Labshake search
Citations for Agilent :
6801 - 6850 of 9205 citations for Mouse Autophagy related protein 16 1 ATG16L1 ELISA Kit since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2021Quote: ... RpoB E310A and RpoB E310K were made by site-directed mutagenesis of the wild type constructs using the Quikchcange II XL kit (Agilent). B ...
-
bioRxiv - Biochemistry 2020Quote: ... The pcDNA3.1 Hygro-DEST_VGLL2_Ω_loop mutant was generated by use of the QuikChange Lightning Site-Directed Mutagenesis kit (Stratagene, San Diego, CA), with oligo 5’CCC TTG GAG AGA CTG CAG CTT CTA TCA GGC TCC TGT GCC 3’ (removing amino acid positions 134-149 ...
-
bioRxiv - Microbiology 2021Quote: ... Quantity and quality of RNA was assessed on an Agilent 2100 Bioanalyzer using Agilent RNA 6000 Nano kit (Agilent, USA). Extracted RNA was reverse-transcribed to cDNA using SuperScript™ IV First-Strand Synthesis System (Invitrogen™ ...
-
bioRxiv - Genomics 2020Quote: ... with a Qubit RNA BR (Broad-Range) or Qubit RNA HS assay kit and with RNA Screen Tape and Sample buffer using TapeStation 4150 (Agilent). RNA with an RNA integrity number (RIN ...
-
bioRxiv - Genomics 2020Quote: ... Total RNA integrity and quantity of the samples were assessed using the Agilent 2100 Bioanalyzer with the RNA 6000 Nano LabChip Kit (Agilent) and NanoDrop 1000 Spectrophotometer (Thermo Scientific).
-
bioRxiv - Genomics 2021Quote: ... and the quality was assessed using an Agilent 2100 Bioanalyzer with a High Sensitivity DNA analysis kit (Agilent, 5067-4626).
-
bioRxiv - Genomics 2021Quote: ... The concentration and size distribution of the immunoprecipitated DNA was measured using the Bioanalyzer High Sensitivity DNA kit (#5067-4626, Agilent). Dana-Farber Cancer Institute Molecular Biology Core Facilities prepared libraries from 2 ng of DNA ...
-
bioRxiv - Immunology 2021Quote: ... RNA integrity was assessed using Eukaryote Total RNA Nano Kit on the Bioanalyzer 2100 system (Agilent Technologies, Santa Clara CA). 500 ng of RNA ...
-
bioRxiv - Developmental Biology 2021Quote: ... The quality of the extracted RNA was analysed using the RNA 6000 Nano kit on a 2100 Bioanalyzer (Agilent, USA). An aliquot of 500 ng of RNA was used to prepare a polyadenylated RNA library with the TruSeq Stranded mRNA Library Prep Kit (Illumina ...
-
bioRxiv - Immunology 2021Quote: ... Total RNA was amplified and Cy3 labeled by using the one-color Low Input Quick Amp Labeling Kit (Agilent Technologies) according to the manufacturer’s protocol ...
-
bioRxiv - Genomics 2021Quote: ... with an average fragment length of 625 bp (ranging from 300 to 2000 bp, measured with the Bioanalyzer High Sensitivity DNA Kit, Agilent). The prepared library was sequenced on an Illumina NovaSeq 6000 Sequencing System with S4 flow cells ...
-
bioRxiv - Microbiology 2021Quote: ... and Spir-1 and K7 plasmids were used as templates for site-directed mutagenesis according to the instructions of the QuikChange Site-Directed Mutagenesis Kit (Agilent). All mutations were confirmed by DNA sequencing ...
-
bioRxiv - Neuroscience 2021Quote: ... Cells were reselected for two rounds and finally transferred using a new capillary with 30-μm tip diameter to 100-μl lysis buffer (Absolutely RNA Nanoprep Kit; Agilent). Cells of multiple collections were pooled if needed to obtain 200 cells per sample ...
-
bioRxiv - Microbiology 2021Quote: ... Mutant SARS-CoV-2 expression plasmids were generated by site-directed mutagenesis using the QuikChange Lightning Multi Site-Directed Mutagenesis Kit (Agilent). Unless otherwise stated all SARS-CoV-2 spike expression plasmids were based on the Wuhan-hu-1 reference sequence 41 ...
-
bioRxiv - Neuroscience 2020Quote: ... The final product was assessed for its size distribution and concentration using a BioAnalyzer High Sensitivity DNA Kit (Agilent Technologies) and loaded onto an S1 flow cell on an Illumina NovaSeq 6000 (Illumina ...
-
bioRxiv - Cancer Biology 2021Quote: ... The average length of the final libraries was quantified using a Fragment Analyzer (HS NGS Fragment kit, Agilent, DNF-474) and the concentration of libraries was determined using a Qubit 1X dsDNA HS kit (Thermo Fisher ...
