Labshake search
Citations for Bio-Rad :
4701 - 4750 of 9194 citations for Glutathione Fluorescent 384 Well Detection Kit 2 Plate since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2022Quote: ... Proteins were denatured for 5 min at 95°C and separated by SDS-PAGE using precast 10% polyacrylamide 10-well (Bio-Rad, #456-1034) or 18-well (Bio-Rad ...
-
bioRxiv - Molecular Biology 2019Quote: ... The samples were boiled (95°C) and 18 µL were loaded onto a 4-20% Mini-PROTEAN®TGX™ 12 well-gel (Biorad®). After transfer onto a PVDF (Amersham Hybond ...
-
bioRxiv - Cell Biology 2020Quote: Purified recombinant proteins and protein extracts prepared from harvested cells or immunoprecipitation experiments in reducing Laemmli Sample Buffer were run on 4–20 % Mini-PROTEAN® TGX™ Precast Protein Gels of different comb and well-sizes (Bio-Rad, #456-1093 ...
-
bioRxiv - Bioengineering 2021Quote: ... Target amplification within each droplet was conducted in the C1000 Touch™ Thermal Cycler with 96-Deep Well Reaction Module (Bio-Rad, 1851197) through the following PCR protocol ...
-
bioRxiv - Microbiology 2022Quote: ... 10 μg of protein was loaded from each sample into separate wells of a 4-15% polyacrylamide gel (Bio-Rad Laboratories, 456-8084). Electrophoresis was performed in 1x Tris/Glycine Buffer (Bio-Rad Laboratories ...
-
bioRxiv - Plant Biology 2022Quote: ... and the total soluble protein extracts (25 μl or 40 μl per well) were separated on 4-20% Mini-PROTEAN TGX precast polyacrylamide gels (Bio-Rad, Hercules, CA) and subsequently transferred to a 0.45 μm nitrocellulose membrane (GVS ...
-
bioRxiv - Immunology 2022Quote: ELISA plates were coated with 50 µL/well of 5 µg/mL of mouse anti-bovine IFN-γ monoclonal antibody (mAb) (CC330, Bio-Rad Antibodies) by overnight incubation at 4°C ...
-
bioRxiv - Immunology 2022Quote: ... Equal amount of total protein (25 μg/well) was resolved by electrophoresis on 8% Tris-Acrylamide gels and transferred onto 0.2 μm nitrocellulose membranes (Bio-Rad Laboratories, CA, US). Membranes were blocked for 1 h at room temperature in 5% skim milk diluted in Tris-buffered saline supplemented with 0.1% Tween 20 (TBST) ...
-
bioRxiv - Pathology 2024Quote: ... 15 µg of proteins were resolved on Criterion TGX Stain-Free 4-15%,18 and 26-well gel (Bio-Rad Laboratories, #5678084, #5678085) in a Criterion large format electrophoresis cell (Bio-Rad Laboratories ...
-
bioRxiv - Immunology 2024Quote: ... and lysates of equal concentration were prepared and run by SDS-PAGE on Bio-Rad Criterion 4–15% 26-well gradient gel (Bio-Rad, CAT#5678095). Gels were transferred using the Trans-Blot Turbo system (Bio-Rad ...
-
bioRxiv - Cancer Biology 2023Quote: ... and approximately 20 µg of sample were loaded onto each well and run on a Mini Protean TGX Gel (Bio-Rad, 456-1046) before being transferred to an Immobilon Transfer Membrane (Millipore ...
-
bioRxiv - Cancer Biology 2023Quote: ... and approximately 20 μg of sample were loaded onto each well and run on a Mini Protean TGX Gel (Bio-Rad, 456-1046) before being transferred to an Immobilon Transfer Membrane (Millipore ...
-
bioRxiv - Genomics 2023Quote: ... 20-25ug of protein lysate was loaded per well and separated on a 4–20% Mini-PROTEAN® TGX Stain-Free™ Protein Gel (Bio-Rad). Proteins were transferred onto an activated PVDF membrane using the Trans-Blot Turbo Transfer system (Bio-Rad) ...
-
bioRxiv - Cell Biology 2024Quote: ... 15 μl of homogenized lysate was used for SDS–polyacrylamide gel electrophoresis (Mini-PROTEAN® TGX™ Precast Gels, 10 wells, Bio-Rad). Proteins were transferred to a Hybond nitrocellulose membrane (Thermo Fisher Scientific ...
