Labshake search
Citations for Beckman :
1151 - 1200 of 1773 citations for 7 Chloro 5 methyl 1H pyrrolo 2 3 c pyridine since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2024Quote: ... The homogenate was centrifuged (45 min, 16 000 rpm, 4°C, JLA 16.250 rotor, Beckman-Coulter Centrifuge Avanti J25-01) and the supernatant subjected to Ni-NTA affinity purification (HIS-Select Nickel Affinity Gel (Sigma Aldrich)) ...
-
bioRxiv - Neuroscience 2024Quote: ... The supernatant was ultracentrifuged at 80,000 × g for 1 h at 4°C using a type 50 Ti rotor ultracentrifuge (Beckman Coulter). The supernatant ...
-
bioRxiv - Cell Biology 2023Quote: ... the fifth virus was freeze-thawed three times and ultracentrifuged at 23 k rpm at 4 °C for 1.5 hours in the Super-centrifuge Optima XE-90 Ultracentrifuge (Beckman Coulter) using Ultra-Clear Centrifuge Tubes (Beckman Coulter) ...
-
bioRxiv - Biochemistry 2023Quote: ... The gradient was centrifuged for 2.30 hours at 4 °C and 111,000 ×g in a swing-out rotor (Beckman- Coulter, SW41). The brownish lysosome-enriched fraction (∼ 1ml ...
-
bioRxiv - Cell Biology 2023Quote: ... Small EVs were isolated by ultracentrifugation at 120,000 x g and 4°C for 120 min using Optima XE-90 equipment with a SW32Ti rotor (Beckman Coulter). Supernatants were discarded using a pipette ...
-
Centriole and transition zone structures in photoreceptor cilia revealed by cryo-electron tomographybioRxiv - Cell Biology 2023Quote: ... OptiPrep step-gradient and centrifuged for 60 min at 19,210 × g at 4 °C in a TLS-55 rotor (Beckman Coulter). The ROS band was collected with an 18G needle ...
-
bioRxiv - Microbiology 2023Quote: ... After ON growth at 37° C with shaking strain frequencies were measured using flow cytometry (Beckman Coulter CytoFLEX flow cytometer). Relative fitness was calculated as the ratio of relative frequency of the strains at the end of the experiment to their initial frequency.
-
bioRxiv - Systems Biology 2023Quote: ... Gradients were centrifuged at 4°C for 17 h at 100,000 g using an L7 ultracentrifuge with an SW28 swing out rotor (Beckman Coulter). Fractions (F ...
-
bioRxiv - Microbiology 2022Quote: ... The eluted sample was collected by centrifugation at 2000 rpm for 1 minute 4 °C in a F241.5P rotor using a 149 Microfuge 22R centrifuge (Beckman Coulter). For SDS-PAGE analyses ...
-
bioRxiv - Cell Biology 2022Quote: ... 4–40% sucrose gradient prepared in lysis buffer and centrifuged at 150,000 × g for 4 or 16 h at 4°C in a MLS-50 rotor (Beckman Coulter). Thereafter ...
-
bioRxiv - Cell Biology 2023Quote: ... The iodixanol density gradients were centrifuged at 100,000 x g at 4◦C for 18 hours in SW41Ti rotor (Beckman Coulter). Ten fractions (F1 ...
-
bioRxiv - Molecular Biology 2023Quote: ... and ultracentrifuged in a sucrose cushion at 100,000 rpm at 4°C for 1 h with a TLA110 rotor (Beckman Coulter). The ribosome pellet was dissolved in TRIzol reagent (Thermo Fisher Scientific) ...
-
bioRxiv - Cell Biology 2023Quote: ... Lysates were cleared by centrifugation at 25 000 rpm for 45 min at 4°C in a Ti45 rotor (Beckman). Supernatant was incubated with 5 ml of Glutathione Sepharose 4B beads slurry (Cytiva ...
