Labshake search
Citations for World Precision Instruments :
2301 - 2350 of 3820 citations since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biophysics 2021Quote: ... oocytes were transferred to a 2 μl media droplet in a 35 mm glass bottom FluoroDish from WPI covered with 400-500 μl of oil ...
-
bioRxiv - Biophysics 2021Quote: ... Cells were plated on 35 mm glass bottom FluoroDishes from WPI for imaging ...
-
bioRxiv - Neuroscience 2021Quote: ... +/−2.6mm ML, −4.5mm DV) using a 10μL syringe (nanofil, World Precision Instrument, USA) with NanoFil Needle (NF33BV-2, World Precision Instruments, USA) at a rate of 100nL/min (Micro4 pump ...
-
bioRxiv - Neuroscience 2021Quote: ... at a rate of 100nL/min (Micro4 pump, World Precision Instruments, USA).
-
bioRxiv - Neuroscience 2021Quote: Borosilicate glass patch electrodes (WPI, Sarasota, FL, USA) were used to acquire whole-cell patch-clamp or field recordings in the NAc core ...
-
bioRxiv - Biochemistry 2021Quote: ... cells were re-plated onto either poly-D-lysine coated glass-bottomed FluoroDishes (FD35-PDL-100, World Precision Instruments) or poly-L-lysine coated 35 mm petri dishes (Corning) ...
-
bioRxiv - Bioengineering 2021Quote: Transepithelial electrical resistance (TEER) was measured with an EVOM2 epithelial volt/ohm meter (World Precision Instruments, Sarasota, FL). Before use ...
-
bioRxiv - Bioengineering 2021Quote: ... A silicone elastomer Kwiksil (World Precision Instruments, FL) was used to insulate the nerve-electrode interface from the surrounding fluid.
-
bioRxiv - Bioengineering 2021Quote: ... the PDMS slabs resulting from the molding processes were cut to the size of the chip and ports to access the chips were pierced using a biopsy punch (Disposable Biopsy Punch, 0.75 mm diameter; 504529; World Precision Instruments, Friedberg, Germany). To enable O2-plasma-based bonding of the PET-membrane ...
-
bioRxiv - Bioengineering 2021Quote: ... the exposed skull was protected by a biocompatible sealant (Kwik-Cast, World Precision Instruments), which can be peeled off before the imaging experiment.
-
bioRxiv - Bioengineering 2021Quote: ... Electrochemical characterizations were performed in a three-electrode configuration, using a thick (2-mm diameter, ~5 mm2) Pt wire (WPI, 99.99%) as counter electrode (CE ...
-
bioRxiv - Bioengineering 2021Quote: ... Trans endothelial electrical resistance (TEER) of BBB constructs was measured using the Epithelial Volt/Ohm Meter (World Precision Instruments, Sarasota, FL). Permeability of the BBB construct was measured by quantifying 5 kDa FITC-dextran diffusion across the barrier ...
-
bioRxiv - Bioengineering 2021Quote: ... A 1.5 mm hole puncher (World Precision Instruments) was used to generate holes to provide inlets and outlets of the upper and bottom channels.
-
bioRxiv - Bioengineering 2021Quote: ... the inlet of the top channel was connected to a syringe pump (World Precision Instruments) with a 2 mL syringe ...
-
bioRxiv - Bioengineering 2021Quote: ... Fiber solutions were extruded using 27G needles and a sub microliter injection needle (World Precision Instruments, Nano-Fil 100), with two different extrusion printers (Allevi 2 ...
-
bioRxiv - Bioengineering 2021Quote: ... Platine (Pt) and Silver chloride (Ag/AgCl) electrodes were purchased from WPI. Solutions were prepared with Deionized water (18 MΩ) ...
-
bioRxiv - Neuroscience 2021Quote: ... The construct was loaded into a 10 μl Nanofil syringe (World Precision Instruments) to which a beveled 34 GA needle (World Precision Instruments ...