-
bioRxiv - Microbiology 2019Quote: Pre-cultures were made from calibrated explants (5 mm) deposited on plate with solid Sisler medium previously covered with a sterile cellophane membrane (Bio-Rad, USA). The cultures were maintained 4 days at 20°C ...
-
bioRxiv - Bioengineering 2020Quote: ... Bioengineered intestinal tubules were exposed to reaction mixture for 30 min and absorbance was measured at 600 nm using colorimetric plate reader (iMARK™ microplate absorbance reader, Bio-Rad). Values are shown relative to medium exposed.
-
bioRxiv - Microbiology 2020Quote: ... Colonization of SEΔΔΔ was quantified by dilution plating and counting colony forming units (CFU) on SASelect plates supplemented with 100 μg/mL D-alanine (BioRad, Hercules, CA). All experiments were done in triplicate.
-
bioRxiv - Neuroscience 2021Quote: ... Plates containing the amplified droplets were loaded into the QX200 droplet reader and results were analysed using QuantaSoft software™ (Bio-Rad).
-
ATM-mediated DNA damage response in macrophages primes phagocytosis and immune checkpoint regulationbioRxiv - Immunology 2020Quote: ... and the corresponding 5 μl of Primer Master-mix was added followed by sealing the plate with Microseal ® adhesive sealer (Bio-Rad). The 60S acidic ribosomal protein P0 (rplp0) ...
-
bioRxiv - Neuroscience 2020Quote: ... Amplifications were conducted using Bio-Rad SYBR green according to manufacturer’s instructions and plates were run in Bio-Rad CFX optical system (BioRad Laboratories, Hercules, CA). Primers were design to work at +60°C and to span an exon junction using online software at http://www.ncbi.nlm.nih.gov ...
-
bioRxiv - Cell Biology 2020Quote: ... after which the plates were air-dried for 30 min and developed using a K-screen and FX-Imager (Bio-Rad Laboratories).
-
bioRxiv - Cell Biology 2020Quote: ... Cells were allowed to adhere on plate/coverslips for 24 hours and then transfected with 20 nm of siRNA using siLentFect™ lipid reagent (Bio-Rad) for 24 hours.
-
bioRxiv - Genetics 2022Quote: ... The agar plates were incubated at the indicated temperatures and time and imaged using the ChemiDoc™ Touch Imaging System (Bio-Rad).
-
bioRxiv - Synthetic Biology 2022Quote: ... The solid cultures were grown at 30ºC without shaking for 48 h and pictures of cell plates were taken using the colorimetric mode of Chemidoc Touch Imaging Systems (Bio-Rad, USA). All halo assays were conducted in three biological replicates.
-
bioRxiv - Molecular Biology 2023Quote: ... The concentration of Evans blue was quantified spectrophotometrically at 620 nm using a plate reader (iMark microplate reader, Bio-Rad, CA, USA). To assess local vascular permeability in the skin ...
-
bioRxiv - Immunology 2023Quote: ... Each antigen concentration was determined by UV absorbance at 450 nm in a plate reader (iMark™ Microplate Absorbance Reader, BioRad, Japan).
-
bioRxiv - Cancer Biology 2023Quote: ... Crystal violet was removed by repeated rinses with water and plates dried overnight before imaging on the Bio-Rad ChemiDoc Touch System (Bio-Rad Laboratories).
-
Dual inhibition of coronavirus Mpro and PLpro enzymes by phenothiazines and their antiviral activitybioRxiv - Microbiology 2023Quote: ... Plates were read at an absorbance of 490 nm with an xMark™ microplate absorbance spectrophotometer (Bio-Rad Laboratories, Hercules, California US). GraphPad PRISM v.10 (https://graphpad.com ...
-
bioRxiv - Molecular Biology 2020Quote: ... The mixture was then treated with 5% volume of Bio-Bead SM-2 resin (Bio-Rad) with shaking on ice for 15 min ...
-
bioRxiv - Immunology 2022Quote: ... SARS-CoV-2 specific genome levels were measured by qPCR using SsoFast EvaGreen supermix (Bio-Rad) according to manufacturer’s protocol.
-
bioRxiv - Molecular Biology 2019Quote: ... Proteins were then transferred (200 mA for 2 hours) to polyvinylidene difluoride membranes (Bio-Rad Laboratories), Ponceau stained ...