-
bioRxiv - Neuroscience 2022Quote: ... The homogenised mixture then underwent ultracentrifugation at 200,000 g for 110 min at 4°C with a SW-41 Ti rotor (Beckman Coulter) and transferred the supernatant into a Slide-A-Lyzer™ G2 Dialysis Cassettes 2K MWCO (Thermo ...
-
bioRxiv - Cancer Biology 2022Quote: ... Fractions 2–9 were diluted 1:10 in PBS and centrifuged at 20,000 ×g (bEVs) or 100,000 ×g (sEVs) at 4°C for 1 h with an MLS-55 rotor (Beckman Coulter). The bEV and sEV pellets were suspended in double 0.22-µm-filtered PBS and were either used directly for experiments or stored in aliquots at −80°C until subsequent BLI ...
-
bioRxiv - Cancer Biology 2023Quote: ... clarified by centrifugation at 20,000 rpm (48,385 x g) for 30 min in a JA25.50 rotor at 4 °C (Beckman AvantiTM J-25), filtered through a 0.8/0.2 AcroPak Filter Unit (Pall) ...
-
bioRxiv - Biophysics 2023Quote: ... Reactions were centrifuged at 400,000 g at 20 °C for 15 min in polycarbonate centrifuge tubes (Beckman Coulter Inc. USA). The pellets were resuspended in 40 μl reaction buffer ...
-
bioRxiv - Genomics 2023Quote: ... the supernatant was cleared by two rounds of centrifugation at 20,000 ×g (10 min, 4 °C, JA-20 rotor, Avanti J-26 XP, Beckman Coulter) followed by centrifugation at 31,900 ×g (10 min ...
-
bioRxiv - Genomics 2023Quote: ... Precipitated ribosomes were pelleted at 20,000 ×g (10 min, 4 °C, JA-20 rotor, Avanti J-26 XP, Beckman Coulter). To remove residual supernatant the pellet was re-centrifuged for 5 min at 20,000 ×g ...
-
bioRxiv - Cell Biology 2023Quote: ... then incubated for 1 hr at RT before centrifugation at 100,000 x g (23°C) in a TLA100 rotor (Beckman-Coulter). The top 50% of the supernatant was removed ...
-
bioRxiv - Molecular Biology 2023Quote: ... then pelleted at 4°C and 4,300 x g for 30 min in an Allegra X-14R centrifuge (Beckman Coulter) equipped with a swinging bucket SX4750 rotor ...
-
bioRxiv - Plant Biology 2023Quote: ... The cAW was collected by spinning at 700 x g for 20 min at 4 ⁰C (JA-14 rotor, Beckman Coulter ...
-
bioRxiv - Genomics 2023Quote: ... The ribosomes were further purified by centrifugation at 59,727 ×g (15 hours, 4 °C, SW 32.1 Ti rotor, Optima™ L-100 XP, Beckman Coulter) in a linear (15 – 30 % ...
-
bioRxiv - Biochemistry 2023Quote: ... Insoluble material and cellular debris were removed by ultracentrifugation at 40,000 RPM for 45 minutes at 4°C using a Ti45 fixed-angle rotor (Beckman-Coulter). The resulting supernatant was supplemented with NaCl and imidazole to final concentrations of 500 and 20 mM ...
-
bioRxiv - Neuroscience 2023Quote: ... The size of the SiNP was confirmed using dynamic light scattering (DLS) analysis performed on DelsaNano C equipped with the DelsaNano Software V3.73/2.3 (Beckman Coulter Inc.) in triplicate ...
-
bioRxiv - Neuroscience 2023Quote: Monomeric wild-type α-syn was ultracentrifuged at 90,000 RCF for 1 hour at 4 °C to remove any amorphous aggregates (Beckman Coulter Optima Max-XP with MLA-130 rotor) ...
