Labshake search
Citations for Beckman :
1301 - 1350 of 1603 citations for tert Butyl trans 17 bromo 4 7 10 13 tetraoxa 15 heptadecenoate since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2022Quote: ... The supernatant was again centrifuged at 100000 g for 45 min at 4°C (Beckman Optima™ MAX-XP Rotor MLS-50). After filtering the supernatant through a 0.22 μm syringe filter ...
-
bioRxiv - Cell Biology 2022Quote: ... One milliliter of concentrated conditioned medium was pipetted on top of the gradient and samples were centrifuged for 18 h at 100,000 ×g and 4 °C using a SW 32.1 Ti rotor (Beckman Coulter, Fullerton, California, USA). Fractions of 1 mL were collected from the top and EV-rich fractions 9 and 10 (corresponding to a density of 1.10-1.12 g/mL ...
-
bioRxiv - Biochemistry 2023Quote: ... Cultures were then recovered by centrifugation (4,000 x g, 4 °C, 40 min in a Beckman Avanti JXN-26 (rotor: JLA 8.1)) and pellets resuspended in approximatively 30 mL of lysis buffer (20 mM HEPES ...
-
bioRxiv - Molecular Biology 2024Quote: ... ADEV isolation was performed by ultracentrifugation at 100,000 × g for 14 h at 4 °C (swing bucket rotor on minimum acceleration/break setting, SW 32Ti Beckman Coulter, Brea, CA), and ADEVs were resuspended in 200μL PBS and stored at −20°C until used16,41 ...
-
bioRxiv - Cell Biology 2024Quote: ... All centrifugation steps were done at 4°C and the last two steps were performed using Optima XE-90 ultracentrifuge (Beckman Coulter, A94471) with rotor SW32Ti (Beckman Coulter ...
-
bioRxiv - Cell Biology 2024Quote: ... and cells were isolated by centrifugation at 500 g for 5 min at 4°C followed by being treated with a red blood lysis buffer (Beckman Coulter, USA). After washing with PBS ...
-
bioRxiv - Immunology 2023Quote: ... Bacteria cultures were collected and discarded by centrifugation for 60 min at 4,000-8,000 x g and the supernatants were subjected to high-speed centrifugation at 11,9000 x g for 2-3 h at 4°C (Beckman Coulter Optima Ultracentrifuge). The pellets containing the OMVs were washed with PBS ...
-
bioRxiv - Biochemistry 2023Quote: ... by centrifugation at 80,000 × g for 30 min at 4°C using a TLS-55 rotor (Beckman Coulter Inc., Miami, FL, USA). Crista membranes were identified and removed based on fluorescence under a UV lamp ...
-
bioRxiv - Cell Biology 2023Quote: ... Following centrifugation at 131,300 × g for 24 hr at 4 °C using a MLS-50 Swinging-Bucket rotor (Beckman Coulter, Brea, CA) to sediment protein complexes ...
-
bioRxiv - Cell Biology 2022Quote: ... The resulting supernatant was centrifuged at 10,000 x g for 30 minutes to remove any remaining debris and then ultra-centrifuged at 118,000 x g for 70 minutes at 4°C with a fixed-angle rotor (Ti-70, Beckman Coulter, Brea, CA). The pellet was washed with sterile 1X PBS and subjected to another cycle of ultracentrifugation at 118,000 x g for 70 minutes at 4°C ...
-
bioRxiv - Cancer Biology 2022Quote: ... The supernatants were further centrifuged at 10,000 × g for 30 min at 4°C to remove remaining cell debris and at 100,000 × g (Type 90 Ti Rotor, Beckman, Brea, CA, USA) overnight at 4°C to remove exosomes ...
-
bioRxiv - Biochemistry 2022Quote: ... Triton-X was added to the lysate to a final concentration of 0.1% and clarified by spinning at 15,000 RCF at 4°C for 45 minutes (Beckman Coulter JA-20 rotor). The supernatant was loaded onto a 5 mL HisTrap™ FF crude column (GE Healthcare ...
-
bioRxiv - Molecular Biology 2023Quote: ... The cell lysate was centrifuged at 4 °C at 35000 rpm for 1 hour with Beckman Optima™ L-80XP Ultracentrifuge equipped with Ti45 rotor (Beckman, USA). The pellet containing membranes and cell debris was discarded ...
-
Isolation and characterization of a novel phage of Vibrio parahaemolyticus with biocontrol potentialbioRxiv - Microbiology 2022Quote: ... for purification and centrifuged at 200,000 × g at 4°C for 24 h using an Optima L-100 XP ultracentrifuge (Beckman Coulter, CA, USA). The purified phage particles were dialyzed through 30-kDa superfilters (Millipore ...
-
bioRxiv - Neuroscience 2023Quote: ... re-suspend in the homogenization buffer and centrifuged at 100,000 x g for 40 min at 4°C (Beckman SWTi41 swing rotor). The pellet containing the growth cone were re-suspended in 50 μl of the homogenization buffer ...
