Labshake search
Citations for Beckman :
351 - 400 of 1117 citations for Sulfur Free Cobalt Metallo Organic Standard Co @ 5000 µg g in Hydrocarbon Oil since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2023Quote: ... Opti-MEM supplemented with 20% BGS and penicillin/streptomycin was centrifuged at 110,000 × g (SW28 rotor, Beckman) for 20 hours at 4 °C in an ultracentrifuge (LE-80K ...
-
bioRxiv - Cell Biology 2023Quote: ... Ribosomes/polysomes were centrifuged at 247,600 g (38,000 rpm) in a SW41 Ti rotor (Beckman Coulter, #331362) for 3 h 30 min at 4 °C ...
-
bioRxiv - Cell Biology 2024Quote: ... 086 x g for 2.5 hours at 4°C using Optima L-100 XP ultracentrifuge (Beckman Coulter), and the pellet was resuspended in LHCN medium ...
-
bioRxiv - Cell Biology 2024Quote: ... The tubes were then centrifuged at 200,000 g for 1 h at 22 °C (TL 100, Beckman). After ultracentrifugation ...
-
bioRxiv - Cancer Biology 2024Quote: ... centrifuged twice at 100,000 × g for 2 h at 4°C (Beckman Coulter Optima XE-90 Ultracentrifuge). The supernatant was replaced with DPBS between ultracentrifugation spins ...
-
bioRxiv - Molecular Biology 2022Quote: ... 6 mM β-mercaptoethanol) and spun at 43,000 rpm (214,000 × g) in a Type 45Ti rotor (Beckman) for 19 hours at 4°C ...
-
bioRxiv - Molecular Biology 2022Quote: ... then clarified by centrifugation at 66,000 x g for 30 min using a JA 25.50 rotor (Beckman). The clarified lysate was incubated with 2 mL of pre-equilibrated Protein C affinity resin (Roche ...
-
bioRxiv - Cell Biology 2022Quote: ... The supernatant was ultracentrifuged for 2 h at 150,000 x g in an Optima XP centrifuge (Beckman) with a MLA-50 rotor ...
-
bioRxiv - Microbiology 2022Quote: The crude lysate of Bl 1821L harbouring the putative antibacterial proteins after mitomycin C induction was purified by ultracentrifugation of 7.5 ml of CFS at 35,000 rpm (151,263 x g) in a swing bucket rotor (41Ti, Beckman) for 70 min ...
-
bioRxiv - Biophysics 2023Quote: ... The insoluble cell debris was removed by ultracentrifugation (Beckman Ti70 rotor, 150,000 x g for 1 h), and the supernatant was incubated with 2ml Strep-Tactin resin (#2−1201-025 ...
-
bioRxiv - Biophysics 2023Quote: ... The cells were centrifuged at 2095 × g (centrifuge Allegra X-15R by Beckman, swing-out rotor SX4750A) at 4°C for 10 min and the growth medium was exchanged for PBS buffer ...
-
bioRxiv - Biochemistry 2023Quote: ... then clarified by centrifugation at 66,000 x g for 30 min using a JA 25.50 rotor (Beckman). The supernatant was incubated with 2 mL of pre-equilibrated Protein C affinity resin (Roche ...
-
bioRxiv - Physiology 2023Quote: ... and for 16 h at 175,000 × g (pellets represent the smaller particle fraction; TLA100 rotor Beckman-Coulter)20 ...
-
bioRxiv - Molecular Biology 2023Quote: ... at 10,000 g for 30 min (JXN-30 with JS-24.38 rotor and tube 364772, Beckman Coulter), and at 100,000 g for 110 min (JXN-30 with JS-24.38 ...
-
bioRxiv - Biochemistry 2023Quote: ... After ultracentrifugation for 1h at 258,488 x g at 4°C using a TLS-55 rotor (Beckman), the fractions were analysed by SDS-PAGE and the positive fractions were concentrated ...
-
bioRxiv - Pathology 2024Quote: ... The lysate was clarified by centrifugation at 25,000× g for 1 h using rotor JA25.5 (Beckman Coulter). The supernatant was purified by an FPLC AKTAxpress system (GE Healthcare ...
-
bioRxiv - Cell Biology 2024Quote: ... +/- 20 mM EDTA) and centrifuged for 60 minutes at 100,000 g in a TLA55 rotor (Beckman-Coulter) at 4°C ...
