Labshake search
Citations for Lucigen :
651 - 700 of 750 citations for Protein DNA Interaction Assay since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Plant Biology 2021Quote: ... a PCR-free library was prepared with the NxSeq® AmpFREE Low DNA Library Kit (Lucigen, Middleton, WI, USA) according to the manufacturer’s instructions ...
-
Lessons from the meiotic recombination landscape of the ZMM deficient budding yeast Lachancea waltiibioRxiv - Genetics 2021Quote: ... waltii isolates as well as the generated hybrids were extracted using a modified MasterPure Yeast DNA purification protocol (Lucigen).
-
bioRxiv - Microbiology 2020Quote: ... HBV cccDNA was quantified from total DNA following digestion for 45 min at 37°C with T5 exonuclease (Epicentre) to remove rcDNA followed by 30 min heat inactivation ...
-
bioRxiv - Cancer Biology 2021Quote: ... These primers were used to amplify cell pools after DNA extraction using Quick Extract (Lucigen, Wisconsin, USA, Cat #QE09050). Amplified reads were sequenced on either an Illumina MiSeq or Illumina HiSeq 2500.
-
bioRxiv - Cancer Biology 2022Quote: ... A minimum of 1.2ug of ligated pUSEPR plasmid DNA per sub-pool was electroporated into Endura electrocompetent cells (Lucigen), recovered for one hour at 37°C ...
-
bioRxiv - Genomics 2022Quote: ... A total of 1.2 µg of ligated pUSEBR-CRISPR Library plasmid DNA was then electroporated into Endura electrocompetent cells (Lucigen). Competent cells were recovered for 1 h at 37ºC ...
-
bioRxiv - Bioengineering 2019Quote: Cells in 96 well plates were washed once with PBS before addition of QuickExtract™ DNA Extraction Solution (Lucigen). The volume was adjusted based on the estimated cell number ...
-
bioRxiv - Microbiology 2020Quote: ... Three μg of purified DNA were treated with 2 μl of Plasmid-Safe ATP-dependent exonuclease (Epicentre, Madison, USA) at 37°C for 30 minutes and then heat-inactivated by a 30-min incubation at 70°C.
-
bioRxiv - Neuroscience 2019Quote: ... 20pg of in vitro transcribed RNA synthesized from the T7 control DNA Template (AmpliScribe™ T7 Transcription Kit, Epicentre) was added to the samples ...
-
bioRxiv - Cancer Biology 2020Quote: ... HBV plasmid (positive control) and HBV DNA from inoculum was digested with plasmid-safe DNase (Epicentre, E3101K, Madison, WI). According to the manufacturer’s protocol ...
-
bioRxiv - Evolutionary Biology 2022Quote: ... Purified genomic DNA from each individual was used to prepare paired-end libraries (Lucigen Shotgun library preparation, PCR free) and sequenced on an Illumina HiSeq X PE 150 bp platform to 10-20X coverage at the Centre d’ Expertise et de Services ...
-
bioRxiv - Cell Biology 2022Quote: ... Isolated genomic DNA was combined with EconoTaq PLUS GREEN 2X Master Mix (cat# 30033-1; Lucigen, Middleton, WI, USA) and forward and reverse primers (primer information listed in Table S2 ...
-
bioRxiv - Biochemistry 2023Quote: ... Isolated DNA was used to construct a fosmid library using the CopyControl™ Fosmid Library Production kit (Lucigen Corporation) following the manufacturer’s instructions.
-
bioRxiv - Bioengineering 2023Quote: ... Supernatant were carefully discarded and the isolated hair cells were lysed by 5μl QuickExtract™ DNA Extraction Solution (Lucigen) and incubated in 65°C for 6 min then 98°C 3 min ...
-
bioRxiv - Microbiology 2023Quote: ... The sample was spun down at 10,000 rcf for 1 min and the supernatant was added to 150 μl of protein precipitation reagent (Epicentre, Lucigen, Middleton, WI). Remaining steps followed the recommended PureLink Genomic DNA Mini Kit (Invitrogen ...
-
bioRxiv - Genetics 2021Quote: ... columns and approximately 120–150 ng of DNA was used as template for a T7 in vitro transcription (IVT) reaction (AmpliScribe-T7-Flash transcription kit from Epicentre). In vitro transcribed gRNAs were DNAse-treated using TURBO-DNAse for 20 min at 37 °C and precipitated with sodium acetate/ethanol and resuspended in RNAse and DNAse free water ...
-
bioRxiv - Molecular Biology 2021Quote: ... pre-digested DNA was extracted and further incubated with 20 U plasmid-safe DNase (PS-DNase, Lucigen®, Epicentre, UK) and 1mM ATP at 37 °C for 24 h ...
