Labshake search
Citations for World Precision Instruments :
2351 - 2400 of 3820 citations since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2021Quote: ... A Hamilton nanofill syringe needle (36G, World Precision Instruments) was then guided through the hole ...
-
bioRxiv - Neuroscience 2021Quote: ... which in turn triggered a battery-powered constant current stimulus isolator A365 (World Precision Instruments, USA) to produce 60 biphasic pulses ...
-
bioRxiv - Neuroscience 2021Quote: ... Silicone elastomer (Kwik-Cast, WPI, Sarasota, FL, USA) was placed into the craniotomy to prevent brain swelling ...
-
bioRxiv - Neuroscience 2021Quote: Primary rat E18 hippocampal neurons plated in Fluorodishes (cover-glass bottom, 35 mm, WPI Inc.) were infected at DIV10 and analysed in live cell experiments at DIV20-24 ...
-
bioRxiv - Neuroscience 2021Quote: ... The tube-fixed needle was then inserted into the nanosyringe which was then loaded into the stereotaxic holder of the microsyringe pump (World Precision Instruments). The saline solution was pushed to the tip of the PTFE tubing ...
-
bioRxiv - Neuroscience 2021Quote: A 10 μl nanosyringe (World Precision Instruments, Sarasota, FL, USA) is first filled with the fluid to be injected before connecting it to the fluidic line of the multifunctional optrode ...
-
bioRxiv - Neuroscience 2021Quote: ... The tip of a pulled glass capillary tube attached to a Micro4 infusion device (World Precision Instruments, USA) was slowly inserted stereotaxically to a depth of 500 μm into the C5 level of the spinal cord and approximately 600 μm lateral from the midline ...
-
bioRxiv - Neuroscience 2021Quote: ... Patch electrodes were fabricated from borosilicate glass (Cat. No. 1B150F-4,1.5 mm outer diameter; World Precision Instruments, Sarasota, FL) with the P-2000 puller (Sutter Instruments ...
-
Ventral tegmental area glutamate neurons mediate the nonassociative consequences of traumatic stressbioRxiv - Neuroscience 2021Quote: ... All AAVs were injected at 2-5 x 1012 titer The total injection volume (500 nL) and flow rate (100 nL/min) were controlled with a microinjection pump (Micro4; World Precision Instruments, Sarasota, FL). Following injection ...
-
bioRxiv - Neuroscience 2021Quote: ... Viruses and/or retrobeads were injected into the brain at 50-100 nl/min through a blunt 33-gauge needle using a syringe pump (World Precision Instruments). The needle was left in place for 5 min following the end of the injection ...
-
bioRxiv - Neuroscience 2021Quote: ... Stimulating currents of 10-20 µA were delivered through a stimulus isolator (A360 World Precision Instruments, Sarasota, FL, USA). For the main set of recordings ...
-
bioRxiv - Neuroscience 2021Quote: ... and covered with a thick layer of Kwik-Cast Sealant (WPI, Sarasota, FL, USA). Post-operative analgesia was provided with an intraperitoneal injection of buprenorphium (0.1 mg/kg) ...
-
bioRxiv - Neuroscience 2021Quote: ... the craniotomy and the Ag/AgCl ground pellet (1 × 2.5 mm, World Precision Instruments) were then submerged in a 2 % agarose (in saline ...
-
bioRxiv - Neuroscience 2021Quote: ... intraperitoneal) dissolved in sterile isotonic saline (NaCl 0.9%) and mounted onto a stereotaxic frame (World Precision Instruments). AAVRh10-DGKκ were injected bilaterally into the striatum (coordinates relative to bregma ...
-
bioRxiv - Neuroscience 2021Quote: ... The patch electrodes (3-4 MΩ, World Precision Instruments; 1B150F-3) were filled with intracellular solution containing ...
-
bioRxiv - Neuroscience 2021Quote: ... directly on the S1 site to protect the thinned skull from contamination and infection and sealed the exposed skull with a silicone elastomer (Kwik-Cast, World Precision Instruments).
-
bioRxiv - Neuroscience 2021Quote: ... We used the Nanoliter2000 system (World Precision Instruments [WPI], Sarasota County, FL, USA) for all infusions ...
