Labshake search
Citations for Beckman :
401 - 450 of 2114 citations for 3 Hydrazino 5 methyl 4H 1 2 4 triazol 4 ylamine hydrochloride since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2022Quote: ... Gradients were ultracentrifuged at 192,000xg for 16 - 18 hours at 4°C (Beckman Coulter Optima XPN-80 with a SW40Ti rotor) ...
-
bioRxiv - Neuroscience 2023Quote: ... each pool of 4 unique samples was transferred to an ultracentrifuge tube (Beckman Coulter Polypropylene Centrifuge Tubes ⅝ x 3 ¾ in. ...
-
bioRxiv - Microbiology 2024Quote: ... The cell volume was analysed with a Multisizer 4 Coulter Counter (Beckman-Coulter). Runs were completed in the volumetric mode (100 μL) ...
-
bioRxiv - Biochemistry 2024Quote: ... at 4°C for 128 min using a SW 40Ti rotor (Beckman Coulter). After centrifugation ...
-
bioRxiv - Cell Biology 2023Quote: ... Flow cytometric analyses were performed on a BD Fortessa 4-Laser Analyzer (Beckman Coulter ...
-
bioRxiv - Biochemistry 2023Quote: ... 4 °C in a Allegra X-15R centrifuge (Swinging bucket rotor, Beckman Coulter). The cell pellet was resuspended in 10 ml 20 mM Tris pH 7.5 and passed once through a French press at 120 MPa ...
-
bioRxiv - Systems Biology 2023Quote: ... the supernatant was then divided into 4 x 1.5 mL Ultracentrifuge Tubes (Beckman) and processed for differential ultracentrifugation step with an Optima TLX-BenchTop Ultracentrifuge (Beckman ...
-
bioRxiv - Plant Biology 2023Quote: ... total cellular volume was measured using a Multisizer 4 Coulter counter (Beckman Coulter) and the different strains were diluted to reach a similar cellular concentration before N deficiency experiments.
-
bioRxiv - Microbiology 2024Quote: ... Cell concentration was measured using Multisizer 4 COULTER COUNTER (Beckman Coulter, Indianapolis, USA), except for P ...
-
bioRxiv - Biochemistry 2024Quote: ... centrifuged at 100,000 × g at 4 °C for 18h (SW28 rotor, Beckman Coulter), and fractionated using Brandel gradient fractionator ...
-
bioRxiv - Biophysics 2020Quote: ... The lysates were clarified by centrifugation (16,000 rpm for 1 h at 4°C, rotor JA 25.50, Beckman Coulter, Brea, California, USA). The supernatant was incubated with amylose resin for 1 h at 4°C and loaded onto a 20 ml chromatography column (Bio-Rad ...
-
bioRxiv - Systems Biology 2020Quote: ... Next the cultures were diluted 1:40 with 0.5M NaCl and immediately measured in Multisizer™4 COULTER COUNTER® (Beckman Coulter) (Coulter ...
-
bioRxiv - Plant Biology 2020Quote: ... Double size selection was carried out by adding 50 μL of a 1:4 (0.5X) mixture of AMPure XP Beads (Beckman Coulter, Brea, USA) to PEG buffer (20% PEG w/v ...
-
bioRxiv - Molecular Biology 2023Quote: ... The cell lysate was centrifuged at 4 °C at 35000 rpm for 1 hour with Beckman Optima™ L-80XP Ultracentrifuge equipped with Ti45 rotor (Beckman, USA). The pellet containing membranes and cell debris was discarded ...
-
bioRxiv - Neuroscience 2022Quote: ... The loaded gradient was ultracentrifuged at 69,150 x g for 1 h at 4 °C (SW 41 Ti Swinging-Bucket Rotor, Beckman Coulter, Cat. #331362) and the synaptosome fraction was harvested from the interface between the two sucrose layers ...
-
bioRxiv - Cell Biology 2023Quote: ... the supernatants were transferred into SW60 tubes (in vivo studies 1–4) or SW40 tubes (donated patients) (Beckman Coulter Inc., Brea, USA) and centrifuged at 10,000xg for 35 minutes ...
-
bioRxiv - Neuroscience 2024Quote: ... The supernatant was segregated subsequent to centrifuging the brain tissue homogenate for 1 h at 100,000g and 4°C utilising an ultra-high-speed centrifuge (Beckman, Optima MAX-XP). The tissue residue was then reprocessed ...