-
bioRxiv - Biophysics 2024Quote: ... Aggregates were removed by ultracentrifugation at 4 °C at 100,111 x g in a TLA100 rotor (Beckman). Fresh Halo-fluorophore conjugated proteins were prepared for each experiment.
-
bioRxiv - Biophysics 2024Quote: ... and then centrifuged at 250,000 g for 7 min at 37 °C in a TLA100 rotor (Beckman). The pellet was then resuspended in a bright tubulin mix containing 7.5 mM unlabeled tubulin ...
-
bioRxiv - Biophysics 2024Quote: ... lysed via sonication and centrifuged at 27,200 g for 30 min using a JA-20 (Beckman Coulter). Soluble protein in the supernatant was purified by Talon metal affinity resin (Takara Bio ...
-
bioRxiv - Biochemistry 2024Quote: ... mucins were purified by density gradient ultracentrifugation at 417,600 g at 15 °C for 72 h (Beckman Coulter LE80 K ultracentrifuge ...
-
bioRxiv - Microbiology 2024Quote: ... The supernatant was then spun at 100,000 x g for 1 hour (Beckman Coulter Type 45 Ti) and resuspended in P buffer (10 mM potassium phosphate ...
-
bioRxiv - Microbiology 2024Quote: ... The final supernatant was ultracentrifuged at 104,000 × g using an Optima XE-90 Ultracentrifuge (Beckman Coulter Inc.) to pellet the viral particles ...
-
bioRxiv - Biochemistry 2024Quote: ... samples were ultracentrifuged at 100,000 g for 5 minutes at 25°C (Beckman TL100, rotor TL-A100). Supernatants were recovered and the hexapeptide concentrations of were determined by UV absorption as previously described ...
-
bioRxiv - Synthetic Biology 2024Quote: ... and centrifuged at around 100,000 g for 15 min at room temperature using an Airfuge (Beckman Coulter). After centrifugation ...
-
bioRxiv - Cell Biology 2024Quote: ... The lysate was cleared by centrifugation (1 hour, 50,000 × g) in a JA 25.50 rotor (Beckman Coulter), filtered and loaded onto a 5-mL HisTrap FF column (Cytiva) ...
-
bioRxiv - Synthetic Biology 2024Quote: ... A 2 µg/µL BSA solution (in water) was transferred from a 384-well polypropylene 2.0 Plus Source microplate (Beckman) using the 384PP_Plus_BP fluid type into a 384-well destination plate (BioRad ...
-
bioRxiv - Cell Biology 2024Quote: ... cDNA amplification reaction was supplemented with the HTO additive primer and followed by a cDNA clean-up separating the HTO fraction from the cell cDNA using standard methodologies (Beckman Coulter, AMPure XP, cat. A63880). All size selected fractions (cell cDNA and HTO cDNA ...
-
bioRxiv - Cell Biology 2021Quote: ... The supernatant was centrifuged at ∼100,000×g (28,000 RPM) for 1.5 h using two SW-28 rotors (Beckman Coulter). The pellet was resuspended with 200 µl phosphate buffered saline (PBS) ...
-
bioRxiv - Cell Biology 2020Quote: ... and then centrifuged (300 g for 5 min at 4 °C) (Allegra X-30R Centrifuge, Beckman Coulter, USA) to obtain the myofiber-associated cell pellet ...
-
bioRxiv - Cell Biology 2020Quote: ... and finally for 90 min at 100,000 × g (30,000 rpm = 100K) in a P55ST2-639 rotor with an Avanti JXN-26 (Beckman) centrifuge to collect EV pellet ...
-
bioRxiv - Cell Biology 2020Quote: ... and then centrifuged (300 g for 5 min. at 4 °C) (Allegra X-30R Centrifuge, Beckman Coulter, USA) to obtain the myofiber-associated cell pellet ...
-
bioRxiv - Immunology 2021Quote: ... Supernatant was again taken and centrifuged at 10,000 x g for 45 minutes in an ultracentrifuge (Beckman Coulter) to remove larger/denser EVs ...
