Labshake search
Citations for Quantifoil Micro Tools :
1051 - 1100 of 1446 citations since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biophysics 2021Quote: ... 3.5 μl of purified protein at a concentration of 1.0 mg/ml was applied to Graphene Oxide Au 400 mesh QUANTIFOIL R1.2/1.3 holey carbon grids (Quantifoil), and then plunged into liquid nitrogen-cooled liquid ethane with a FEI Vitrobot Mark IV (FEI Thermo Fisher) ...
-
bioRxiv - Biophysics 2021Quote: ... 3 μl of purified ghrelin-bound complex at 13 mg/ml and GHRP-6-bound ghrelin receptor complex at 8 mg/ml were applied individually onto a glow-discharged holey carbon grid (Quantifoil, Au300 R1.2/1.3) in a Vitrobot chamber (FEI Vitrobot Mark IV) ...
-
bioRxiv - Physiology 2021Quote: ... 3 µL of the vortexed dispersion were placed on glow discharged carbon-coated grids (Quantifoil, D) for 1 minute ...
-
bioRxiv - Biochemistry 2021Quote: The purified TIP39–PTH2R–Gs complex (3 μL at 8.5 mg per mL) was applied on a glow-discharged holey carbon grid (Quantifoil R1.2/1.3). Vitrification was performed using a Vitrobot Mark IV (ThermoFisher Scientific ...
-
bioRxiv - Immunology 2021Quote: ... was loaded onto plasma-cleaned Quantifoil R 2/1 (Cu, 400-mesh; Quantifoil Micro Tools GmbH) grids ...
-
bioRxiv - Biochemistry 2021Quote: ... 3.5 µl of the freshly purified sample from the peak fraction in DDM at ∼2.5 mg/ml for the Delta variant or ∼2.0 mg/ml for the Gamma and Kappa variants was applied to a 1.2/1.3 Quantifoil grid (Quantifoil Micro Tools GmbH), which had been glow discharged with a PELCO easiGlowTM Glow Discharge Cleaning system (Ted Pella ...
-
bioRxiv - Biochemistry 2021Quote: ... An aliquot of 3.5 μl of ~30 μM SOD1 fibril solution was applied to glow-discharged holey carbon grids (Quantifoil Cu R1.2/1.3, 300 mesh), blotted for 3.5 s and plunge-frozen in liquid ethane using an FEI Vitrobot Mark IV ...
-
bioRxiv - Biochemistry 2021Quote: 4 µl of 20-100 nM RZZSF filaments were deposited on freshly glow-discharged Formvar/Carbon (Quantifoil) film supported copper grid Cu400 (Sigma Aldrich ...
-
bioRxiv - Biochemistry 2021Quote: ... or 0.3 mg/ml for Au-foil grids (Quantifoil, Jena, DE). 4ul of sample was applied to glow-discharged grids ...
-
bioRxiv - Biochemistry 2021Quote: ... 3 μl was applied to a freshly glow-discharged grid (Quantifoil R0.6/1 Cu 300 mesh grid ...
-
bioRxiv - Biochemistry 2021Quote: ... 3.5 µl of purified COQ7-COQ9 complex was applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3, 400 mesh Cu) and incubated for an additional 30 s ...
-
bioRxiv - Biochemistry 2021Quote: ... A holey carbon film-coated copper grid (Quantifoil R1.2/1.3 Cu 200 mesh ...
-
bioRxiv - Biochemistry 2021Quote: ... The concentrated RyR2 was loaded onto a Quantifoil Cu/Rh grid (R1.2/1.3, 300 mesh) (Quantifoil), blotted using Vitrobot Mark III (FEI ...
-
bioRxiv - Biochemistry 2021Quote: ... 2.5+2.5µL of the samples were applied to glow-discharged UltraAuFoil 300 mesh R1.2/1.3 grids (Quantifoil) via double-sided application ...
-
bioRxiv - Biochemistry 2021Quote: Holey grids (gold, 200 mesh, r 2/2 by Quantifoil) were glow-discharged for 30 seconds using a Pelco glow discharge system ...
-
bioRxiv - Biochemistry 2021Quote: ... This sample was applied on 400 gold mesh Quantifoil R1.2/1.3 electron microscope grids (Quantifoil Micro Tools), freshly coated in house with an additional thin layer of carbon and glow discharged ...
-
bioRxiv - Biochemistry 2021Quote: ... Complexes were first diluted to 80 nM and aliquots of 2.5 μL were incubated for 30 sec on glow-discharged holey carbon grids with thin-layer carbon film (Quantifoil R1.2/1.3, 300 mesh, Copper). Grids were blotted for 3 sec in 100 % humidity at 4 °C and plunge frozen with a Vitrobot (FEI) ...
