Labshake search
Citations for Beckman :
1001 - 1050 of 1672 citations for 7 Chloro 5 methyl 1H pyrrolo 2 3 c pyridine since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2021Quote: ... The density gradient centrifugation was performed at 141,000 g and 4 °C for 20 h in a SW28 swing rotor (Beckman Coulter). A total of 18 fractions were collected starting from the top.
-
bioRxiv - Microbiology 2021Quote: ... the wafer clump was collected using a pipette tip and resuspended in 3 mL of 2x Buffer C and mixed with 3 mL of 1x Buffer C (20 mM MES-Tris, 10 mM MgCl2, 50 mM KCl, pH 6.9) and pelleted in the ultracentrifuge (Beckman 50Ti). The resulting pellet was then resuspended in 200 µL of 1x Buffer C with 10% glycerol ...
-
bioRxiv - Neuroscience 2020Quote: ... Samples were centrifuged at 15,600 rpm and 4°C using a Swi32T swinging bucket rotor and Beckman ultracentrifuge (Beckman Coulter) for 45 minutes ...
-
bioRxiv - Microbiology 2021Quote: ... Archaella were pelleted from the supernatant by ultracentrifugation (60,000 × g, 90 min, 4 °C; Beckman Optima LE-80K, rotor 70Ti), resuspended in 150 μl 0.1 M HEPES/NAOH pH 7.0 and purified for 48 h (250,000 × g ...
-
bioRxiv - Molecular Biology 2020Quote: ... The sucrose gradients were centrifuged at 200,000 x g avg at 4°C for 173 min using a SW40Ti rotor (Beckman Coulter). After the spin ...
-
bioRxiv - Microbiology 2020Quote: ... Virus was pelleted at 1847 x g for 30 min at 4°C in the plate in an Allegra centrifuge (Beckman) and the pellet was resuspended in 50 uL of loading buffer with DTT for analysis by WB with αGag ...
-
kinesin recruitment by adapter SKIP on melanosomes is dynamically controlled by LC3B phosphorylationbioRxiv - Cell Biology 2021Quote: ... The post nuclear supernatant was collected and separated on a stepwise sucrose density gradient and centrifuged at 100,000 g for 1 hour at 4°C in a swing-out rotor (Beckman coulter). The sucrose density gradients comprised 0.25 ...
-
bioRxiv - Cell Biology 2020Quote: ... The cell lysate was collected in a flask on ice and ultracentrifuged at 4°C for 25 min at 50000 rpm using a Ti-70 rotor (Beckman). The protein purification was done through affinity chromatography on a Ni-column (HiTrap chelating HP column 1 ml ...
-
Micro RNAs are minor constituents of extracellular vesicles and are hardly delivered to target cellsbioRxiv - Cell Biology 2020Quote: ... FCS was diluted 1:1 with RPMI and centrifuged at 100,000 g at 4 °C in a swinging-bucket rotor (SW28 or 32, Beckman Coulter) for 18 h ...
-
bioRxiv - Microbiology 2021Quote: ... cell lysate was centrifuged 20 min at 14,000 rpm and 4°C to sediment cell debris and supernatant was transferred to microcentrifuge polypropylene tubes (Beckman Coulter) and cytoplasmic membranes were precipitated by ultracentrifugation for 45 min at 55,000 rpm and 4°C (Beckman Coulter rotor TLA 55) ...
-
bioRxiv - Molecular Biology 2022Quote: ... 800 µl of EDTA-treated lysate was layered on top of the sucrose gradient and ultracentrifuged at 35000 rpm for 4 hours at 4 °C in a SW41Ti rotor (Beckman). After centrifugation ...
-
bioRxiv - Biophysics 2022Quote: SpeMreBs with a volume of 200 μL were polymerised for 1 to 6 h and centrifuged (100,000 rpm, 23°C, 120 min) in a TLA-100 rotor (Beckman Coulter). The pellet was resuspended in 200 μL of water ...
-
bioRxiv - Molecular Biology 2022Quote: ... The lysate was clarified at 503,000 rcf for 45 min at 4°C using a Type 70 Ti Rotor (Beckman Coulter). The supernatant was incubated with 3 mL IgG Sepharose 6 Fast Flow beads (Cytiva ...
-
bioRxiv - Microbiology 2022Quote: ... The capsid-host protein complexes were sedimented through a 30% sucrose cushion at 110,000 g for 20 min at 4°C (TLA-100, Beckman-Coulter), resuspended in CBB by ultrasound tip sonication at 40 W for about 5 x 5 seconds on ice ...
-
bioRxiv - Biochemistry 2022Quote: ... and the debris and membranes were removed by ultracentrifugation at 205,000 g for 1 hr at 4 °C (rotor 45 Ti, Beckman Coulter). The supernatants were applied to IMAC with Ni2+-NTA-agarose resin (Qiagen ...
-
bioRxiv - Cell Biology 2022Quote: ... 1 M sucrose) and centrifuged at 100,000 RPM for 60 minutes at 4°C in a TLA100.3 rotor (Beckman Coulter, 349490) with 3.5 mL polycarbonate tubes (Beckman Coulter ...
