Labshake search
Citations for Quantifoil Micro Tools :
201 - 250 of 607 citations for R 4 5 Isopropylidene 2 pentanoic acid since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2020Quote: ... or Quantifoil R2/2 (Quantifoil, Germany). The samples were cryo-fixed by plunge freezing at −180°C in liquid ethane using a Leica EMGP (Leica ...
-
bioRxiv - Microbiology 2022Quote: ... we used R2/2 grids (Quantifoil) coated with a thin layer of 0.2 mg/ml graphene oxide ...
-
Cryo-electron tomography of eel sperm flagella reveals a molecular “minimum system” for motile ciliabioRxiv - Cell Biology 2023Quote: ... holey carbon grids (Quantifoil R2/2) were glow discharged for 30 seconds in a Pelco EasyGlow glow discharge unit ...
-
bioRxiv - Biochemistry 2023Quote: Quantifoil Cu200 R2/2 grids (Quantifoil) were pre-clipped and marked along the clip edge to determine the orientation in the future ...
-
bioRxiv - Microbiology 2022Quote: ... Quantifoil (R2/2, Quantifoil Micro Tools) Au-EM finder grids ...
-
bioRxiv - Molecular Biology 2022Quote: Purified SARS-CoV-2 spike samples in 10mM Hepes pH7.2 and 150mM NaCl (3 μL at 0.62-0.75mg/ml) were kept at 4C until their application onto QUANTIFOIL R 1.2/1.3 Cu:300-mesh grids (QUANTIFOIL). The grids were vitrified using a Leica GP automatic vitrification robot (Leica) ...
-
bioRxiv - Biochemistry 2022Quote: ... 3 μl of sample was applied to a plasma treated gold coated R 1.2/1.3 300 mesh holey carbon grid (Quantifoil), with a blot force of 0 ...
-
bioRxiv - Molecular Biology 2022Quote: ... 3 μl of protein sample was applied to holey carbon grids (Quantifoil, R 0.6/1 Cu 200 mesh) which were H2/O2 glow-discharged for 30 s ...
-
bioRxiv - Cell Biology 2020Quote: ... 2.5 μl of samples was frozen onto a glow discharged Quantifoil Gold R 1.2/1.3 300 mesh grid (Quantifoil). Samples were frozen under 100% humidity ...
-
bioRxiv - Biochemistry 2021Quote: ... a 5 μl drop was applied to a graphene-treated and glow-discharged holey carbon grid (R 1.2/1.3 Quantifoil) for the BsClpP pH 4.2 sample and negatively glow-discharged holey carbon grid (R 1.2/1.3 Quantifoil ...
-
bioRxiv - Biophysics 2021Quote: ... 3 μl sample was applied to each side of the UltrAuFoil grid (300 mesh, R 1.2/1.3, Quantifoil), which had been glow discharged on both sides (25 mA ...
-
bioRxiv - Immunology 2022Quote: ... 3 μL of the DCFHP proteins were applied onto a glow-discharged Quantifoil R 1.2/1.3 Cu 300-mesh grid (Quantifoil). The grids were blotted for 2 sec at 20°C and 100% humidity and rapidly cryocooled in liquid ethane using a Vitrobot Mark IV instrument (Thermo Fisher Scientific) ...
-
bioRxiv - Molecular Biology 2023Quote: ... 3μL of protein was deposited on holey carbon copper grids (QUANTIFOIL R 1.2/1.3-2nm, 300 mesh, EMS) which had been glow-discharged for 20s at 15 mA using PELCO easiGlow (TedPella Inc) ...
-
bioRxiv - Molecular Biology 2023Quote: ... 4 ul aliquot of the mixture was adsorbed onto a glow-discharged Quantifoil R 1.2/1.3 300 mesh grid (Quantifoil) and vitrified in liquid ethane with a Leica EM GP2 cryoplunger (Leica ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 μl of sample was applied to a plasma treated gold coated R 1.2/1.3 300 mesh holey carbon grid (Quantifoil), with a blot force of 0 ...
-
bioRxiv - Microbiology 2024Quote: ... was applied to previously glow discharged R 1.2/1.3 Molybdenum 200 grids with a holey carbon support film (Quantifoil). Grids were quickly transferred to an EM GP Leica for blotting for 1.5-2.5 seconds at 90% humidity and flash frozen in liquid ethane cooled by liquid nitrogen ...