-
bioRxiv - Molecular Biology 2021Quote: ... pre-digested DNA was extracted and further incubated with 20 U plasmid-safe DNase (PS-DNase, Lucigen®, Epicentre, UK) and 1mM ATP at 37 °C for 24 h ...
-
bioRxiv - Cell Biology 2022Quote: ... At this stage a small aliquot of cells (75% of the plate) was lysed in 200 μL of QuickExtract DNA Extraction solution (Lucigen) and gDNA was prepared by heating to 65° C for 10 minutes followed by heat inactivation at 95° C for 2 minutes ...
-
bioRxiv - Developmental Biology 2020Quote: ... Nematodes were washed individually from each mapping line in approximate equal pellet sizes prior to pooling and genomic DNA extraction using the MasterPure Kit (Epicentre). We sequenced the whole genomes of tu391 and csu60 ...
-
bioRxiv - Immunology 2019Quote: ... washed once in PBS and genomic DNA was recovered from 1 x 106 cells using 100 μl Quick Extract solution (Epicentre) according to the manufacturer’s instructions ...
-
bioRxiv - Biochemistry 2020Quote: ... 124 nt oligonucleotides (IDT) (see Supplementary Table S7) were circularized using with CircLigase™ single stranded (ss) DNA Ligase (Lucigen) according the manufacturers suggestion ...
-
bioRxiv - Neuroscience 2020Quote: DNA from six PVN from each supplemental tactile stimulation group in the repeated room temperature condition and nest temperature condition (total n = 24) was extracted using the Masterpure Complete DNA/RNA Extraction kit (Epicentre) and 300 ng of DNA was used for bisulfite conversion using the Epitect Fast Bisulfite Conversion kit (Qiagen ...
-
bioRxiv - Microbiology 2021Quote: ... and aliquots of 100 μL were dispensed into 0.1 mm gapped electroporation cuvettes along with 1 μg of plasmid DNA and 1 μL of Type-One restriction inhibitor (Epicentre). Electroporation was performed with a Bio-Rad Micropulser (Ec3 pulse ...
-
bioRxiv - Genomics 2020Quote: ... Multiple PCR reactions for each sample were carried out with 200 pg of annealed DNA using the XpYpE2 and teltail primers (Supplementary Table 3) and FailSafe PCR reagents (Epicentre). PCR conditions were as follows ...
-
bioRxiv - Cell Biology 2021Quote: ... The 3’ ends of the restricted and CPD-incised DNA fragments were ligated to Illumina sequencing adapters by using Circligase (Lucigen). After PCR amplification ...
-
bioRxiv - Microbiology 2022Quote: ... electroporated with Rmona658B genomic DNA that had been linearized by digestion with SmaI and ligated into the linear vector pJAZZ (Lucigen). The resulting construct was termed pJAZZ[pRM658B] (Fig ...
-
bioRxiv - Microbiology 2022Quote: ... The resulting air-dried pellets were resuspended in RNase-free water and 3 µg of DNA from each sample was depleted of ribosomal RNA using the Bacteria Ribo-Zero rRNA Removal Kit (Epicentre) and purified using the RNeasy miniprep kit (Qiagen) ...
-
bioRxiv - Microbiology 2022Quote: ... Clonal populations were genotyped by Sanger sequencing the PCR amplified sgRNA-targeted sites in the gDNA extracted using DNA QuickExtract (Lucigen). Resulting sequences were compared to references and clones containing a frameshift indel or de novo stop codon were selected ...
-
bioRxiv - Genomics 2022Quote: ... Subsequent library preparation was performed with the NxSeq® AmpFREE Low DNA Library Kit (Lucigen®; Cat. no. 14000-1) according to the manufacturer’s instructions with one slight modification ...
-
bioRxiv - Evolutionary Biology 2021Quote: ... The library prep was performed according to the manufacturer’s instructions for the NxSeq® AmpFREE Low DNA Library Kit from Lucigen® (Cat No ...
-
bioRxiv - Developmental Biology 2020Quote: ... Cell debris was then pelleted and used for gDNA extraction with 10-20 µl QuickExtract™ DNA Extraction Solution (Lucigen) according to the manufacturer’s instructions ...
-
bioRxiv - Bioengineering 2020Quote: ... After mutagenesis DNA sublibrary pools were digested with appropriate restriction enzymes to remove phagemid template before transformation into SS320 electrocompetent cell (Lucigen) for phage production ...