-
bioRxiv - Cell Biology 2023Quote: ... was next subjected to ultracentrifugation at 120,000 × g for 4 h in a SW 28 Ti Swinging-Bucket Rotor (Beckman Coulter, Fullerton, CA) to sediment small EVs ...
-
bioRxiv - Plant Biology 2023Quote: ... 700 μl of obtained extract was applied to a chilled sucrose density gradient and centrifuged at 4 °C for 2 hours 45 minutes at 151,000 ×g using the SW 41 Ti rotor (Beckman Culture Life Sciences). After centrifugation ...
-
bioRxiv - Biochemistry 2023Quote: ... Triton-X was added to the lysate to a final concentration of 0.1% and clarified by spinning at 15,000 RCF at 4°C for 45 minutes (Beckman Coulter JA-20 rotor). The supernatant was loaded onto a 5 mL HisTrap™ FF crude column (GE Healthcare ...
-
bioRxiv - Cell Biology 2023Quote: ... the supernatants were transferred into SW60 tubes (in vivo studies 1–4) or SW40 tubes (donated patients) (Beckman Coulter Inc., Brea, USA) and centrifuged at 10,000xg for 35 minutes ...
-
bioRxiv - Molecular Biology 2023Quote: ... The lysates were loaded onto the sucrose gradients and centrifuged at 40’000 rpm for 2 h at 4°C using the SW 41 Ti rotor (Beckman Coulter, Cat# 331362). Subsequently ...
-
bioRxiv - Biochemistry 2023Quote: ... Samples were centrifuged at 100,000 × g for 2 hr at 4 °C (Type 50.2 Ti Fixed angle ultracentrifuge rotor, Beckman Coulter, Brea, CA, USA). The supernatants were aspirated ...
-
bioRxiv - Biophysics 2024Quote: ... Samples were centrifuged at 24,000 rotations per minute using an S-28 rotor at 4◦C in an Optima XL-100K Ultracentrifuge (Beckman Coulter, Brea, CA). The supernatant was decanted ...
-
bioRxiv - Developmental Biology 2024Quote: ... for 30 min at 4°C in the dark followed by flow cytometry analysis on a CytoFlex 26 (Beckman Coulter, Indianapolis, IN) in PE-A and PerCP-A channels ...
-
bioRxiv - Molecular Biology 2024Quote: ... was loaded on top of the gradient and spun at 4°C for 18 hr at 30,000 rpm (Beckman, Rotor SW-41Ti). Samples were fractionated with absorbance optics (λ = 260 nm ...
-
bioRxiv - Neuroscience 2024Quote: ... The PNS- Nycodenz gradient was centrifuged for 1 h at 141,000 x g at 4°C (46,000 rpm, TLS-55 rotor, Beckman Coulter Optima TLX Ultracentrifuge). After centrifugation ...
-
bioRxiv - Neuroscience 2024Quote: ... This gradient was centrifuged for 30 minutes at 72,000 x g at 4°C (33,000 rpm, TLS-55 rotor, Beckman Coulter Optima TLX Ultracentrifuge). After centrifugation ...
-
bioRxiv - Microbiology 2024Quote: ... Crude ribosomes were separated from other low molecular weight cellular contents by centrifugation at 35000 rpm (126,000g) for 1 hour at 4 °C (Beckman rotor Type 70Ti). The crude ribosome pellet was resuspended in 10 mL HMA-10 buffer and layered on top of a 10 mL 32% sucrose solution in HMA-10 buffer and centrifuged for 16 hours at 37,000 rpm (140,000g ...
-
bioRxiv - Neuroscience 2024Quote: ... The supernatant was segregated subsequent to centrifuging the brain tissue homogenate for 1 h at 100,000g and 4°C utilising an ultra-high-speed centrifuge (Beckman, Optima MAX-XP). The tissue residue was then reprocessed ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: The number of μPL per PVA template and size distribution were derived via a Multisizer 4 COULTER particle counter (Beckman Coulter, CA). Briefly ...
-
bioRxiv - Neuroscience 2024Quote: ... The suspension was then centrifuged at 2500 × g for 30 min at 4 °C and the supernatant was transferred to an ultra-centrifugation tube (Quickseal Tubes, Beckman Coulter #342414). AAV purification was performed by ultra-centrifugation over a discontinuous Iodixanol density gradient (OptiPrep Density Gradient Medium ...
-
bioRxiv - Plant Biology 2024Quote: ... The resulting supernatant was centrifuged at 200,000 x g for 30 minutes at 4 °C using a Beckman Optima Ultracentrifuge with TLA110 rotor (Beckman Coulter Life Sciences). The pellet was resuspended in 30 µL of cold ddH20 and stored in −80 °C until further use.
