Labshake search
Citations for Quantifoil Micro Tools :
451 - 500 of 1446 citations since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2023Quote: ... three microliters of EV sample were directly placed onto a glow–discharged 2/2 copper grid (Quantifoil, Jena, Germany). The excess sample was removed with 595 filter paper (Schleicher & Schuell ...
-
bioRxiv - Synthetic Biology 2023Quote: 4 µl of sample was adsorbed onto holey carbon-coated grid (Quantifoil, Germany) that was glow-discharged ...
-
bioRxiv - Biophysics 2023Quote: 3 μL of sample was applied on glow-discharged Au200 R2/1 grids (Quantifoil), and the excess liquid was removed by blotting for 4 s (blot force 3 ...
-
bioRxiv - Biophysics 2023Quote: ... 10 µL of samples were placed on top of a glow-discharged Au200 R2/1 grids (Quantifoil) and incubated in a 100%-humidity controlled environment ...
-
bioRxiv - Biophysics 2023Quote: ... Grids (Quantifoil Cu R1.2/1.3, 300 mesh) were glow discharged at 15 mA for 30 s using PELCO easiGlow system ...
-
bioRxiv - Molecular Biology 2023Quote: ... 4 µl of MHAS2168-Mb_H2 complex (9.4 mg/ml and 6 mg/ml) were applied to glow-discharged (45 s) holey carbon grids (Quantifoil R1.2/1.3 Au 200 mesh) and a Grid Plunger GP2 (Leica ...
-
bioRxiv - Biochemistry 2023Quote: ... we used the Au grids (Quantifoil, 300 mesh Au R1.2/1.3) pretreated by glow-discharging and cysteine ...
-
bioRxiv - Biophysics 2023Quote: R 1.2/1.3 (Quantifoil) (Electron Microscopy Sciences ...
-
bioRxiv - Biochemistry 2023Quote: ... copper grids (Quantifoil Cu R1.2/1.3, 300 mesh) with a thin carbon-supported film ...
-
bioRxiv - Biochemistry 2023Quote: UltrAuFoil R2/2 Au200 mesh grids (Quantifoil) were glow discharged for 1 min on both sides at 25 mA using a Pelco easiGlow unit (Ted Pella ...
-
bioRxiv - Biochemistry 2023Quote: UltrAuFoil gold grids (R0.6/1, Quantifoil Micro Tools GmbH, Germany) were prepared as described previously (Blaza et al ...
-
bioRxiv - Molecular Biology 2023Quote: ... The final sample was applied onto electron microscopy grids covered with a holey carbon layer (Quantifoil), blotted ...
-
bioRxiv - Molecular Biology 2023Quote: 1.2/1.3 300 mesh UltrAuFoil holey gold TEM grids (QuantiFoil)
-
bioRxiv - Biophysics 2023Quote: ... 3.5 μL of prestin sample was applied to Quantifoil 200-mesh 1.2/1.3 Cu grids (Quantifoil) that were plasma cleaned for 30s at 20W ...
-
bioRxiv - Plant Biology 2023Quote: ... 3 μl protein was applied to glow-discharged carbon grids (Quantifoil Cu R1.2/1.3 300 mesh). Subsequently ...
-
bioRxiv - Biophysics 2023Quote: ... 3.5 μL of prestin sample was applied to UltrAuFoil 300-mesh 1.2/1.3 grids (Quantifoil UltrAuFoil) that were plasma cleaned for 40s at 20W ...
-
bioRxiv - Biochemistry 2023Quote: ... The most concentrated fraction was spun for 5 min at 13K rpm before applying 3 µL to UltraAuFoil R1.2/1.3 gold support grids (Quantifoil). Prior to sample applications grids were glow-discharged for 3 min in Pelco easiGlow glow-discharger (Pelco ...
-
bioRxiv - Biophysics 2023Quote: We applied 3 μl of purified MeFDH1 (0.5 mg/ml) to a 1.2/1.3 holey carbon 200 mesh grid (Quantifoil), blotted for 4 s in a 100% humidity environment at 12 °C and then froze the specimens by plunging them into liquid ethane using a Vitrobot Mark IV (FEI).
