bioRxiv - Biochemistry 2022Quote: ... the postfusion S-nanodisc sample at 1.5 mg/ml was applied to a 1.2/1.3 Quantifoil gold grid (Quantifoil Micro Tools GmbH), which had been glow discharged with a PELCO easiGlow™ Glow Discharge Cleaning system (Ted Pella ...
-
bioRxiv - Cell Biology 2022Quote: ... Holey carbon grids (Quantifoil R1.2/1.3). The sample was blotted for 4-6 sec with filter paper at 8°C ...
-
bioRxiv - Biophysics 2022Quote: Holey carbon grids (Au R1.2/1.3 300 mesh) (Quantifoil Micro Tools, Germany) were glow-discharged using H2 and O2 for 60 s before being loaded with 2.5 μL purified CaV2.3 complex ...
-
bioRxiv - Biophysics 2022Quote: ... 2.5 μl of the complex were applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3 Au 200 mesh). Samples were blotted for 2-4 s at 4 °C and 100% humidity ...
-
bioRxiv - Biophysics 2022Quote: R1.2/1.3 300 mesh gold grids (Quantifoil) (Electron Microscopy Sciences ...
-
bioRxiv - Biophysics 2022Quote: ... and applied to the graphene oxide grid (Quantifoil Au 1.2/1.3, 300 mesh), which was glow-discharged (in a HARRICK PLASMA ...
-
bioRxiv - Cell Biology 2022Quote: ... 3 μL of ∼100 nM (A260 4.0 or 6.0) mitoribosome sample was applied onto a glow-discharged (20 mA for 30 sec) holey-carbon grid (Quantifoil R2/1 copper, mesh 300) coated with continuous carbon (of ∼3 nm thickness ...
-
bioRxiv - Immunology 2022Quote: ... 3.5 μl of each sample was applied to 1.2/1.3 UltrAuFoil grids (Quantifoil) which had been glow-discharged for 1 min at 15 mA in an EasiGlow (Pelco) ...
-
bioRxiv - Biochemistry 2022Quote: Templated CA (3.5 uL sample) was applied to a glow-discharged grid (QUANTIFOIL 300 mesh Au 1.2/1.3), then manually wicked away from the edge of the grid with a Kimwipe (Kimberly-Clark) ...
-
bioRxiv - Microbiology 2022Quote: ... holey-carbon Quantifoil grids (Quantifoil, Großlöbichau, Germany, Cat. #Q2100CR1) with holey carbon or gold GridFinder Quantifoil grids (Quantifoil ...
-
bioRxiv - Microbiology 2022Quote: ... with holey carbon or gold GridFinder Quantifoil grids (Quantifoil, Großlöbichau ...
-
bioRxiv - Biochemistry 2022Quote: 2.75 μL of purified OR51E2-Gs complex was applied to glow discharged 300 mesh R1.2/1.3 UltrAuFoil Holey gold support films (Quantifoil). Support films were plunge-frozen in liquid ethane using a Vitrobot Mark IV (Thermo Fisher ...
-
bioRxiv - Synthetic Biology 2021Quote: ... 25 mM Tris at pH 8.0 to a concentration of 2 mg/mL to a glow-discharged (1 min at 5 mA) holey carbon grid (Quantifoil Q225-CR1.3). This was followed by plunge-freezing in liquid ethane using an FEI Vitribot Mark IV (100% humidity ...
-
bioRxiv - Biophysics 2021Quote: ... A suspension containing a mixture of 10 nm protein A coated colloidal gold (Aurion) and Ebola VLPs was applied with a volume of 3 µl on a glow discharged EM grid (Quantifoil, 200 Mesh, R2/1). The grid was blotted using No.1 Whatman paper for 3 sec from the back-side in a chamber with controlled humidity set to 70% and the temperature set to 24°C.
-
bioRxiv - Biophysics 2021Quote: Gold EM grids with R1/4 holey SiO2 film (Quantifoil) were glow-discharged in a EasiGlow (Pelco ...
-
bioRxiv - Biophysics 2021Quote: 4 µL of purified HsPepT1 at 2 mg/mL was applied to a glow discharged gold holey carbon 2/1 300-mesh grid (Quantifoil). The grid was blotted for 4 s at 0 force before being plunge vitrified in liquid propane using a Mark IV Vitrobot (ThermoFisher) ...
