Labshake search
Citations for Quantifoil Micro Tools :
1151 - 1200 of 1446 citations since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2020Quote: A sample of concentrated wild-type TSCCFL was applied to a carbon-coated holey carbon grid (R1.2/1.3, Quantifoil) and stained with 2% (w/v ...
-
bioRxiv - Cell Biology 2020Quote: ... Cells were incubated at 37°C and 5% CO2 for 16h prior to trypsinization and seeding onto 200 mesh gold holey carbon grids (R2/2-2C; Quantifoil Micro Tools), which were placed in 3D printed grid holders [39] ...
-
bioRxiv - Cell Biology 2020Quote: Gold EM grids with Quantifoil R 2/1 holey carbon film (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Molecular Biology 2020Quote: ... applied to plasma-cleaned 200-mesh Cu R2/1 or 300-mesh Au R1.2/1.3 grids (both Quantifoil) and plunge-frozen in liquid ethane ...
-
bioRxiv - Molecular Biology 2020Quote: ... plunge frozen on a 200-mesh Cu R2/1 grid (Quantifoil), was collected on a Titan Krios TEM operated at 300 keV (Thermo Fisher Scientific ...
-
bioRxiv - Molecular Biology 2020Quote: ... A small dataset of Apo Pol III applied to a 300-mesh Au R1.2/1.3 grid (Quantifoil) was recorded at a magnification of 92,000x corresponding to a pixel size of 1.566 Å/pixel ...
-
bioRxiv - Biochemistry 2020Quote: ... 3 μL of the concentrated RdRp-RNA complex were mixed with 0.5 μl of octyl ß-D-glucopyranoside (0.003% final concentration) and applied to freshly glow discharged R 2/1 holey carbon grids (Quantifoil). The grids were blotted for 5 seconds using a Vitrobot MarkIV (Thermo Fischer Scientific ...
-
bioRxiv - Molecular Biology 2020Quote: ... at 13 °C and 100% humidity: 3 μl of sample were applied onto a freshly glow-discharged copper R2/1 300 mesh grid (Quantifoil), blotted for 8 s on both sides with blotting force −20 and plunge-frozen in liquid ethane.
-
bioRxiv - Molecular Biology 2020Quote: ... Frozen-hydrated samples were prepared on plasma-cleaned Quantifoil R1.2/1.3 holey carbon EM grids (Quantifoil) using a Vitrobot Mark IV vitrification robot (FEI ...
-
bioRxiv - Molecular Biology 2020Quote: Aliquots of 3.5 μl concentrated samples were loaded onto glow-discharged holey carbon grids (Quantifoil Cu R1.2/1.3, 300 mesh). Grids were blotted for 5 s and plunge-frozen in liquid ethane cooled by liquid nitrogen using a Vitrobot MarK IV (Thermo Fisher ...
-
bioRxiv - Molecular Biology 2020Quote: ... gold 300 mesh Quantifoil R2/2 holey carbon grids (Quantifoil Micro Tools) were glow discharged using an Edwards Sputter Coater 305B ...
-
bioRxiv - Molecular Biology 2020Quote: ... Four μl of sample was applied to glow-discharged 1.2/1.3 holey carbon coated gold grids (Quantifoil AU R1.2/1.3, 300 mesh) for 30s ...
-
bioRxiv - Molecular Biology 2020Quote: ... 300 mesh holey gold grids (UltrAuFoil R1.2/1.3, Quantifoil). Excess samples were removed from grids by blotting with Whatman No.1 filter paper for 5-7 s ...
-
bioRxiv - Molecular Biology 2020Quote: ... 4 μl sample was applied onto Quantifoil grid Rh/Cu 200 R2/2 (Quantifoil, Inc), and was flash frozen into liquid ethane using a Vitrobot (FEI ...
-
bioRxiv - Bioengineering 2020Quote: ... the liposomes were plunge-frozen in liquid ethane on carbon holey film grids (R2X2 Quantifoil; Micro Tools GmbH, Jena, Germany). The grids were transferred to a cryo-specimen holder (Gatan 626 ...
-
bioRxiv - Molecular Biology 2020Quote: ... or the purified apo complex sample at about 0.75mg/ml (combined with 0.5 µL of 0.025% DDM) was applied onto a glow-discharged holey carbon grid (Quantifoil R1.2/1.3), blotted ...
-
bioRxiv - Genomics 2020Quote: ... Vitrified specimens were prepared by adding 4 μl disome samples at the concentration of ~ 150 nM to a glow-discharged holey carbon grid (Quantifoil R1.2/1.3), which was covered with a freshly made thin carbon film ...
-
bioRxiv - Biochemistry 2020Quote: ... and 2 µL sample was applied to glow-discharged gold holey carbon 1.2/1.3 300-mesh grids (Quantifoil) coated in-house with graphene oxide55-57 ...