-
bioRxiv - Biochemistry 2022Quote: ... and free tubulin was removed by pelleting the MTs by centrifugation at 313,000g for 10min at 25°C using TLA100 rotor (Beckman Coulter) through a sucrose cushion ...
-
bioRxiv - Molecular Biology 2022Quote: ... The sucrose gradient was centrifuged at 24,400 rcf for 1 h at 4°C in a SW41Ti Swinging-Bucket Rotor (Beckman Coulter), and nuclei at the bottom of the gradient were resuspended in PBS ...
-
bioRxiv - Biochemistry 2022Quote: ... The lysed cells were centrifuged at 41399 g and 6 °C and for 1 hour (Beckman Avanti J-25 centrifuge) to obtain the cytoplasmic protein extract.
-
bioRxiv - Biochemistry 2022Quote: Sedimentation velocity analytical ultracentrifugation was performed at 42,000 rpm at 20° C in an An-60 Ti rotor (Beckman Coulter), using standard charcoal double-sector centrepieces ...
-
bioRxiv - Neuroscience 2020Quote: ... The V and VI fractions were diluted to a total volume of 12 mL with dfPBS and centrifuged at 140,000 × g for 70 min at 4°C (# Optima-XE SW41 Beckman Coulter), and each pellet were resuspend with 30 μl of dfPBS ...
-
bioRxiv - Plant Biology 2021Quote: ... The thylakoid membranes with different densities were analytically separated at 125,000 × g and 4°C for 1 h (SW 41 Ti, Beckman Coulter).
-
bioRxiv - Microbiology 2020Quote: ... Cell containing supernatant was recovered into additional falcon tubes and centrifuged at 10,000G for 20 minutes with 4ºC cooling to pellet cells using an Avanti JXN-30 highspeed centrifuge with JA 14.50 fixed angle rotor (Beckman Coulter). Supernatant was removed without disturbing the cell pellet ...
-
bioRxiv - Microbiology 2020Quote: ... OBs were loaded on to a discontinuous 35–60% (w/w) sucrose gradient and centrifuged at 20000 rpm and 4°C for 1 hour in a SW41 rotor (Beckman). The band containing the OBs was removed ...
-
bioRxiv - Biochemistry 2021Quote: ... The sucrose loaded heavy MLVs were centrifuged at 180,000 x g for 30 min at 4°C using Optima TL benchtop Ultracentrifuge (Beckman Coulter). The resulting pellets were buffer exchanged by resuspension into the assay buffer comprising 50 mM HEPES pH 7.5 ...
-
bioRxiv - Molecular Biology 2021Quote: ... Insoluble material was removed by centrifugation (100,000 x g; 30 min; 4°C; 45 Ti rotor; Optima XPN-80; Beckman Coulter). The cell lysate supernatant was passed through a Ni+2-NTA resin column (Qiagen) ...
-
bioRxiv - Molecular Biology 2021Quote: ... The membrane fraction was pelleted down by high-speed centrifugation (100,000 x g; 4°C; 30 min; 45Ti rotor; Optima XPN-80, Beckman Coulter). The membrane pellet was resuspended in solubilization buffer ...
-
bioRxiv - Molecular Biology 2021Quote: ... Ultra-centrifugation was performed (160,000 x g; 16 hours; 4°C; SW 32 Ti rotor; Optima XPN-80, Beckman Coulter) and 1mL fractions were collected and analyzed by BN-PAGE ...
-
bioRxiv - Neuroscience 2022Quote: ... 10 mM Tris-HCl) and centrifugated at 24,000 rpm for 1 h at 4°C in a SW41Ti Swinging-Bucket Rotor (Beckman Coulter). Supernatant was discarded and nuclei pellets were re-suspended in 800 µL of PBS ...
-
bioRxiv - Microbiology 2020Quote: VLPs were collected after removal of cells from the enrichment culture (7,000 rpm, 20 min, Sorvall 1500 rotor) and concentrated by ultracentrifugation (40,000 rpm, 2h, 10°C, Beckman SW41 rotor). The particles were resuspended in buffer A ...
-
bioRxiv - Molecular Biology 2019Quote: ... followed by ultracentrifugation at 100,000 g for 2h in polyallomer tubes at 4 °C in a SW40 rotor (Beckman Coulter). Pelleted material was washed two times in filtered PBS at 100,000 g for 2h and re-suspended in PBS ...
-
bioRxiv - Cell Biology 2019Quote: ... and spun down at 4° C for 10 minutes at 12096×g using an Avanti J-25 centrifuge (Beckman Coulter). The sonicated lysate was incubated for 2 hours at 4 ° C with beads (Glutathione High Capacity Magnetic Agarose Beads ...
-
bioRxiv - Biochemistry 2019Quote: ... The supernatant was then slowly mixed with an equal volume of 4 M ammonium sulphate (2 M final concentration) at 4°C for 1 hour and spun at 10 K rpm using a JA-17 rotor (Beckman). Pellets containing RAD51 were suspended in 25 ml of resuspension buffer (0.5 M KCl ...
