Labshake search
Citations for Quantifoil Micro Tools :
101 - 150 of 607 citations for R 4 5 Isopropylidene 2 pentanoic acid since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2022Quote: ... or AE1-Niflumic acid at 5 mg/ml were applied to glow-discharged holey carbon EM grids (Quantifoil 300 copper mesh, R1.2/1.3) in an EM-GP2 plunge freezer (Leica) ...
-
bioRxiv - Microbiology 2020Quote: ... 3.5 μl of cell suspension from 80-100 μl of final volume were applied on glow discharged 200-mesh EM copper grids coated with R 2/1 holey SiO2 films (Quantifoil Micro Tool GmbH) and plunge frozen in liquid ethane at ~−184°C using a Leica EM GP grid plunger ...
-
bioRxiv - Biophysics 2020Quote: ... 3.5ul of cell suspension were applied on 200-mesh copper grids coated with R 2/1 holey carbon or SiO2 films (Quantifoil Micro Tools GmbH) and plunge frozen in liquid ethane at ~-186°C using a Leica EM GP grid plunger ...
-
bioRxiv - Immunology 2022Quote: ... detergent at a final concentration of 0.005 mM was added to each sample and 3 µl of that solution was immediately loaded onto plasma-cleaned QuantiFoil R 2/1 (400-mesh; Quantifoil Micro Tools GmbH) and UltrAuFoil R 1.2/1.3 grids (300-mesh ...
-
bioRxiv - Immunology 2020Quote: ... and 3 µl was immediately loaded onto plasma cleaned Quantifoil R 2/1 holey carbon copper gri (Cu, 400-mesh, Quantifoil Micro Tools GmbH). Blotted grids were plunge-frozen into nitrogen-cooled liquid ethane.
-
bioRxiv - Biophysics 2022Quote: ... an aliquot of 3 μL of sample was applied onto a glow-discharged holey carbon-coated copper grid (300 mesh, QUANTIFOIL® R 2/1) or holey gold grid (300 mesh ...
-
bioRxiv - Microbiology 2024Quote: ... 4 µl of the concentrated cells were then spotted onto a glow discharged copper grid (R2/2, Quantifoil). By using a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Immunology 2022Quote: ... grids (Quantifoil R 1.2/1.3 300 mesh) were first glow discharged for 60 seconds at 15 mA with a Pelco easiGlow glow discharge unit and 4 μL LNP suspension was applied to the surface of the grid ...
-
bioRxiv - Immunology 2023Quote: ... respectively) and 3 μl were kept 5 min at RT until their application onto glow-discharged holey carbon grids (Quantifoil, Au 300 mesh, R 0.6/1). The grids were blotted and then plunged into liquid ethane using a FEI Vitrobot Mark IV at 20°C and 95% relative humidity ...
-
bioRxiv - Biophysics 2021Quote: ... 4 µl of this mixture was applied on a glow-discharged Quantifoil R2/2 grid (Quantifoil Micro Tools GmbH) and flash-frozen in liquid ethane using a Vitrobot Mark II device (FEI) ...
-
bioRxiv - Microbiology 2024Quote: ... 4 μL of the cell mixture was applied three times onto glow-discharged copper EM grids (R2/2, Quantifoil), followed by plunge freezing into liquid ethane/propane ...
-
bioRxiv - Biophysics 2024Quote: ... 4 µL of resuspended solution was applied to freshly glow-discharged Quantifoil R2/2 mesh 300 gold grids (Quantifoil) in a Vitrobot IV (ThermoFisher ...
-
bioRxiv - Microbiology 2022Quote: ... the amoebae (5×105 per well) were seeded onto EM gold finder grids (Au NH2 R2/2, Quantifoil) and incubated for 1 h ...
-
bioRxiv - Neuroscience 2021Quote: ... 300 mesh R 1.2/1.3 gold grids (Quantifoil). Samples were plunge frozen in liquid nitrogen cooled liquid ethane using a FEI Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Molecular Biology 2023Quote: ... UltrAuFoil R 1.2/1.3 300 Au mesh (Quantifoil) grids were glow discharged with residual air for 30 seconds ...
-
bioRxiv - Molecular Biology 2022Quote: ... UltrAuFoil R 1.2/1.3 300 Au mesh (Quantifoil) grids were glow discharged with residual air for 30 seconds ...