-
bioRxiv - Microbiology 2019Quote: ... and transposomes were prepared by mixing purified transposon DNA with EZ-Tn5 transposase according to the supplier’s instructions (Lucigen Corp). The mixture was incubated at 37°C for 1 h then stored at −20°C before use.
-
bioRxiv - Microbiology 2020Quote: Genes were amplified by PCR using the appropriate primers and the amplified DNA cloned in pET28b using NheI/XhoI restriction sites or pETite (ExpressoTM T7 cloning and expression system, Lucigen) generating constructs with either N- or C-terminal His6 tags (Supplementary Table 7) ...
-
Macrobdella decora: Old World Leech Gut Microbial Community Structure Conserved in a New World LeechbioRxiv - Microbiology 2019Quote: MasterPure complete DNA extraction without column purification into 50μL TE was performed according to manufacturer’s protocol (Epicentre Madison, WI U.S.A.). No significant difference was found between the two extraction methods (PERMANOVA ...
-
bioRxiv - Genetics 2020Quote: ... DNA was isolated from tail snips of MyD88 CRISPy TAKO and Mock-treated control offspring using Quick Extract (Lucigen, #QE09050). Primers for MyD88 genotyping are listed in Table 1 ...
-
bioRxiv - Microbiology 2021Quote: Total RNA was extracted from harvested cultures using the Masterpure™ Complete DNA and RNA Kit (Lucigen Corporation, Middleton, Wisconsin). RNA was subsequently purified using the Zymo RNA Clean and Concentrator™ Kit (Zymo Research ...
-
bioRxiv - Microbiology 2020Quote: Samples were analyzed directly or mixed 1:1 with one of the following buffers: Quick Extract DNA Extraction Solution (Lucigen), Virotype Tissue Lysis Reagent (INDICAL BIOSCIENCE GmbH ...
-
bioRxiv - Genomics 2021Quote: ... 11 μL purified CUT&Tag-DNA was used in the reaction (11 μL DNA, 2 μL 10 μM Tn5mC-ReplO1 oligo, 2 μL 10× Ampligase buffer (Lucigen), 2 μL dNTP mix (2.5mM each ...
-
bioRxiv - Molecular Biology 2020Quote: ... Comparable results to commercial RNA extraction kits have been obtained using a 5-min direct detection preparation method of nasopharyngeal samples following 1:1 dilution with the Quick Extract DNA extraction Solution (Lucigen) (6) ...
-
bioRxiv - Microbiology 2022Quote: ... 1 kb regions directly upstream and downstream of the hsdS open reading frame were amplified from genomic DNA of the respective strains and annealed to either side of a chloramphenicol resistance cassette (Tn5 HyperMu transposon, Epicentre) using overlap extension PCR ...
-
bioRxiv - Biochemistry 2022Quote: ... the electroporated T cells were pelleted and gDNA was isolated by adding 50 μL/well QuickExtract DNA extraction solution (Epicentre), followed by incubation at 37 °C for 10 minutes ...
-
bioRxiv - Molecular Biology 2022Quote: ... The reaction was then stopped with the addition of 190 µl lysis buffer (from MasterPure Yeast DNA Purification Kit (Lucigen)) ...
-
bioRxiv - Synthetic Biology 2022Quote: ... 1 μL of each required DNA fragment and corresponding bridging oligo were added to 2.5 μL of Ampligase 10X Reaction Buffer (Lucigen, USA), 2.25 μL of 5 M betaine ...
-
bioRxiv - Molecular Biology 2022Quote: Approximately 1e+06 cells were harvested two days post nucleofection and incubated in 200 μL of QuickExtract DNA Extraction Solution (Lucigen) at 65ºC for 15 minutes ...
-
bioRxiv - Molecular Biology 2022Quote: ... The fragmented gDNA was ended-repaired in 50 μl reaction using the End-It DNA End-Repair Kit (Lucigen, ER81050), incubated at room temperature for 45 min ...
-
bioRxiv - Molecular Biology 2023Quote: ... Single clones were expanded and genotyped for the desired knock-in by PCR on genomic DNA extracted with Quickextract solution (Lucigen). Clones showing biallelic knock-ins were expanded and frozen in LN2 at early passages ...
-
bioRxiv - Microbiology 2022Quote: RNA from endodontic samples was extracted using the MasterPure Complete DNA and RNA Purification Kit (Epicentre Technologies, Madison, WI, USA) following the manufacturer’s protocol ...
-
bioRxiv - Genomics 2023Quote: ... 200µL of the cell suspension was washed twice in PBS and genomic DNA was extracted with Quickextract solution (Lucigen, QE0905T) according to the manufacturer’s protocol.