Labshake search
Citations for Quantifoil Micro Tools :
1 - 50 of 1528 citations since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biophysics 2024Quote: ... EM grids (Quantifoil R1.2/1.3 ...
-
bioRxiv - Microbiology 2024Quote: ... Continuous carbon grids (Quantifoil R 2/2 on Cu 300 mesh grids + 2 nm Carbon ...
-
bioRxiv - Microbiology 2024Quote: ... Continuous carbon grids (Quantifoil R 2/2 on Cu 300 mesh grids + 2 nm Carbon, Quantifoil Micro Tools C2-C16nCu30-01) were glow-discharged for 5 sec in an easiGlow Glow Discharge Cleaning System (Ted Pella Inc.) ...
-
bioRxiv - Microbiology 2024Quote: ... Sample volumes of 3.5 µl (8 OD260 per ml) were applied to grids (Quantifoil, Cu, 300 mesh, R3/3 with 3 nm carbon) which had been freshly glow-discharged using a GloQube (Quorum Technologies ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... All samples were pipetted at a volume of 3 µL onto UltrAufoil R1.2/1.3 300 mesh holey grids (Quantifoil, Germany) which had been glow discharged in air at 15 mA for 180 s using a Pelco EasyGlow ...
-
bioRxiv - Biochemistry 2024Quote: 2.5-3.0 μL of the crosslinked complexes were applied onto 300-mesh Quantifoil R1.2/1.3 Cu grids (Quantifoil Micro Tools GmbH, Germany), which were glow-discharged before use with a PIB-10 ION Bombarder (Vacuum Device Inc.) ...
-
bioRxiv - Biochemistry 2024Quote: ... Quantifoil Cu 200 R2/2 holey carbon grids (Quantifoil) were glow discharged negatively for 45 sec before sample application ...
-
bioRxiv - Biochemistry 2024Quote: UltrAuFoil R1.2/1.3 300-mesh grids (Quantifoil) were glow discharged at 40 mA for 5 minutes using a GloQube® Plus Glow Discharge System (Quorum) ...
-
bioRxiv - Biophysics 2024Quote: ... This bleb/beads suspension was then applied onto glow discharged plasma-cleaned carbon-coated copper grids (GR1/2, Quantifoil) and manually blotted for ∼3 seconds with 55 mm Whatman filter paper (ThermoFisher ...
-
bioRxiv - Microbiology 2024Quote: ... The mixture was deposited onto freshly glow-discharged grids (R2/1 Quantifoil) for 1 min ...
-
bioRxiv - Molecular Biology 2024Quote: ... a 2.5 mL suspension of purified medusavirus particles was applied to a glow-discharged Quantifoil grid (R1.2/1.3 Mo; Quantifoil Micro Tools GmbH, Germany). The grid was blotted with filter paper (blotting time ...
-
bioRxiv - Molecular Biology 2024Quote: ... Quantifoil Multi Holes grids (Quantifoil Micro Tools GmbH, Germany).
-
bioRxiv - Microbiology 2024Quote: ... 3.5 μL of the culture were applied onto glow-discharged copper EM grids (R2/1, Quantifoil), automatically blotted and plunged into liquid ethane/propane (Tivol et al ...
-
bioRxiv - Microbiology 2024Quote: ... copper EM grids (Cu 200 R 2/1, Quantifoil) were used ...
-
bioRxiv - Microbiology 2024Quote: ... 4 μL of the cell mixture was applied three times onto glow-discharged copper EM grids (R2/2, Quantifoil), followed by plunge freezing into liquid ethane/propane ...
-
bioRxiv - Microbiology 2024Quote: ... continuous carbon film-covered grids (Quantifoil Cu R3.5/1 ...
-
bioRxiv - Cell Biology 2024Quote: ... 4 × 104 MDM cells were seeded on glow discharged and UV-light sterilized holey carbon grids (R2/2, Au, 200 mesh, Quantifoil), which were placed in a glass-bottomed ‘microwell’ of 35-mm MatTek dish (MatTek ...
