Labshake search
Citations for Agilent :
1 - 50 of 10000+ citations since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2024Quote: ... Western blotting analysis was carried out using standard protocols with the antibodies listed in Table_1 and HRP-conjugated secondary antibodies (Agilent). Bands were visualised bu SuperSignal West Fempto ECL substrate (Thermo ...
-
bioRxiv - Cancer Biology 2024Quote: ... primary antibodies were typically diluted in antibody Diluent (DAKO, S2022) with 2% milk (v/v ...
-
bioRxiv - Cancer Biology 2024Quote: ... substrate red (Dako, K5005) was applied for 10 minutes at room temperature before slides were washed ...
-
bioRxiv - Plant Biology 2024Quote: ... and the absorbance was measured using a spectrophotometer (Agilent BioTek Synergy H1) at wavelengths of 475 ...
-
bioRxiv - Plant Biology 2024Quote: ... Metabolite detection and annotation were performed by Quant software (Agilent, Santa Clara, CA, USA), according to an accurate mass library of known markers generated by our group and run in the same system ...
-
bioRxiv - Plant Biology 2024Quote: ... RNA concentration and integrity were measured using an Agilent 2100 bioanalyzer (Agilent Technologies, Inc., United States). Samples with a RIN (RNA integrity number ...
-
bioRxiv - Cancer Biology 2024Quote: ... and integrity of total RNA were determined by electrophoresis in a 4200 TapeStation system (Agilent, Santa Clara, CA, USA). Whole transcriptome sequencing (RNA-Seq ...
-
bioRxiv - Plant Biology 2024Quote: ... The vials were sealed using crimp-top caps with TFE-silicone headspace septa (Agilent). At the time of SPME analysis ...
-
bioRxiv - Plant Biology 2024Quote: ... 500 mg (1 mL) of the powder was transferred immediately to a 20 mL head-space vial (Agilent, CA, USA), containing NaCl saturated solution ...
-
bioRxiv - Neuroscience 2024Quote: ... oxygen consumption rates and extracellular acidification rates were measured using a 96-well Seahorse Bioanalyzer XF 96 according to the manufacturer’s instructions (Agilent Technologies).
-
bioRxiv - Plant Biology 2024Quote: RNA quality was examined using a 2100 Bioanalyzer (Agilent). The RNA integrity number was above 8.0 in all samples ...
-
bioRxiv - Physiology 2024Quote: ... then later analyzed by the Interdisciplinary Center for Plasma Mass Spectrometry at the University of California at Davis (ICPMS.UCDavis.edu) using an Agilent 8900 ICP-MS Triple Quad instrument (Agilent Technologies, Santa Clara, CA 95051).
-
bioRxiv - Neuroscience 2024Quote: ... using the Mito Stress Test and Glycolysis Stress Test (Agilent). Cerebellar cells were plated in 96-well Seahorse XF Cell Culture Microplates plates and analyzed at DIV17 ...
-
bioRxiv - Physiology 2024Quote: ... tissues were incubated with primary antibody over night at 4°C (guinea pig anti-insulin at 1:4, diluted in 1% goat serum/PBS, Agilent). This was followed by 1-hour incubation with fluorophore-conjugated secondary antibodies (Cy3-anti-guinea pig ...
-
bioRxiv - Neuroscience 2024Quote: ... for 2 min at 15 ul flow before reverse-flushed onto an in-house packed analytical column (30 cm length, 75 µm inner diameter, filled with 2.7 µm Poroshell EC120 C18, Agilent). Peptides were chromatographically separated at a constant flow rate of 300 nL/min and the following gradient ...
-
bioRxiv - Physiology 2024Quote: ... Total bile acids assay (Diazyme Laboratories, CA, USA) and BioTek Epoch Microplate Spectrophotometer (Agilent Technologies, CA, USA) were used to measure total BA concentrations to determine the volume of cholestyramine-untreated extract needed to add for a final concentration of ∼300 μM BAs in the ileal explant culture media ...
