Labshake search
Citations for Quantifoil Micro Tools :
301 - 350 of 1446 citations since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biophysics 2023Quote: ... 2.5 µl of LDs was applied to glow discharged holey carbon grids (Quantifoil 1.2/1.3), blotted for 6 s with a blot force of 0 and rapidly plunged into liquid nitrogen-cooled ethane using an FEI Vitrobot MarkIV ...
-
bioRxiv - Biophysics 2023Quote: ... grids (Quantifoil R1.2/1.3 200 mesh Cu grids) and plunge-frozen into liquid ethane ...
-
bioRxiv - Cell Biology 2023Quote: ... Cryo-EM grid (Quantifoil R3.5/1, Au 200 mesh) was glow discharged using Gatan Solarus for 60 s ...
-
bioRxiv - Cell Biology 2023Quote: ... Cryo-EM grid (Quantifoil R1.2/1.3, Au 200 mesh) was glow discharged using Gatan Solarus for 60 s right before use ...
-
bioRxiv - Cell Biology 2023Quote: ... An aliquot of 3 ul cell suspension was applied to the glow-discharged holey carbon-coated copper (R 2/1, 200 mesh) (Quantifoil) and blotted for 9 seconds by Leica GP2 (Leica Microsystems) ...
-
bioRxiv - Biochemistry 2023Quote: ... applied on glow-discharged UltrAuFoil R 1.2/1.3 gold grids (Quantifoil Micro Tools), flash-frozen in liquid ethane using a Vitrobot Mark II device (FEI) ...
-
bioRxiv - Biochemistry 2023Quote: ... 4.5 µL of the mixture were then applied on either a glow-discharged UltrAUfoil R1.2/1.3 Au300 or a Quantifoil R1.2/1.3 Cu300 grid (Quantifoil Micro Tools GmbH), blotted for 3 sec and flash-frozen in liquid ethane using a Vitrobot Mark IV device (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2023Quote: The GPR161-Gs-Nb35 complex was concentrated to 3 mg/mL and 3 µl was applied onto a glow-discharged 300 mesh 1.2/1.3 gold grid covered in a holey carbon film (Quantifoil). Excess sample was removed with a blotting time of 3 s and a blotting force of 1 at 4 °C prior to plunge freezing into liquid ethane using a Vitrobot Mark IV (Thermo Fisher) ...
-
bioRxiv - Biochemistry 2023Quote: ... An aliquot of 3.5 μl of ∼30 μM SOD1 mutation fibril solution was applied to glow-discharged holey carbon grids (Quantifoil Cu R1.2/1.3, 300 mesh), blotted for 3.5 s ...
-
bioRxiv - Molecular Biology 2023Quote: ... UltrAuFoil R1.2/1.3 or R0.6/1 300 mesh gold grids (Quantifoil Micro Tools GmbH) were glow discharged on both sides for 1.5 mins on a PELCO easiGlow glow discharge unit (20 mA ...
-
bioRxiv - Molecular Biology 2023Quote: ... Holey carbon grids (Quantifoil Au 300 mesh, R1.2/1.3) were glow-discharged in the Plasma Cleaner PDC-32G-2 (Harrick ...
-
bioRxiv - Molecular Biology 2023Quote: ... 3.8 µl of the samples were applied to glow-discharged holey carbon R1.2/1.3 copper grids (Quantifoil Microtools) and plunge frozen in liquid ethane using a Vitrobot Mark IV (Thermo Fisher ...
-
bioRxiv - Molecular Biology 2023Quote: ... A 2.5-3 μL aliquot of protein sample was dropped onto the glow discharged holey carbon grids (Quantifoil Au R1.2/1.3, 300 mesh), blotted with a Vitrobot Mark IV (ThemoFisher Scientific ...
-
bioRxiv - Molecular Biology 2023Quote: ... The purified virus was applied onto glow-discharged electron microscopy grids covered with holey carbon (Quantifoil, SPT Labtech, Melbourn, UK), blotted ...
-
bioRxiv - Molecular Biology 2023Quote: ... Cells were applied onto electron microscopy grids covered with a holey gold layer (UltrAuFoil, Quantifoil, Jena Bioscience). The grids were flash-frozen using a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Microbiology 2023Quote: Cryo-EM grids were prepared by applying 3.5 μL of concentrated sample at 1.2 mg/mL to glow discharged 400 mesh R1.2/1.3 UltrAuFoil grids (Quantifoil Micro Tools GmbH). The sample was adsorbed for 30 s on the grids followed by plunge freezing in liquid ethane using a Vitrobot Mark IV plunge freezer (Thermo Fischer Scientific) ...
