bioRxiv - Cell Biology 2020Quote: ... then transferred to brass specimen carriers and high pressure frozen with an EMPACT 2 (Leica Biosystems, Buffalo Grove, IL).
-
bioRxiv - Immunology 2021Quote: ... Semi-thin (2 μm) sections were cut with glass knifes (KnifeMaster II, LKB Bromma 7800) on an ultramicrotome (Leica Ultracut ...
-
bioRxiv - Neuroscience 2023Quote: ... and MgCl2 7) for 2 minutes and subsequently sliced in the same solution using a vibrating microtome (Leica VT1200S). Slices were allowed to recover for 1 hour at 33°C in carbongenated standard aCSF which contained (mM) ...
-
bioRxiv - Cancer Biology 2023Quote: ... The standard ACD Red Rev BOND Rx protocol was modified to include BOND Epitope Retrieval Solution 2 (Leica Biosystems) pretreatment for 25min at 95°C and to increase Amp5 step time to 30 minutes ...
-
bioRxiv - Developmental Biology 2023Quote: ... outside of the necrotic region) (Figure 8-figure supplement 1E-F) from 2 sections with the Application Suite Core v2.4 software (Leica).
-
bioRxiv - Physiology 2024Quote: ... Slides were prepared using the frozen slide delay prior to pre-treatments using Epitope Retrieval Solution 2 (Leica Biosystems) at 95 °C for 5 minutes ...
-
bioRxiv - Neuroscience 2023Quote: ... tissue was immersed in 30% sucrose for 2 days followed by embedding in Tissue-Tek OCT and sectioning of 50μm slices in a cryostat (Leica). Staining was done as described (Licht et al. ...
-
bioRxiv - Microbiology 2023Quote: ... Slides were imaged on an inverted Leica TCS SP5 confocal microscope using a 63x/1.40 oil objective with 2-3x digital zoom at calibrated magnifications and recorded with LAS AF software (Leica). Quantitation of dextran and LAMP-1 colocalization with bacteria was analyzed with CellProfiler 3.1.9 (27 ...
-
bioRxiv - Cell Biology 2022Quote: ... fluorescence images were captured every 2 s for 6 min using fluorescence microscopy (#AF6000-DMI6B; Leica Microsystems, Wetzlar, Germany) (objective lens ...
-
bioRxiv - Biochemistry 2022Quote: ... Plunging was performed at 90-100% humidity via automatic backside blotting (via Leica Microsystems Cryo GP 2 plunge freezer) or dual-side blotting (Mark IV FEI/Thermo Fisher Scientific Vitrobot) ...
-
bioRxiv - Neuroscience 2024Quote: ... Olfactory bulbs were dissected and post-fixed in 1% PFA for 2-7 days and embedded in 5% agarose and sectioned into 50µm slices using a vibratome (VT1000S, Leica). Free-floating slices were washed with PBS and incubated in 5% normal goat serum in PBS/Triton/azide (0.25% Triton ...
-
bioRxiv - Neuroscience 2024Quote: ... Brains were removed and cut into coronal slices (thickness 300 µm, -1.5 mm to 2 mm relative to bregma) on a vibratome (Leica VT1200S ...
-
bioRxiv - Cancer Biology 2024Quote: ... Antigen retrieval was performed for 20 min with Bond Epitope Retrieval Solution #2 (Leica Biosystems, equivalent EDTA, pH 9.0). Primary antibody (dilution at 1 ...
-
bioRxiv - Biochemistry 2020Quote: ... Confocal measurements were performed using a TCS SP8 STED 3× (Leica Microsystems) equipped with an HC PL APO CS2 100× objective (NA 1.4 ...
-
bioRxiv - Neuroscience 2020Quote: ... slices were mounted in 3% agarose and sliced using a vibratome (Leica VT1200S ...
-
bioRxiv - Cell Biology 2021Quote: ... Then 3-µm sections were made on a rotary microtome (RM2235, Leica). Slides were immediately stained for 1 minute in Mayer’s hematoxylin solution (Electron Microscopy Sciences) ...
-
bioRxiv - Microbiology 2021Quote: ... sections cut to 3 µm thickness using a Leica microtome (Leica, Germany) and then stained using Quick Dip Stain Kit (Modified Giemsa Stain ...
