bioRxiv - Molecular Biology 2022Quote: Quantifoil 200 mesh holey carbon R2/2 gold grids (Quantifoil Micro Tools) were glow discharged (PELCO easiGlow ...
-
bioRxiv - Microbiology 2022Quote: R2/2 carbon-coated 200 mesh copper Quantifoil grids (Quantifoil Micro Tools) were first glow-discharged for 60 seconds ...
-
bioRxiv - Biophysics 2024Quote: ... R1.2/1.3 or R2/2 UltrAuFoil® grids (Quantifoil Micro Tools GmbH) were glow-discharged with 40 mA for 5 min inside a Quorum GloQube® Plus unit ...
-
bioRxiv - Molecular Biology 2024Quote: ... Quantifoil R2/2 gold 200 mesh grid (Quantifoil Micro Tools GmbH, Germany) glow-discharged for 30 sec in a PIB-10 Ion Bombarder (Vacuum Device Inc ...
-
bioRxiv - Biochemistry 2024Quote: Standard holey carbon electron microscopy grids (Quantifoil, Cu 200 mesh, R2/2) were glow discharged for 30 s at 15 mA on the negative setting ...
-
bioRxiv - Biochemistry 2020Quote: ... 4 µL of sample was applied to Quantifoil Cu R 1.2/1.3 grids (Quantifoil Microtools GmbH) which has undergone a plasma discharge and were vitrified in liquid ethane using a Vitrobot MkIV plunge freezer (Thermo Fisher Scientific) ...
-
bioRxiv - Biophysics 2021Quote: ... Aliquots of 4 µl were applied to glow-discharged 300 mesh R1.2/1.3 Au grids (Quantifoil) using a Vitrobot Mark VI (Thermo Fisher Scientific ...
-
bioRxiv - Biophysics 2023Quote: ... 4 μL of Kapβ2•HNRNPH2 was applied to a 300 mesh copper grid (Quantifoil R1.2/1.3) that was glow-discharged using a PELCO easiGlow glow discharge apparatus at 30 mA/30 s on top of a metal grid holder (Ted Pella) ...
-
bioRxiv - Cell Biology 2024Quote: ... Each glow-discharged Quantifoil R2/4 200 mesh copper grid (Quantifoil Micro Tools GmbH, Jena, Germany) was then deposited with 4 µL sample and plunge-frozen in liquid ethane using a Vitrobot Mark IV (TFS ...
-
bioRxiv - Molecular Biology 2024Quote: ... 4 µl of sample was applied onto 300 mesh R1.2/1.3 UltraAuFoil Holey Gold grids (Quantifoil), which were plasma cleaned for 15 seconds using a Pelco glow discharge cleaning system (TED PELLA ...
-
bioRxiv - Biochemistry 2022Quote: ... An aliquot of 3.5 μl of sample was placed on the glow-discharged cryo-EM grid (Quantifoil R1.2/1.3 or Quantifoil R2/1), blotted and plunge-frozen in liquid ethane using a Mark VI Vitrobot instrument maintained at 100% humidity with blot force 20 and blot time of 3 seconds ...
-
bioRxiv - Cell Biology 2021Quote: MEFs expressing emerald-Vimentin are cultured on glow-discharged holey carbon coated EM grids (Au R2/1, 200 mesh, Quantifoil) for 16 h at 37°C in a humidified CO2 incubator ...
-
bioRxiv - Biochemistry 2022Quote: 3 µl of prepared complexes at a concentration of approximately 1 mg/ml was applied to a glow-discharged Quantifoil 300 mesh copper R1.2/1.3 grids (Quantifoil Micro Tools). The grids were then flash frozen in liquid ethane using a Thermo Fisher Scientific Vitrobot IV (0-0.5 s waiting time ...
-
bioRxiv - Biochemistry 2021Quote: ... Samples of ΦKZ nvRNAP were adsorbed to a thin film of graphene oxide deposited upon the surface of holey carbon copper grids (R2/1, 300 mesh, Quantifoil). Grids were blotted for 1-2 seconds before plunge freezing in liquid ethane using a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2021Quote: An aliquot of 2.5 microliters of purified drCALHM1 sample was applied onto a glow discharged holey carbon film grid (200 mesh, R2/1, Quantifoil). The grid was blotted and flash-frozen in liquid ethane with FEI Vitrobot Mark IV ...
-
bioRxiv - Cell Biology 2020Quote: ... Isolated centrioles were then deposited onto 200-mesh copper EM grids coated with holey carbon (R3.5/1, Quantifoil Micro Tools) and plunge-frozen in a liquid ethane/propane mixture ...
