bioRxiv - Biochemistry 2023Quote: ... 3µL of the samples were dispensed onto glow discharged Quantifoil holey carbon grids (Cu R2/1 or R2/2) using a Leica GP plunger (Leica Microsystems, Austria) maintained at 90% humidity and 10°C ...
-
bioRxiv - Biochemistry 2023Quote: 3 µl of the individual complexes were applied onto glow-discharged Quantifoil holey carbon grids (Cu R2/1 or R2/2) and vitrified in liquid ethane (−181 °C) using a Leica GP plunger (Leica Microsystems, Austria) maintained at 90% humidity and 10 °C ...
-
bioRxiv - Bioengineering 2024Quote: ... was added to the confocal dish with a 3 mm x 3 mm hole and observed under a confocal microscope (STEDYCON, Leica, Germany).
-
bioRxiv - Cell Biology 2021Quote: ... whereas samples for STEM were attached to a sticky Post-It-Note (as described in (31)) and coated with 3 nm platinum and 4 nm carbon using an ACE600 coating device (Leica Microsystems). The STEM samples were then washed with Buffered Oxide Etchant (diluted 6:1 with surfactant ...
-
bioRxiv - Cell Biology 2024Quote: ... The tissues in paraffin blocks were subjected to sectioning (3-4 μM) by rotary type of microtome (Leica RM2255 Rotary Microtome, Leica Biosystems). The tissue sections were fixed in a glass slide and stained with hematoxylin and eosin (H&E ...
-
bioRxiv - Developmental Biology 2021Quote: ... or 1:300 (rabbit anti-cleaved caspase 3, Cell Signaling Technology, 9665S; rabbit anti-p53, Leica Microsystems ...
-
bioRxiv - Plant Biology 2020Quote: ... Sections (3-4μm) cut by rotary microtome (Leica RM2265) were stained with 0.01 % aqueous toluidine blue ...
-
bioRxiv - Neuroscience 2021Quote: ... and 3% lead citrate (Leica Ultrostain II, Leica Microsystems). Images were collected semiautomatically using custom software guiding an FEI Magellan XHR 400L54.
-
bioRxiv - Neuroscience 2021Quote: ... and 3% lead citrate (Leica Ultrostain II, Leica Microsystems). Images were collected semiautomatically using custom software guiding an FEI Magellan XHR 400L54.
-
bioRxiv - Bioengineering 2023Quote: ... and 20 min in 3% lead citrate (Leica, Germany). TEM images were acquired with a 200 kV TEM JEM 2100Plus (Jeol ...
-
bioRxiv - Molecular Biology 2024Quote: ... 3 µm sections were cut on a microtome (Leica), rehydrated through an alcohol series according to standard laboratory procedures and then stained with a PAS staining kit (TCS Biosciences ...
-
bioRxiv - Cancer Biology 2023Quote: ... 3 µm sections were obtained with a microtome (Leica RM2255 Fully Automated Rotary Microtome) ...
-
bioRxiv - Microbiology 2024Quote: ... and IBA1 using the Bond- RX/3 autostainer (Leica) with the BPRD kit (DS9800 ...
-
bioRxiv - Neuroscience 2020Quote: ... Cryosections were prepared from tissue embedded in a 2:1 mixture of 30% sucrose: OCT (Sakura Finetek, catalog #4583) onto X-tra slides (Leica Microsystems, catalog #3800200). Tissue sections were dried ...
-
bioRxiv - Cancer Biology 2024Quote: ... Antigen retrieval was performed in BOND Epitope Retrieval Solution 1 (pH 6) or 2 (pH 9) (ER1, ER2, Leica Biosystems, Cat. AR9961, AR9640) at 95°C ...
-
bioRxiv - Neuroscience 2020Quote: ... Slices were prepared in oxygenated (95% O2 / 5% CO2) dissection artificial cerebrospinal fluid (ACSF) at low temperature (3-4°C) using vibroslicer (Leica, VT 1200S). After preparation slices were recovered in a resting chamber (Harvard apparatus ...