-
Rhes protein transits from neuron to neuron and facilitates mutant huntingtin spreading in the brainbioRxiv - Neuroscience 2021Quote: ... The gradient was spun for 3 h at 180,000 × g (average) at 4°C (SW41 Beckman ultra-centrifuge). After the spin the top of the gradient was removed and discarded ...
-
bioRxiv - Molecular Biology 2021Quote: ... RNA concentration of the cleared lysate was measured by nanodrop and 500 μg of this RNA was loaded onto the gradient and run for 2.5 hr at 220,000 g and 4°C in an SW41-rotor (Beckman). Gradients were then run at 850 μL/min in a density gradient fractionation system (Teledyne Isco) ...
-
bioRxiv - Microbiology 2021Quote: ... the supernatant was ultracentrifuged at 100k × g for 1.5 h using an SW28 rotor (Beckman Coulter, Brea, CA) at 4°C ...
-
bioRxiv - Cell Biology 2020Quote: ... supernatants were combined together and centrifuged at 100,000 g for 1 hour in a Ti70 rotor (Beckman Coulter). Membrane pellet was resuspended in a solubilization buffer (50 mM HEPES pH=8.0 ...
-
bioRxiv - Cell Biology 2021Quote: ... The resulting supernatant was then centrifuged at 100,000 x g for 90 minutes using the 70Ti rotor (Beckman). The pellet was washed with PBS followed by another centrifugation at 100,000 × g for 90 minutes ...
-
bioRxiv - Bioengineering 2021Quote: ... The resulting solution was centrifuged at 164,000 × g (30,000 rpm) for 4 h at 20°C (Optima XPN-80 Ultracentrifuge, Beckman) to remove any remaining nanotube aggregates.
-
bioRxiv - Biochemistry 2020Quote: ... The membrane extract was clarified by spinning at 10,000 g for 30 minutes (Beckman Coulter JA-20 rotor). The supernatant was diluted 3 times with NiNTA A buffer (20 mM HEPES pH 7.7 ...
-
bioRxiv - Biophysics 2021Quote: ... The gradient was centrifuged at 436,000 g for 180 min in a TLA 120.2 rotor (Beckman Coulter, USA). After centrifugation ...
-
bioRxiv - Neuroscience 2020Quote: ... 5 mM HEPES (pH 7.4)] and centrifuged for 18 hrs at 100,000 x g (SW 32.1 Ti; Beckman Coulter) with no brake ...
-
bioRxiv - Biochemistry 2020Quote: ... Beckman CoulterTM at 150.000 g for 120 minutes at 4°C with a TLA-55 Rotor (Beckman CoulterTM) to pellet EVs ...
-
bioRxiv - Microbiology 2020Quote: ... The plasma density was adjusted to 1.25 g/ml using potassium bromide (KBr) and centrifuged at 49,000 rpm (NVTi 65; Beckman) for 16 hours at 10°C ...
-
bioRxiv - Biochemistry 2021Quote: ... and separated by ultracentrifugation in a TLA120.2 rotor (Beckman Coulter; 1.5 h at 278,000 x g, 4°C).
-
bioRxiv - Biophysics 2020Quote: ... and then sonicated and ultracentrifuged (440,000 g, 35 min, 4°C; MLA80 rotor, Beckman Optima™ MAX-TL). The supernatant was applied to a Ni-NTA column (Machery-Nagel ...
-
bioRxiv - Biophysics 2020Quote: ... 50 μM PF846) and centrifuged for 1 hour at 603,000 g using a MLA-130 rotor (Beckman Coulter) at 4 °C ...
-
bioRxiv - Cell Biology 2020Quote: ... pellets obtained by ultracentrifugation (100,000 x g in Ti45 Beckman Coulter rotor for 70 min. at 4 ° C) were washed and resuspended in 1.25 ml buffer [0.25 M sucrose ...
-
bioRxiv - Microbiology 2022Quote: ... Vesicles were collected by ultra-centrifugation at 80,000 x g (Ti 45 rotor; Beckman Instruments, Inc., Fullerton, CA) at 4°C for 1.5-2h followed by 180,000 x g (Ti 70i rotor ...
-
bioRxiv - Microbiology 2022Quote: Samples of pooled sucrose gradient fractions of IMD and PM-CW were pelleted at 100,000x g for 60 min on TLA100.2 rotor (Beckman), and washed with HES buffer (25mM HEPES-HCl ...