Labshake search
Citations for Promega :
351 - 400 of 619 citations for glass bottom plate since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Pharmacology and Toxicology 2022Quote: ... Media was removed by spinning the inverted plates at 150g for 30 seconds followed by addition of BrightGlo (Promega) for quantification of P ...
-
bioRxiv - Molecular Biology 2022Quote: HEK-293T cells were plated in a 24-well plate at 400,000 cells per well before being transiently transfected with pGL3-control (Promega), a construct constitutively expressing a firefly luciferase ...
-
bioRxiv - Cell Biology 2022Quote: ... were seeded onto 6-well plates coated with 0.1 mg ml−1 poly-L-lysine and transfected using FuGENE HD transfection reagent (Promega) with a mixture of third-generation lentiviral backbone vector pJHUMCS that encodes BDNF-pHluorin ...
-
bioRxiv - Molecular Biology 2022Quote: ... cells were lysed in plate and luciferase activity was measured using Luciferase 1000 Assay System (Cat # E4550, Promega, WI).
-
bioRxiv - Molecular Biology 2024Quote: Cells were seeded in white 96-well plates and incubated with the RealTime-Glo MT Cell Viability Assay (Promega). Luminescence was detected using a GloMax-96 instrument (Promega).
-
bioRxiv - Molecular Biology 2023Quote: ... fresh bacmid DNA was transfected into Sf9 cells at 0.5×106 cells/mL in 6-well cell culture plates using FuGene HD (Promega) according to the manufacturer’s protocol (final concentration 10 μg/mL) ...
-
bioRxiv - Systems Biology 2023Quote: ... Plates were incubated at 37°C for 96 hours and lysed using CellTiter-Glo Reagent (Promega, catalog. no. G7570). Luminescence was measured using a PHERAstar FS instrument and growth inhibition was calculated relative to DMSO-treated wells.
-
bioRxiv - Microbiology 2023Quote: ... Sister plates were exposed to drug but not infected to gauge cytotoxicity using a CellTiter-Glo assay (CTG, Promega) at 48 hours post treatment ...
-
bioRxiv - Neuroscience 2023Quote: ... Tg(elavl3:EGFP)knu3 incross were individually placed in wells of 24-well plates in water containing 0.5 mM beetle luciferin (Promega). From ZT14 (the light to dark transition ...
-
bioRxiv - Bioengineering 2023Quote: ... Lysates (20 mg per well) were assessed in 96-well plates using 90 μl reconstituted Luciferase Assay Substrate (Promega) according to the manufacturer’s directions ...
-
bioRxiv - Immunology 2023Quote: ... Cells were lysed on the plate and incubated with luminescence glo regents per the luminescence glo assay kit’s instructions (Promega). Luminescence was recorded using a BioTek Synergy2 plate reader.
-
bioRxiv - Cell Biology 2023Quote: ... cells were plated on culture plates and transfected the next day with DNA constructs using FugeneHD reagent (#E2311, Promega), according to the manufacturer’s instructions.
-
bioRxiv - Developmental Biology 2023Quote: ... Bacteria were plated onto pre-warmed kanamycin resistance LB agar plates in the presence of X-gal (Promega, #V3941) for blue/white screening ...
-
bioRxiv - Immunology 2023Quote: ... RH5ΔNC-specific B cells were identified as live CD19+ IgG+ RH5ΔNC-APC+ RH5ΔNC-PE+ cells and single cell sorted into 96-well plates containing 10µL/well lysis buffer (10mM Tris [T3038, Merck], 1 unit/mL RNasin Ribonuclease Inhibitor [N2515, Promega]) and frozen at -80 °C.
-
bioRxiv - Immunology 2023Quote: ... Bacterial growth was followed for 24h or 18h with OD600nm measurements every 30 min using GloMax Plate Reader (Promega). Anaerobia was maintained with a O2 less sealing film (Sigma-Aldrich ...
-
bioRxiv - Microbiology 2023Quote: HFF or HEK293 cells (3 × 104 cells per well of a 24-well plate or 1 × 105 cells per well of a 6-well plate) were reverse transfected with 0.5 μg of pCW57-CMV-KDEL-mCherry-GF using Fugene HD (Promega) according to the manufacturer’s instructions ...
