Labshake search
Citations for Quantifoil Micro Tools :
151 - 200 of 607 citations for R 4 5 Isopropylidene 2 pentanoic acid since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2020Quote: ... 3 µl of sample were applied to glow-discharged Quantifoil Au 2/2 holey carbon 200 mesh grids or Ultrafoil Au 2/2 holey gold 200 mesh grids (Quantifoil), and flash frozen in liquid ethane using an FEI Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2020Quote: UltrAUfoil 2/2 300 mesh gold grids (Quantifoil) were used for open hole data collection (Dataset 1) ...
-
bioRxiv - Microbiology 2020Quote: ... A small volume (4 µL) of cells was then transferred onto freshly glow‐discharged copper R2/2 200 Quantifoil holey carbon grids (Quantifoil Micro Tools GmbH, Jena, Germany). Grids were then blotted and plunge‐frozen in a liquid ethane/propane mixture 31 using an FEI Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Immunology 2022Quote: ... and UltrAuFoil R 1.2/1.3 grids (300-mesh; Quantifoil Micro Tools GmbH). The plasma cleaning step was performed in the Solarus 950 plasma system (Gatan ...
-
bioRxiv - Cell Biology 2022Quote: ... Holey Carbon Film R 1.2/1.3 Copper 400 mesh EM grids (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Bioengineering 2022Quote: ... holey carbon grids (Ultrafoil 25 nM Au R 0.6/1 300 mesh; Quantifoil) were incubated with a thiol reactive ...
-
bioRxiv - Biochemistry 2023Quote: ... applied on glow-discharged UltrAuFoil R 1.2/1.3 gold grids (Quantifoil Micro Tools), flash-frozen in liquid ethane using a Vitrobot Mark II device (FEI) ...
-
bioRxiv - Molecular Biology 2023Quote: ... Samples were deposited on an Ultra Au foil R 1.2/1.3 grid (Quantifoil) that was plasma-cleaned for 1.5 min (Gatan Solarus 950) ...
-
bioRxiv - Immunology 2023Quote: ... We used UltrAuFoil R 1.2/1.3 (Au, 300-mesh; Quantifoil Micro Tools GmbH) grids for freezing ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: Quantifoil grids (UltraAuFoil R 0.6/1, Au 300 mesh, Quantifoil MicroTools, Jena, Germany) were treated by plasma cleaning (Harrick Plasma ...
-
bioRxiv - Molecular Biology 2024Quote: ... All-gold grids (UltrAuFoil R 1.2/1.3, 300-mesh, QuantiFoil Micro Tools GmbH) (Russo & Passmore ...
-
bioRxiv - Immunology 2024Quote: ... The sample was prepared on Quantifoil Cu 300 2/2 (Quantifoil) grids and was frozen in liquid ethane using the Vitroblot Mark IV (Thermo Fisher ...
-
bioRxiv - Plant Biology 2024Quote: 4 μL AtEDS1-AtPAD4-AtADR1 complex purified from Nb leaves was applied to glow-discharged Quantifoil holey carbon grids (Quantifoil Cu R1.2/1.3+2 nm C, 300 mesh). The protein was concentrated to 0.9 mg/mL prior to freezing ...
-
bioRxiv - Biophysics 2020Quote: ... Protein was frozen on R 1.2/1.3 grids with 300 Au mesh (Quantifoil, Germany). This dataset was collected at UCSF on the Titan Krios 2 ...
-
bioRxiv - Biochemistry 2024Quote: ... The 300-mesh Quanti-foil R 1.2/1.3 copper EM grids (Quantifoil Micro Tools) were discharged at 15 mA for 60 seconds using a glow-discharger (PELCO) ...
-
bioRxiv - Biochemistry 2022Quote: R2/2 grids (Quantifoil) were covered with a thin layer of continuous carbon (estimated to be 50 Å thick ...
-
bioRxiv - Biochemistry 2022Quote: ... a 3.0 µL drop was applied to glow discharged holey carbon (R 1.2/1.3; Quantifoil), then blotted for 3 s ...
