plunge frozen in liquid ethane using a Vitrobot Mark IV system (ThermoFisher).
-
bioRxiv - Biochemistry 2024Quote: R1.2/1.3 Cu 300 mesh holey carbon grids (Quantifoil) were glow discharged using a JEC-3000FC Auto Fine Coater (JEOL Ltd. ...
-
bioRxiv - Biochemistry 2024Quote: R1.2/1.3 Cu 300 mesh holey carbon grids (Quantifoil) were glow discharged using a JEC-3000FC Auto Fine Coater at 7 Pa ...
-
bioRxiv - Molecular Biology 2024Quote: ... Four microliters of the sample were applied onto 300 mesh R1.2/1.3 UltrAuFoil Holey Gold Films (Quantifoil) that were glow discharged for 25 seconds at 15 mA with a Pelco Easiglow 91000 (Ted Pella ...
-
bioRxiv - Microbiology 2024Quote: ... The co-culture-colloidal gold bead mixture was added to glow-discharged copper R2/2 Quantifoil holey carbon grids (Quantifoil Micro Tools GmbH, Jena, Germany). Grids were blotted (under 100% humidity conditions ...
-
bioRxiv - Biochemistry 2024Quote: ... R1.2/1.3 200-mesh copper grids (Quantifoil) were glow-discharged for 2 min (easiGlow ...
-
bioRxiv - Microbiology 2024Quote: ... 4 µl of the concentrated cells were then spotted onto a glow discharged copper grid (R2/2, Quantifoil). By using a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Microbiology 2024Quote: ... 4 µl sample was applied onto Au R2/2 200 mesh (Quantifoil) grids ...
-
bioRxiv - Cell Biology 2024Quote: ... intact MVKCg1 yeasts cells resuspended in PBS were vitrified on Quantifoil Au R2/2 London Finder 300-mesh grids (Quantifoil Micro Tools GmbH) following a similar vitrification procedure as described above for crude membranes ...
-
bioRxiv - Cell Biology 2024Quote: ... An aliquot of 3.5 μl of the crude membrane sample was deposited onto freshly glow-discharged Quantifoil R2/2 200-mesh grids (Quantifoil Micro Tools GmbH,) using the Leica EM GP (Leica Microsystems ...
-
bioRxiv - Microbiology 2024Quote: ... USA) holey carbon grids (R1.2/1.3, 300 mesh Cu grids, Quantifoil Micro Tools, Jena, Germany) were made hydrophilic by plasma cleaning ...
-
bioRxiv - Microbiology 2024Quote: ... To each 200-mesh holey carbon grid (Au R1.2/1.3, Quantifoil Micro Tools), 2.5 μL of sample was applied and blotted for 3 s at 80% humidity and 4 °C ...
-
bioRxiv - Microbiology 2024Quote: ... The mixture was added onto glow-discharged copper R2/2 Quantifoil holey carbon grids (Quantifoil Micro Tools GmbH, Jena, Germany). Grids were blotted for 6-8 seconds (under 100% humidity conditions ...
-
bioRxiv - Microbiology 2024Quote: ... the Quantifoil grids (R1.2/1.3 Cu400 mesh; Quantifoil, Inc.) were glow-discharged for 120 s at 25 mA ...
-
bioRxiv - Molecular Biology 2024Quote: ... to UltrAuFoil R1.2/1.3 grids (Quantifoil). The grids were glow discharged in the presence of amylamine in PELCO easiGlow ...
-
bioRxiv - Molecular Biology 2024Quote: 3 μL aliquot of the β2AR-Gi-scfv16 complex was applied onto glow-discharged 300 mesh grids (Ultraufoil R1.2/1.3 or Quantifoil R1.2/1.3) and vitrified using a Vitrobot Mark IV (Thermo Fischer Scientific ...
-
bioRxiv - Molecular Biology 2024Quote: ... 300 mesh holy carbon grids (Quantifoil, Jena, Germany) which had been glow discharged with 15 mA at 0.39 mBar for 1 min ...
-
bioRxiv - Biochemistry 2024Quote: Samples were prepared by applying the polymerized R-β-Actin actin to freshly glow-discharged Quantifoil 3.5/1 on 200 mesh copper grids (Quantifoil GmbH, Germany), using a Leica GP2 (Leica Microsystems GmbH ...
-
bioRxiv - Biochemistry 2024Quote: ... 15 mA for 30 s using a PELCO easiGlow) copper R1.2/1.3 300-mesh grid (Quantifoil). The grid was blotted with a filter paper (Whatman No.1 ...
-
bioRxiv - Biochemistry 2024Quote: 3µl of the AtGDH-AKG bound binary complex (3 mg/ml) was applied to freshly glow-discharged holey carbon grids (Quantifoil Au R 0.6/1.0 300 mesh). For the apo form AnGDH dataset ...
-
bioRxiv - Biochemistry 2024Quote: Holey grids (Holey carbon filmed 300 mesh gold grids, R1.2/1.3, Quantifoil) were glow discharged with a medium RF power for 30 s using a plasma cleaner PDC-32G-2 (Harrick Plasma ...