-
bioRxiv - Biochemistry 2021Quote: ... for the BsClpP pH 4.2 sample and negatively glow-discharged holey carbon grid (R 1.2/1.3 Quantifoil) for the BsClpP pH 6.5 sample ...
-
bioRxiv - Biochemistry 2021Quote: ... a 5 μl drop was applied to a graphene-treated and glow-discharged holey carbon grid (R 1.2/1.3 Quantifoil) for the BsClpP pH 4.2 sample and negatively glow-discharged holey carbon grid (R 1.2/1.3 Quantifoil ...
-
bioRxiv - Biochemistry 2021Quote: ... 1.8 uL of crystal slurry was applied to each side of a glow-discharged holey carbon grid (Quantifoil, R 2/1 200 mesh Cu ...
-
bioRxiv - Biochemistry 2021Quote: ... 2 uL of crystal slurry was applied to each side of a glow-discharged holey carbon grid (Quantifoil, R 2/1 200 mesh Cu ...
-
bioRxiv - Biochemistry 2021Quote: ... 2 uL of crystal slurry was applied to each side of a glow-discharged holey carbon grid (Quantifoil, R 1/4 300 mesh Cu ...
-
bioRxiv - Biochemistry 2021Quote: ... A freshly glow-discharged holey-carbon grid (QF R2/1 300 mesh, Quantifoil) was mounted to a Vitrobot cryoplunger (Thermo Fisher) ...
-
bioRxiv - Biochemistry 2021Quote: An aliquot of 2.5 microliters of purified drCALHM1 sample was applied onto a glow discharged holey carbon film grid (200 mesh, R2/1, Quantifoil). The grid was blotted and flash-frozen in liquid ethane with FEI Vitrobot Mark IV ...
-
bioRxiv - Biochemistry 2021Quote: ... 300 mesh R1.2/1.3 gold grids (Quantifoil, Großlöbichau, Germany) that were freshly glow discharged for 25 seconds ...
-
bioRxiv - Biochemistry 2021Quote: ... incubated in the presence or absence of 6.8 mM glutamate was adsorbed to glow-discharged holey carbon-coated grids (Quantifoil 300 mesh, Au R1.2/1.3) for 10s ...
-
bioRxiv - Immunology 2021Quote: ... Then 3 μl of the protein mixture was applied to a Quantifoil-Cu-2/1-3C grid (Quantifoil) pretreated by glow-discharging at 15 mA for 1 min ...
-
bioRxiv - Molecular Biology 2021Quote: ... The sample-covered carbon was then adsorbed to an EM grid (Quantifoil R3.5/1, Jena Bioscience) and blotted for 9 s using a Vitrobot Mark IV (ThermoFisher ...
-
bioRxiv - Biochemistry 2021Quote: ... 3.5 μL sample was applied onto a freshly glow-discharged 200-mesh copper 2 nm C R1.2/1.3 grids (Quantifoil Micro Tools). The grids were blotted for 1 s and plunge-vitrified in liquid ethane ...
-
bioRxiv - Biochemistry 2021Quote: ... 2.5 μL of selected elution fractions were applied to a 300-mesh holey carbon grid (Au 1.2/1.3, Quantifoil Micro Tools), blotted 2 s at 75 % humidity ...
-
bioRxiv - Biophysics 2021Quote: ... 300 mesh R 1.2/1.3 gold grids (Quantifoil, Großlöbichau, Germany). A FEI Vitrobot Mark IV (ThermoFisher Scientific ...
-
bioRxiv - Cell Biology 2021Quote: ... Aliquots (3.3 μL) of the S/2G1 complex were placed on glow-discharged holey carbon grids (Quantifoil Au R1.2/1.3). The grids were blotted for 2.5 s or 3.0 s and flash-frozen in liquid ethane cooled by liquid nitrogen with Vitrobot (Mark IV ...
-
bioRxiv - Cell Biology 2021Quote: ... 3μL sample (TRAPPII at 6.8mg/ml and TRAPPII-Rab11/Ypt32 at 5.5mg/ml) was applied to a plasma cleaned UltrAuFoil R1.2/1.3 (Quantifoil) grid inside a Vitrobot IV (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2021Quote: ... Three microliters of the protein solution were applied on a glow-discharged holey carbon grids (200 mesh Quantifoil R2/2 molybdenum), which had been treated with H2 and O2 mixtures in a Solarus plasma cleaner (Gatan ...