-
bioRxiv - Cell Biology 2022Quote: ... and UV sterilized R ¼ Carbon 200-mesh gold electron microscopy (EM) grids (Quantifoil Micro Tools). After 15-18 hours of culture ...
-
bioRxiv - Biophysics 2022Quote: ... except for using copper grid coated with holey carbon (R 1.2/1.3; Quantifoil, Jena, Germany), applying 4 µl virus sample and not adding fiducial beads ...
-
bioRxiv - Molecular Biology 2023Quote: ... and vitrification of samples on holey carbon R 1.2/1.3 copper 300 mesh grids (Quantifoil) using a Vitrobot MarkIV device (Thermofisher ...
-
bioRxiv - Biophysics 2024Quote: ... 10 second hold) Holey Carbon 300 mesh R 1.2/1.3 gold grid (Quantifoil, Großlöbichau, Germany). After a ∼5 second manual wait time ...
-
bioRxiv - Molecular Biology 2022Quote: ... Glow-discharged carbon coated gold mesh grids (QF 2/2 AU 200, Quantifoil) were placed on the edge of the glass microscopy slides ...
-
bioRxiv - Neuroscience 2020Quote: ... covered with either 2 nm amorphous carbon (Quantifoil, R2/1+2 nm C) or graphene were used for sample preparation ...
-
bioRxiv - Biochemistry 2023Quote: ... the same proteins were applied to holey grids with a 2 nm carbon film (Quantifoil Cu 2/2 200 mesh from EMS). Samples were frozen after a total of 145 min on the grids without carbon film and 150 min on the grids with carbon film ...
-
bioRxiv - Biophysics 2022Quote: ... the extra carbon coated gold Quantifoil grids (200 mesh, R 1.2/20, holey carbon film; Quantifoil Micro Tools GmbH ...
-
bioRxiv - Biophysics 2020Quote: ... A 2.5-μL aliquot was placed on an R 1.2/1.3 Quantifoil grid (Quantifoil Micro Tools) pre-treated by a glow discharge ...
-
bioRxiv - Biochemistry 2022Quote: ... The sample was then applied to a gold Quantifoil R 1.2/1.3 holey carbon grid (Quantifoil) that was glow discharged for 35 sec using PELCO easiGlow glow discharge cleaner ...
-
bioRxiv - Bioengineering 2022Quote: ... applied to a holey carbon grid (Ultrafoil 25 nM Au R 1.2/1,3 300 mesh; Quantifoil) pretreated with SAM solution ...
-
bioRxiv - Molecular Biology 2023Quote: ... to prepare thin vitreous samples on Quantifoil type R 1.2/1.3 holey-carbon grids (Quantifoil Microtools). The grids were made hydrophilic ...
-
bioRxiv - Biochemistry 2024Quote: ... 3 µL of purified protein was applied to an UltrAuFoil® R 1.2/1.3 grid (Quantifoil) that had been glow-discharged for 1 minute and 45 seconds ...
-
bioRxiv - Cell Biology 2021Quote: Gold grids (Quantifoil, R2/2) were glow-discharged and incubated on top of 40 μL droplets of fibronectin (50 μg/mL ...
-
bioRxiv - Biochemistry 2024Quote: ... R2/2 UltrAuFoil grids (Quantifoil) were glow-discharged for 100 s ...
-
bioRxiv - Biochemistry 2024Quote: ... R2/2 UltrAuFoil grids (Quantifoil) were glow-discharged for 100 s ...
-
bioRxiv - Cell Biology 2020Quote: ... or holey SiO2 R1/4 TEM grids (Quantifoil) to allow for more robust correlation and cells were plunge frozen on a Vitrobot Mark IV (FEI ...
-
bioRxiv - Cell Biology 2022Quote: ... Grids (200 Mesh Cu SiO2 R1/4, Quantifoil) were plasma cleaned for 30 s before plunging ...
-
bioRxiv - Neuroscience 2023Quote: ... applied to glow-discharged 2/2 μm holey carbon-coated 200-mesh gold grids (Quantifoil) and plunge-frozen in liquid ethane using a Vitrobot Mark IV (Thermo Fisher) ...