-
bioRxiv - Cell Biology 2021Quote: ... and infiltrated with wax through 3 Paraplast Plus paraffin baths (39602004; Leica). Samples were embedded in Paraplast Plus using paraffin-filled stainless steel base molds and a Thermo-Shandon Histocenter 2 Embedding Workstation (6400012D ...
-
bioRxiv - Molecular Biology 2024Quote: ... sections cut to 3 µm thickness using a Leica microtome (Leica, Germany), then samples were transferred to the Piper Hanley laboratory ...
-
bioRxiv - Plant Biology 2024Quote: ... a flat specimen carrier of 3 mm diameter (Leica Microsystems, Vienna, Austria) was first filled with a drop of 20% BSA (bovine serum albumin ...
-
bioRxiv - Neuroscience 2024Quote: ... myoinositol (3) and ascorbic acid (0.5) using a vibratome (Leica VT1200, Germany). Brains slices were transferred to an interface type holding chamber filled with 28 °C carbogen saturated ASCF containing (in mM) ...
-
bioRxiv - Neuroscience 2024Quote: ... and sectioned (3 µm) on a rotation microtome (Leica RM 2235 Germany), as previously described (Frank et al. ...
-
bioRxiv - Neuroscience 2023Quote: ... until the brains sank in the solution (1-3 days) and at which point 35um thick hypothalamic sections were obtained using a cryostat (Leica). Sections were first incubated for 1 hour in blocking buffer (1X PBS with 2% BSA and 0.1% tween-20) ...
-
bioRxiv - Plant Biology 2022Quote: ... high-light illumination of the cells was achieved by exposing the cuvette to white light set to an intensity of 620 μmol photons m-2 s-1 (Leica KL1500 LCD, peak 648 nm, FWHM 220 nm), chosen as the minimal light level necessary to saturate photosynthetic reactions and induce qE activity at the onset of illumination ...
-
bioRxiv - Biophysics 2020Quote: ... S cerevisiae (Sc) cells strain #2 after ~5h of starvation were high pressure frozen (HPM010, AbraFluid) and freeze substituted (EM-AFS2, Leica) with 0.1% uranyl acetate in acetone for 55h at −90°C ...
-
bioRxiv - Biochemistry 2022Quote: ... Neutrophils were then counted at the site of transection at 2 hours post injury (hpi) using a fluorescence dissecting stereomicroscope (Leica).
-
bioRxiv - Developmental Biology 2021Quote: ... Immunofluorescent analysis and imaging were performed on a Leica SP5X Upright 2-Photon Confocal microscope using LAS AF software (Leica) and a Leica 63X (type ...
-
bioRxiv - Plant Biology 2021Quote: ... The cross section of 2-4μm was cut with a glass knife using the ultramicrotome Leica EM UC7 (Leica Microsystems). The semi-thin sections were stained for 30mins in 0.1% aniline blue in 0.1M K3PO4 at RT ...
-
bioRxiv - Plant Biology 2021Quote: ... The stained sections were observed within 1hr to detect callose deposition using confocal laser scanning microscopy (TCS SP5 2; Leica).
-
bioRxiv - Neuroscience 2022Quote: ... brains were flash frozen in 2-methylbutane and stored at −20°C until sectioning at 40μm on a cryostat (Leica Biosystems) into cryoprotectant.
-
bioRxiv - Immunology 2022Quote: Staining for SARS-CoV-2 antigen was achieved on the Bond RX automated system with the Polymer Define Detection System (Leica) used per manufacturer’s protocol ...
-
bioRxiv - Plant Biology 2021Quote: ... 6’-diamidino-2-phenylindole (DAPI) fluorescence signals were detected by confocal laser-scanning microscopy analysis using TCS SP8 (Leica Microsystems). All the images were obtained and processed with Leica LAS AF Lite software ...
-
bioRxiv - Physiology 2021Quote: ... snap-frozen in 2-methylbutane on dry ice and sectioned into 10 μm slices using CryoJane Tape-Transfer System (Leica). Masson’s trichrome stain for cardiac fibrosis was performed according to the manufacturer’s instructions (Sigma) ...
-
bioRxiv - Neuroscience 2022Quote: ... Thin sections from the area of 2-photon imaging were cut with a diamond knife on an EM UC6 ultramicrotome (Leica), collected on pioloform-coated copper Synaptek slot grids (Electron Microscopy Sciences) ...