-
bioRxiv - Biochemistry 2021Quote: ... 1.2/1.3 µm 300 mesh holey grids (Quantifoil) were glow discharged for 20 s at 15 mA (PELCO easiGlow ...
-
Structure of mycobacterial cytochrome bcc in complex with Q203 and TB47, two anti-TB drug candidatesbioRxiv - Microbiology 2021Quote: 300-mesh Quantifoil R0.6/1.0 grids (Quantifoil, Micro Tools GmbH, Germany) were glow-discharged at H2/O2 atmosphere for 25s ...
-
bioRxiv - Biochemistry 2021Quote: ... 2.5 μL of freshly purified CasΦ3 R-loop complex (Absorbance260 nm of ~1.6) was applied to UltrAuFoil 300 mesh R0.6/1.0 holey grids (Quantifoil), glow-discharged for 60 s at 10 mA (Leica EM ACE200) ...
-
Mechanism of actin-dependent activation of nucleotidyl cyclase toxins from bacterial human pathogensbioRxiv - Biochemistry 2021Quote: ... were applied onto a freshly glow-discharged copper R2/1 300 mesh grid (Quantifoil), blotted for 3 s on both sides with blotting force −3 and plunge-frozen in liquid ethane using the Vitrobot Mark IV system (Thermo Fisher Scientific ...
-
Mechanism of actin-dependent activation of nucleotidyl cyclase toxins from bacterial human pathogensbioRxiv - Biochemistry 2021Quote: ... 3 μl of sample were applied onto a freshly glow-discharged copper R2/1 300 mesh grid (Quantifoil), blotted for 8 s on both sides with blotting force −20 and plunge-frozen in liquid ethane.
-
Mechanism of actin-dependent activation of nucleotidyl cyclase toxins from bacterial human pathogensbioRxiv - Biochemistry 2021Quote: ... the mixture was applied onto a freshly glow-discharged copper R2/1 300 mesh grid (Quantifoil), blotted for 3 s on both sides with blotting force −5 and plunge-frozen in liquid ethane using the Vitrobot Mark IV system (Thermo Fisher Scientific ...
-
bioRxiv - Biophysics 2021Quote: The ScBfr sample at concentration of 1.8 mg/ml was blotted (3.5□μl per blot) onto Au 300 mesh Quantifoil 1.2/1.3 grids (Quantifoil Micro Tools), and immediately plunge frozen using a Vitrobot (FEI) ...
-
bioRxiv - Biophysics 2021Quote: ... 3 μL was applied to Ultrafoil grids (R1.2/1.3, Au/Au, 300 mesh, Quantifoil Micro Tools GmbH) that had been glow-discharged for 2 min using a Pelco easiGlow (Ted Pella ...
-
bioRxiv - Neuroscience 2021Quote: Sample volumes of 3.5 µl were applied to freshly glow-discharged R3.5/1 holey carbon grids (Quantifoil) and vitrified using a Mark IV Vitrobot (Thermo Fischer Scientific ...
-
bioRxiv - Biophysics 2021Quote: ... except on a 300 mesh UltrAuFoil grid (Quantifoil R1.2/1.3) and imaged at a magnification of 165,000 (0.82 Å/pixel) ...
-
bioRxiv - Biophysics 2021Quote: ... 3.5 μL sample with addition of 0.05% β-OG was directly applied to glow-discharged 200 mesh gold grids (Quantifoil R1.2/1.3) and vitrified using a FEI Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Biochemistry 2021Quote: ... 3 μL of the PA-cAb29 complex were applied to the surface of each freshly glow-discharged Quantifoil R1.2/1.3 holey carbon grids (Quantifoil Micro Tools GmbH, Germany). Prior to plunge freezing ...
-
bioRxiv - Biophysics 2021Quote: Holey-carbon cryo-EM grids (Quantifoil Au R1.2/1.3, 300 mesh) were twice glow-discharged at 15 mA for 45 s ...
-
bioRxiv - Biophysics 2021Quote: ... 2.5 μL of each purified CCKAR–G protein complex was applied individually onto the glow-discharged holey carbon grids (Quantifoil, Au300 R1.2/1.3) in a Vitrobot chamber (FEI Vitrobot Mark IV) ...
-
bioRxiv - Biochemistry 2021Quote: For cryo-EM UltrAuFoil R 2.0/2.0 grids (Quantifoil, Germany) were negatively glow discharged using a PELCO Easiglow and coated with graphene oxide as described in Cheng et al. ...
-
bioRxiv - Biochemistry 2021Quote: ... Cryo-EM grids were prepared using glow discharged R2/2 Cu 200 mesh grids (Quantifoil) pre-floated onto custom-made 2.9 nm continuous carbon film ...