-
bioRxiv - Biophysics 2024Quote: ... We glow-discharge-treated 200 mesh R1/4 or R2/4 Quantifoil holey carbon gold grids (Quantifoil®, Grossloebichau/Jena Germany) in a Pelco easiGlow (Ted Pella ...
-
bioRxiv - Biochemistry 2021Quote: 2.5 μl of ACE2-RBD-62 complex at 3.5 mg/ml concentration was transferred to glow discharged UltrAuFoil R 1.2/1.3 300 mesh grids (Quantifoil), blotted for 2.5 seconds at 4°C ...
-
bioRxiv - Biophysics 2021Quote: ... 1.5 μl of THO*•Sub2 was applied to a glow-discharged UltrAuFoil R 1.2/1.3 grids (Quantifoil). Grids were blotted for 3 s with a blotting force of 3 and 100% humidity at 22 °C and plunged into liquid ethane using an FEI Vitrobot Mark IV (Thermo Fisher).
-
bioRxiv - Microbiology 2021Quote: ... 3μL of protein was deposited on a holey copper grids (QUANTIFOIL R 1.2/1.3, 200 mesh, EMS) which had been glow-discharged for 30s at 15 mA (Tedpella Inc) ...
-
bioRxiv - Immunology 2021Quote: ... Two types of grids were used: UltrAuFoil R 1.2/1.3 (Au, 300-mesh; Quantifoil Micro Tools GmbH) and Quantifoil R 2/1 (Cu ...
-
bioRxiv - Biophysics 2020Quote: 3 ml of apoferritin at 3.8 mg/ml were applied to freshly glow discharged R 1.2/1.3 holey carbon grids (Quantifoil) at 4°C and 100% relative humidity followed by plunge-freezing in liquid ethane using a Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Biochemistry 2022Quote: ... proper dilutions were made to a final concentration of ∼.7 mg/mL and a 3.0 µL drop was applied to glow discharged holey carbon (R 1.2/1.3; Quantifoil), then blotted for 3 s ...
-
bioRxiv - Biochemistry 2021Quote: ... for the BsClpP pH 4.2 sample and negatively glow-discharged holey carbon grid (R 1.2/1.3 Quantifoil) for the BsClpP pH 6.5 sample ...
-
bioRxiv - Molecular Biology 2023Quote: ... applied to a glow-discharged R 1.2/1.3 300 mesh UltrAuFoil gold grid (Quantifoil Micro Tools GmbH) and plunge-frozen in liquid ethane using a Vitrobot Mark IV (Thermo Scientific ...
-
bioRxiv - Biophysics 2023Quote: 3 μl purified MRS2 at approximately 0.5 mg/ml was applied to a glow-discharged 400-mesh R 1.2/1.3 Cu grid (Quantifoil). The cryo grids were blotted for 6 s at 4°C and 95% ...
-
bioRxiv - Biochemistry 2023Quote: ... An aliquot of the incubated mixture (3.5 μl) was applied onto glow-discharged UltrAuFoil 300 mesh R 1.2/1.3 grids (Quantifoil) at ∼4 °C ...
-
bioRxiv - Bioengineering 2023Quote: ... These samples were applied onto UltrAuFoil R 1.2/1.3 grids (Au, 300-mesh; Quantifoil Micro Tools GmbH). Prior to sample application the grids were glow-discharged using Ar/O2 plasma for 10 s on a Solarus 950 plasma cleaner (Gatan) ...
-
bioRxiv - Cell Biology 2024Quote: ... and then 4 μL of the sample was applied to the glow-discharged R1/4 Carbon 200-mesh gold EM grid (Quantifoil Micro Tools). The EM grid was incubated in the chamber of Vitrobot (Vitrobot Mark 4 ...
-
bioRxiv - Biophysics 2022Quote: ... R2/2 Cu 300 grids (Quantifoil) were glow-discharged for 1 min at 0.19 mbar and 20 mA in a PELCO easiGlow device ...