-
bioRxiv - Neuroscience 2021Quote: ... to which a beveled 34 GA needle (World Precision Instruments) was assembled prior to injections into the cortex under microscopic control using a microinjection system (UMP3-1 ...
-
bioRxiv - Neuroscience 2021Quote: ... was assembled prior to injections into the cortex under microscopic control using a microinjection system (UMP3-1, SYS-Micro 4; World Precision Instruments). To increase optogenetic responses after one year ...
-
bioRxiv - Biophysics 2021Quote: ... The detached cells were transferred to poly-Lys-treated 35 mm single dishes (FluoroDish, World Precision Instruments) and incubated overnight at 37 °C in fresh media ...
-
bioRxiv - Neuroscience 2021Quote: ... Craniotomies were sealed with kwik-sil (World Precision Instruments, Sarasota, FL) until the day of the recording ...
-
bioRxiv - Neuroscience 2021Quote: ... Electrical stimulation was generated using an isolator unit (WPI) controlled by Master-8 pulse generator (AMPI) ...
-
bioRxiv - Neuroscience 2021Quote: ... A 10-µl Hamilton syringe connected to an UltraMicroPump and SYS-Mico4 controller (WPI, Sarasota, FL) was used to deliver 0.7 µl of AAV5-hSyn-hChR2(H134R)-eYFP (University of North Carolina vector core) ...
-
bioRxiv - Neuroscience 2021Quote: ... using an automated stereotaxic injection apparatus (Model UMC4, World Precision Instruments Inc.). The microsyringe was left in place for an additional 10 mins after each injection.
-
bioRxiv - Neuroscience 2021Quote: ... The recording glass electrode (thin-wall glass capillaries; OD, 1.0 mm; length, 76 mm; World Precision Instruments, cat. # TW100F-3) was pulled using a micropipette puller (Sutter Instrument ...
-
bioRxiv - Neuroscience 2021Quote: ... The Hamilton syringe was mounted into a motorized microinjector (UMP3T-2, WPI) that was held by a manipulator (model 1460 ...
-
bioRxiv - Neuroscience 2021Quote: ... The syringe was fixed to a digital syringe driver (UMP3 microsyringe injector with Micro4 controller; World Precision Instruments; Sarasota, FL). This system allows simultaneous drug delivery and neural recordings as described and validated in previous studies (Rohatgi et al. ...
-
bioRxiv - Neuroscience 2021Quote: ... Silicone adhesive was applied around the working electrode to prevent cortical tissue damage from the heat of curing dental cement (World Precision Instruments, Sarasota, FL, USA). Skull screws ...
-
bioRxiv - Neuroscience 2021Quote: ... AAVs carrying sgRNAs or control viruses were loaded via a glass pipette connected with a 10 μl Hamilton syringe (Hamilton, 80308, US) on a syringe injection pump (WPI, SP101I, US) and injected at a speed of 0.15 μl/min ...
-
bioRxiv - Neuroscience 2021Quote: ... with patch pipettes (2-3 MΩ) pulled from borosilicate pipettes (TW150-4, WPI, USA) using PC-10 puller (Narishige ...
-
bioRxiv - Neuroscience 2021Quote: ... then the edges of the window were sealed with silicon elastomer (Kwik-Sil, World Precision Instruments), then with dental acrylic (C&B-Metabond ...
-
bioRxiv - Neuroscience 2021Quote: ... A cranial window was implanted over the craniotomy and sealed first with silicon elastomer (Kwik-Sil, World Precision Instruments) then with dental acrylic (C&B-Metabond ...
-
bioRxiv - Neuroscience 2021Quote: ... A cylindrical cannula-based optical window was fitted to the craniotomy in contact to the external capsule and a thin layer of silicone elastomer (Kwik-Sil, World Precision Instruments, Sarasota, FL) was used to surround the interface between the brain tissue and the steel surface of the optical window ...