-
bioRxiv - Biochemistry 2023Quote: ... The detergent was added shortly before applying 3 μL of UBR5Dimer∼UbD∼UBE2D2 to freshly glow-discharged holey carbon grids (Quantifoil, R1.2/1.3, 200 mesh). The sample was consequently plunge-frozen into liquid ethane at 95 % humidity and 4°C (blot force 3 ...
-
bioRxiv - Biochemistry 2023Quote: A 3.5 μL concentrated SPARTA sample was loaded onto a glow discharged UltrAuFoil 300 mesh R1.2/1.3 grids (Quantifoil) using a FEI Vitrobot at 4°C and 100% humidity ...
-
bioRxiv - Biophysics 2023Quote: ... copper Quantifoil grids (Quantifoil Micro Tools GmbH, Germany) prior to were plunge freezing in liquid ethane using a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biophysics 2023Quote: 200 mesh Au grids with R1/4 SiO2 foil (Quantifoil) were glow-discharged for 90 sec at 0.38 mBar and 15 mA using a Pelco easiGlow device ...
-
bioRxiv - Biophysics 2023Quote: ... 4 μl of 4.3 mg/ml Slo1-γ1 complex were applied to glow-discharged UltrAuFoil R2/2 200 grid (Quantifoil). Any excess liquid was removed by blotting for 3.5 s at a blot force of −3 ...
-
bioRxiv - Biochemistry 2023Quote: ... A volume of 3.5 μl of the prepared sample was applied to a glow-discharged holey grid (Quantifoil Au300 R1.2/1.3), and then blotted for 3.5 seconds at room temperature with 90% humidity using a Gatan Cryoplunge 3 system ...
-
Cryo-electron tomography of eel sperm flagella reveals a molecular “minimum system” for motile ciliabioRxiv - Cell Biology 2023Quote: ... holey carbon grids (Quantifoil R2/2) were glow discharged for 30 seconds in a Pelco EasyGlow glow discharge unit ...
-
bioRxiv - Biophysics 2023Quote: Gold 200 mesh carbon or SiO2 R 2/1 grids or R 1.2/20 grids (Quantifoil Micro Tools GmbH) were coated with ∼8 nm of carbon using a Leica ACE600 (Leica Microsystems GmbH) ...
-
bioRxiv - Biophysics 2023Quote: 4 μL purified protein was placed on the holy-carbon grids (Quantifoil Au R1.2/1.3, 300 mesh), which were glow-discharged for 30 s ...
-
bioRxiv - Biophysics 2023Quote: ... HeLa cells were trypsinized and seeded at a density of 0.5 – 0.7 X 105 cells/mL on carbon-coated gold Quantifoil grid (200 mesh, R 2/1, holey SiO2 film; Quantifoil Micro Tools GmbH ...
-
bioRxiv - Biophysics 2023Quote: ... using FluoSpheres (diameter of 1 μm) on gold Quantifoil grids (200 mesh, R 2/1, holey SiO2 film; Quantifoil Micro Tools GmbH ...
-
bioRxiv - Biochemistry 2023Quote: ... applied to glow-discharged R1.2/1.3 Au (200 mesh) EM grids (QUANTIFOIL GmbH), after which the grids were immediately plunge frozen in propane-ethane using a FEI Vitrobot (FEI ...
-
bioRxiv - Biophysics 2023Quote: ... 3 μL of purified mGlu5 (with the different ligands) at 5 mg/ml was applied on glow-discharged holey carbon gold grids (Quantifoil R1.2/1.3, 200 mesh). The grids were blotted using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Biochemistry 2023Quote: ... Cu 200 mesh holey carbon grids (Quantifoil) using a Vitrobot Mark IV (Thermo Fisher ...
-
bioRxiv - Biochemistry 2023Quote: ... holey carbon grids (Quantifoil, R1.2/1.3, 200 mesh) were glow discharged ...
-
bioRxiv - Biochemistry 2023Quote: ... Continuous carbon-supported copper grids (Quantifoil, Cu 300) were glow discharged (PELCO easiGlow ...