-
bioRxiv - Molecular Biology 2023Quote: ... Samples (3 μl) were applied to Quantifoil 2/1 Cu 300 holey-carbon grids (Quantifoil) glow-discharged 60 s using a PELCO glow-discharge system (Ted Pella) ...
-
bioRxiv - Molecular Biology 2023Quote: ... The complex was incubated at RT for 20 mins and pipetted onto glowed discharged cryo-EM grids (Quantifoil R 2/2 Au 300). Grids were frozen in liquid ethane by using a Vitrobot Mark IV (ThermoFischer ...
-
bioRxiv - Microbiology 2023Quote: ... Both TBEV strain Neudoerfl and Hypr samples were vitrified in liquid ethane on holey carbon coated copper grids (Quantifoil 2/1 ...
-
bioRxiv - Microbiology 2023Quote: ... Both TBEV strain Neudoerfl and Hypr samples were vitrified in liquid ethane on holey carbon coated copper grids (Quantifoil 2/1, mesh 300, Quantifoil Micro Tools GmbH) using Vitrobot Mark IV (Thermo Fisher) ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... supplemented with 0.02% octyl-β-D-glucopyranoside was applied to glow-discharged UltrAuFoil holey gold grids (Quantifoil, Au300-R1.2/1.3). GTP was added to the grid at a final concentration of 1mM and the grids were blotted using an FEI Vitrobot Mark IV (ThermoFisher ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... supplemented with 0.05%octyl-β-D-glucopyranoside was applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3). The grids were blotted for 2 sec using an FEI Vitrobot Mark IV (ThermoFisher ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... 3 μl of the purified complex was applied to glow-discharged holey carbon grids (Quantifoil, Au300 R1.2/1.3). Grids were plunge-frozen in liquid ethane using Vitrobot Mark IV (Thermo Fischer Scientific).
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... 3 μl of the protein complex was applied onto 300 mesh R1.2/1.3 UltrAuFoil Holey gold support films (Quantifoil). For cryo-EM grids preparation of DHA-FFA4-miniGq complex ...
-
bioRxiv - Biophysics 2023Quote: ... The mixture was applied to plasma-cleaned grids (300 mesh Quantifoil Au R1.2/1.3, EMS) for 30-second incubations ...
-
bioRxiv - Biochemistry 2023Quote: 3 μL of ∼120 nM mitoribosome was applied onto a glow-discharged (20 mA for 30 sec) holey- carbon grid (Quantifoil R2/2, copper, mesh 300) coated with continuous carbon (of ∼3 nm thickness ...
-
bioRxiv - Biochemistry 2023Quote: ... was prepared and 3.0 μl applied to freshly glow-discharged grids (1.2/1.3 300 mesh Cu Quantifoil), with blotting for 3 s at >90% humidity before freezing in liquid ethane using a CP3 plunger (Gatan) ...
-
bioRxiv - Microbiology 2023Quote: ... sample aliquots of 3 µL were applied onto UltrAuFoil R2/2 grids (300 mesh, Quantifoil). Grids were blotted for 1 s at 10°C with 100% relative humidity and immediately plunge frozen into liquid ethane using a Vitrobot Mark IV system (TFS) ...
-
bioRxiv - Microbiology 2023Quote: ... sample were placed onto glow-discharged Quantifoil R2/1 Cu300 holey carbon grids (1 µm spacing, 2 µm holes, copper mesh) (Quantifoil, Germany), blotted for 3.5 s before flash-freezing in liquid ethane using a Vitrobot mark IV (FEI ...
-
bioRxiv - Plant Biology 2023Quote: ... H4.VS were applied to unsupported Quantifoil R2/1 200-mesh grids (Quantifoil). Grids were glow-discharged for 20 s in the presence of air using a current of 20 mA ...
-
bioRxiv - Plant Biology 2023Quote: ... H4 NCPs were applied to Quantifoil R2/1 200-mesh grids coated with 2 nm of carbon (Quantifoil). H4.VS were applied to unsupported Quantifoil R2/1 200-mesh grids (Quantifoil) ...
-
bioRxiv - Molecular Biology 2023Quote: ... The nucleotide-free or nucleotide-bound dodecamers were dispensed onto glow discharged UltrAuFoil (Quantifoil GmbH, Germany) R1.2/1.3 holey specimen support (‘grid’ ...