-
bioRxiv - Microbiology 2024Quote: ... The top agar was then scraped off the LB agar and centrifuged for 26,000 x g at 4°C for 1 hour (Beckman Coulter JA-17). The supernatant was then removed ...
-
bioRxiv - Microbiology 2024Quote: ... Crude ribosomes were separated from other low molecular weight cellular contents by centrifugation at 35000 rpm (126,000g) for 1 hour at 4 °C (Beckman rotor Type 70Ti). The crude ribosome pellet was resuspended in 10 mL HMA-10 buffer and layered on top of a 10 mL 32% sucrose solution in HMA-10 buffer and centrifuged for 16 hours at 37,000 rpm (140,000g ...
-
bioRxiv - Neuroscience 2024Quote: ... The PNS- Nycodenz gradient was centrifuged for 1 h at 141,000 x g at 4°C (46,000 rpm, TLS-55 rotor, Beckman Coulter Optima TLX Ultracentrifuge). After centrifugation ...
-
bioRxiv - Biochemistry 2020Quote: ... The sample was centrifuged at 4°C for 1 hour and 40 minutes at 182,753 x g (38,000 rpm in a Beckman Coulter Type 42.2 Ti rotor).
-
bioRxiv - Molecular Biology 2021Quote: ... 1 mM ATP and 1 mM PMSF) and centrifuged for 15 h at 4°C and 74 400 x g (Beckman SW 32.1 Ti). From the gradient ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... the cell lysate was layered on top of a discontinuous OptiPrep® gradient (50 %, 35 %, 30 %, 20 %, and 15 %) and centrifuged at 135,000 g for 1 h at 4°C (Beckman L8-80M Ultracentrifuge, USA). The melanin pellet was recovered ...
-
bioRxiv - Microbiology 2024Quote: ... The 1 ml fraction containing the phage was then placed on a 40% (w/v) - 60% (w/v) sucrose gradient for 1 hour at 63,400 x g at 4°C (Beckman Coulter SW 40 Ti). The 1 ml fraction was then placed in a 50 kDa dialysis membrane (Spectrum Labs ...
-
bioRxiv - Biochemistry 2024Quote: ... The A2aR-expressing membrane fraction was obtained by ultra- centrifugation at 100,000 g for 1 hour at 4°C in a Type 70 Ti Fixed-angle rotor (Optima XPN ultracentrifuge, Beckman Coulter Life Sciences). The pellet (membrane fraction ...
-
bioRxiv - Microbiology 2020Quote: ... pH 7.4) and centrifuged at 182,000g for 1.5 h at 4°C (Beckman SW40). Then the lipid droplets on the top were collected and washed for further analysis.
-
bioRxiv - Systems Biology 2020Quote: ... pelleted at 3,709 xg for 4 min (Allegra X-30R, C0650 adaptor, Beckman Coulter), and resuspended in 50 mL of ice-cold deionized water (MilliQ Biocel A10 ...
-
bioRxiv - Cell Biology 2021Quote: ... at 4°C using the SW 55 Ti Swinging Bucket rotor (Beckman Coulter, 342194).
-
bioRxiv - Molecular Biology 2022Quote: ... After centrifugation at 6000 g for 15 min at 4 °C (JA14 rotor-Beckman), the cell pellet is resuspended with cold lysis buffer (1mg/ml lysozyme ...
-
bioRxiv - Cell Biology 2021Quote: ... After centrifugation (55,000 rpm, 80 min, 4°C) in a TLS55 rotor (Beckman Coulter), fractions were collected manually for precipitation with trichloroacetic acid (TCA ...
-
bioRxiv - Cell Biology 2021Quote: ... After centrifugation (38,000 rpm, 210 min, 4°C) in an SW41 rotor (Beckman Coulter), RNA content was measured at A254 while fractions were collected using a Foxy Jr ...
-
bioRxiv - Biochemistry 2020Quote: ... and spun at 90,000 rpm for 10 min at 4°C (TLA120.1 Beckman Coulter). After incubation at 37°C for 2 mins ...
-
bioRxiv - Cell Biology 2022Quote: ... and centrifuged at 4°C for 30min at 5,000xg and subsequently at 10,000xg (Beckman Coulter Optima XPN-80 with a SW60 rotor) ...