-
bioRxiv - Microbiology 2024Quote: The total 2.5 µL sample was applied to both sides of glow-discharged 400-mesh R1.2/1.3 Cu grids (Quantifoil, Jena, Germany). The grids were blotted for 14 s at a humidity of 100% at 8 °C and rapidly frozen in liquid ethane using a Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
Molecular insights into the atypical activation mechanism of GPR156 in maintaining auditory functionbioRxiv - Molecular Biology 2024Quote: ... Gi3-bound: 4.5 mg/ml) was applied onto the glow-discharged holey carbon grids (Quantifoil, R1.2/1.3, 300 mesh). The grids were blotted for 3.0 s with a blot force of 10 at 4 ℃ ...
-
bioRxiv - Molecular Biology 2024Quote: ... about 0.9 mg/ml for DSS1–INTAC–PEC complex) was applied onto a glow-discharged holey carbon grid (Quantifoil Au, R1.2/1.3 or R2/2, 300 mesh). After blotting for 3 to 6 s ...
-
bioRxiv - Biochemistry 2024Quote: ... carbon-coated (Quantifoil R 2/2) 200-mesh copper grids (Electron Microscopy Sciences ...
-
bioRxiv - Biochemistry 2024Quote: IN-IBD complex (0.1 mg/mL) was applied onto freshly plasma cleaned (20s, Solarus plasma cleaner) holey grids (Quantifoil UltrAufoil R 1.2/1.3 300 mesh) at 4°C in the cold room with ∼90% humidity ...
-
bioRxiv - Biophysics 2024Quote: ... grids (Quantifoil R1.2/1.3 ...
-
bioRxiv - Cell Biology 2024Quote: ... 3 µl of cell suspension was applied to a freshly grown discharged holey carbon grid (Quantifoil® #200, R2/2). Grids were immediately blotted from the back side using Whatman filter paper #1 (GE Healthcare ...
-
bioRxiv - Cell Biology 2024Quote: ... with holey R 1/4 carbon film (Quantifoil Micro Tools GmbH) were glow-discharged for 30 seconds at 5 mA using an EasiGlow system (Pelco ...
-
bioRxiv - Cell Biology 2024Quote: ... the sample was gently resuspended and 4 µl was transferred to a glow-discharged holey carbon R2/1 copper grid (Quantifoil Micro Tools) suspended in the chamber of a Vitrobot (Thermo Fisher Scientific) ...
-
bioRxiv - Neuroscience 2024Quote: Cryo-EM grids (Quantifoil 1.2/1.3, 300 mesh) were glow-discharged for 1 min using an Edwards (S150B ...
-
bioRxiv - Biochemistry 2024Quote: ... 300 mesh (Quantifoil) and plunge-frozen into liquid ethane (Vitrobot Mark IV ...
-
bioRxiv - Biochemistry 2024Quote: ... holey carbon grid (Quantifoil grid R2/1, 200 mesh, Cu) that had been treated with H2 and O2 mixtures for 30 s ...
-
bioRxiv - Neuroscience 2024Quote: ... Supernatant after centrifugation mixed with 10-nm gold beads solution (Aurion, cat # 25486) at 1:1 ratio was added to the mounted grid (Quantifoil R2/2 Cu 200 EM). No other chemicals or stimulation were applied prior to plunge freezing ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: Grids were prepared by applying 3 μL of purified CB1-Gi complex at 12 mg/ml to glow-discharged holey carbon gold grids (Quantifoil R1.2/1.3, 200 mesh). The grids were blotted using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Microbiology 2024Quote: ... 45nm Thick from Protochips and Au Quantifoil R1.2/1.3 300 mesh from Quantifoil.
-
bioRxiv - Immunology 2024Quote: ... 3 µL aliquots were applied to UltrAuFoil gold R0.6/1 grids (Quantifoil) and subsequently blotted for 6 seconds at blot force 0 ...
-
bioRxiv - Microbiology 2024Quote: Freshly continuous thin layer of carbon grids (Quantifoil 300-mesh Au R1.2/1.3 ...