-
bioRxiv - Immunology 2023Quote: R1.2/1.3 300 mesh copper grids (Quantifoil) (Electron Microscopy Sciences ...
-
bioRxiv - Biophysics 2023Quote: ... 3 μL HA trimer (0.75 mg/ml) was applied to holey carbon grid (Quantifoil 400 mesh Au R1.2/1.3) which was glow discharged 30 s at 15 mA ...
-
bioRxiv - Biophysics 2023Quote: ... and applied to holey carbon grid (Quantifoil 400 mesh Cu R1.2/1.3). 3 μL catalase or β-galactosidase were mixed with 0.5 μL L-PEG-L (16 mg/ml ...
-
bioRxiv - Biophysics 2023Quote: The catalase purchased from Sigma (catalog number: C3556) was applied to holey carbon grid (Quantifoil 400 mesh Cu R1.2/1.3) with a final concentration of 1mg/ml ...
-
bioRxiv - Biophysics 2023Quote: ... The holey carbon grids (Quantifoil 300 mesh Cu R1.2/1.3) were glow-discharged for 30s before application of all cryo-specimen used in this study.
-
bioRxiv - Biophysics 2023Quote: ... 3 μL apoferritin (0.67 mg/ml) was loaded on the holey carbon grids (Quantifoil 400 mesh Cu R1.2/1.3) which was glow discharged for 30s ...
-
bioRxiv - Biophysics 2023Quote: ... 2.5 µl samples of GDN-purified SLC26A6 were applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3 Au 200 mesh) at a concentration of 2 mg ml-1 ...
-
bioRxiv - Microbiology 2023Quote: ... The samples were then applied to a Quantifoil R2.0/2.0 Cu 300 mesh grid (Quantifoil Micro Tools GmbH). The grid was freshly glow-discharged for 60 sec at 10 mA using a PIB-10 (Vacuum Device) ...
-
bioRxiv - Microbiology 2023Quote: Four microliters of purified TilA-TslA-TlaA1-TlaA2 complex at 0.5 mg ml-1 in Buffer B (Supplementary Table 5) was applied onto glow-discharged (60 s, 30 mA) 300 mesh R1.2/1.3 Au grids (Quantifoil). Grids were blotted for 3 s with blot force of +15 at 10°C and 100% humidity ...
-
bioRxiv - Molecular Biology 2023Quote: ... 3.5 μL was applied to freshly glow discharged Quantifoil R2/2 300-square-mesh gold grids (Quantifoil) in a Vitrobot IV (ThermoFisher ...
-
bioRxiv - Biochemistry 2023Quote: ... 4 μl of sample was applied to glow discharged Quantifoil 300 mesh 1.2/1.3 (Quantifoil) grids at 4 °C and 90-100% humidity ...
-
bioRxiv - Cell Biology 2023Quote: Quantifoil R3.5/1 Au200 grids (Quantifoil) were glow discharged for 30 s in an Auto306 Edwards Turbo Coater at power 6 (20 mA ...
-
bioRxiv - Molecular Biology 2023Quote: ... 1.5 µL of fibril solution was applied to freshly glow-discharged R2/1 holey carbon film grids (Quantifoil). After the grids were blotted for 12 seconds at a blot force of 10 ...
-
bioRxiv - Molecular Biology 2023Quote: Cryo-EM specimens were prepared on UltrAuFoil R1.2/1.3 holey gold grids (Quantifoil Microtools). For complex formation ...
-
bioRxiv - Molecular Biology 2023Quote: ... 3μL of protein was deposited on holey carbon copper grids (QUANTIFOIL R 1.2/1.3-2nm, 300 mesh, EMS) which had been glow-discharged for 20s at 15 mA using PELCO easiGlow (TedPella Inc) ...
-
bioRxiv - Immunology 2023Quote: ... We used UltrAuFoil R 1.2/1.3 (Au, 300-mesh; Quantifoil Micro Tools GmbH) grids for freezing ...
-
bioRxiv - Pathology 2023Quote: ... 300 mesh Cu grid (Quantifoil Micro Tools) using a Crion electrostatic gun and gold eyelash micromanipulators.
-
bioRxiv - Biophysics 2023Quote: mGluR3 samples ranging from 2.0-4.7 mg/mL were applied at a volume of 3 μL to plasma treated UltrAuFoil 1.2/1.3 300 mesh grids (Quantifoil). Vitrified samples were prepared using a Vitrobot Mk IV (Thermo Fisher) ...