-
bioRxiv - Microbiology 2023Quote: ... Plates were then incubated at 37°C overnight before luciferase activity was quantified using the Luciferase Assay System (Promega) on SoftMax Pro v.7.0.2 (Molecular Devices) ...
-
bioRxiv - Microbiology 2023Quote: ... OD600nm was monitored every hour at 37°C for 24 h by using a GloMax Explorer plate-reader (Promega).
-
bioRxiv - Bioengineering 2024Quote: ... Cells were plated in black 96-well plates (Grenier Bio One) and furimazine (Promega, Nano-Glo Luciferase Assay System) was added to each well ...
-
bioRxiv - Cancer Biology 2024Quote: ... cells were plated in a 24-well plate at 90,000 cells per well and transfected with gRNAs using Fugene HD (Promega) at a manufacturer-suggested 3:1 reagent:DNA ratio ...
-
bioRxiv - Evolutionary Biology 2024Quote: ... WT or RIPK1 KO HEK293T cells were seeded in a white 96-well plate and transfected with firefly luciferase fused to either the NF-κB response element (pGL4.32, Promega) or the human IFN-beta promoter (IFN-Beta-pGL3 ...
-
bioRxiv - Cell Biology 2024Quote: ... Proliferation was measured seeding 1,000 cells per well in a 96-well plate with CellTiter Blue (Promega,cat. # G8081) over the indicated time period and a plate reader (Perkin Elmer Victor X5 ...
-
bioRxiv - Immunology 2024Quote: ... plates were washed 5 times with wash buffer (PBS with 1% BSA (Capricorn Scientific) and 0.05% Tween-20 (Promega)) ...
-
bioRxiv - Cell Biology 2024Quote: ... The cells were incubated for different time points and the viability was measured using CellTiter-Glo 2.0 and GloMax Plate reader (Promega).
-
bioRxiv - Cancer Biology 2024Quote: ... a set of assay plates which do not receive treatment were collected and ATP levels measured by adding CellTiter-Glo 2.0 (Promega). All data points were collected via automated processes and were subject to quality control ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... 105 HEK293T cells were seeded into 24-well plates and co-transfected with pGL4.10-based plasmids and pRL-SV40 Renilla luciferase plasmid (Promega). After 48 hours ...
-
bioRxiv - Cell Biology 2024Quote: ... Fresh bacmid DNA was transfected into Sf9 cells at 0.5×106 cells/mL in 6-well cell culture plates using FuGene HD (Promega) according to the manufacturer’s protocol (final concentration 10 µg/mL) ...
-
bioRxiv - Cell Biology 2024Quote: ... were performed according to manufacturer’s instructions and luminescence values measured on a GloMax Discover Plate Reader (Promega, Southampton, UK).
-
bioRxiv - Cell Biology 2024Quote: ... The lentiviral Titer Unit (TU) was extrapolated by measuring the fraction of viable cells with CellTiter-Glo 2.0 and GloMax Plate reader (Promega). For plasmids bearing a fluorescent probe ...
-
bioRxiv - Cancer Biology 2024Quote: ... plates were equilibrated to room temperature and 100 μL of room temperature Caspase-Glo 3/7 reagent (Promega G8091) was added to each well ...
-
bioRxiv - Cancer Biology 2021Quote: ... HEK293TN cells were seeded in 6-well plates and transiently transfected with plasmid of choice using FuGene transfection reagent (Promega) and OptiMem (Gibco) ...
-
bioRxiv - Neuroscience 2021Quote: ... Lysates were loaded in triplicate to 96-well microtiter plates and luminescence was measured in a GloMax 96 microplate luminometer (Promega). Gene expression was measured by firefly luciferase activity (LAR II ...
-
bioRxiv - Cancer Biology 2021Quote: ... The 96-well plate was then allowed to equilibrate at room temperature for 30 minutes followed by addition of Cell Titer Glo (Promega) to each well according to manufacturer instructions ...
-
bioRxiv - Cancer Biology 2021Quote: ... S2-CP8 cells were then transiently transfected with both mRFP-FKBP-5-ptase-dom and PM-FRB-CFP (0.5 μg/well of a 6-well plate for each vector) with ViaFect (Promega Corp.). After 24 h culture ...