-
bioRxiv - Biochemistry 2024Quote: ... 3.2 μl samples of the solution were applied onto EM grids (Quantifoil, R 1.2/1.3 Cu 300 mesh) that had been glow discharged with PELCO easiGlow for 60 seconds in Vitrobot Mark IV chamber at 4°C and 90% humidity ...
-
bioRxiv - Biochemistry 2021Quote: ... applied to 300-mesh carbon coated (2nm thickness) holey carbon Quantifoil 2/2 grids (Quantifoil Micro Tools) and flash-frozen as described in (Khatter et al. ...
-
bioRxiv - Biophysics 2023Quote: EM grids (UltrAuFoil R2/2 Au 200 mesh Q250AR2A and Quantifoil R2/2 Au 200 mesh Q2100AR2) were micropatterned using the Alveole PRIMO micropatterning system20–22 ...
-
bioRxiv - Biophysics 2020Quote: Purified GABAAR was incubated with ~1 μM Megabody-2524 and 3.5 μl sample was applied to glow discharged 300 mesh 1.2/1.3 and 2/2 UltraAuFoil gold grids (Quantifoil) for 30 s then blotted for 5.5 s prior to plunge-freezing with liquid ethane cooled by liquid nitrogen ...
-
bioRxiv - Bioengineering 2022Quote: ... Holey carbon Quantifoil grids (2 µm diameter with an interspace of 2 µm, Quantifoil Micro Tools GmbH, Germany) were prepared by glow discharge (easyGlow® System ...
-
bioRxiv - Microbiology 2021Quote: An aliquot (2.5 µL) of the purified tokyovirus particles was placed onto R 1.2/1.3 Quantifoil grids (Quantifoil Micro Tools) that were glow-discharged using a plasma ion bombarder (PIB-10 ...
-
bioRxiv - Neuroscience 2024Quote: ... Double application of 3 μL protein (∼0.6 mg/mL) SYM2081 complex was carried out on glow-discharged gold grids (R 0.6/1, 300 mesh, Quantifoil). The grids were blotted for 4.5 s and 3.5 s ...
-
bioRxiv - Microbiology 2024Quote: ... after applying 2.5 µl of sample to a cryoEM grid (Quantifoil Cu/Rh R3.5/1, UltrAuFoil R 1.2/1.3) as described previously56.
-
bioRxiv - Biophysics 2024Quote: ... The sample was applied in aliquots of 3 µL to Quantifoil R 1.2/1.3 holey carbon (copper) grids (Quantifoil microtools), which were rendered hydrophilic before use by glow-discharge treatment (Pelco easiGlow) ...
-
bioRxiv - Biophysics 2021Quote: Gold EM grids with R1/4 holey SiO2 film (Quantifoil) were glow-discharged in a EasiGlow (Pelco ...
-
bioRxiv - Biophysics 2023Quote: 200 mesh Au grids with R1/4 SiO2 foil (Quantifoil) were glow-discharged for 90 sec at 0.38 mBar and 15 mA using a Pelco easiGlow device ...
-
bioRxiv - Microbiology 2022Quote: ... using R2/2 200 mesh grids (Quantifoil) and imaged using a Talos 120 kV cryo-transmission electron microscope.
-
bioRxiv - Microbiology 2023Quote: R2/2 Cu 200 mesh grids (Quantifoil) were glow-discharged for 40 s at 2.7 mA ...
-
bioRxiv - Biochemistry 2023Quote: UltrAuFoil R2/2 Au200 mesh grids (Quantifoil) were glow discharged for 1 min on both sides at 25 mA using a Pelco easiGlow unit (Ted Pella ...
-
bioRxiv - Biochemistry 2024Quote: UltrAuFoil R2/2 Au300 mesh grids (Quantifoil) were glow discharged for 30 seconds on each side at 25 mA using a Pelco easiGlow unit (Ted Pella ...
-
bioRxiv - Cell Biology 2024Quote: ... or G200F1 R2/2 SiO2 grids (Quantifoil). The grids were glow discharged and coated with human fibronectin (FAL356008 ...
-
bioRxiv - Cell Biology 2022Quote: Cells were trypsinized and seeded onto 200 mesh gold holey carbon grids (R2/2-2 C, Quantifoil Micro Tools) placed in 3D printed grid holders (51 ...
-
bioRxiv - Cell Biology 2023Quote: ... three microliters of EV sample were directly placed onto a glow–discharged 2/2 copper grid (Quantifoil, Jena, Germany). The excess sample was removed with 595 filter paper (Schleicher & Schuell ...
