Labshake search
Citations for GE Life Sciences :
1401 - 1450 of 4827 citations for 7 Methyl 1 5 dioxo 1 2 3 5 tetrahydro indolizine 6 carbonitrile since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2019Quote: ... then supernatants were filtered (0.45 μm syringe filter, Iwaki) prior to purification on 5 ml HiTrap Chelating HP columns (GE Healthcare). Recombinant proteins were routinely purified by fast protein liquid chromatography (FPLC ...
-
bioRxiv - Cell Biology 2019Quote: HEK-293T were obtained from ATCC and cultured at 37°C and 5% CO2 in high-glucose DMEM (GE Healthcare) supplemented with 10% FBS (Atlanta Biologicals) ...
-
bioRxiv - Cell Biology 2020Quote: siRNA-mediated knockdown in 786-O cells was carried out using 5-10 nM Dharmacon ON-TARGETplus siRNAs (GE Healthcare), diluted in siRNA buffer and mixed with DharmaFECT transfection reagent (1:50 in optiMEM reduced serum media) ...
-
bioRxiv - Cell Biology 2019Quote: ... 5-10 μg proteins were resolved by SDS-polyacrylamide gel electrophoresis (SDS-PAGE) and transferred onto nitrocellulose membranes (GE Healthcare). To visualize MLKL oligomers ...
-
bioRxiv - Genetics 2019Quote: ... 20 μg of PCR products was immobilized to 5 μl Streptavidin Sepharose High Performance Bead (GE Healthcare, Piscataway, NJ, USA), and subsequently annealed to 1 μl sequencing primer (5 μM ...
-
bioRxiv - Developmental Biology 2020Quote: ... the supernatant was boiled at 98 °C for 5 min, applied to SDS page gel (SuperSep, WAKO) and transferred onto a 0.2 µM nitrocellulose blotting membrane (GE Healthcare). After incubation with blocking buffer (5% milk in tris-buffered saline with 0.1% Tween20 ...
-
bioRxiv - Cancer Biology 2019Quote: ... the lysate spun down at 12,000 x g for 30 min and then loaded onto a 5 ml His-Trap Crude FF column (GE Healthcare) using a ÄKTA Purifier protein purification system (GE Healthcare) ...
-
bioRxiv - Genomics 2020Quote: ... 20 µl PCR products were subsequently immobilized to 5 µl Streptavidin Sepharose High Performance Bead (GE Healthcare, Piscataway, NJ, USA), and then were finally annealed to 1 µl sequencing primer (5 μM ...
-
bioRxiv - Microbiology 2021Quote: ... The resulting lysate was centrifuged for 30 minutes at 20,000 rpm to remove cell debris and the supernatant was filtered with a 0.45 μm filter before loading onto an equilibrated 5 ml His Trap HP column (GE healthcare) connected to an ÄKTA pure 25 system ...
-
bioRxiv - Biochemistry 2020Quote: ... The suspension of solubilized protein was ultracentrifuged at 100,000 × g for 1h before being loaded onto a 5 ml HisTrap HP column (GE HealthCare). The column was washed with buffer containing 20 mM Tris-Cl ...
-
bioRxiv - Bioengineering 2021Quote: The yielded supernatant was passed through a 0.2 μm filter and loaded with a flow rate of 0.5 mL/min on a 5 mL HisTrap HP column (GE Healthcare) equilibrated with 12 CV binding buffer ...
-
bioRxiv - Biochemistry 2021Quote: ... The periplasmic extract was adjusted to 50 mM Tris/HCl pH 9.0 (loading buffer) and loaded onto a 5 mL Q Sepharose anion exchange column (GE Healthcare). Proteins were eluted using a linear salt gradient (0-500 mM NaCl ...
-
bioRxiv - Biochemistry 2021Quote: ... peak fractions were diluted to 100 mM NaCl and loaded onto a 5 ml HiTrap Q XL column (GE Healthcare) equilibrated in 50 mM HEPES pH 7.3 ...
-
bioRxiv - Biochemistry 2020Quote: ... The clarified supernatant containing the protein was loaded on a 5 mL HiTrap Ni-chelating column (GE Healthcare, Piscataway, NJ), washed ...
-
bioRxiv - Biophysics 2021Quote: ... Pooled eluate fractions were adjusted to 150 mM NaCl and purified on a 5 ml HiTrap Heparin column (GE Healthcare) using a linear gradient from 150 mM NaCl to 1 M NaCl in buffer A ...
-
bioRxiv - Neuroscience 2020Quote: ... and 5 μL of Amersham ECL Rainbow Marker was loaded as a molecular weight standard (GE Life Sciences, Pittsburgh, PA). Proteins were transferred onto nitrocellulose and incubated with primary antibody ...