-
bioRxiv - Cell Biology 2020Quote: ... 20 µL lysates were loaded into a 96 well plate and luminescence following administration of 50 µL Luciferase Assay Reagent II (Promega) and 50 µL Stop & Glo Reagent (Promega ...
-
bioRxiv - Neuroscience 2021Quote: ... coated 12-well plate and transfected the next day using the Fugene 6 transfection reagent and according to the manufacturer’s directions (Promega E2691). The same amount of plasmid was transfected per condition ...
-
bioRxiv - Molecular Biology 2021Quote: ... Cytotoxicity on mock infected plates was determined using the Promega CellTiter-Glow Luminescent Cell Viability Assay (Promega, Madison, Wisconsin, USA). Half-maximal inhibitory concentration (IC50 ...
-
bioRxiv - Developmental Biology 2020Quote: ... neural stem / progenitor cells were seeded in 96-well coated plates (1×104 cells per well) and RealTime-GloTM MT Cell Viability Assay (Promega) was used with the continuous-read protocol at 0 ...
-
bioRxiv - Neuroscience 2021Quote: ... and incubated 1:1 for 5 minutes in the dark in opaque 96 well plates with NanoGlo Substrate freshly diluted 1:50 in NanoGlo Buffer (Promega). Luminescence was measured on a GloMax 96 Microplate Luminometer.
-
bioRxiv - Biophysics 2022Quote: ... The reaction was further incubated for 60 min at room temperature prior to measuring absorbance with a plate-reading luminometer (GloMax, Promega). Samples were correlated to phosphate concentration standard controls ...
-
bioRxiv - Microbiology 2021Quote: ... NF54-HGL parasites were treated with 3× IC50 for two weeks in two independent experiments and cultures were monitored by luminescence readout on the BioTek Synergy 2 Plate reader using ONE-Glo reagent (Promega). Whole-genome sequencing was performed to test for single nucleotide polymorphisms (SNPs ...
-
bioRxiv - Bioengineering 2021Quote: ... Luminescence was measured with a FluoStar Omega plate reader (BMG Labtechnologies) and treated with the protocol and reagents of the Dual-Luciferase Reporter Assay System (Promega). All reagents were used accordingly to the manufactures protocol.
-
bioRxiv - Bioengineering 2020Quote: ... Luminescence from the activity of luciferase was measured 48 h post-infection using a TECAN infinite M200 pro plate reader after applying Bright-Glo reagent (Promega) on cells.
-
bioRxiv - Cancer Biology 2020Quote: ... 20 μL of cell lysate was transferred to 96-well plates and placed in a 96-well microplate luminometer (GloMax-Multi, Promega). 100 μL Luciferase Assay Reagent II and 100 μL Stop & Glo Reagent (both provided in the Dual-Luciferase Reporter kit ...
-
bioRxiv - Cancer Biology 2020Quote: ... and 50 μl of diluted media added to a white 96 well plate (CLS3610) before the addition of 50 μl of Lactate/Glucose detection reagent (Promega). Plates were incubated for 1 h at RT and luminescence recorded (Glowmax Luminometer ...
-
bioRxiv - Cancer Biology 2020Quote: ... The cell lysates were transferred to a 96-well black plate and then an equal volume of Luciferase assay reagent (Promega) was added ...
-
bioRxiv - Biochemistry 2021Quote: ... and firefly luciferase expression was measured on a Berthold Centro LB 960 plate luminometer using D-luciferin as a substrate (Promega). Percentage of infectivity was calculated as the ratio of luciferase readout in the presence of mAbs normalized to luciferase readout in the absence of mAb ...
-
bioRxiv - Microbiology 2020Quote: ... the plate was incubated at room temperature for 10 minutes to stabilize luminescent signal before luminescence was recorded on a GloMax plate reader (Promega).
-
bioRxiv - Microbiology 2021Quote: ... Plates were incubated for 30 minutes in the dark before being read at 405 nm on a GloMax Explorer (Promega).
-
bioRxiv - Pharmacology and Toxicology 2021Quote: ... were seeded in a 6-well plate and transfected with 750 ng of each of the AT1R-TANGO plasmids using FUGENE 6 Transfection (PROMEGA). The following day ...