-
bioRxiv - Neuroscience 2024Quote: ... Final library concentration was assessed by Qubit dsDNA HS Assay Kit (Thermo-Fischer Scientific) and fragment size was checked using Tapestation High Sensitivity D1000 (Agilent) to ensure that fragment sizes were distributed normally about 500 bp ...
-
bioRxiv - Physiology 2024Quote: ... The following primary antibodies were used: guinea pig anti-insulin (Dako A0564, 1:1000), rat anti-BrdU (Novus Biologicals NB500-169 ...
-
bioRxiv - Neuroscience 2024Quote: ... Library profile and concentration were assessed using a TapeStation (Agilent). Library concentration was also analyzed using a Qubit fluorometer ...
-
Activation of XBP1s attenuates disease severity in models of proteotoxic Charcot-Marie-Tooth type 1BbioRxiv - Neuroscience 2024Quote: ... and retrotranscribed as previously described.16 cDNAs were quantified by quantitative real-time PCR on a MX3000 apparatus (Stratagene, La Jolla, CA, USA) by using specific primers ...
-
bioRxiv - Neuroscience 2024Quote: ... Point amino acid substitutions in genes encoding GluN subunits were performed using the QuikChange site-directed mutagenesis kit (Agilent Technologies) and verified by DNA sequencing.
-
bioRxiv - Neuroscience 2024Quote: ... The size distribution of the libraries was determined using a High Sensitivity DNA chip on a Bioanalyzer 2200 (Agilent, Santa Clara, CA, USA). All libraries were sequenced by Novaseq6000 (Illumina ...
-
bioRxiv - Neuroscience 2024Quote: ... Their size distribution was determined using a High-sensitivity DNA chip on a Bioanalyzer 2200 (Agilent, Santa Clara, CA, USA). All libraries were sequenced in 150-bp paired-end runs on an Illumina sequencer (San Diego ...
-
bioRxiv - Physiology 2024Quote: ... The function of mitochondria was assessed in isolated acinar cells by measurement of oxygen consumption rate (OCR) employing a Seahorse XF Cell Mito Stress Test system (Agilent, USA). Briefly ...
-
bioRxiv - Physiology 2024Quote: ... and the mitochondria are resuspended in 1mL of Seahorse medium (Agilent #103335-100) with supplemented 10µL of 5mM pyruvate (Sigma #P2256-100G ...
-
bioRxiv - Physiology 2024Quote: ... Sample integrity was assessed prior to library preparation using the Bioanalyzer 2110 system with an RNA Nano 6000 Assay Kit (Agilent Technologies). One hundred fifty-base paired-end sequencing was performed using an Illumina NovaSeq platform according to manufacture instructions ...
-
bioRxiv - Plant Biology 2024Quote: ... and secondary antibodies α-mouse-HRP (Agilent, P0260, 1:5000), α-rat-HRP (GE HealthCare ...
-
bioRxiv - Plant Biology 2024Quote: ... RNA quality was additionally checked on a Bioanalyzer 2100 (Agilent) by the Novogene Genomics Service (Cambridge ...
-
bioRxiv - Physiology 2024Quote: ... Assay medium consisted of Sea Horse XF base medium without phenol red (Agilent Technologies, Cat#103335-100) supplemented with glucose (25 mM) ...
-
bioRxiv - Physiology 2024Quote: ... were subjected to quantitative PCR under a temperature profile of 95°C for 3 min followed by 40 cycles for 95°C for 5 sec and 58°C for 15 sec using the Stratagene Mx3000P (Agilent Technologies). For each of the samples ...
-
bioRxiv - Physiology 2024Quote: ... and extracellular acidification rate (ECAR) were measured at basal level and after addition of stressors using Seahorse XFe96 analyzer (Agilent Technologies). Assay operation software Wave version 2.6.1 was used for running the assay and obtaining data ...
-
bioRxiv - Physiology 2024Quote: ... MLO-Y4 cells with Pparγ silenced with siRNA (γY4KD) and their scrambled control (Scrl) were plated 6 hrs before the assay onto Seahorse cell culture microplates (Agilent Technologies ...
