Labshake search
Citations for GE Life Sciences :
7701 - 7750 of 10000+ citations since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Plant Biology 2022Quote: ... The concentrated sample was then loaded onto a Superdex 75 16/60 column (GE Healthcare) pre-equilibrated in 100 mM Tris (pH 8.0 ...
-
bioRxiv - Plant Biology 2022Quote: ... The dialysate was then applied to a HiTrap Q HP column (GE Healthcare) in buffer containing 50 mM Tris (pH 7.5) ...
-
bioRxiv - Immunology 2022Quote: ... using the HiLoad 16/600 Superdex 200 pg column (GE Healthcare) running in TBS buffer ...
-
bioRxiv - Plant Biology 2022Quote: ... The sample was finally subjected to hydrophobic interaction chromatography using a phenyl Sepharose column (GE Healthcare) equilibrated in buffer A (50 mM Tris pH 7.5 ...
-
bioRxiv - Plant Biology 2022Quote: ... and 0.005% GDN by using PD-10 columns (GE Healthcare Life Sciences), and air bubbles were removed by centrifugation for 5 min at 10,000 g prior to ITC ...
-
bioRxiv - Microbiology 2022Quote: ... Plates were scanned on the Amersham Typhoon Biomolecular Imager (GE Healthcare, USA). Data were analyzed using ImageQuantTL 8.2 image analysis software (GE Healthcare) ...
-
bioRxiv - Microbiology 2022Quote: ... Data were analyzed using ImageQuantTL 8.2 image analysis software (GE Healthcare). The PRNT titer was calculated using Graphpad Prism 9 ...
-
bioRxiv - Microbiology 2022Quote: ... and incubated with anti-mouse IgG secondary antibodies with HRP (#NA9340, GE Healthcare) (1:4000 ...
-
bioRxiv - Immunology 2022Quote: Peripheral blood mononuclear cells (PBMCs) from COVID-19 patients were isolated from the blood using Ficoll (GE Healthcare) density gradient media and transferred into 96 well plates at a concentration of 2.5 × 106 viable cells per ml in 200µl (0.5 × 106 cells per well ...
-
bioRxiv - Immunology 2022Quote: Percoll (17-0891-02) was purchased from GE Healthcare Life Sciences ...
-
bioRxiv - Immunology 2022Quote: ... the sample was again loaded onto a HisTrap™ HP 5 ml column (GE Healthcare, Diegem, Belgium). The flow-through was collected and concentrated before injection onto a HiLoad® 16/600 Superdex® 75 pg column (GE Healthcare Diegem ...
-
bioRxiv - Immunology 2022Quote: ... and loaded onto a HisTrap™ HP 5 ml column (GE Healthcare, Diegem, Belgium) equilibrated with HBS ...
-
bioRxiv - Immunology 2022Quote: ... The flow-through was collected and concentrated before injection onto a HiLoad® 16/600 Superdex® 75 pg column (GE Healthcare Diegem, Belgium) using HBS as running buffer ...
-
bioRxiv - Immunology 2022Quote: Purified protein samples at a concentration of 0.5 mg ml-1 were injected onto a Superdex Increase 10/300 GL column (GE Healthcare, Diegem, Belgium) that was pre-equilibrated with HBS ...
-
bioRxiv - Immunology 2022Quote: ... The flow-through of the HisTrap™ HP 5 ml column (GE Healthcare, Diegem, Belgium) containing the cleaved protein was collected ...
-
bioRxiv - Immunology 2022Quote: ... The protein was eluted with 250 mM imidazole in HBS after which the imidazole was removed using a HiPrep™ 26/10 Desalting column (GE Healthcare, Diegem, Belgium). The Avi-His6-tag was cleaved by caspase-3 (produced in-house ...
-
bioRxiv - Immunology 2022Quote: ... and by size-exclusion chromatography using Superdex 200 (RBD and NTD) or Superose 6 (S-2P and ferritin) column (GE Healthcare) in 10 mM Tris pH=8 ...
-
bioRxiv - Immunology 2022Quote: ... Samples were spotted onto Amersham Protran nitrocellulose membrane (GE Healthcare), followed by three washing steps for 5 min each with PBS ...
-
bioRxiv - Immunology 2022Quote: ... Proteins were affinity purified using an MBPTrap HP (GE Healthcare) affinity column and eluted in buffer A supplemented with 10 mM maltose.
-
bioRxiv - Immunology 2022Quote: ... followed by Ni-NTA purification and desalting by PD MiniTrap G-25 columns (GE Healthcare Life Sciences).
-
bioRxiv - Immunology 2022Quote: ... The medium of samples collected from the Histrap columns was substituted with PBS solution and then further purified with the Superdex 200 column (GE Healthcare). Lastly ...
-
bioRxiv - Microbiology 2022Quote: ... HisTRAPTM TALON column (5 mL, GE healthcare) was connected to an AKTA prime chromatography system (GE healthcare ...
-
bioRxiv - Immunology 2022Quote: Granulocyte layers were isolated from peripheral blood after density gradient centrifugation (Ficoll-Paque PLUS, GE Healthcare, Uppsala, Sweden) and used for eosinophil purifications by negative selection on an AutoMACS Pro separator using the Eosinophil Purification Kit (Cat ...
-
bioRxiv - Microbiology 2022Quote: ... Proteins were loaded on a HiTrap Heparin HP column (1 mL, GE healthcare) equilibrated with buffer C ...
-
bioRxiv - Microbiology 2022Quote: ... the buffer exchanged protein was concentrated and injected on a SD200 10/300 increase column (GE Healthcare) equilibrated with 25 mM HEPES pH 7.5 ...