-
bioRxiv - Biochemistry 2020Quote: ... glow-discharged 1.2/1.3 AuFoil gold grids (Quantifoil®) were coated with graphene-oxide (GO ...
-
bioRxiv - Biochemistry 2020Quote: ... KBP was diluted to 0.3 mg/ml in KBP dilution buffer and 4 μl were applied to glow-discharged 1.2/1.3 AuFoil gold grids (Quantifoil®). For the third approach ...
-
bioRxiv - Biochemistry 2020Quote: ... Quantifoil R1.2/1.3 Cu 200 mesh (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Biochemistry 2020Quote: UltrAuFoil R1.2/R1.3 300 mesh gold grids (Quantifoil Micro Tools GmbH, #N1-A14nAu30-01) were glow-discharged twice (once on each side ...
-
bioRxiv - Molecular Biology 2020Quote: 3 μL of sample was applied onto a holey carbon grid (Quantifoil, Cu, R1.2/1.3, 300 mesh) rendered hydrophilic by a 30 s glow-discharge in air (11 mA current with PIB-10) ...
-
bioRxiv - Biochemistry 2020Quote: A droplet of 3 μl of purified GluD2 Δ870 at a concentration of ~0.8 mg/ml was applied onto a glow discharged 1.2/1.3 300 mesh ultra foil gold grid (Quantifoil). It was blotted for 3 seconds at a blot force of 0 using the FEI Vitrobot Mark IV at 14°C and 95 % humidity ...
-
bioRxiv - Biochemistry 2020Quote: ... 3 μL of purified AVP-V2R-Gs-Nb35 at 0.75 mg/ml concentration were applied on glow-discharged Quantifoil R 1.2/1.3 300 mesh copper holey-carbon grids (Quantifoil Micro tools GmbH, Germany), blotted for 4.5s and then flash-frozen in liquid ethane using the semi-automated plunge freezing device Vitrobot Mark IV (ThermoFisher ...
-
bioRxiv - Biochemistry 2020Quote: ... The samples were applied on holey carbon gold grids (Quantifoil 1.2/1.3, 400 mesh) that were glow discharged for 35 seconds using PELCO easiGlow glow discharge cleaner ...
-
bioRxiv - Biophysics 2020Quote: ... with 2.3 M sucrose9 and transferred to holy carbon finder grids (R3.5/1 Copper NH2 - Quantifoil, Jena, Germany). Sections were stored at 4 °C until further processing.
-
bioRxiv - Biophysics 2020Quote: ... Two-to-three cleaned nuclei were transferred onto a freshly glow-discharged copper EM grid (R1.2/1.3; Quantifoil, Jena, Germany) in an LSB liquid drop of about 5-μl.
-
bioRxiv - Biochemistry 2020Quote: Cryo-EM specimens were prepared on UltrAuFoil R1.2/1.3 holey gold grids (Quantifoil microtools) that were plasma cleaned using a Tergeo plasma cleaner (PIE Scientific ...
-
bioRxiv - Biophysics 2020Quote: ... and urine were applied in 3 µl-volumes onto glow-discharged Quantifoil Au R2/2 holey carbon 300 mesh grids (Quantifoil). Grids were blotted for 2.0 s and plunged into liquid ethane cooled by liquid nitrogen ...
-
bioRxiv - Biophysics 2020Quote: ... were applied to a glow-discharged UltrAuFoil R1.2/1.3 300-mesh gold grid (Quantifoil) and incubated for 20 s under 100 % humidity at 15 °C ...
-
bioRxiv - Biochemistry 2020Quote: ... QF AU-200 mesh R2/2 grids (Quantifoil) were glow-discharged and placed into a 6-well tissue culture plate well containing 2 mL of cell culture medium for at least 1 h before cell seeding ...
-
bioRxiv - Biochemistry 2020Quote: ... 3.5 μl of this solution was adsorbed onto glow-discharged (PELCO EasiGlow, 15 mA, 0.39 mBar, 30 s) carbon-coated grids (200-400 mesh copper, Quantifoil) for 1 min at room temperature ...
-
bioRxiv - Biochemistry 2020Quote: ... at ∼0.3 mg/ml was applied to a 1.2/1.3 Quantifoil grid with continuous carbon support (Quantifoil Micro Tools GmbH), which had been glow discharged for 60 s at 15 mA ...
-
bioRxiv - Biochemistry 2020Quote: ... A volume of 3 μL of the sample was applied to a glow-discharged grid (Quantifoil R2/1 300 mesh) at 25 °C and 90 % humidity ...