-
Dopaminoceptive D1 and D2 neurons in ventral hippocampus arbitrate approach and avoidance in anxietybioRxiv - Neuroscience 2023Quote: ... 10 mM Tris-HCl) and centrifugated at 107,000 g for 1 hour at 4°C in a SW41Ti Swinging-Bucket Rotor (Beckman Coulter). Supernatant was discarded and nuclei pellets were re-suspended in 800 µL of PBS supplemented with 0.5% bovine serum albumin (BSA) ...
-
bioRxiv - Plant Biology 2023Quote: ... It was then centrifuged again at 100,000 x g for 1 h at 4 ⁰C (TLA 55 rotor, Beckman Coulter; OptimaTM Max ultracentrifuge, Beckman Coulter). The final pellet containing the purified EV fraction was resuspended in 50 µl of 20 mM Tris-HCl pH 6.0 ...
-
bioRxiv - Plant Biology 2023Quote: ... at 10,000 x g for 1 h at 4 ⁰C (JA-17 rotor, Beckman Coulter; Avanti J-20TM centrifuge, Beckman Coulter). The supernatant from this step was decanted into the new tubes and centrifuged at 39,800 x g for 2 h at 4 ⁰C (JA-17 rotor ...
-
bioRxiv - Systems Biology 2023Quote: ... The urine was centrifuged at 20,000 x g for 30 minutes at 4°C (k-factor 1,790) in an Optima XPN-80 ultracentrifuge (Beckman Coulter) equipped with a SW32 Ti swinging bucket rotor (Rmin 67 ...
-
bioRxiv - Molecular Biology 2023Quote: ... Cells were lysed by sonication and the lysate was clarified at 150,000 rcf for 30 min at 4°C using a Type 45 Ti Rotor (Beckman Coulter). The lysate was passed three times though 2mL of pre-equilibrated Ni-NTA Agarose beads (Qiagen ...
-
bioRxiv - Molecular Biology 2023Quote: ... Cells were lysed by sonication and the lysate was clarified at 150,000 rcf for 30 min at 4°C using a Type 45 Ti Rotor (Beckman Coulter). The lysate was passed three times through 2 mL of pre-equilibrated Ni-NTA Agarose beads (Qiagen ...
-
bioRxiv - Molecular Biology 2023Quote: ... The lysate was clarified at 150,000 rcf for 45 min at 4°C using a Type 45 Ti Rotor (Beckman Coulter). The supernatant was incubated with 3 mL IgG Sepharose 6 Fast Flow beads (Cytiva ...
-
bioRxiv - Molecular Biology 2023Quote: ... The lysate was clarified at 150,000 rcf for 30 min at 4°C using a Type 45 Ti Rotor (Beckman Coulter). The supernatant was incubated with 3 mL IgG Sepharose 6 Fast Flow beads (Cytiva ...
-
bioRxiv - Molecular Biology 2023Quote: ... The lysate was clarified at 503,000 rcf for 45 min at 4°C using a Type 70 Ti Rotor (Beckman Coulter). The supernatant was incubated with 3 mL IgG Sepharose 6 Fast Flow beads (Cytiva ...
-
bioRxiv - Cell Biology 2023Quote: ... loaded onto a discontinuous 0.75/1.0/2.33 M sucrose gradient and spin at 242,000 g for 1 h at 4 °C in a SW32Ti rotor (Beckman & Coutler). Growth cone fractions were collected at the interface load/0.75 M sucrose and non-growth cone fractions collected between 0.75/1.0 M sucrose and then analyzed by Western Blot.
-
bioRxiv - Cell Biology 2023Quote: ... The density adjusted FBS was subjected to ultracentrifugation for 25 h at 310,500 x g at 10°C in a 70Ti rotor (Beckman Coulter) before dialysis ...
-
bioRxiv - Cell Biology 2023Quote: ... the post-nuclear supernatant was centrifuged for 30 min at 100,000 x g at 4°C using a S120AT2 rotor (Beckman Coulter). The resulting pellet containing the membranes was resuspended in SDS sample buffer (see below).