-
bioRxiv - Biophysics 2021Quote: ... nickel affinity chromatography was performed where the lysate was loaded onto a 5 mL HisTrap™ Excel column (GE Healthcare), followed by a wash with 20 column volumes (CV ...
-
bioRxiv - Biochemistry 2021Quote: Single cysteine mutants of ColE9 or the ColE9 DNase domain were desalted on a 5 ml HiTrap column (GE Healthcare) equilibrated with binding buffer (20 mM potassium phosphate pH 7 ...
-
bioRxiv - Biochemistry 2021Quote: ... The soluble cell lysate obtained after centrifugation was loaded onto a 5 ml HisTrap FF HP nickel column (GE Healthcare) equilibrated with binding buffer ...
-
bioRxiv - Biochemistry 2021Quote: ... Lysates were clarified by centrifugation (15,000 g for 40 min at 4 °C) and incubated with 5 mL glutathione Sepharose 4B (GE Healthcare) for 1.5 hr at 4 °C with gentle shaking ...
-
bioRxiv - Biochemistry 2020Quote: ... The co-expressed complex of ctCyclin H and ctMAT1short was loaded on a 5 ml StrepTrap HP column (GE Healthcare) equilibrated in lysis buffer B (20 mM HEPES pH 7.5 ...
-
bioRxiv - Cell Biology 2021Quote: ... The cell lysate was centrifuged at 38,000 ×g and the supernatant was loaded onto a 5 mL HisTrap Ni-NTA column (GE Healthcare). The column was washed with HisTrap Buffer and protein eluted with a linear gradient of imidazole from 25 to 300 mM in HisTrap Buffer over 10 column volumes.
-
bioRxiv - Systems Biology 2021Quote: ... The supernatants obtained after this step were loaded in 5-mL His-trap columns (GE Healthcare Systems, Chicago, IL, USA) pre-equilibrated with buffer A supplemented with 100 mM NaCl and 20 mM imidazole ...
-
bioRxiv - Biochemistry 2020Quote: ... The supernatant was filtrated through a O.22μm pore filter and loaded on a 5 ml pre-packed Hitrap Q FF column (GE Healthcare) equilibrated with buffer A (50mM bis-tris-HCI pH 6.0 ...
-
bioRxiv - Microbiology 2021Quote: ... The solution was centrifuged for 30 min at 38,000 × g and 4°C to remove precipitates and applied onto a 5 mL HisTrap HP column (GE Healthcare) equilibrated with buffer ParB3 ...
-
bioRxiv - Microbiology 2021Quote: ... and the supernatant was subjected to immobilized-metal affinity chromatography (IMAC) using a 5 mL HisTrap HP column (GE Healthcare) equilibrated with buffer ParB1 containing 20 mM imidazole ...
-
bioRxiv - Molecular Biology 2020Quote: ... Cell debris was removed by centrifugation for 30 min at 47,000 xg and the supernatant was loaded onto a 5 ml GSTrap column (GE Healthcare). The resin was washed by the lysis buffer and bound protein was eluted with elution buffer of 100 mM Tris-HCl ...
-
bioRxiv - Immunology 2021Quote: ... Human IgGs were isolated from heat-inactivated plasma samples using 5-mL HiTrap MabSelect SuRe columns (GE Healthcare Life Sciences) as described (24).
-
bioRxiv - Microbiology 2019Quote: ... fumigatus pksP mutant conidia with an MOI of 10 or 5 in HBSS with Ca2+ and Mg2+ (HyClone, GE Healthcare) on a linear shaker (100 rpm ...
-
bioRxiv - Cell Biology 2021Quote: ... The lysate was cleared by centrifugation and it was applied to a 5 ml GSTrap FF column (GE Healthcare, 17513101) to purify GST-proteins ...
-
bioRxiv - Cell Biology 2021Quote: ... His-Bro1ΔAPRR purified from BL21-DE3 using Ni2+-affinity chromatography (5 ml HiTrap Chelating FF column; GE Healthcare, United Kingdom). GST-Bro1V(370-709 ...
-
bioRxiv - Biophysics 2021Quote: ... The lysate was cleared by two rounds of 20 min centrifugation at 45,000 x g at 4°C and loaded onto a 5-mL HisTrap column (GE Healthcare) pre-equilibrated with buffer A ...
-
bioRxiv - Biochemistry 2022Quote: ... The supernatant was consecutively filtered through 0.45 µm and 0.22 µm PES syringe filters prior to loading onto a 5 ml HisTrap nickel affinity column (GE Healthcare) preequilibrated with Buffer A ...