-
Genome modularization reveals overlapped gene topology is necessary for efficient viral reproductionbioRxiv - Synthetic Biology 2020Quote: ... blotting for 3-seconds at 4 °C with 90% humidity and plunging into liquid ethane using a Lecia EM GP device (Leica Microsystems, Germany). Cryo-EM data were collected on a Talos Arctica transmission electron microscope operated at 200 kV acceleration voltage using EPU automated data collection software (ThermoFisher Scientific ...
-
bioRxiv - Cancer Biology 2020Quote: ... shRalA and shRalB cells with a Nanoject microinjector 2 (Drummond) under a M205 FA stereomicroscope (Leica), using micro-forged glass capillaries (25 to 30 mm inner diameter ...
-
bioRxiv - Neuroscience 2020Quote: ... Samples were first permeabilized with heat in Bond Epitope Retrieval solution 2 (pH 9.0, Leica - AR9640) at 95°C for 2 min ...
-
bioRxiv - Cancer Biology 2020Quote: ... Heat induced antigen retrieval was performed at pH 9 (Bond Epitope Retrieval solution 2, Leica Biosystems), 100°C for 30mins ...
-
bioRxiv - Microbiology 2021Quote: ... They were then freeze substituted in a EM AFS 2 system (Leica Microsystems GmbH, Wetzlar, Germany) and embedded into Epon resin ...
-
bioRxiv - Neuroscience 2020Quote: ... (2) The SHG signal was collected from above the retina through a x40 0.8 NA (Leica) objective ...
-
bioRxiv - Cancer Biology 2020Quote: ... At least 2× step sections per lung were stained on a Bond Automated Stainer (Leica Biosystems) using standard protocol F and Target Retrieval Solution pH 6.0 (Dako ...
-
bioRxiv - Plant Biology 2020Quote: ... leaf discs were collected 2 dpi and observed using a Leica TCS SP8 (Leica, Mannheim, Germany) confocal microscope with the following excitation wavelengths ...
-
bioRxiv - Immunology 2021Quote: ... Antigen retrieval at 100 °C for 20 min with Epitope Retrieval Solution 2 (AR9640, Leica Biosystems); primary antibody incubation at 1/400 dilution for 30 min then detection using the BOND™ Polymer Refine Detection System (DS9800 ...
-
bioRxiv - Neuroscience 2020Quote: ... Brains were mounted in 2% agarose and sectioned at 50μm using a vibratome (Leica VT1000s, Germany). Coronal sections were used for all brains ...
-
bioRxiv - Cancer Biology 2024Quote: ... unstained sections were heated for 30 minutes in BondTM Epitope Retrieval Solution 2 (No. AR9640; Leica Biosystems Newcastle LTD ...
-
bioRxiv - Neuroscience 2022Quote: ... Brains were mounted in 2% agarose and sectioned at 50 μm using a vibratome (Leica VT1000s). Coronal sections were used for all brains ...
-
bioRxiv - Microbiology 2023Quote: ... antigen retrieval (20 minutes at 100°C in Leica Bond-Epitope Retrieval Solution 2 pH-9) was performed on dewaxed tissues prior to labeling with CD4 antibody (ab183685 ...
-
bioRxiv - Neuroscience 2023Quote: ... embedded in 2% agarose and sectioned to 50-μm coronal/sagittal sections by a vibratome (Leica). For OE sections ...
-
bioRxiv - Cancer Biology 2023Quote: ... FFPE tissue sections (2 μm thickness) obtained with a Leica RM2245 rotary micro-tome (Leica Biosystems) were mounted on glass slides (Superfrost Plus ...
-
bioRxiv - Cancer Biology 2022Quote: ... Antigen was unmasked with Tris-EDTA pH 9 (Bond Epitop Retrival Solution 2 Leica, cat# AR9640). Both mouse monoclonal anti-Ki67 CloneMIB-1 (Dako ...
-
bioRxiv - Plant Biology 2024Quote: ... The equatorial sections of BY-2 cells estradiol induced 5-d-old BY-2 cells expressing XVE:CbPINa:GFP or XVE:CbPINc:GFP were acquired by Leica SP8 confocal microscope (HC PL APO CS2 63×/1.2 W objective ...