-
bioRxiv - Microbiology 2022Quote: ... and was further purified using a SD200 10/300 increase column (GE Healthcare) equilibrated with 50 mM MES ...
-
bioRxiv - Microbiology 2022Quote: ... The top fractions after IMAC were pooled and desalted using a 5 ml HiTrap Desalting column (GE Healthcare) equilibrated with 25 mM HEPES pH 7.5 ...
-
bioRxiv - Microbiology 2022Quote: ... or His-NTV-AviTag (80 µl at 2 mg/ml) were injected on a Superdex 200 increase 10/300 GL column (GE Healthcare), equilibrated at 4°C with a buffer containing 25 mM HEPES pH 7.5 ...
-
bioRxiv - Microbiology 2022Quote: ... The eluted FrdA fraction was subsequently concentrated and injected onto a SD200 10/300 increase column (GE Healthcare) equilibrated with 20 mM HEPES pH 7.5 ...
-
bioRxiv - Microbiology 2022Quote: ... The supernatant was filtered using a 0.2 μl filter and flown over a 5 ml NiNTA IMAC column (GE Healthcare) equilibrated with buffer A (50 mM KH2PO4 pH 7 ...
-
bioRxiv - Microbiology 2022Quote: ... The supernatant was filtered using a 0.2 μl filter and flown over a 5 ml StrepTactin-Sepharose column (GE Healthcare) equilibrated with buffer A (50 mM MES-NaOH ...
-
bioRxiv - Microbiology 2022Quote: ... and the supernatant was filtered using a 0.2 μl filter and flown over a 5 ml NiNTA Immobilised Metal Affinity Chromatography (IMAC) column (GE Healthcare) equilibrated with buffer A (25 mM HEPES pH 7.5 ...
-
bioRxiv - Microbiology 2022Quote: ... and captured with ImageMaster2D Platinum 6.0 (GE Healthcare, USA). Meanwhile ...
-
bioRxiv - Genomics 2022Quote: ... and size exchange chromatography (Superdex 75, GE Healthcare Life Sciences). Protein concentrations were determined by UV-Vis spectroscopy.
-
bioRxiv - Plant Biology 2022Quote: ... and pGEX-4T-1 (GE healthcare) vectors for prokaryotic expression in E ...
-
bioRxiv - Plant Biology 2022Quote: ... The coding sequences for the N-terminal (63-139 aa) and C-terminal (221-307 aa) domain of OR were cloned to the pGEX-4T-1 vector (GE healthcare) for prokaryotic expression ...
-
bioRxiv - Immunology 2022Quote: ... or Protein G Sepharose 4 Fast Flow beads (GE Healthcare, Uppsala, Sweden) in a 96-well filter plate (Millipore Multiscreen ...
-
bioRxiv - Plant Biology 2022Quote: ... 1 μg of total RNA was quantified using a nanodrop spectrophotometer Nanovue (GE Healthcare) and used for making cDNA using Verso cDNA synthesis kit (Thermo Fischer Scientific) ...
-
bioRxiv - Plant Biology 2022Quote: ... and chemiluminescent signals were recorded using ImageQuant RT ECL Imager (GE Healthcare).
-
bioRxiv - Plant Biology 2022Quote: ... The PCR product was cloned downstream and in frame with the glutathione S-transferase (GST) ORF in pGEX-3X (GE Healthcare). The expression construct was transfected into E ...
-
bioRxiv - Genomics 2022Quote: ... Duplex DNA was purified by ion exchange chromatography on a source 15Q column (GE Healthcare Life Sciences) and analyzed by 1% agarose gel ...
-
bioRxiv - Genomics 2022Quote: ... and products resolved by size exclusion chromatography (Superdex 75 10/300; GE Healthcare Life Sciences). Peptide identity was validated by mass spectrometry with positive electrospray ionization (on a Waters Q-Tof Premier) ...
-
bioRxiv - Genomics 2022Quote: ... Octamers were purified via size chromatography over a Sephacryl S-200 column (GE Healthcare Life Sciences).
-
bioRxiv - Genomics 2022Quote: ... and further purified over a source 15Q column (GE Healthcare Life Sciences).
-
bioRxiv - Genomics 2022Quote: ... All BPTF proteins were then further purified using anion exchange (Source 15Q, GE Healthcare Life Sciences) and size exchange chromatography (Superdex 75 ...
-
bioRxiv - Plant Biology 2022Quote: ... Hybridization signals were recorded in an imaging plate (BAS-MP, FujiFilm) and quantified using an image analyzer (Amersham Typhoon, GE Healthcare).
-
bioRxiv - Synthetic Biology 2022Quote: Protein cargo exchange experiments were performed by incubating 100 nM DNA origami with 300nM Alexa-647 labelled protein cargo for 1h before addition to washed s300 resin (according to manufacturer’s instructions, GE Life Sciences) in a spin column and centrifugation for 4 mins at 1000 g to remove free protein ...
-
bioRxiv - Synthetic Biology 2022Quote: Experiments were performed on a Biacore S200 instrument (GE Healthcare Life Sciences). All experiments were performed at room temperature using DNA imaging buffer and a flow rate of 10 µl/min.
-
bioRxiv - Synthetic Biology 2022Quote: ... Supernatant was applied to a 5 ml HisTrap HP column (GE Healthcare) using an AKTA Prime liquid chromatography system before washing with buffer B (20 mM Tris-HCl (pH 8.0) ...
-
bioRxiv - Synthetic Biology 2022Quote: CM3 sensor chips were coupled with streptavidin to near saturation (typically between 4000 and 7000 RU) using the amine coupling kit (GE Healthcare Life Sciences). After streptavidin was coupled ...