-
bioRxiv - Neuroscience 2024Quote: ... for 20 min at 4°C using the pre-cooled 70.1 rotor (Beckman, 342184). Pellets were kept on ice ...
-
bioRxiv - Cell Biology 2024Quote: ... and 10,000 g (30 min, 4 °C, SW28 rotor; Optima XPN Ultracentrifuge, Beckman Coulter) to pellet large EVs52 ...
-
bioRxiv - Cancer Biology 2024Quote: ... 10,000 × g for 30 min) at 4°C (Beckman Coulter Avanti J-E Centrifuge); filtered through a 0.22 μm PES filter (Genesee) ...
-
bioRxiv - Microbiology 2022Quote: ... The gradient was centrifuged at 100,000 × g for 18 h at 4°C (Beckman-Coulter XPN-80 Ultracentrifuge ...
-
bioRxiv - Biochemistry 2024Quote: ... and cleared by centrifugation at 4°C (18500 rpm, JA-25.50 Beckman, 20 min,). The clarified extract was purified on a 4 ml His60 Ni-IDA Superflow resin (Ozyme ...
-
bioRxiv - Biophysics 2024Quote: Cells were harvested (Beckman F10 BCL, 20 min at 6000 rpm and 4 °C), resuspend in PBS pH 7.4 ...
-
bioRxiv - Systems Biology 2020Quote: ... and the resultant supernatant was ultracentrifuged at 100,000xg for 40 minutes at 4°C (rotor TLA 120.2; Beckman Coulter 343778 1 ml uncapped tubes).
-
bioRxiv - Physiology 2021Quote: ... sEV were further isolated from lEV-depleted supernatants following a 100,000 xg ultracentrifugation step for 1 hour at 4°C (rotor MLA-50, Beckman Coulter Optima MAX-XP Ultracentrifuge) and two washes in NaCl before resuspension in NaCl.
-
bioRxiv - Biophysics 2023Quote: ... Cell debris was removed by centrifugation at 20,000 rpm at 4°C for 1 h (Avanti® J-E centrifuge from Beckman Coulter, rotor: JLA 25.50). The supernatant was collected and loaded onto a pre-equilibrated 5 ml His-Trap FF crude column ...
-
bioRxiv - Cell Biology 2020Quote: ... and ultracentrifuged with a 70 Ti rotor (Beckman Coulter; 50,000 rpm, 75 min, 4°C). Supernatants after ultracentrifugation were mixed with COSMOGEL GST-Accept beads (Nacalai Tesque ...
-
bioRxiv - Molecular Biology 2021Quote: ... at 40000 rpm for 30 min at 4°C with a Ti45 rotor (Beckman, USA). Mpro-containing supernatant was applied to an immobilized metal affinity chromatography (IMAC ...
-
bioRxiv - Neuroscience 2021Quote: ... S1 was centrifuged at 30,000 rpm for 30 min at 4°C (Beckman S4180 rotor). The obtained pellet (P2 ...
-
bioRxiv - Molecular Biology 2020Quote: ... and 4 mM magnesium acetate) were prepared in 25 × 89 mm polyallomer tubes (Beckman Coulter) using a Gradient Master (BioComp) ...
-
bioRxiv - Biochemistry 2020Quote: ... the filtered cell culture fluid was ultracentrifuged (25k rpm, 4 °C, SW55Ti Rotor, Beckman Coulter) through a 20% sucrose cushion prepared in TNE buffer (10 mM Tris-HCl ...
-
bioRxiv - Biochemistry 2021Quote: ... and concentrated by ultracentrifugation (100,000 × g, 90 min 4 °C, SW41, Beckman Coulter, Brea, CA). The pellet was resuspended in reducing Laemmli SDS-PAGE sample buffer ...
-
bioRxiv - Biophysics 2021Quote: ... Cell debris was removed by centrifugation (Beckman Avanti, 45 min, 40,000 x g, 4 °C) and supernatants were diluted 3-fold in 20 mM Tris pH 8.0 ...
-
bioRxiv - Neuroscience 2020Quote: Particle size distribution was determined using a Coulter Multisizer 4 (Beckman Coulter, Inc., Miami, FL). Particles were resuspended in double distilled water and added dropwise to 100 ml of ISOTON II solution until the coincidence of the particles was between 8% and 10% ...