-
bioRxiv - Neuroscience 2021Quote: ... We used the Nanoliter2000 system (World Precision Instruments [WPI], Sarasota County, FL, USA) for all infusions ...
-
bioRxiv - Neuroscience 2021Quote: ... We monitored ICP via the cisterna magna cannula connected to a transducer attached to a pressure monitor (BP-1, World Precision Instruments Inc., Sarasota, FL). In another set of experiments ...
-
bioRxiv - Neuroscience 2021Quote: ... 2.0-2.3 mm lateral to midline and 2.0-2.5 mm posterior to bregma) at a rate of 60 nL/min at a concentration of 2 mM using a Nanoliter 2020 system (WPI). Optogenetic silencing of V1 was achieved by the use of mice in which channelrhodopsin-2 expression was driven by cre in parvalbumin positive interneurons (Ai32 x PVcre) ...
-
bioRxiv - Neuroscience 2021Quote: ... An EVOM voltohmmeter (World Precision Instruments Inc., Sarasota, FL) was used to measure TEER and experiments were performed once the monolayers reached a TEER of >30 ohm-cm2 ...
-
bioRxiv - Neuroscience 2021Quote: ... Raw voltages were amplified and filtered (band-pass 10 Hz – 10 kHz) with ISO-DAM 8A modules (World Precision Instruments, Sarasota, FL), and digitized at 30 kHz with the Cerebus Neural Signal Processors ...
-
bioRxiv - Neuroscience 2021Quote: The multifunctional optrode was connected to the stereotaxic frame via a custom designed 3D-printed stereotaxic attachment that is held by a stereotaxic cannula holder (World Precision Instruments) (Fig ...
-
Neurexin-3 defines synapse- and sex-dependent diversity of GABAergic inhibition in ventral subiculumbioRxiv - Neuroscience 2021Quote: ... were injected with pulled glass micropipettes into ventral subiculum at a rate of 11-14 µL/hr using a syringe pump (World Precision Instruments). Coordinates (in mm ...
-
bioRxiv - Neuroscience 2021Quote: ... FG105UCA) that was glued to a tungsten electrode (WPI, TM33B20, shaft diameter = 0.256 mm) with epoxy (Devcon – 5 Minute Epoxy) ...
-
bioRxiv - Neuroscience 2021Quote: ... AAV2-GFP was microinjected into lumbar DRGs using a micropipette pulled to a diameter of 0.05 mm and a nanoinjector (World Precision Instruments, Sarasota, FL). The viruses were injected at the time of DR crush ...
-
bioRxiv - Neuroscience 2021Quote: ... and the rats were then head-fixed into a stereotaxic frame (World Precision Instruments,). The surgical surface was disinfected with Braunol (B ...
-
bioRxiv - Neuroscience 2021Quote: ... A 40-mm-long PTFE tubing (ID 300 μm, OD 760 μm) was then attached to a 26 gauge nanosyringe needle (World Precision Instruments) using a heat shrinkable tubing ...
-
bioRxiv - Neuroscience 2021Quote: ... a 28 gauge microfil (World Precision Instruments) was used to load 7 μl of colored saline into the nanosyringe ...
-
bioRxiv - Neuroscience 2021Quote: ... titer: 8-10 × 1012) as described previously by using a beveled needle nanosyringe (nanofil 34G BVLD, WPI) under control of a micro injection pump (100 nl/min ...
-
bioRxiv - Neuroscience 2021Quote: ... under control of a micro injection pump (100 nl/min, WPI) 4.
-
bioRxiv - Neuroscience 2021Quote: ... 400 nl of AAV were delivered using an UltraMicroPump (World Precision Instruments, Sarasota, FL). Dorsal striatum was targeted in neonates by directing the needle +0.1 mm anterior of bregma ...
-
bioRxiv - Neuroscience 2021Quote: ... over the left hemisphere to protect the skull and covered the exposed skull with a silicone elastomer (Kwik-Cast, World Precision Instruments) if there were no other additional procedures after head-plate implantation.
-
bioRxiv - Neuroscience 2021Quote: ... GAD-GFP (Tamamaki et al., 2003) or Vgat-IRES-Cre (Vong et al., 2011) mice using a nanoinjector (Nanoliter 2000, WPI) connected to a glass pipette (~20 um diameter ...