-
bioRxiv - Cell Biology 2020Quote: ... 3 μl of samples were applied to glow-discharged Quantifoil R 0.6/1 and R 1.2/1.3 grids (Quantifoil Micro tools GmbH, Germany), blotted for 3 s and then flash frozen in liquid ethane using the automatic plunge freezer EM GP2 at 100% relative humidity ...
-
bioRxiv - Biochemistry 2023Quote: The grids (Quantifoil R 1.2/1.3 Cu 300 mesh) were glow discharged at 10 mA for 60s (EM ACE200 ...
-
bioRxiv - Biochemistry 2024Quote: ... 300 mesh 100 R 1.2/1.3 UltraAuFoil grids (Quantifoil) with 2 nm carbon were glow discharged in a PELCO easiGlow for 12 seconds at 25 mAmp and 0.37 mBar before 4 μL of sample were added to each grid ...
-
bioRxiv - Molecular Biology 2020Quote: ... plain grids (Quantifoil 2/2) were transferred to the microscope ...
-
bioRxiv - Biophysics 2022Quote: ... for 25 s) grid (For GDN 150mM: UltrAuFoil 300 mesh R 1.2/1.3, other samples: gold holey carbon Quantifoil 300 mesh R 1.2/1.3). After a ∼5 s manual wait time ...
-
Genome modularization reveals overlapped gene topology is necessary for efficient viral reproductionbioRxiv - Synthetic Biology 2020Quote: A 4 μL solution of co-isolated small particles were applied to glow-discharged copper grids (Quantifoil R2/2, Quantifoil Micro Tools), blotting for 3-seconds at 4 °C with 90% humidity and plunging into liquid ethane using a Lecia EM GP device (Leica Microsystems ...
-
Genome modularization reveals overlapped gene topology is necessary for efficient viral reproductionbioRxiv - Synthetic Biology 2020Quote: A 4 μL solution of co-isolated small particles were applied to glow-discharged copper grids (Quantifoil R2/2, Quantifoil Micro Tools), blotting for 3-seconds at 4 °C with 90% humidity and plunging into liquid ethane using a Lecia EM GP device (Leica Microsystems ...
-
Mycobacteria form viable cell wall-deficient cells that are undetectable by conventional diagnosticsbioRxiv - Microbiology 2022Quote: ... of which 3-4 µL was applied on glow-discharged 200 mesh copper grids with an extra thick R2/2 carbon film (Quantifoil Micro Tools). Vitrification was performed using an automated Leica EM GP plunge-freezer ...
-
bioRxiv - Biochemistry 2024Quote: Grids for cryo-EM were prepared by applying 4 µL of sample on a glow-discharged Quantifoil 300 mesh Cu 2/1 grid (Quantifoil Micro Tools), blotting for 7.5 seconds ...
-
bioRxiv - Biophysics 2021Quote: Holey carbon grids (Quantifoil Au 300 mesh, R 0.6/1) coated with home-made ultrathin continuous carbon were glow-discharged by plasma cleaner (Harrick ...
-
bioRxiv - Biophysics 2020Quote: Holey carbon grids (Quantifoil Au 300 mesh, R 0.6/1) were glow-discharged by Solarus advanced plasma system (Gatan ...
-
bioRxiv - Biophysics 2022Quote: ... 300 mesh R 1.2/1.3 gold grids (Quantifoil, Großlöbichau, Germany) and plunge frozen in liquid ethane using a FEI Vitrobot Mark IV (ThermoFisher Scientific ...
-
bioRxiv - Biophysics 2021Quote: UltrAuFoil holey gold grids (Quantifoil R 0.6/1.0, Au 300) were plasma cleaned for thirty seconds with H2 and O2 (Gatan) ...
-
bioRxiv - Physiology 2021Quote: ... 300 mesh R 1.2/1.3 gold grids (Quantifoil, Großlöbichau, Germany). A Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2020Quote: ... 300 mesh R 1.2/1.3 gold grids (Quantifoil, Großlöbichau, Germany). A FEI Vitrobot Mark IV (ThermoFisher Scientific ...
-
bioRxiv - Biophysics 2021Quote: ... 300 mesh R 1.2/1.3 gold grids (Quantifoil, Großlöbichau, Germany). A FEI Vitrobot Mark IV (ThermoFisher Scientific ...
-
bioRxiv - Biochemistry 2021Quote: For cryo-EM UltrAuFoil R 2.0/2.0 grids (Quantifoil, Germany) were negatively glow discharged using a PELCO Easiglow and coated with graphene oxide as described in Cheng et al. ...
-
bioRxiv - Microbiology 2024Quote: ... 300 mesh R 1.2/1.3 gold grids (Quantifoil, Großlöbichau, Germany) (M:scFab ...