-
bioRxiv - Biochemistry 2022Quote: ... the affinity-purified Pvs25 protein was applied to hydrophobic interaction chromatography (HIC) (HiTrap Phenyl HP; 5 mL resin, GE Healthcare) In detail ...
-
bioRxiv - Cell Biology 2022Quote: ... The supernatant was applied to a 5-ml His-Trap HF column charged with NiCl2 (GE Healthcare, 17-5248-02). GFP-NONO_WT or GFP-NONO_ΔRRM1 was eluted at room temperature with an imidazole gradient (25-500 mM ...
-
bioRxiv - Biochemistry 2022Quote: ... The eluate of HIC-EBA was subjected to affinity chromatography using Strep-Tactin® column (5 ml cartridge, GE Healthcare Life Science ...
-
bioRxiv - Molecular Biology 2022Quote: ... the supernatant of the lysate was filtered through a 0.22 µm membrane filter and loaded onto a Ni-NTA column (HiTrap, 5 ml, GE Healthcare) using a low imidazole buffer (Buffer C ...
-
bioRxiv - Microbiology 2022Quote: ... The supernatant was filtered using a 0.2 μl filter and flown over a 5 ml NiNTA IMAC column (GE Healthcare) equilibrated with buffer A (50 mM KH2PO4 pH 7 ...
-
bioRxiv - Microbiology 2022Quote: ... The supernatant was filtered using a 0.2 μl filter and flown over a 5 ml StrepTactin-Sepharose column (GE Healthcare) equilibrated with buffer A (50 mM MES-NaOH ...
-
bioRxiv - Microbiology 2022Quote: ... and the supernatant was filtered using a 0.2 μl filter and flown over a 5 ml NiNTA Immobilised Metal Affinity Chromatography (IMAC) column (GE Healthcare) equilibrated with buffer A (25 mM HEPES pH 7.5 ...
-
bioRxiv - Biophysics 2022Quote: ... The lysate was centrifuged and the supernatant was filtered through a 0.45 μm filter and subjected to a His-tag affinity chromatography using a 5 mL HisTrapFF (GE Healthcare) and the ÄKTAprime plus system (GE Healthcare) ...
-
bioRxiv - Biophysics 2022Quote: ... The sample was exchanged into the D2O buffer using a NAP-5 Sephadex G-25 column (GE Healthcare, Chicago, IL). For dUMP and TMP (Sigma-Aldrich ...
-
bioRxiv - Biophysics 2022Quote: ... The lysate was supplemented with 50 mM imidazole and loaded onto a 5 mL His-Trap FF column (GE Healthcare), washed with 6 column volumes (CV ...
-
bioRxiv - Bioengineering 2022Quote: ... the supernatant was filtered using 0.2 μm filters and buffer exchanged in storage buffer (20 mM Tris-HCl pH7.4, 200 mM NaCl and 5% glycerol) using PD-10 desalting columns (GE healthcare). The desalted sample then was aliquoted and stored at -80°C until the one-step purification/ immobilisation.
-
bioRxiv - Immunology 2020Quote: ... Lysates were centrifuged at 15,000xg for 5 min and supernatants were incubated with 50 μL of Streptavidin Sepharose High Performance beads (GE Healthcare) for 1 h rotating ...
-
bioRxiv - Biochemistry 2021Quote: ... 5 mL imidazol gradient) or by size exclusion chromatography (SEC) using a Superdex® 75 10/300 GL (GE Healthcare) with a flow rate of 0.5 mL/min and dialysis buffer as running buffer ...
-
bioRxiv - Microbiology 2021Quote: ... The cleared supernatant was filtered using a 0.2 μM filter and loaded onto a 5 ml HisTrap HP Ni-affinity column (GE Healthcare). Protein was eluted in a gradient of 10 to 300 mM imidazole over five column volumes ...
-
bioRxiv - Microbiology 2020Quote: ... Bacteria were pelleted and lysed by sonication in lysis buffer (Tris 100mM, NaCl 0.5M, glycerol 5%) and eGFP was purified using fast flow His-affinity columns (GE Healthcare) and eluted with 500 mM imidazole ...
-
bioRxiv - Biochemistry 2021Quote: ... The supernatant was filtered through a 0.45-μm membrane and loaded onto a HisTrap FF 5 mL column (GE Healthcare) pre-equilibrated with buffer A ...
-
bioRxiv - Biophysics 2021Quote: ... Lysate was cooled down on ice and ultracentrifugated at 160,000xg for 1hr at 4°C and loaded onto a 5 mL Protein A (GE Healthcare) column equilibrated with PBS ...