-
bioRxiv - Biochemistry 2020Quote: ... Biotinylated small RNAs were separated from HPDP-biotin and pyridine-2-thione using spin columns (BioRad) in ultra-pure water.
-
bioRxiv - Developmental Biology 2020Quote: ... We ran the qPCR reactions using 1-2 µl cDNA in SYBR Green Master Mix (Biorad) totaling 20 µl in a Biorad CFX96 machine using 60°C as the annealing temperature ...
-
bioRxiv - Bioengineering 2021Quote: ... and the selected primers (Table 2) using a CFX Connect™ Real-Time System (Bio-Rad) under the following conditions ...
-
bioRxiv - Cell Biology 2021Quote: ... The following primary antibodies were used: anti–α-tubulin (MCA77G YL1/2, rat monoclonal; Bio-Rad), anti-GAPDH (mouse ...
-
bioRxiv - Cell Biology 2021Quote: Samples for electrophoresis were prepared by mixing with 2× Laemmli sample buffer (Bio-rad, Hercules, California) and denatured at 55°C for 5 min ...
-
bioRxiv - Cell Biology 2021Quote: ... 2-3 μg of total protein were loaded onto 10% SDS-polyacrylamide (29:1 Bio-Rad) gels with 10 μM phostag reagent (FUJIFILM Wako Chemicals ...
-
bioRxiv - Microbiology 2020Quote: ... in a 100 μL reaction for 2 hours and purified using P-30 spin columns (BioRad). The radiolabeled probe was heated to 100°C for 2 minutes and resuspended in 10 mL of ULTRAhyb Oligo hybridization buffer (Ambion) ...
-
bioRxiv - Cancer Biology 2020Quote: ... Two percent agarose gel was prepared by dissolving 2 g Agarose (Bio-rad, Cat No. 1613102) and 2 µL SYBR Safe DNA Gel Stain (Invitrogen ...
-
bioRxiv - Cell Biology 2021Quote: ... The beads were washed 3 times and then eluted using 2 × Laemmli Sample Buffer (Bio-Rad). The elution was subjected to SDS PAGE to run the sample into the lane ...
-
bioRxiv - Developmental Biology 2022Quote: ... Supernatant fractions were collected by centrifugation and boiled with 2× Laemmli sample buffer (Bio-Rad, 1610737) at 95 °C for 8-10 min ...
-
bioRxiv - Biochemistry 2022Quote: Cell lysates were diluted to 2 µg/µl in Laemmli buffer (Bio-Rad, Hercules CA, 1610747) and heated at 95ºC for 5 minutes and resolved using a 4-20% tris-glycine gel (ThermoFisher Scientific ...
-
bioRxiv - Neuroscience 2019Quote: ... Slices were mounted on slides in reagent 2 in frame-seal incubation chambers (Bio-Rad SLF0601) and coverslipped ...
-
bioRxiv - Biophysics 2020Quote: ... Detergent was slowly removed by the addition of SM-2 Bio-Beads (Bio-Rad, Hercules, CA) over a 4-hour time course (final weight ratio of 25 Bio-Beads to 1 detergent) ...
-
bioRxiv - Biophysics 2020Quote: ... Nanodisc reconstitution was achieved by incubation with 0.5 - 1 mL Bio-Beads SM-2 (Bio-Rad) for 16 hours at 4°C under constant rotation ...
-
bioRxiv - Microbiology 2021Quote: ... each cDNA was combined with segment-specific primers (Table 2) and Precision Melt Supermix (Bio-Rad) and analyzed by qPCR using a CFX384 Touch real-time PCR detection system (Bio-Rad) ...
-
bioRxiv - Microbiology 2019Quote: ... mixed thoroughly and the mixture transferred to an electroporation 2 mm-gap width cuvette (Bio-Rad). Electrotransformation was performed in a Micropulser™ device (Bio-Rad Laboratories ...
-
bioRxiv - Cell Biology 2019Quote: ... and probed with each primary antibody diluted in 2% blotting-grade non-fat dry milk (BioRad). Next ...
-
bioRxiv - Molecular Biology 2020Quote: RNA samples (2 μg) were loaded onto a 10% Criterion TBE-urea precast gels (Bio-Rad) and electrophoresed at 70 V until the dye front reached the bottom of the gel ...
-
bioRxiv - Cancer Biology 2019Quote: ... 5% of the lysates were boiled with 2 x laemmli buffer (BIO-RAD, Hercules, CA, USA) and used as input ...