-
bioRxiv - Biophysics 2024Quote: ... Holey carbon grids (Quantifoil Au 300 mesh, R 0.6/1) were coated with freshly prepared graphene oxide ...
-
bioRxiv - Biochemistry 2024Quote: ... Holey carbon grids (Quantifoil Au 300 mesh, R 0.6/1) were glow-discharged by Solarus advanced plasma system (Gatan) ...
-
bioRxiv - Synthetic Biology 2021Quote: ... 25 mM Tris at pH 8.0 to a concentration of 2 mg/mL to a glow-discharged (1 min at 5 mA) holey carbon grid (Quantifoil Q225-CR1.3). This was followed by plunge-freezing in liquid ethane using an FEI Vitribot Mark IV (100% humidity ...
-
bioRxiv - Cell Biology 2020Quote: ... Cells were incubated at 37°C and 5% CO2 for 16h prior to trypsinization and seeding onto 200 mesh gold holey carbon grids (R2/2-2C; Quantifoil Micro Tools), which were placed in 3D printed grid holders [39] ...
-
bioRxiv - Cell Biology 2024Quote: ... An aliquot of a 5 μl sample was applied to a glow-discharged holey carbon grid (Quantifoil R2/2, Au, 400 mesh). After waiting for 60 s ...
-
bioRxiv - Biochemistry 2020Quote: ... holey carbon grids (Quantifoil R 1.2/1.3, Micro Tools GmbH, Germany). The grids were blotted for 4 seconds and vitrified by rapidly plunging into liquid ethane at −182 °C using Leica EM GP plunger (Leica Microsystems ...
-
bioRxiv - Biochemistry 2022Quote: ... holey carbon grids (Quantifoil R 1.2/1.3, Micro Tools GmbH, Germany). The grids were blotted for 4 seconds and vitrified by rapidly plunging into liquid ethane at −182 °C using Leica EM GP plunger (Leica Microsystems ...
-
bioRxiv - Biochemistry 2023Quote: ... Quantifoil R 1.2/1.3 200 mesh Copper TEM grids (Quantifoil Microtools) and blotted for 3 sec using a Mark IV Vitrobot (FEI ...
-
Functional and epitope specific monoclonal antibody discovery directly from immune sera using cryoEMbioRxiv - Immunology 2024Quote: UltrAuFoil R 1.2/1.3 grids (Au, 300 mesh; Quantifoil Micro ToolsGmbH) were used for sample vitrification ...
-
bioRxiv - Biochemistry 2024Quote: UltrAuFoil 300 mesh (Quantifoil Micro Tools GMBH; R 1.2/1.3 geometry) grids were glow-discharged at 25 mA for 30 s using an EMS100X glow-discharge unit ...
-
bioRxiv - Biophysics 2024Quote: ... carbon-coated grid (Quantifoil R 1.2/1.3, Cu/Rh, 300 mesh) supplemented apyrase (5 U/ml) ...
-
bioRxiv - Molecular Biology 2021Quote: ... 4 μl of protein sample (about 0.73 mg/ml) was applied onto a glow-discharged holey carbon grid (Quantifoil Au, R2/2, 300 mesh). After blotting for 3 s ...
-
bioRxiv - Biophysics 2021Quote: To provide extra support for cell growth 5-6 nm of carbon was evaporated onto Quantifoil Au 200 R2/1 or R2/2 grids (Quantifoil Micro Tools GmbH). Grids were then glow discharged and incubated in supplemented RPMI-1640 overnight in the cell incubator ...
-
bioRxiv - Biophysics 2022Quote: Purified wt or mutant D263A or F55A MVMp capsid samples (5 μl) were applied onto R2/2 300 mesh copper grids (Quantifoil Micro Tools, Germany) and vitrified using a Leica EM CPC cryofixation unit ...
-
bioRxiv - Cell Biology 2024Quote: ... An aliquot of 3.5 μl of the crude membrane sample was deposited onto freshly glow-discharged Quantifoil R2/2 200-mesh grids (Quantifoil Micro Tools GmbH,) using the Leica EM GP (Leica Microsystems ...
-
bioRxiv - Cell Biology 2024Quote: ... An aliquot of 3.5 μl of sample was applied to freshly glow-discharged copper Quantifoil R2/2 200-mesh London Finder grids (Quantifoil Micro Tools GmbH) and then plunge frozen using a Leica EM GP plunger (Leica Microsystems ...