-
bioRxiv - Biochemistry 2020Quote: ... 2.8 μl of the sample were applied onto the holey-carbon cryo-EM grids (Au R1.2/1.3, 300 mesh, Quantifoil), which were preliminary glow discharged at 5 mA for 30 s ...
-
bioRxiv - Biochemistry 2020Quote: ... 4 µL of sample was applied to Quantifoil Cu R 1.2/1.3 grids (Quantifoil Microtools GmbH) which has undergone a plasma discharge and were vitrified in liquid ethane using a Vitrobot MkIV plunge freezer (Thermo Fisher Scientific) ...
-
bioRxiv - Biochemistry 2020Quote: ... 3.5 μl of the peak fraction from gel filtration chromatography at ~1.0 mg/ml was also applied to the glow discharged 1.2/1.3 Quantifoil grids (Quantifoil Micro Tools Gmb). Grids were immediately plunge-frozen in liquid ethane using a Vitrobot Mark IV (ThermoFisher Scientific) ...
-
bioRxiv - Biochemistry 2020Quote: ... 3.5 μl of the freshly purified G614 sample in NP-40 at ~0.3 mg/ml was applied to a 1.2/1.3 Quantifoil grid with continuous carbon support (Quantifoil Micro Tools GmbH), which had been glow discharged with a PELCO easiGlow™ Glow Discharge Cleaning system (Ted Pella ...
-
bioRxiv - Biochemistry 2020Quote: ... the grids were prepared by applying 3 μl sample on glow-discharged holey carbon grids (Quantifoil Mo 2/2 200 mesh). The sample was ice-embedded using a LEICA EM GP2 (Leica Microsystems ...
-
bioRxiv - Biophysics 2020Quote: The cell suspension in sea water was seeded onto R 2/2 (SiO2) on Au G200F1 finder grids (Quantifoil Micro Tools GmbH, Germany) and incubated with filtered fresh sea water at 18 °C overnight ...
-
bioRxiv - Biophysics 2020Quote: Three microliters of purified HCoV-NL63 virions (4.5 mg/mL) were first applied to 300-mesh R2/1 + 2 nm C-film grids (Quantifoil) that had been glow-discharged for 15s PELCO easiGlow (TED PELLA ...
-
bioRxiv - Biophysics 2020Quote: ... and 3 μl of the diluted sample was applied onto glow-discharged R1.2/1.3 300 mesh UltrAuFoil gold grids (Quantifoil) for 30 s and then blotted for 5 s before plunge-freezing the grids into liquid ethane cooled by liquid nitrogen ...
-
bioRxiv - Biophysics 2020Quote: Purified GABAAR was incubated with ~1 μM Megabody-2524 and 3.5 μl sample was applied to glow discharged 300 mesh 1.2/1.3 and 2/2 UltraAuFoil gold grids (Quantifoil) for 30 s then blotted for 5.5 s prior to plunge-freezing with liquid ethane cooled by liquid nitrogen ...
-
bioRxiv - Biophysics 2020Quote: ... 0.2 mM ATP) and 4 μl were applied to glow-discharged 1.2/1.3 holey gold grids (Quantifoil) before plunge freezing in liquid ethane using a Vitrobot (FEI/Thermo Fisher Scientific ...
-
bioRxiv - Cell Biology 2020Quote: ... The MEFs were applied onto glow-discharged EM grids with a silicon-oxide support film (R1/4, Au mesh; Quantifoil, Jena, Germany). After incubation ...
-
bioRxiv - Biochemistry 2020Quote: ... holey carbon grids (Quantifoil R 1.2/1.3, Micro Tools GmbH, Germany). The grids were blotted for 4 seconds and vitrified by rapidly plunging into liquid ethane at −182 °C using Leica EM GP plunger (Leica Microsystems ...
-
bioRxiv - Biochemistry 2020Quote: ... 2.5 μL aliquots of purified Dnf1p–Lem3p or Dnf2p–Lem3p at a concentration of about 1.5 mg/mL were placed on glow-discharged holey carbon grids (Quantifoil Au R2/2, 300 mesh) and were flash-frozen in liquid ethane using a FEI Vitrobot Mark IV ...
-
bioRxiv - Biochemistry 2020Quote: ... Quantifoil 300 mesh gold grids (either 0.6/1 carbon film, 0.6/1 or 1.2/1.3 UltrAUfoil, Quantifoil Micro Tools GMBH) were glow discharged for 30 seconds prior to use ...
-
bioRxiv - Biochemistry 2020Quote: ... 3 µl of sample were applied to glow-discharged Quantifoil Au 2/2 holey carbon 200 mesh grids or Ultrafoil Au 2/2 holey gold 200 mesh grids (Quantifoil), and flash frozen in liquid ethane using an FEI Vitrobot Mark IV (Thermo Fisher Scientific ...