-
bioRxiv - Molecular Biology 2019Quote: ... and then centrifuged for 150 min at 39,000 rpm and 4°C in an Optima L-100XP Ultracentrifuge (Beckman-Coulter) using a SW41Ti rotor without brake ...
-
bioRxiv - Biochemistry 2019Quote: ... The supernatant from 2,000 × g was transferred to 30mL conical tube and then centrifuged at 10,000 × g for 10 min at 4°C (# Avanti J-E JA25-50 Beckman Coulter). The supernatant from this spin was filtered through a 0.22-μm mesh filter (# SLGP033RS EMD Millipore ...
-
bioRxiv - Biochemistry 2019Quote: ... The V and VI fractions were then diluted separately to a total volume of 12mL with dfPBS and centrifuged at 100,000 × g for 70 min at 4°C (# Optima-XE SW41 Beckman Coulter). The final pellet from each fraction was resuspended in 30 μL of dfPBS ...
-
bioRxiv - Cell Biology 2020Quote: ... The supernatant of MNase treated chromatin were overlaid onto the sucrose gradient and spun at 32000 rpm (124,436 rcf) for 13 h at 4 °C using SW55Ti rotor (Beckman Coulter) in Beckman Optima L80.
-
bioRxiv - Cell Biology 2020Quote: ... 1 mM EGTA) and spun at 32000 rpm (124,436 rcf) and 4 °C for 13 h using SW55Ti rotor (Beckman Coulter) in Beckman Optima L80 ...
-
bioRxiv - Synthetic Biology 2019Quote: ... then centrifuged at 5000 x g and 10°C for 10 minutes (Avanti□ J-E Centrifuge, Beckman Coulter, Indianapolis, IN). After disposing the supernatant ...
-
bioRxiv - Microbiology 2021Quote: ... The treated cells were pelleted by centrifugation at 12,000×g at 4 °C for 20 min (Beckman Allegra X-15R) and the supernatant was discarded ...
-
bioRxiv - Plant Biology 2020Quote: ... The insoluble cell debris was removed via centrifugation for 30 min at 4°C and 20,000 rpm (JA-25.50, Beckman Coulter®). The supernatant was incubated for 1 h with low agitation and with 1.2 ml Glutathione-sepharose (GE-Healthcare ...
-
bioRxiv - Plant Biology 2020Quote: ... the cells were harvested by centrifuging for 30 min at 4°C and 6,000 rpm (JA-10, Beckman Coulter®). The cells were resuspended in 1x PBS (pH 7.3 ...
-
bioRxiv - Immunology 2020Quote: ... Then the concentrated supernatant was ultracentrifuged at 110,000 g for 1 hour at 4°C (Beckman Coulter L100k, company name) to sediment the vesicular fraction into a pellet ...
-
bioRxiv - Microbiology 2020Quote: ... pH 7.5) at 45,000 RPM for 45 minutes at 11 °C in a Beckman 70.1 Ti rotor (Beckman Coulter, Brea, California). The pellet was resuspended in 10 mM Tris-HCl ...
-
bioRxiv - Genomics 2021Quote: ... The tubes were then balanced and centrifuged in a Beckman Coulter L7-65 Ultracentrifuge at 25,000rpm at 4°C for 2hr using a Beckman Coulter SW28 swing bucket rotor (Beckman Coulter). The supernatant was carefully removed via aspiration ...
-
bioRxiv - Biochemistry 2019Quote: ... Ribosomes were pelleted via centrifugation at 63,000 x g for 16-18 hours at 4°C using a Type 80 Ti rotor (Beckman Coulter). Ribosome pellets were dissolved in resuspension buffer (20 mM Tris-HCl pH 7.5 ...
-
bioRxiv - Biochemistry 2019Quote: ... Fractions containing 40S and 60S ribosomal subunits as identified via absorption at 254 nM were pelleted via centrifugation at 63,000 x g for 20 hours at 4°C using a Type 80 Ti rotor (Beckman Coulter). Ribosomal subunits were resuspended in storage buffer (30 mM HEPES-KOH pH 7.4 ...
-
bioRxiv - Biochemistry 2019Quote: ... The homogenate was centrifuged for 10 min at 10,000×g at 4°C in a Ti-70 rotor and Optima XPN-90 ultracentrifuge (Beckman Coulter) and the supernatant was removed ...
-
bioRxiv - Molecular Biology 2020Quote: ... by centrifuging at 63,000 x g for 18 hrs at 4°C using a Type 80 Ti rotor (Beckman Coulter). Pellets were resuspended and these samples were analysed by mass spectrometry.
-
Heatrich-BS enables efficient CpG enrichment and highly scalable cell-free DNA methylation profilingbioRxiv - Genomics 2021Quote: ... the sample was incubated at 25°C for 1 hour and then cleaned up by performing two rounds of 1.2x SPRI Select (Beckman Coulter). The sample was then subject to bisulfite conversion following the recommended protocol of Zymo EZ DNA Methylation kit (Zymo Research) ...