-
bioRxiv - Biochemistry 2024Quote: ... a freshly glow-discharged Cu300 R2/2 holey carbon grid with a 2-nm layer of amorphous carbon (Quantifoil) was mounted in the chamber of a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Microbiology 2021Quote: ... Aliquot (2.5 μL) of the sample was placed onto a holey-carbon copper grid (Quantifoil Micro Tools, R 1.2/1.3) previously glow-discharged in a plasma ion bombarder (PIB-10 ...
-
High-resolution model of Arabidopsis Photosystem II reveals the consequences of digitonin-extractionbioRxiv - Plant Biology 2021Quote: ... 4 μl concentrated sample was applied to glow-discharged (30 s at 50 mA) Quantifoil R 1.2/1.3 Cu 300 grids (Quantifoil Micro Tools) and grids were plunge frozen in liquid ethane using an FEI Vitrobot MkIV (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2024Quote: ... Vitrified specimen was prepared by applying 3 μl of protein complexes onto a glow-discharged 300 mesh gold holey carbon Quantifoil R 1.2/1.3 grid (Quantifoil Micro Tools) and frozen in liquid ethane cooled by liquid nitrogen inside a Vitrobot Mark IV (FEI) ...
-
bioRxiv - Microbiology 2023Quote: ... 2 μL of sample was applied on each side of a freshly glow-discharged QUANTIFOIL R 1.2/1.3 Cu 200-mesh grid (Quantifoil Micro Tools). The grid was blotted at once for 15 s from the back side and plunged into liquid ethane using EM GP2 (Leica Microsystems ...
-
bioRxiv - Neuroscience 2022Quote: ... Gold Quantifoil grids (R1/4, Au 200 mesh, Quantifoil Micro Tools) were additionally coated with a 20-25 nm carbon layer (MED 020 ...
-
bioRxiv - Biophysics 2021Quote: 4 µL of purified HsPepT1 at 2 mg/mL was applied to a glow discharged gold holey carbon 2/1 300-mesh grid (Quantifoil). The grid was blotted for 4 s at 0 force before being plunge vitrified in liquid propane using a Mark IV Vitrobot (ThermoFisher) ...
-
bioRxiv - Molecular Biology 2020Quote: Samples were diluted to a concentration of 60-65 nM for the Pol II-U1 snRNP complex and 2 μl was applied to each side of the R2/2 UltrAuFoil grids (Quantifoil) that had been glow-discharged for 100 s ...
-
bioRxiv - Biophysics 2021Quote: ... 3.5 μL of sample were applied to glow-discharged 2/2 Quantifoil holey carbon grids (Quantifoil Micro Tools GmbH, Germany) and plunged frozen in liquid ethane with a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2022Quote: R2/2 holey carbon supported copper grids (Quantifoil) coated with a 2nm thin carbon layer were treated as described (A ...
-
bioRxiv - Biochemistry 2020Quote: ... QF AU-200 mesh R2/2 grids (Quantifoil) were glow-discharged and placed into a 6-well tissue culture plate well containing 2 mL of cell culture medium for at least 1 h before cell seeding ...
-
bioRxiv - Biochemistry 2023Quote: ... UltrAufoil Au 200 mesh R2/2 grids (Quantifoil) EM grids were glow-discharged on each side for 90 s at 30 sccm ...
-
bioRxiv - Microbiology 2022Quote: ... gold finder grids (Au NH2 R2/2, Quantifoil) containing infected amoebae were vitrified by back-blotting (Teflon ...
-
bioRxiv - Biochemistry 2022Quote: ... with a surface-active additive (0.01% (w/v) glycyrrhizic acid) was added to a glow discharged (PELCO easiGlow) holey gold grid (Quantifoil UltrAuFoil grids (R0.6/1 ...
-
bioRxiv - Microbiology 2021Quote: ... 3μl of protein solution at a concentration of 0.2 mg/ml were deposited on glow-discharged Quantifoil R 1.2/1.3 holey carbon grids (Quantifoil Micro Tools GmbH, Germany). Samples were manually blotted for four seconds at room temperature and vitrified by rapidly plunging into liquid ethane using a home-built plunging apparatus ...
-
bioRxiv - Biochemistry 2021Quote: A 3 μL aliquot of mutant mTORC1 A1459P/DEPTOR complex was added onto UltrAuFoil R 1.2/1.3 Au 300 mesh (Quantifoil Micro Tools GmbH) after the grid was glow-discharged using an Edwards Sputter Coater S150B for 60 s at 40 mA ...