-
bioRxiv - Cell Biology 2021Quote: K5/K14_1 cells were seeded on glow-discharged Collagen I coated holey carbon gold EM grids (Au R2/1, 200 mesh, Quantifoil) and incubated overnight at 32 °C and in 5% CO2 ...
-
bioRxiv - Cell Biology 2020Quote: Samples of concentrated TSCCFL were adsorbed to a thin film of graphene oxide deposited upon the surface of holey carbon copper grids (R2/1, 300 mesh, Quantifoil). Grids were blotted for 2-3 seconds before plunge freezing in liquid ethane using a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2022Quote: ... Three μL of sample at 5 μM was adsorbed onto glow-discharged copper Quantifoil R2/1 holey carbon grids (Quantifoil). Grids were glow discharged 45 seconds at 25 mA using an EMITECH K950 apparatus ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 μl of protein at a concentration of approximately 10 mg ml−1 were loaded onto glow-discharged holey carbon grids (Quantifoil Au 300 mesh R1.2/1.3 or Quantifoil Cu/Rh 300 mesh R1.2/1.3) ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 µl of the VIF-ΔT solution was applied onto glow-discharged holey carbon EM grids (Cu R2/1, 200 mesh, Quantifoil), which were subsequently blotted manually and plunge frozen in liquid ethane.
-
bioRxiv - Biochemistry 2023Quote: ... 2.8 µl of F-actin sample was applied to a glow-discharged R2/1 Cu 300 mesh holey-carbon grid (Quantifoil). Excess solution was blotted away and the grids were plunge frozen in liquid ethane or a liquid ethane/propane mixture using a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Cell Biology 2023Quote: 3 µl of prepared complexes at a concentration of approximately 1 mg/mL was applied to UltrAuFoil 300 mesh gold R1.2/1.3 grids (Quantifoil Micro Tools), freshly glow discharged with an Edwards S150B glow discharger for 1 min 15 sec ...
-
bioRxiv - Plant Biology 2024Quote: ... 4 µL of chloroplasts solution was placed onto R2/1 or R1.2/1.3 carbon-coated 200-mesh copper EM grids (Quantifoil Micro Tools), blotted for 7-8 seconds from the back side (front side pad covered with a Teflon sheet ...
-
bioRxiv - Biophysics 2024Quote: ... 3 µL of purified AE1 at 5 mg/mL was added to a glow discharged (PELCO easiGlow) 0.6/1 µm holey gold grid (Quantifoil UltrAuFoil) and blotted for 4-6 s at 4°C and 100% humidity using the Vitrobot Mark IV system (Thermofisher Scientific) ...
-
bioRxiv - Cell Biology 2024Quote: ... gold EM grids with Quantifoil holey carbon film (Quantifoil, R2/1, 300 mesh, gold; Electron Microscopy Sciences, Q3100AR1; or Quantifoil, R3.5/1 ...
-
bioRxiv - Microbiology 2021Quote: ... loaded onto a R2/2 200 mesh Cu grid (Quantifoil Micro Tools, GmbH), and plunge frozen in liquid ethane using the automated Leica EM GP plunge freezer (Leica Microsystems GmbH) ...
-
bioRxiv - Cell Biology 2020Quote: 200 mesh holey silicon dioxide (SiO2) titanium grids (R2/2; Quantifoil Micro Tools) were glow discharged in an ELMO glow discharge unit (Cordouan Technologies ...
-
bioRxiv - Microbiology 2024Quote: Glow-discharged gold EM grids (200 mesh, Au, holey SiO, R1/2, Quantifoil) were placed into polydimethylsiloxane Sylgard 184 (Farnell GmbH ...
-
bioRxiv - Microbiology 2024Quote: Ultrafoil Au R2/2 200 mesh grids (200 mesh, Quantifoil Micro Tools GmbH) were glow discharged ...
-
bioRxiv - Biophysics 2020Quote: ... 0.2 mM ATP) and 4 μl were applied to glow-discharged 1.2/1.3 holey gold grids (Quantifoil) before plunge freezing in liquid ethane using a Vitrobot (FEI/Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2021Quote: 4 µl of 20-100 nM RZZSF filaments were deposited on freshly glow-discharged Formvar/Carbon (Quantifoil) film supported copper grid Cu400 (Sigma Aldrich ...
-
bioRxiv - Molecular Biology 2020Quote: ... 4 μl of the sample were applied onto 300 mesh R1.2/1.3 UltrAuFoil Holey Gold Films (Quantifoil) that were plasma cleaned prior to sample application for 7 seconds using a Solarus plasma cleaner (Gatan ...