-
bioRxiv - Microbiology 2021Quote: Total extracted RNA quality was confirmed for sequencing using the Agilent 2100 Bioanalyzer system using the RNA 6000 Pico Kit (Agilent). Bacterial and mammalian rRNA depletion ...
-
bioRxiv - Biochemistry 2020Quote: ... an XhoI restriction site was introduced after DrBphP residue 513 with QuikChange Lightning Multi Site-Directed Mutagenesis Kit (Agilent Technologies). Then ...
-
bioRxiv - Bioengineering 2021Quote: ... RNA integrity was assessed using an RNA Nano 6000 Assay Kit from the Bioanalyzer 2100 system (Agilent Technologies, CA, USA). The RNA-seq library was then generated using the NEBNext® Ultra™ RNA Library Prep Kit for Illumina® (NEB ...
-
bioRxiv - Biochemistry 2021Quote: ... Library size and quality was assessed using the Fragment Analyzer DNF-474 High Sensitivity NGS Fragment Analysis kit (Agilent Technologies). Concentrations of each library were quantified using the KAPA Library Quantification Kit for Illumina (Roche ...
-
bioRxiv - Developmental Biology 2021Quote: ... The catalytically dead mutants MMP28EA-pCS2 and MMP28EA-ΔSP/NLS-GFP-pCS2 were produced by point mutation of Glutamic acid226 to Alanine from MMP28wtpCS2 and Glutamic acid209 to Alanine from MMP28ΔSP/NLS-GFP-pCS2 using QuikChange II site-Directed Mutagenesis Kit (Agilent #200523) with the primers MMP28_E-A_fdw ...
-
bioRxiv - Biochemistry 2020Quote: Site-directed mutagenesis of BAK1 scFv coding sequence into pCANTAB6 was performed following the manufacturer’s instructions in the QuikChange Site-Directed Mutagenesis Kit (Agilent Technologies). The mutations introduced in the BAK1 or the BAK1-INS1 template sequences were ...
-
bioRxiv - Biochemistry 2020Quote: ... The error-prone PCR (epPCR) library of the gene encoding qmLC/A was created with the GeneMorph II kit (Agilent) according to the manufacturer’s instructions ...
-
bioRxiv - Biochemistry 2020Quote: The FANCD2 S592A and S592D cDNAs were generated by site-directed mutagenesis of the wild type FANCD2 cDNA using the Quikchange Site-directed Mutagenesis Kit (Stratagene). The forward (FP ...
-
bioRxiv - Biochemistry 2020Quote: ... The gene coding for the H349Y GlgE variant was generated from the synthesized wild-type glgE gene using a QuikChange Lightening kit (Agilent). The constructs were ligated into pET21a expression vectors (Novagen ...
-
bioRxiv - Microbiology 2021Quote: ... and the Spike from the B.1.429 lineage (S13I, W152C, L452R, D614G) were generated using the QuikChange II XL site-directed mutagenesis kit (Agilent Technologies). The amino acid deletions in the full-length SARS-CoV-2 Spike expressor were generated using the Q5 site-directed mutagenesis kit (NEB) ...
-
bioRxiv - Cancer Biology 2021Quote: ... RNA integrity was evaluated with Agilent Bioanalyzer 2100 and RNA 6000 Nano Kit (Cat-No. G2939BA & 5067-1511, Agilent, Germany). RNASeq libraries were prepared using illumina® TrueSeqTM Stranded mRNA Library Prep Kit ...
-
bioRxiv - Cancer Biology 2021Quote: ... product size distribution and quantity were assessed on a Bioanalyzer using a High Sensitivity DNA Kit (Agilent Technologies 5067-4628). A total of 140 pg of the amplified cDNA was fragmented using Nextera XT DNA sample preparation kit (Illumina FC-131-1096 ...
-
bioRxiv - Biophysics 2021Quote: The triplex-forming regions were incorporated into the parent plasmids by site-directed mutagenesis using the QuikChange Site-Directed Mutagenesis Kit (Stratagene) following the manufacturer’s protocol ...
-
bioRxiv - Biophysics 2020Quote: Mutations were generated in previously-described single-round plasmid derivatives of HIV-1NL4-3 (pNLdE-luc)48 and HIV-1LAI (pBru3ori-ΔEnv-luc2)49 that encoded for luciferase via the QuikChange site-directed PCR mutagenesis kit (Agilent). Resulting plasmid DNAs were verified by Sanger sequencing ...
-
Scanning mutagenesis of RNA-binding protein ProQ reveals a quality control role for the Lon proteasebioRxiv - Microbiology 2021Quote: ... The purified PCR products were subsequently used as megaprimers to generate the library of mutants in the plasmid pZE-ProQ-3×FLAG by following GeneMorph II EZClone Domain Mutagenesis Kit (Agilent) guidelines ...
-
bioRxiv - Cancer Biology 2020Quote: ... The slides were washed the next day and then incubated with biotinylated anti-rabbit secondary antibody using a DAB kit (Dako) according to the manufacturer’s protocol ...