-
bioRxiv - Cell Biology 2023Quote: ... 355647) and centrifuged at 35,000 rpm (100,000xg) for 40min at 4°C (Fixed-angle rotor, Beckman Coulter Optima Max Unltracentrifuge). 100K pellet (sEVs ...
-
bioRxiv - Molecular Biology 2023Quote: ... Ribosomes were isolated by sucrose cushion ultracentrifugation at 100,000 rpm at 4°C for 1 h using TLA110 rotor (Beckman Coulter). RNAs in the ribosome pellet were isolated with TRIzol-LS (Thermo Fisher Scientific ...
-
bioRxiv - Plant Biology 2023Quote: ... Approximately 250 µl of crude EV sample resuspended in 20 mM Tris-HCl pH 6.0 was slowly dispensed on top of the column and centrifuged at 100,000 x g for 17 h at 4 ⁰C (SW 41 Ti rotor, Beckman Coulter; OptimaTM L-90K, Beckman Coulter). After the ultracentrifugation ...
-
bioRxiv - Plant Biology 2023Quote: ... The tubes were then centrifuged at 100,000 x g for 1 h at 4 ⁰C (TLA 55 rotor, Beckman Coulter; OptimaTM Max ultracentrifuge, Beckman Coulter). The pellets from the tubes were pooled together in 500 µl of 20 mM Tris-HCl pH 6.0 buffer and the volume was brought up to 1,500 µl using 20 mM Tris-HCl ...
-
bioRxiv - Biophysics 2023Quote: ... Cell debris and unbroken cells were removed by centrifugation at 2,000 xg for 10 minutes and membranes were collected by ultracentrifugation at 186,000 xg for 1 hour at 4°C with a 45 Ti rotor (Beckman Coulter). The collected membrane was homogenized using a Dounce homogenizer in cold TBS buffer containing 1 mM PMSF ...
-
bioRxiv - Neuroscience 2023Quote: ... The gradients were centrifuged for 18 h at 100,000 xg at 4 °C in a SW 40 rotor (Beckman Coulter). 500 µl fractions were collected from the top of the ultracentrifuge tubes and analyzed by WB analysis.
-
bioRxiv - Biophysics 2023Quote: SpeMreBs in buffer S polymerized at room temperature with a volume of 200 μL were polymerized for 1–6 h and centrifuged (100,000 rpm at 23 °C for 120 min) in a TLA-100 rotor (Beckman Coulter) (2) ...
-
bioRxiv - Cell Biology 2022Quote: ... The supernatant was then transferred to polycarbonate tubes and centrifuged at 100,000 × g and 4°C for 1 h in a XL-90 ultracentrifuge (Beckman Coulter) ...
-
bioRxiv - Cell Biology 2022Quote: ... This spin was repeated and the resulting supernatant was then centrifuged for 1 h at 75,000 g at 4°C (TLA-100.3 rotor or Type60 Ti rotor; Beckman Coulter, USA). The supernatant was aspirated and the membrane pellet gently resuspended in microsome buffer (10 mM HEPES/KOH pH 7.5. ...
-
bioRxiv - Cell Biology 2022Quote: ... Lysates were cleared by centrifugation for 30 min at 4°C at 18,000 rpm (SS-34 rotor; Beckman-Coulter, USA).
-
bioRxiv - Cancer Biology 2023Quote: ... Samples homogenized in lysis buffer were loaded onto a 5%-20% linear gradient and centrifugated at 37,000 rpm for 170 min at 4°C in an SW41Ti rotor (Beckman Coulter).
-
bioRxiv - Cell Biology 2023Quote: ... down to 6 ml and ultracentrifuged at 10,000xg for 16 min at 4°C in MLA-80 rotor (Beckman Coulter). The pellet was resuspended and washed with PBS at the same conditions (volume ...