-
bioRxiv - Biochemistry 2023Quote: ... 3.0 μL purified protein at a concentration of ∼4.95 mg/mL was used for the glow-discharged holey carbon grids (Quantifoil, R1.2/1.3, Au, 300 mesh). The grids were blotted for 2s at 4°C ...
-
bioRxiv - Biochemistry 2023Quote: EM grids were prepared at 5°C by loading 10 μL of the protein suspension (0.05 mg/mL) onto glow-discharged copper TEM grids with continuous 10–12 nm carbon film coating (300 mesh size; Quantifoil Micro Tools, Großlöbichau, Germany). Excess liquid was blotted off with a strip of filter paper after 45 s followed by staining with 10 μL 2% (w/v ...
-
bioRxiv - Biochemistry 2023Quote: ... R2/1 holey carbon without amorphous carbon from Quantifoil. 3 µL of a 2.5 µM solution was applied to the grid ...
-
bioRxiv - Biochemistry 2023Quote: ... copper TEM grids from Quantifoil (C2-C15nCu40-01) with mesh size 400 ...
-
bioRxiv - Cell Biology 2023Quote: ... Dissected tissues were placed on 200 mesh Molybdenum R2/1 EM grids (Quantifoil) immediately after dissection ...
-
bioRxiv - Biochemistry 2023Quote: The final high resolution data set was collected across 2 grids (Quantifoil 1.2/1.3 200 mesh) prepared with 1.8 mg mL-1 trimeric complex and 0.5 and 0.1 X CMC CHAPS ...
-
bioRxiv - Biophysics 2023Quote: ... 3.5 μl of concentrated purified protein was applied to glow-discharged copper holey carbon grids (Quantifoil R 1.2/1.3, 300 mesh). In all cases ...
-
bioRxiv - Biophysics 2023Quote: A 3 µL aliquot of purified CDTbD623A/D734Aprotein sample at a concentration of 30 µM was applied to a glow discharged QUANTIFOIL® copper R 1.2/1.3 grid with a 2 nm thin extra carbon layer (QUANTIFOIL, GMBH). For calcium depleted CDTb (28 µM) ...
-
bioRxiv - Neuroscience 2023Quote: The purified OR–Gs complex was applied to glow-discharged 300 mesh R1.2/1.3 UltrAuFoil Holey gold support films (Quantifoil). Support films were plunge-frozen in liquid ethane using a Vitrobot Mark IV (Thermo Fisher ...
-
bioRxiv - Cell Biology 2023Quote: ... 4 µL of cell suspension was applied on 200-mesh R ¼ SiO2-film covered gold grids or 200-mesh R2/1 carbon-film covered copper grids (Quantifoil Micro Tools) (for P ...
-
bioRxiv - Cell Biology 2023Quote: 4 ul of Nannochloropsis suspensions (4 x 107 cells mL−1) were pipetted onto a 300 mesh gold Quantifoil grid with 2um holes (Quantifoil Micro Tools, GmbH) and manually blotted from the opposite side in a Vitrobot Mark IV (ThermoFisher Scientific ...
-
bioRxiv - Cell Biology 2023Quote: A volume of 4µl of cells was deposited on R2/1 Cu 200 grids (Quantifoil) that had been glow-discharged for 1 min at 0.19 mbar and 20 mA in a PELCO easiGlow device shortly before use ...
-
bioRxiv - Molecular Biology 2023Quote: Minicells were vitrified on QUANTIFOIL® R0.6/1 or R1.2/1.3 holey carbon grids (Quantifoil Micro Tools) using a Vitrobot Mark IV (Thermo Fisher Scientific).
-
bioRxiv - Biophysics 2023Quote: Quantifoil 1.2/1.3 Cu 300 mesh grids (Quantifoil Micro Tools) were used for sample preparation ...
-
bioRxiv - Biophysics 2023Quote: Three microliters of the purified GLV-HP or GLV-CAT sample was placed on a glow-discharged holey carbon grid (Quantifoil R2/2 or R2/1, Cu 300 mesh; Quantifoil Micro Tools GmbH) for 3 s blotting time at 4°C ...
-
bioRxiv - Biophysics 2023Quote: ... carbon Quantifoil EM grids (Quantifoil Micro Tools).