-
bioRxiv - Cancer Biology 2020Quote: ... Library and cDNA quality and profile were confirmed prior to sequencing ran on an Agilent Bioanalyzer using a Bioanalyzer High Sensitivity DNA Analysis kit (Agilent). Prepared library was then sequenced using 150 paired-end cycles on a NovaSeq S4 flow cell (Illumina).
-
bioRxiv - Cancer Biology 2020Quote: ... The quality of RNA was evaluated using a Bioanalyzer 2100 with RNA 6000 Nano LabChip kit (5067-1511, Agilent Technologies). mRNA-seq libraries were prepared using TruSeq Stranded mRNA Library Prep Kit (RS-122-2101 ...
-
bioRxiv - Plant Biology 2021Quote: ... Library fragment size distribution was checked on the Agilent 2100 Tapestation System with the High Sensitivity D1000 Kit (Agilent Technologies). A total of six RNA sequencing libraries were sequenced on Nova Seq 6000 Platform (Illumina).
-
bioRxiv - Plant Biology 2020Quote: ... The integrity of the DNAse treated RNA was confirmed by capillary electrophoresis using the Agilent Bioanalyzer and the Agilent RNA 6000 Nano kit (#5067-1511, Agilent) according to the manufacturer’s instructions.
-
bioRxiv - Biochemistry 2020Quote: ... Site directed mutagenesis was performed on pRK5-HA-GβL using the Quik-Change II Site Directed mutagenesis kit (200523, Agilent Technologies) as per the manufacturer’s instructions ...
-
bioRxiv - Biochemistry 2020Quote: The modified pVote0GW vector used for wild-type hTop2α overexpression was mutated by site directed mutagenesis using the QuikChange XL Site-Directed Mutagenesis kit (Agilent) in order to generate the plasmids harboring K418A ...
-
bioRxiv - Cell Biology 2021Quote: ... were created by point mutations on the pcDNA3.1-Cyb5r3 (WT) plasmid using QuikChange II XL Site-Directed Mutagenesis Kit (Agilent, 200521). Mutagenesis primers were designed using Agilent’s online program ...
-
bioRxiv - Cell Biology 2021Quote: ... Point mutations and truncations were generated by site-directed mutagenesis using the QuikChange II Site-Directed mutagenesis kit (Agilent #200524) and verified by sequencing ...
-
bioRxiv - Plant Biology 2021Quote: ... The SEGS-2 ATG mutant (pNSB2110) was created in S2-1.5b (pNSB1869) using the QuickChange II Site-Directed Mutagenesis Kit (Agilent Technologies) and the primers ...
-
bioRxiv - Plant Biology 2020Quote: ... RNA integrity was assessed using the RNA Nano 6000 Assay Kit of the Bioanalyzer 2100 system (Agilent Technologies, CA, USA). The sequencing libraries preparation and high-throughput sequencing were carried out by Novogene Bioinformatics Technology CO. ...
-
bioRxiv - Plant Biology 2020Quote: ... concentration and integrity was evaluated on 0.8% agarose gels and by the RNA Nano 6000 Assay Kit using Bioanalyzer instrument (Agilent Technologies). For RNA-seq analysis ...
-
bioRxiv - Microbiology 2020Quote: One-step site directed mutagenesis was conducted on EhDHS1 and EhDHS2 gene by QuikChange Site-Directed Mutagenesis Kit (Agilent Technologies). Overlapping primers for site-directed mutagenesis were designed to replace phenylalanine at amino acid 302 of the pCOLD-EhDHS2 plasmid with lysine ...
-
bioRxiv - Microbiology 2020Quote: ... and the library quality and size distribution (~230 bp peak size) was checked using a 2100 Bioanalyzer with the High Sensitivity DNA kit (Agilent). Sequencing of pooled libraries ...
-
bioRxiv - Microbiology 2020Quote: ... and the library quality and size distribution (~480 bp peak size) was checked using a 2100 Bioanalyzer with the High Sensitivity DNA kit (Agilent). Sequencing of pooled libraries ...
-
bioRxiv - Microbiology 2020Quote: ... A PCR enrichment test was performed in order to determine the number of PCR cycles that are nesessery for each pool followed by a bead purification step and a QC with DNA HS kit (Agilent). Then ...
-
The circadian clock gene circuit controls protein and phosphoprotein rhythms in Arabidopsis thalianabioRxiv - Systems Biology 2021Quote: ... Phosphopeptides were enriched using the Titansphere™ spin tip kit (GL Sciences Inc.) and desalted on BondElut Omix tips (Agilent) according to the manufacturers’ instructions.
-
bioRxiv - Microbiology 2020Quote: ... ftsL30-121 and ftsW were introduced into some plasmids by using the QuickChange site-directed mutagenesis kit according to the manufacturer’s instruction (Agilent Technologies).
-
bioRxiv - Neuroscience 2020Quote: The single-cysteine mutations of GuD2 were generated by site-directed mutagenesis using the Quick Change II kit (Agilent technology) performed on pcDNA3-GluD220 ...