-
bioRxiv - Neuroscience 2021Quote: ... 800 nL of AAV solution was injected at 100 nL/min by means of a hydraulic injection apparatus driven by a syringe pump (UltraMicroPump, WPI, Sarasota, FL). Following the viral injection ...
-
bioRxiv - Neuroscience 2021Quote: ... 100□nL of viral solution (109 particles) were injected intra– cranially in a localized fashion using a micropump and syringe (Nanofil WPI) at a rate of 100□nl / min into the left DG (AP −2.00 mm ...
-
bioRxiv - Neuroscience 2021Quote: ... A Nanofil syringe equipped with a 35G blunt ended needle (World Precision Instruments) was inserted via the pre-punctured hole ...
-
bioRxiv - Neuroscience 2021Quote: ... Viruses were infused at 100 nl/min through a blunt 33-gauge injection needle using a syringe pump (World Precision Instruments). The needle was left in place for 5 min following the end of the injection ...
-
bioRxiv - Neuroscience 2021Quote: ... The taste solutions were back-filled into recording electrodes (World Precision Instruments, 1B150F-3). Action potentials induced by the tastants were amplified and digitalized using an IDAC-4 data acquisition software ...
-
All-trans retinoic acid induces synaptopodin-dependent metaplasticity in mouse dentate granule cellsbioRxiv - Neuroscience 2021Quote: ... Then a tungsten recording electrode (TM33B01KT, World Precision Instruments) was lowered in 0.1 mm increments while monitoring the waveform of the field excitatory postsynaptic potential (fEPSP ...
-
bioRxiv - Neuroscience 2021Quote: ... Laser output was controlled using a pulse generator (accupulser, WPI), which delivered single continuous light pulses of 50-1000 ms ...
-
bioRxiv - Neuroscience 2021Quote: ... 0.5 M sucrose in bath solution were puffed by a Picospritzer III (Parker Hannifin) through a fused silica needle (28 gauge, WPI), which placed ∼500 µm away from the soma of aimed neuron ...
-
bioRxiv - Neuroscience 2021Quote: ... connected to a stimulus isolation unit (A360, WPI). These bundles are identified throughout as ‘input’ ...
-
bioRxiv - Neuroscience 2021Quote: Extracellular signals were amplified at 100x gain and filtered through a 10-to 3000-Hz bandwidth filter on a DAM50 differential amplifier (World Precision Instruments, Sarasota, USA), with 50 Hz noise removed with a HumBug (Quest Scientific ...
-
bioRxiv - Neuroscience 2021Quote: ... via a 10 μl Nanofil syringe and 33GA beveled needle (World Precision Instruments, Sarasota, FL, USA) at an infusion rate of 150 nL/min ...
-
bioRxiv - Neuroscience 2021Quote: ... in a recording chamber (Fluorodish, World Precision Instruments) and constantly perfused with artificial fish water (AFW ...
-
bioRxiv - Neuroscience 2021Quote: Low-resistance patch electrodes (3–4 MΩ) were pulled from filamented borosilicate patch electrodes (World Precision Instruments, USA) with a PC-100 micropipette puller (Narishige ...
-
bioRxiv - Neuroscience 2021Quote: ... placed in stratum pyramidale of CA1 area and connected to ISO DAM-8A amplifier (WPI, FL) or MultiClamp 700B amplifier (Axon Instruments ...
-
bioRxiv - Neuroscience 2021Quote: ... was used to make recording electrodes (thin-wall glass, WPI Instruments, Sarasota FL) of resistances from 3-6 MΩ ...
-
bioRxiv - Neuroscience 2021Quote: ... Patch pipettes pulled from thin borosilicate capillary glass (World Precision Instruments) with a Sutter P-97 horizontal puller had a resistance of 3–5 MΩ ...
-
bioRxiv - Neuroscience 2021Quote: ... injected at 1 µl/min via a NanoFil needle (36G, World Precision Instruments; 30 s injection, Newcastle) or at 0.2 µl/min via a 40 μm glass pipette (Legato 130 ...