-
bioRxiv - Physiology 2024Quote: Fuel preference of CRISPR/Cas9 Pparγ edited cells (γY4KO) and mock-edited cells (C) was measured using Seahorse Mito-Fuel Flex test (Agilent Technologies), in assay medium as above and according to the manufacturer protocol ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... We performed assays in duplicate in 96-well optical plates using the MX3000P instrument (Stratagene, La Jolla, California) and Sequence Detector Software (SDS version 1.6 ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: One microliter of the sample was injected via automatic liquid sampler (Agilent 7693A) into an Agilent 7890B gas chromatograph (GC ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... Nuclei were counterstained with DAPI and the slides were mounted in fluorescent mounting medium (Dako). Images were captured using Axioimager with an M2 microscope (Carl Zeiss ...
-
bioRxiv - Synthetic Biology 2024Quote: The SrIRED gene was amplified with error-prone PCR using the GeneMorph II random mutagenesis kit (Agilent) following the instructions of the manufacturer using 2.4 µg template plasmid and 25 PCR cycles ...
-
bioRxiv - Synthetic Biology 2024Quote: ... and an Agilent 7693A autosampler fitted with a 100 μL gastight syringe was used to inject headspace gas (50 μL) into a DB-VRX capillary column (20 m, 0.18 mm ID, 1 μm film; Agilent). Data analysis was performed using Agilent MassHunter WorkStation Quantitative Analysis ...
-
bioRxiv - Synthetic Biology 2024Quote: ... or a DB-VRX capillary column (20 m, 0.18 mm ID, 1 μm film; Agilent); (ii ...
-
bioRxiv - Synthetic Biology 2024Quote: ... and an Agilent 7693A autosampler fitted with a 100 μL gastight syringe was used to inject headspace gas (50 μL) into a DB-VRX capillary column (20 m, 0.18 mm ID, 1 μm film; Agilent), and (iii ...
-
bioRxiv - Neuroscience 2024Quote: ... RNA concentration and quality (RIN > 8.0) was evaluated using an RNA 6000 Pico Kit and a 2100 Bioanalyzer system (Agilent Technologies, Santa Clara, California). RNA sequencing was performed by the NYU Genome Technology Center ...
-
bioRxiv - Plant Biology 2024Quote: ... RNA’s quality was tested using Bioanalyzer 2100 (Agilent) system ...
-
The MKK3 MAPK cascade integrates temperature and after-ripening signals to modulate seed germinationbioRxiv - Plant Biology 2024Quote: ... Signal intensities were measured by Feature Extraction Software 11.5.1.1 (Agilent) and data analysis were performed by Gene Spring (Agilent ...
-
The MKK3 MAPK cascade integrates temperature and after-ripening signals to modulate seed germinationbioRxiv - Plant Biology 2024Quote: ... the arrays were washed and scanned by Agilent DNA Microarray Scanner (G2505B ...
-
The MKK3 MAPK cascade integrates temperature and after-ripening signals to modulate seed germinationbioRxiv - Plant Biology 2024Quote: ... and data analysis were performed by Gene Spring (Agilent) and R software ...
-
bioRxiv - Plant Biology 2024Quote: ... RNA integrity was evaluated using a 2100 Bioanalyzer (Agilent Technologies, USA).
-
The MKK3 MAPK cascade integrates temperature and after-ripening signals to modulate seed germinationbioRxiv - Plant Biology 2024Quote: ... Cyanine 3-labelled cRNA was synthesized from 150 ng RNA using the Low Input Quick Amp Labeling Kit (Agilent) and predicated using RNeasy Mini Kit (QIAGEN ...
-
bioRxiv - Plant Biology 2024Quote: ... This cDNA was used as template for cRNA generation using in vitro transcription and incorporation of the dye Cy3 CTP(Agilent). Cleaning of cRNA was done using Qiagen RNeasy columns (Qiagen ...
-
bioRxiv - Plant Biology 2024Quote: ... Integrity of RNA was verified on the 2100 Bioanalyzer (Agilent, USA) using rRNA 28S/18S ratios and RNA integrity number (RIN).
-
bioRxiv - Plant Biology 2024Quote: ... against an environmental calibration standard (Agilent 5183-4688), a S (Inorganic Venture CGS1 ...