-
bioRxiv - Neuroscience 2021Quote: ... The injection was performed with the pipette connected to a Nano-liter Injector 201 (World Precision Instruments, Inc.) at a slow flow rate of 0.15 μl / min to avoid potential damage to local brain tissue ...
-
bioRxiv - Cancer Biology 2021Quote: Brains were collected into ice-cold HBSS media and dissected into 1mm coronal sections using a brain matrix as above (WPI, RBMS-200C). The following regions were isolated under fluorescence guidance ...
-
bioRxiv - Cancer Biology 2021Quote: ... brains containing tumours were collected and dissected into 1 mm coronal sections using a brain matrix (WPI, RBMS-200C). The tumour bulk and invasive tumour front migrating into the striatum (margin ...
-
bioRxiv - Cell Biology 2021Quote: ... larvae were anesthetized with 0.2 mg/mL Tricaine in E3 and positioned dorsally against the side of grooves made by a mold (World Precision Instruments) in 1% low-melt agarose.
-
bioRxiv - Cell Biology 2021Quote: ... 0.075 × 106 FHIP2A KO U2OS cells stably expressing FHIP2A-TagRFPT-V5 were plated into a 35mm glass bottom FluoroDish with 23mm well (World Precision Instruments) and grown for 24 hours ...
-
bioRxiv - Cell Biology 2021Quote: ... Larval brain explants were placed in lysine-coated 35 mm cover slip dishes (WPI) containing modified minimal hemolymph-like solution (HL3.1) ...
-
bioRxiv - Biophysics 2021Quote: ... ruIs57[unc-119(+) pie-1::GFP::tubulin]) young adult hermaphrodites using needles pulled from borosilicate glass capillaries (World Precision Instruments,1.0 mm OD, 0.58 mm ID, with filament) with a P-87 micropipette puller (Sutter Instrument) ...
-
bioRxiv - Cell Biology 2021Quote: TEER measurements were carried out using an EVOM2 Voltometer (World Precision Instruments) with STX2 chopstick electrodes ...
-
BRD2 inhibition blocks SARS-CoV-2 infection by reducing transcription of the host cell receptor ACE2bioRxiv - Cell Biology 2021Quote: ... The TEER was then measured using an Evom3 ohmmeter (World Precision Instruments).
-
bioRxiv - Cell Biology 2021Quote: ... was maintained at 37±0.2 °C by an Air-Therm heater controller (World Precision Instruments). Vibration isolation was achieved by a TS-150 active anti-vibration table (HWL Scientific Instruments Gmbh).
-
bioRxiv - Cell Biology 2021Quote: ... Borosilicate patch pipettes (WPI, Sarasota, FL) were pulled to resistances of 5 - 8 MΩ (P-2000 ...
-
bioRxiv - Cell Biology 2021Quote: ... Bone slices were placed on a FluoroDish (WPI FD35-100) with cells facing down and immersed with RPMI without phenol red ...
-
bioRxiv - Cell Biology 2021Quote: ... and grown with daily media changes until the transepithelial resistance reached 400 ohm/cm2 (4–5 days) measured with an EVOM electrometer (World Precision Instruments, Sarasota, FL).
-
bioRxiv - Cell Biology 2021Quote: ... was measured using an EVOM2 Volt Ohm Meter (World Precision Instruments, Sarasota, FL). The resistance of cell-free collagen-coated filters was subtracted from each experimental point ...
-
bioRxiv - Pharmacology and Toxicology 2021Quote: ... the cells were approached with micropipettes of 1.2-3.3 MΩ resistance manufactured from 1.5 mm OD glass (World Precision Instruments, Sarasota, Florida, USA) on a microelectrode puller ...
-
bioRxiv - Physiology 2021Quote: Pronuclei of one-cell stage embryos were collected from superovulated donor females (B6/SJL strain) and microinjected with CRISPR/Cas9 constructs using micromanipulators and injection needles (World Precision Instruments, filament #1B100-6). Injected embryos were implanted into pseudopregnant recipient females according to NIH guidelines ...