Labshake search
Citations for World Precision Instruments :
2251 - 2300 of 3820 citations since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2021Quote: ... for lesion visualization was inserted into the brain parenchyma (Z −1.4mm) using a micromanipulator (Nanoliter 2000, World Precision Instruments). 1 μl was injected with a flow rate of 100 nl/min ...
-
bioRxiv - Neuroscience 2021Quote: ... we pulled 6 to 10 M-Ohm glass pipettes made of thick-walled glass (World Precision Instruments 1B150F-3) using a Sutter Instruments P-1000 puller ...
-
bioRxiv - Neuroscience 2021Quote: ... Approximately 1 μL of virus contained in a pulled-glass pipette was pressure injected into the cortex at two depths (~200 μm and 400 μm below the surface) over 20 min using a Nanoject-II (World Precision Instruments). The craniotomy was filled with 2% agarose and sealed with a thin sterile plastic film to prevent dural adhesion.
-
bioRxiv - Neuroscience 2021Quote: ... Short pulses (0.1 ms) were applied using an A365 stimulus isolator (World Precision Instruments) to evoke monosynaptic responses ...
-
bioRxiv - Neuroscience 2021Quote: ... first with silicon elastomer (Kwik-Sil, World Precision Instruments) and then with dental acrylic (C&B-Metabond ...
-
bioRxiv - Neuroscience 2021Quote: ... Odorants were delivered by displacing a 0.1L/min of headspace in the odor bottles using a pneumatic picopump (WPI Inc., PV-820). Each odor pulse was 4 s and the inter-trial interval was 60 s.
-
bioRxiv - Neuroscience 2021Quote: ... we switched from solid food reward (grass) to liquid food reward (sucrose in water) and presented it in an automated manner using a pneumatic pump (WPI Inc., PV-820). The intertrial interval was set to 3 minutes for the training phase ...
-
bioRxiv - Neuroscience 2021Quote: ... and the craniotomy was protected by a silicone elastomer (Kwik-Cast, WPI). The mouse was allowed to recover from the anesthesia in home cage for at least 2 hours ...
-
bioRxiv - Neuroscience 2021Quote: ... The array was positioned above the dura and sealed by Silastic (Qwik-Sil, WPI) and fixed by dental acrylic ...
-
bioRxiv - Neuroscience 2021Quote: ... Gentle pressure was applied to the cover glass while Kwik-Sil adhesive (World Precision Instruments, Inc.) was deposited to bond the glass to the skull ...
-
bioRxiv - Neuroscience 2021Quote: ... A 4 mm round #1.5 cover glass (World Precision Instruments, Inc.) was placed over the exposed brain with artificial cerebrospinal fluid filling the void ...
-
bioRxiv - Neuroscience 2021Quote: ... transendothelial electrical resistance (TEER) was measured using STX2 chopstick electrodes and an EVOM2 voltameter (World precision Instruments) approximately every 24 hours ...
-
bioRxiv - Neuroscience 2021Quote: ... Recording pipettes were pulled from glass capillaries (1B150F-4, WPI) to have a ∼20 μm opening ...
-
bioRxiv - Neuroscience 2021Quote: ... The exposed skull above the future craniectomy site was covered with Kwik-Cast (WPI). Following surgery ...
-
bioRxiv - Cell Biology 2021Quote: ... A glass micropipette (#1B100-4, World Precision Instruments, Sarasota, USA) was forged to a diameter smaller than the average protoplast radius (∼2.5 µm) ...
-
bioRxiv - Neuroscience 2021Quote: ... was injected at three different depths (1100, 1350 and 1500 µm DV) with a micro-syringe pump controller (Micro4, World Precision Instruments) operating at a rate of 50 nl/min and a 10 µl Hamilton syringe ...
-
bioRxiv - Neuroscience 2021Quote: ... 0.7-1.0 μl of AAV was injected into the dorsal hippocampi using a glass pipette (tip diameter 7∼10 μm) at a rate of 100 nl/min using a syringe pump (Micro2T; World Precision Instruments). We injected each AAV with the following titer per hippocampus ...
-
bioRxiv - Neuroscience 2021Quote: ... A Nanofil syringe (World Precision Instruments) with a 34 G beveled needle was filled with virus suspension (or mixture of viruses ...
-
bioRxiv - Neuroscience 2021Quote: ... Constant current stimuli (0.5 μA-5 mA) were applied using a high-voltage stimulus isolator (A365R, World Precision Instruments, Sarasota, FL). The evoked mono and polysynaptic IPSCs were recorded simultaneously in GCs and SGC pairs ...
-
bioRxiv - Neuroscience 2021Quote: ... or AAV8-TRE3G-Kir2.1-YFP was injected bilaterally using a 31 gauge stainless steel needle (#22031-01, Hamilton Co., Reno, NV) attached to a microsyringe injector (#UMC4, World Precision Instruments, Sarasota, FL). The needle was slowly lowered to DV −3.2 mm and remained in place for 10 min after the injection ...