-
bioRxiv - Microbiology 2022Quote: ... Approximately 2 µL of the spore suspension per sample was then processed with Leica EM ICE HPF apparatus (Leica Microsystems), and then freeze substituted and embedded in Lowicryl HM20 (Electron Microscopy Sciences ...
-
bioRxiv - Plant Biology 2022Quote: ... We cut the Spurr’s blocks into semi-thin sections (0.75–2 μm) with glass knives on an ultramicrotome Leica Ultracut UCT (Leica Microsystems) stained with a solution containing 1% (w/v ...
-
bioRxiv - Cell Biology 2020Quote: ... Images were captured using Metamorph software at every 15 minutes in 37C (PeCon Tempcontrol 37-2) using confocal spinning disk system (Leica DMI 6000 B equipped with YOKOGAWA CSU-W1 Confocal Scanner Unit ...
-
bioRxiv - Neuroscience 2021Quote: ... embedded in 2% LTE agarose/ Tris-buffered saline (TBS) and cut coronally in 50 µm sections on a vibratome (VT 1000S, Leica). Sections underwent antigen retrieval in a solution of 0.1 M sodium citrate (pH 6) ...
-
bioRxiv - Developmental Biology 2021Quote: ... The tissues were then cryoprotected in 10% and 30% sucrose solutions for 2 hrs at RT and finally incubated in 30% sucrose and tissue embedding medium (Leica) (1:1 ...
-
bioRxiv - Developmental Biology 2020Quote: ... 25% laser power (Pnmy-2nmy-2::gfp) or 13% laser power (Ppie-1mCherry::phPLCδ) was used (Leica TCS SP5-II). All analyses were performed on center Z-slices of Z-stacks through the NSMnb ...
-
bioRxiv - Neuroscience 2023Quote: ... brains tissue fixed in 4% paraformaldehyde were cryoprotected in 30% sucrose for 2 hours followed by embedding in OCT for sectioning to 10μm thickness on a cryostat (Leica CM1860). Prior to staining ...
-
bioRxiv - Genetics 2023Quote: ... the worms were mounted on a 2% agarose pad and images were captured using a Leica compound microscope (Leica DM5000B).
-
bioRxiv - Immunology 2023Quote: ... as described previously.23 All heat induced epitope retrievals were performed with Bond™ Epitope Retrieval 2 (AR9640, Leica Biosystems) for 20 minutes at 95°C ...
-
bioRxiv - Neuroscience 2022Quote: ... the brain was cut into 2 mm thick coronal sections in 0.15 M cacodylate buffer using a vibratome (Leica VT1200). Then ...
-
bioRxiv - Bioengineering 2022Quote: ... a ~ 2 nm layer of gold coating was completed using a sputtering machine (Leica EM ACE 600, Buffalo Grove, IL) and was imaged using an SEM (Apreo 2 ...
-
The transcriptomic landscape of monosomy X (45,X) during early human fetal and placental developmentbioRxiv - Genetics 2024Quote: ... IHC for CSF2RA (Colony Stimulating Factor 2 Receptor Subunit Alpha) was undertaken on 3µm sections using a Leica Bond-max automated platform (Leica Biosystems). In brief ...
-
bioRxiv - Systems Biology 2024Quote: ... Dried smears were incubated in 70% ethanol for 2 hours and hematoxylin/eosin (H&E) stained using an automatic Leica Multistainer and Coverslipper (Leica ST5020+CV5030 ...
-
bioRxiv - Neuroscience 2023Quote: ... The caudal corpus callosa alongside adjacent tissue were punched with a 2 mm diameter punching tool and embedded in Epon (EM TP, Leica) prior to conventional embedding steps ...
-
bioRxiv - Neuroscience 2023Quote: ... five µm section were cut followed by a Heat-Induced Epitope Retrieval at 100°C during 20 min in BOND Epitope Retrieval 2 (ER2) solution (Leica) with 0.1 Proteinase K before Deparaffinizing ...
-
bioRxiv - Plant Biology 2023Quote: ... leaving around 2 mm of the root outside the needle which was submerged in a tissue-freezing medium (Jung, Leica) and quickly frozen in liquid nitrogen (Vogel-Mikuš et al. ...