-
bioRxiv - Molecular Biology 2020Quote: ... 4 μl of this mixture was back side blotted for 6 s at relative humidity 98% and temperature 19°C on a glow-discharged holey carbon grid (CF-2/1-3C, Protochips) before plunge-freezing in liquid ethane (Leica EM GP2 automatic plunger). Dose-symmetrical tilt series acquisition 51 was performed on an FEI Titan Krios electron microscope operated at 300 kV using a Gatan Quantum energy filter with a slit width of 20 eV and a K2 or K3 direct detector operated in counting mode ...
-
bioRxiv - Cancer Biology 2021Quote: ... Agilent M087601-2, used at a dilution of 1/50 for 15mins at room temperature. HIER was performed on-board using Leica ER1 solution (low pH) for 20 minutes ...
-
bioRxiv - Microbiology 2020Quote: ... 2.3% methanol and 1–3% H2O in Acetone) tempered at −90°C in FS device (Leica AFS2) equipped with a robotic solution handler (Leica FSP) ...
-
bioRxiv - Plant Biology 2022Quote: ... 1 cm root segments were embedded in 3% agarose and sectioned using a vibratome (Leica VT1000 S) to produce 150-200 μM thickness sections ...
-
bioRxiv - Developmental Biology 2020Quote: Imaging of embryos and tissues was performed using a Leica MZ 16F dissecting microscope equipped with a Leica DFC420 C digital camera supported by the Leica Application Suite software package (LAS, version 3 or 4; Leica Microsystems, Germany/Switzerland), and Leica EL6000 fluorescence light source.
-
bioRxiv - Cell Biology 2020Quote: ... The frozen samples were subsequently transferred into a Leica EM AFS-2 freeze substitution unit (Leica Microsystems). Over a period of five days ...
-
bioRxiv - Evolutionary Biology 2021Quote: ... 0.05% uranyl acetate in acetone and placed into an AFS-2 Freeze Substitution Machine (Leica Microsystems, Austria). Samples were freeze-substituted at −90°C for 72 h ...
-
bioRxiv - Physiology 2021Quote: ... CFP and DsRed fluorescence signal were detected after 2 days with a CLSM (Leica AF6000 modular microsystems). All experiments were biologically repeated for three times.
-
bioRxiv - Neuroscience 2021Quote: ... or inferior colliculus were cut at 300 µm with a vibratome (VT1200S, Leica, or 7000smz-2, Campden) in warm aCSF ...
-
bioRxiv - Plant Biology 2021Quote: ... the embedded samples were sectioned at 2–5 μm thickness using a rotary microtome (Leica, Wetzlar, Germany) and stained with basic fuchsin ...
-
bioRxiv - Neuroscience 2020Quote: ... Antigen retrieval was done by incubation with Bond Epitope Retrieval solution 2 (AR9640, Leica Biosystems, Wetzler, Germany) for 20 minutes and then sections were then washed with Bond Wash solution 3x ...
-
bioRxiv - Cell Biology 2020Quote: ... 0.5 % glutaraldehyde and 0.25 % uranyl acetate for 60 h in a FS system (AFS-2, Leica Microsystems). Larvae were embedded in an Epon-Araldite mix (hard formula ...
-
bioRxiv - Cell Biology 2023Quote: ... images were captured every 2 h for 72 h by the IncuCyte Live-Cell analysis system (Leica).
-
bioRxiv - Developmental Biology 2023Quote: ... 0.5% glutaraldehyde and 0.25% uranyl acetate for 60 h in a FS system (AFS-2, Leica Microsystems). Larvae were embedded in Epon-Araldite mix (EMS hard formula) ...
-
bioRxiv - Immunology 2022Quote: ... Paraffin embedded kidney sections (2 µm) were cut on a Leica RM 2165 microtome (Leica, Wetzlar, Germany) and dried at 60°C for 1 h ...
-
bioRxiv - Cancer Biology 2023Quote: ... Antigen was unmasked with Tris-EDTA pH 9 (Bond Epitope Retrieval Solution 2, Leica Biosystems, cat# AR9640).
-
bioRxiv - Bioengineering 2022Quote: ... and counted for expression of opie-2-dsRed and 3xP3-tdTomato using a fluorescent stereoscope (Leica M165FC). The difference in total larval counts compared to total egg counts were considered to be dead during embryonic or early larval stages ...