-
bioRxiv - Biophysics 2022Quote: ... 4 μL of the TnsBCTD-TnsC-TniQ sample was loaded on UltrAuFoil R1.2/1.3 gold grids (Quantifoil) and vitrified using the Mark IV Vitrobot (ThermoFisher ...
-
bioRxiv - Biophysics 2023Quote: 4 μL purified protein was placed on the holy-carbon grids (Quantifoil Au R1.2/1.3, 300 mesh), which were glow-discharged for 30 s ...
-
bioRxiv - Biophysics 2023Quote: ... 4 µL fresh sample was applied on glow-discharged Cu holey carbon grids (Quantifoil R 1.2/1.3) and incubated for 1 min at room temperature ...
-
bioRxiv - Bioengineering 2022Quote: ... A total of 3.5 μL of TP–AG treated MT samples was applied to a glow discharged holey carbon grid (Quantifoil R2/1). The grids were blotted ...
-
bioRxiv - Cell Biology 2021Quote: ... a thin layer of homemade continuous carbon was floated on top of individual Quantifoil R3.5/1 200 mesh gold grids (Quantifoil Micro Tools). After drying ...
-
bioRxiv - Cell Biology 2020Quote: ... 3 μl of samples were applied to glow-discharged Quantifoil R 0.6/1 and R 1.2/1.3 grids (Quantifoil Micro tools GmbH, Germany), blotted for 3 s and then flash frozen in liquid ethane using the automatic plunge freezer EM GP2 at 100% relative humidity ...
-
bioRxiv - Cell Biology 2021Quote: MEFs were grown to ~80% confluency on glow-discharged holey carbon EM grids (R2/1, Au 200 mesh; Quantifoil, Jena, Germany) prior to preparation for cryo-ET analysis ...
-
bioRxiv - Immunology 2022Quote: A 3.5 μL sample of concentrated pNO-decorated CLPs was applied to negatively glow discharged (25 mA, 40 s) R3.5/1 quantifoil copper grids (Quantifoil Micro Tools). The excess of solution was blotted using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Biochemistry 2023Quote: ... at a concentration of around 2.5 mg ml−1 were applied to glow-discharged 300-mesh Au grids (Quantifoil, R1.2/1.3). Excessive sample was removed by blotting with filter paper for 3.5 s before plunge-freezing in liquid ethane using a FEI Vitrobot Mark IV at 100% humidity and 8 °C.
-
bioRxiv - Biochemistry 2023Quote: MEFs were grown to ∼80% confluency on glow-discharged holey carbon EM grids (R2/1, Au 200 mesh; Quantifoil, Jena, Germany) prior to preparation for cryo-ET analysis ...
-
bioRxiv - Neuroscience 2024Quote: Extracted DS13 tau filaments were applied to 300-mesh copper R2/1 holey carbon grids (Quantifoil Micro Tools GmbH, Jena, Germany) that were glow-discharged for 30 s at a current of −30 mA on a PELCO easiGlowTM Glow Discharge Cleaning System ...
-
bioRxiv - Microbiology 2024Quote: ... 3.5 uL of the resulting sample were added to glow discharged Quantifoil Ultrathin carbon R2/1 200 mesh EM Grids (Ted Pella, Redding, CA, USA; Quantifoil Micro Tools GmbH ...
-
bioRxiv - Biochemistry 2020Quote: Quantifoil R2/2 300 mesh holey carbon copper grids (Quantifoil Micro Tools, Großlöbichau, Germany) were glow-discharged (ELMO Glow Discharge System ...
-
bioRxiv - Cell Biology 2022Quote: MEF were seeded on R2/2 holey carbon on gold grids (Quantifoil or Protochips) coated with fibronectin in a glass bottom dish (Mattek or Ibidi ...
-
bioRxiv - Cell Biology 2022Quote: ... The cells were seeded on EM grids (Quantifoil SiO2 R2/2, 200 mesh, gold) in a 3D printed specimen holder [43] and grown overnight.
-
bioRxiv - Molecular Biology 2023Quote: ... Quantifoil R1.2/1.3 400-square mesh Cu grids with 2 nm continuous carbon (Quantifoil) were glow-discharged for 8 s at 10 mA using a PELCO easiGlow glow discharging system (Ted Pella ...
-
bioRxiv - Biochemistry 2024Quote: ... Three microliters of sample were applied to glow-discharged R2/2 carbon grids (Quantifoil), which were blored for 5 s and at a blot force of 25 and plunge-frozen in liquid ethane with a Vitrobot Mark IV (ThermoFisher ...