-
bioRxiv - Biophysics 2021Quote: ... was applied to glow discharged gold holey carbon 2/1 300-mesh grids (Quantifoil). Grids were blotted for 4 s at 0 force and 2 s wait time before being plunge vitrified in liquid propane using a MarkIV Vitrobot (ThermoFisher) ...
-
bioRxiv - Biophysics 2021Quote: 3 μL aliquots of purified tau filaments from PSP human brain tissue (~0.006 mg/mL) were applied to glow-discharged holey carbon grids (Quantifoil Au R1.2/1.3, 300 mesh), blotted with filter paper and plunge-frozen into liquid ethane using an FEI Vitrobot Mark IV ...
-
bioRxiv - Biophysics 2021Quote: ... 4 μl of cell suspension was applied to holey carbon R2/1 Cu grids (Quantifoil) and plunge-frozen on a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biophysics 2021Quote: ... A volume of 4 μL cell suspension at a concentration of 3.07-3.5×107 cells/ml was directly applied to glow-discharged holey carbon R2/1 Cu 200 mesh grids (Quantifoil). After 5 s back-side blotting ...
-
bioRxiv - Biophysics 2021Quote: ... Log phase cultures were centrifuged at 2000 g for 2 minutes to concentrate the cells 10 times and 4 μl was directly applied to a glow-discharged holey carbon R2/1 Cu 200 mesh grid (Quantifoil). Plunge-freezing was performed using a VitroBot Mark 4 (Thermo Fisher Scientific ...
-
bioRxiv - Biophysics 2021Quote: ... with 12-nm-thick holey R1/4 and R1.2/20 SiO2 film (Quantifoil) were used for the experiments ...
-
bioRxiv - Biophysics 2021Quote: 3 μl of the human sperm sample were applied to glow discharged copper R2/2 200-mesh holey carbon grid (Quantifoil Micro Tools) and plunge frozen in liquid ethane using an automatic plunge freezer (Vitrobot ...
-
bioRxiv - Biophysics 2021Quote: ... 3 μL of the purified MC1R-Gs complex was applied to a glow-discharged holey carbon EM grid (Quantifoil, Au 300 R1.2/1.3) in a Vitrobot chamber (FEI Vitrobot Mark IV) ...
-
bioRxiv - Biophysics 2021Quote: ... before applying 4 µL of the solution to a glow-discharged (30s at 35 mA) copper R 2/2 200-mesh holey carbon grid (Quantifoil Micro Tools). The grids were blotted manually from the back side with Whatman filter paper #1 for 2-4 s ...
-
bioRxiv - Biophysics 2021Quote: Samples were diluted to 1 mg/ml and a total of 3.8 μl was applied to glow-discharged 300 mesh holey gold UltrAuFoil R1.2/1.3 grids (Quantifoil Micro Tools GmbH). Vitrification was conducted using a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biophysics 2021Quote: ... 2.5 μl of the complex were applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3 Au 200 mesh). Samples were blotted for 2-4 s at 4 °C and 100% humidity ...
-
bioRxiv - Biochemistry 2021Quote: ... 3 μL of the ATP13A2 sample were applied to a glow-discharged (PELCO easiGlow; 0.39 mBar, 25–30 mA, 40–45 s) gold holey carbon grid (Quantifoil R 1.2/1.3, 400 mesh). The grid was blotted for 3–4 s and plunge-frozen in liquid-nitrogen-cooled liquid ethane using Vitrobot Mark IV (FEI ...
-
bioRxiv - Biochemistry 2021Quote: ... 3 microlitres of undiluted eluate and of eluate which was diluted 1:2 or 1:4 in buffer A200 were blotted onto holey carbon R 1.2/1.3 copper 300 mesh grids (Quantifoil) and vitrified in liquid ethane using a Vitrobot MarkIV device (Thermofisher) ...
-
bioRxiv - Biochemistry 2021Quote: ... applied to 300-mesh carbon coated (2nm thickness) holey carbon Quantifoil 2/2 grids (Quantifoil Micro Tools) and flash-frozen as described in (Khatter et al. ...
-
bioRxiv - Microbiology 2021Quote: ... before being vitrified on carbon-coated Au grids (R06/1, 200 mesh; Quantifoil, Jena, Germany).