-
bioRxiv - Immunology 2024Quote: ... and Quantifoil R 2/1 (Cu, 400-mesh; Quantifoil Micro Tools GmbH) were used for freezing ...
-
bioRxiv - Immunology 2024Quote: Quantifoil R2/2 holey carbon copper grids (Quantifoil, Grosslöbichau, Germany) were cleaned by overnight incubation in ethyl acetate and coated with 1 nm continuous carbon foil by floatation ...
-
bioRxiv - Immunology 2024Quote: ... 1.2/1.3 (Au, 300-mesh; Quantifoil Micro Tools GmbH) and Quantifoil R 2/1 (Cu ...
-
bioRxiv - Biochemistry 2024Quote: ... 4 uL of the concentrated sample was applied to freshly glow-discharged R2/1 holey carbon grids (Quantifoil), blotted with blot force of 5 for 5 s using a Vitrobot Mark IV (Thermo Fisher ...
-
bioRxiv - Biochemistry 2024Quote: Ultra-Au 1.2/1.3 grids (Quantifoil) are glow discharged on air for 45 s at 30 mA (Emitech Glow Discharge) ...
-
bioRxiv - Biochemistry 2024Quote: ... The sample was applied to Holey carbon grids (3.5/1, 400 mesh, Quantifoil) at 4 °C ...
-
bioRxiv - Biochemistry 2024Quote: A volume of 3 µl purified protein complex at a concentration of 1mg/ml (JSR1-hGi) or 8 mg/ml (JSR1-jsGiq) was applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3 Cu 200 mesh). The grids were blotted with a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2024Quote: Quantifoil R1.2/1.3 300 mesh Cu grids (Quantifoil Micro Tools GmbH) were coated with a homemade amorphous carbon film ...
-
bioRxiv - Biochemistry 2024Quote: ... Vitrified specimen was prepared by applying 3 μl of protein complexes onto a glow-discharged 300 mesh gold holey carbon Quantifoil R 1.2/1.3 grid (Quantifoil Micro Tools) and frozen in liquid ethane cooled by liquid nitrogen inside a Vitrobot Mark IV (FEI) ...
-
bioRxiv - Biochemistry 2024Quote: ... or calpain-3-titin/I81-I83 (2mg/mL) from Superose 6 increase 10/300GL column chromatography was loaded onto glow-discharged holey carbon grids (Quantifoil 1.2/1.3 + 2 nm Carbon). The grids were blotted with filter paper for 2.5 secs at 22 °C and then immediately plunged into liquid ethane cooled by liquid nitrogen using a Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Biochemistry 2024Quote: ... of the freshly eluted complex peak solution (4.0 mg/mL) was loaded onto glow-discharged holey carbon grids (Quantifoil 2/2). The procedures for blotting and plunge freezing the grids were the same as above ...
-
bioRxiv - Biochemistry 2024Quote: Samples (3 μl) were applied onto a glow-discharged UltrAuFoil grid (Quantifoil GmbH) and were flash frozen in liquid ethane using the Vitrobot mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biophysics 2024Quote: ... 3 μL of the supernatant was then applied to a glow-discharged grid (R1.2/1.3 300 mesh Au grid, Quantifoil), blotted for 2 s with force 0 and plunged into liquid ethane using a Vitrobot Mark IV (Thermo Fisher Scientific).
-
bioRxiv - Biophysics 2024Quote: Approximately 3□μL of the sample solution were put on newly glow-discharged TEM grids (Quantifoil R2/1, Cu, mesh 200) and plunge-frozen in liquid ethane using the Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Biophysics 2024Quote: Electron microscopy grids (Quantifoil Au, 200-mesh copper R1.2/1.3) were glow-discharged for 90 s using PELCO easiGlow ...
-
bioRxiv - Biochemistry 2024Quote: A 3Cµl portion of the sample was loaded onto glow-discharged holey carbon grids (Quantifoil Cu/Rh 300 mesh R1.2/1.3), which were then plunge-frozen in liquid ethane ...