-
bioRxiv - Biochemistry 2024Quote: ... Purified nucleosome arrays were subsequently isolated on 5-40% w/v sucrose gradients in 0.5X TE by centrifuging the gradients at 39,000 rpm and 4°C for 8 h in a SW41 Ti rotor (Beckman Coulter, Brea, CA). After centrifugation ...
-
bioRxiv - Cell Biology 2024Quote: ... The crude pellets from MSC-CM and HDF-CM after the first-round 100,000 × g ultracentrifugation were washed with PBS at 100,000 × g and 4 ℃ for 45 min using Optima™ MAX-TL Ultracentrifuge (Beckman Coulter, USA) and TLA-120.2 Rotor (Beckman Coulter ...
-
bioRxiv - Cell Biology 2020Quote: ... Cells were harvested by centrifugation at 4,000rpm in a JA-10 fixed angle rotor (Beckman Coulter). Pellets were resuspended in lysis buffer containing 50 mM Tris ...
-
bioRxiv - Biochemistry 2021Quote: ... using 1-10 ng DNA and libraries were size selected with AMPure XP beads (Beckman Coulter). Illumina 50 bp single-end read sequencing was performed on a NextSeq 500 or NovaSeq 6000 ...
-
bioRxiv - Biochemistry 2020Quote: ... The microtubules were pelleted at 90,000 rpm for 10 min at 37°C (TLA120.1 Beckman Coulter) and re-suspended in warm (37°C ...
-
bioRxiv - Physiology 2024Quote: ... The entire contents of a well were added to 10 mL of Isoton Buffer (Beckman Coulter) and particle diameter measured using a Multisizer 3 Coulter Counter (Beckman Coulter) ...
-
bioRxiv - Microbiology 2023Quote: ... 50 ml of cell culture was harvested by centrifugation for 10 min at 3000 xg (Beckman Coulter Allegra X30-R Centrifuge ...
-
bioRxiv - Cancer Biology 2023Quote: ... 10% of the lysate was used to extract DNA by AMPure SPRI beads (Beckman Coulter, A63881) and chromatin digestion was verified by resolving on 2% Agarose gel ...
-
bioRxiv - Microbiology 2023Quote: ... The tubes were centrifuged at 3750 × g for 10 min (Allegra X-12R, Beckman Coulter, USA) to obtain coral tissue pellets ...
-
bioRxiv - Cell Biology 2022Quote: Pseudovirus samples were concentrated 10 to 20 times by ultracentrifugation (Optima MAX-XP Ultracentrifuge; Beckman Coulter) for 30 min ...
-
bioRxiv - Molecular Biology 2024Quote: ... The pools were cleaned using 10% of Illustra ExoProStar (Cytiva) and AMPure XP Beads (Beckman Coulter) (0.8X ratio COI ...
-
bioRxiv - Genomics 2024Quote: ... 10 µL per reaction was pooled and purified using 0.8x AMPur-eXP bead purification (Beckman Coulter). 1 µg of purified DNA per sample was used to prepare sequencing libraries ...
-
bioRxiv - Microbiology 2020Quote: ... by ultra-centrifugation in a Beckman L7-65 ultracentrifuge at 25,000 rpm for two hours at 4°C using a Beckman SW28 rotor (Beckman Coulter, Brea, CA, USA). Supernatants were aspirated off and the pellets were re-suspended in PBS (pH 7.4) ...
-
bioRxiv - Microbiology 2020Quote: ... by centrifugation in a Beckman L7-65 ultracentrifuge at 25,000 rpm for 2h at 4°C using a Beckman SW28 rotor (Beckman Coulter, Brea, CA, USA). Supernatants were aspirated and the pellets were re-suspended in PBS (pH 7.4) ...
-
bioRxiv - Molecular Biology 2021Quote: ... The centrifugation is performed on a SW60Ti rotor at 40 000 g for 22 minutes at 4°C (Beckman Optima L-90K Ultracentrifuge). The mitochondrial fraction (400µL ...
-
bioRxiv - Molecular Biology 2020Quote: ... and plasma was separated by centrifugation (2,000 × g, 20 min, 4 °C) in a Microfuge 20R (cat. no. B30149, Beckman Coulter, Brea, CA, USA). Plasma was transferred to new 1.5 mL microcentrifuge tubes and further clarified by centrifugation (10,000 × g ...
-
bioRxiv - Biophysics 2022Quote: ... shortly sonified and centrifuged for 30 min at 100 000 g at 4°C (Centrifuge Beckman Coulter Optima XPN-80, Rotor type 70.1).) ...
-
bioRxiv - Biophysics 2022Quote: ... The samples were centrifuged for 30 min at 100 000 g at 4°C (Centrifuge Beckman Coulter Optima XPN-80, Rotor type 70.1). The supernatant ...
-
bioRxiv - Biochemistry 2020Quote: ... Unbroken cells were pelleted by centrifugation at 18,000 RCF for 30 min at 4°C (Beckman centrifuge J-20-XP, Rotor JA16.250, DE). The supernatant was transferred to 45 TI rotor (Beckman ...