-
bioRxiv - Microbiology 2021Quote: ... coated with a carbon mesh (R2/1, 200 mesh; Quantifoil, Jena, Germany).
-
bioRxiv - Microbiology 2021Quote: ... and 5 μl of the washed cells were introduced to Au grids (R2/1, 200 mesh; Quantifoil). The grids were fixed in 4% PFA (in TBS ...
-
bioRxiv - Microbiology 2021Quote: ... coated with a carbon mesh (R2/1, 200 mesh; Quantifoil, Jena, Germany). The grids were manually blotted for ~4-5 s from the reverse side and plunge frozen in liquid ethane by using an in-house plunger.
-
bioRxiv - Biophysics 2021Quote: ... 2.5 µl aliquots of ribosomal complexes were incubated for 30 seconds on glow-discharged Holley carbon grids with a thin-layer carbon film cover (Quantifoil). Grids were blotted using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Molecular Biology 2021Quote: ... 4 μl of protein sample (about 0.73 mg/ml) was applied onto a glow-discharged holey carbon grid (Quantifoil Au, R2/2, 300 mesh). After blotting for 3 s ...
-
bioRxiv - Molecular Biology 2021Quote: Copper grids with holey carbon support film (R3/3, Quantifoil) and a 2 nm pre-coated continuous carbon layer on top were glow discharged at 2.2 × 10-1 mbar for 20 s ...
-
bioRxiv - Molecular Biology 2021Quote: ... a 3.5 μL aliquot at 0.1 mg·ml−1 was applied to one side of a Quantifoil 400 mesh 1.2/1.3 gold grid with graphene oxide support film (Quantifoil). After 30 s ...
-
bioRxiv - Biochemistry 2021Quote: ... 2.8 μl of the sample was applied onto the holey-carbon cryo-EM grids (Au R1.2/1.3, 300 mesh, Quantifoil), which were prior glow discharged at 5 - 15 mA for 30 s ...
-
bioRxiv - Neuroscience 2021Quote: ... 300 mesh R 1.2/1.3 gold grids (Quantifoil). Samples were plunge frozen in liquid nitrogen cooled liquid ethane using a FEI Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Neuroscience 2021Quote: Quantifoil 200-mesh 1.2/1.3 grids (Quantifoil) were plasma cleaned for 30 s in an air mixture in a Solarus Plasma Cleaner (Gatan) ...
-
bioRxiv - Molecular Biology 2021Quote: ... bremelanotide– or THIQ–bound MC4R–Gs complexes at ∼ 4 mg/mL were applied onto glow-discharged holey carbon grids (Quantifoil R1.2/1.3). Excess samples were blotted away and the grids were vitrified by plunging into liquid ethane using a Vitrobot Mark IV (ThermoFischer Scientific).
-
bioRxiv - Molecular Biology 2021Quote: 1.2/1.3 UltrAuFoil (Quantifoil) grids (Russo and Passmore ...
-
bioRxiv - Molecular Biology 2021Quote: ... Quantifoil R1.2/1.3 300 mesh copper grids (Quantifoil) were covered with an amorphous carbon layer prepared in-house ...
-
bioRxiv - Molecular Biology 2021Quote: ... 4 μl of protein sample (about 1.5 mg/ml) was applied onto a glow-discharged holey carbon grid (Quantifoil Au, R1.2/1.3, 300 mesh). At a temperature of 4°C and under a humidity of 100% ...
-
bioRxiv - Molecular Biology 2021Quote: The freshly purified complexes (3.0 μL) at a final concentration of 17 mg/mL were applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3, 200 mesh), and subsequently vitrified using a Vitrobot Mark IV (ThermoFisher Scientific) ...
-
bioRxiv - Molecular Biology 2021Quote: ... 200 mesh Cu grid (Quantifoil Micro Tools GmbH, Jena, Germany), and incubated prior to blotting (30s for Vibrio cholerae or 10s for ICP1 ...
-
bioRxiv - Molecular Biology 2021Quote: ... 3 μL aliquots of the cell suspension were applied to glow-discharged R2/2 200 mesh copper Quantifoil grids (Quantifoil Micro Tools), the sample was pre-blotted for 30 seconds ...
-
bioRxiv - Molecular Biology 2021Quote: ... 200 mesh copper Quantifoil grid (Quantifoil Micro Tools) in an FEI Vitrobot chamber with 100% humidity ...
-