-
bioRxiv - Biochemistry 2024Quote: ... 3 µl) were deposited onto UltraAuFoil R1.2/1.3 300 gold mesh grids (QuantiFoil) that were plasma cleaned before use ...
-
bioRxiv - Biochemistry 2024Quote: ... or Holey grids (Holey carbon filmed 300 mesh gold grids, R1.2/1.3, Quantifoil) were glow discharged with a medium RF power for 30 s using a plasma cleaner (PDC-32G-2 ...
-
bioRxiv - Bioengineering 2024Quote: About 3 μl droplets emulsion were applied onto glow-discharged holey carbon grids (Quantifoil Cu R1.2/1.3, 300 mesh), blotted with a Vitrobot Marker IV (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2024Quote: ... 3 µl were frozen in liquid ethane with the Vitrobot Mark IV (FEI company) on 2/1 Quantifoil Multi A holey carbon supported grids (Quantifoil, Multi A, 400 mesh). Freezing was carried out with Whatman #1 filter papers at 4°C with a blot force of 0 ...
-
bioRxiv - Biochemistry 2024Quote: ... 3.2 μl samples of the solution were applied onto EM grids (Quantifoil, R 1.2/1.3 Cu 300 mesh) that had been glow discharged with PELCO easiGlow for 60 seconds in Vitrobot Mark IV chamber at 4°C and 90% humidity ...
-
bioRxiv - Biochemistry 2024Quote: ... a freshly glow-discharged Cu300 R2/2 holey carbon grid with a 2-nm layer of amorphous carbon (Quantifoil) was mounted in the chamber of a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2024Quote: ... was applied to glow-discharged (GloQube® Plus, Quorum, UK) Quantifoil R1.2/1.3 or R2/2 mesh 200 copper holey carbon grid (Quantifoil, Germany), blotted under 100% humidity at 4°C for 6–8 s ...
-
Structures of native SV2A reveal the binding mode for tetanus neurotoxin and anti-epileptic racetamsbioRxiv - Biochemistry 2024Quote: ... 3ul of the complex were subsequently applied to glow-discharged holey grids (Quantifoil R1.2/1.3 Cu 300 mesh) and plunged into liquid ethane after a blotting time of 2s at 90% humidity using a CP3 plunger (Gatan) ...
-
bioRxiv - Biochemistry 2024Quote: ... Graphene oxide-coated Quantifoil R1.2/1.3 300 mesh copper holey carbon grids (Quantifoil Micro Tools) were glow discharged using a PELCO easiGlow Glow Discharge Cleaning system (Ted Pella ...
-
bioRxiv - Biophysics 2024Quote: ... 3 µL of the mixture was then applied to glow-discharged 1.2/1.3 300 mesh Cu grids (Quantifoil). For the detergent sample at pH 9 ...
-
bioRxiv - Biochemistry 2024Quote: Sample volumes of 3.5 μl (8 OD260 per ml) were applied to grids (Quantifoil, Cu, 300 mesh, R3/3 with 3 nm carbon) which had been freshly glow-discharged using a GloQube (Quorum Technologies ...
-
bioRxiv - Cell Biology 2024Quote: Cells were transiently transfected with FKBP8N403K-mScarlet plasmid for 24 hours and then were transferred to cryo-EM grids (Quantifoil, 200-Au-mesh with carbon film) (pre-treated with 50 ug/ml fibronectin for at least 15 minutes ...
-
bioRxiv - Cell Biology 2024Quote: HeLa WT cells or HeLa cells stably expressing Apaf1-GFP were plated on 200 mesh gold EM grids with a holey carbon film R2/2 (Quantifoil). HeLa WT cells were transfected with Apaf1-SNAP-tag ...
-
bioRxiv - Immunology 2024Quote: ... The complex (1 mg/mL) was then applied onto the glow-discharged holy-carbon gold grids (Quantifoil, R1.2/1.3) using an FEI Vitrobot IV ...
-
bioRxiv - Microbiology 2024Quote: ... 3 µL aliquots were applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3 300 mesh, Ted Pella) and incubated for 10 s before automated blotting and flash-freezing in liquid ethane with a Vitrobot Mark IV vitrification system (Thermo Fisher Scientific) ...
-
bioRxiv - Cell Biology 2024Quote: Cells were seeded and grown overnight on Quantifoil carbon film gold grids (Quantifoil R 1/4 on 200 gold mesh) coated with 10 µg/ml FN ...
-
bioRxiv - Cell Biology 2024Quote: ... Glow-discharged Cryo-EM grids (R1.2/1.3, Cu 200 mesh grid, Quantifoil microtools) were mounted on a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Cell Biology 2024Quote: ... Cu supported 3.5/1 Holey Carbon grids (Quantifoil) were glow discharged on both sides for six seconds each using atmospheric air to render them more hydrophilic ...
-
bioRxiv - Evolutionary Biology 2024Quote: Three microliters of freshly purified anKaiC were applied to a glow discharged R1.2/1.3 holey copper grid (Quantifoil Micro Tools GmbH, USA). The grid was then blotted and plunged in precooled liquid ethane using a Vitrobot Mark IV (Thermo Fisher Scientific ...