-
bioRxiv - Neuroscience 2021Quote: ... We infused the neurotracers via a 10 µl NanoFil syringe (blunt tip, 33-gauge needle; World Precision Instruments, Sarasota, FL, USA) at a rate of 0.05 µl / minute using a micro-infusion pump (Stoelting ...
-
bioRxiv - Neuroscience 2021Quote: ... at a rate of 50 nL/s using a microinjector (Micro4; World Precision Instruments) and a glass pipette (Drummond Scientific) ...
-
bioRxiv - Neuroscience 2021Quote: ... Electrical stimulation was driven using a fully isolated current source (battery powered with an optically coupled trigger, A365RC, World Precision Instruments) with the source and sink terminals connected to the adjacent strands of the pair of stainless steel wires forming the stimulation electrode ...
-
bioRxiv - Neuroscience 2021Quote: ... Silicon adhesive (WPI Kwik-Sil) was applied to the exposed brain surface ...
-
bioRxiv - Neuroscience 2021Quote: ... mice were anesthetized with isoflurane (induction, 5%; maintenance, 0.5 to 1.5%) and placed into a stereotaxic frame (World Precision Instruments). The body temperature was maintained at 36° C using a heating pad ...
-
Emerging experience-dependent dynamics in primary somatosensory cortex reflect behavioral adaptationbioRxiv - Neuroscience 2021Quote: ... The skull was covered with a silicone elastomer (Kwik-Cast Sealant World Precision Instruments) between imaging sessions for protection ...
-
Emerging experience-dependent dynamics in primary somatosensory cortex reflect behavioral adaptationbioRxiv - Neuroscience 2021Quote: ... and the silicone elastomer Kwik-Cast (Kwik-Cast Sealant World Precision Instruments), for protection ...
-
bioRxiv - Neuroscience 2021Quote: ... using a picospritzer (World Precision Instruments, FL, USA) and glass micropipettes (25-50 μm inner diameter) ...
-
bioRxiv - Neuroscience 2021Quote: ... Injection volumes were 500 nl delivered at 10 nl / min using a metal gauge needle attached to a NanoFil© 10 µL syringe (World Precision Instruments). The needle was positioned at the first target site and remained there for 10 min before the beginning of the injection ...
-
bioRxiv - Neuroscience 2021Quote: ... NJ) was aspirated into a borosilicate glass capillary tube (TW150, World Precision Instruments, Sarasota, FL). Electrodes were then pulled using a pipette puller and cut so that 100-150 μm of carbon fiber protruded from the tip of the glass ...
-
bioRxiv - Neuroscience 2021Quote: ... with 0.1 mA steps) generated by a stimulator equipped with a stimulus isolation unit (World Precision Instruments, Inc.). The effect of GABAAR activation was investigated by bath application of 2 μM Diazepam (GABAAR agonist) ...
-
bioRxiv - Neuroscience 2021Quote: ... we used a micromanipulator (World Precision Instruments) and a Hamilton injection system (syringe ...
-
bioRxiv - Molecular Biology 2021Quote: ... The endogenous H2S content was detected using a novel polarographic H2S sensor (WPI, TBR4100, Sarasota, FL, USA). Briefly ...
-
Efficient Suppression of Endogenous CFTR Nonsense Mutations Using Anticodon Engineered Transfer RNAsbioRxiv - Molecular Biology 2021Quote: ... Cells were grown until the formation of electrically tight epithelial monolayer was confirmed by measuring transepithelial resistance with EVOM2 Epithelial Voltohmmeter (World Precision Instruments, Sarasota, FL, USA). Short circuit current (Isc ...
-
bioRxiv - Biophysics 2021Quote: ... Borosilicate glass tubes (inner diameter: 0.68 mm, outer diameter: 1.2 mm; World Precision Instruments) were pulled into closed capillaries in a two-step program using a squared box filament (2.5 mm × 2.5 mm ...
-
bioRxiv - Neuroscience 2021Quote: ... The surface was covered by silicon elastomer (Kwik-Sil, WPI) to protect the craniotomy until the recording ...
-
bioRxiv - Microbiology 2021Quote: ... all potential substrates were pre-injected at 25 nl/oocyte using a Micro4TM micro-syringe and A203XVY nanoliter injector (World Precision Instruments). Oocytes were then incubated on ice for 30 mins prior to uptake experiments to allow for membrane recovery ...
-
bioRxiv - Microbiology 2021Quote: ... cRNA was micro-injected into stage 5 or 6 oocytes using a Micro4TM micro-syringe pump controller and A203XVY nanoliter injector (World Precision Instruments, Sarasota, FLA, U.S.A.). Oocytes were maintained in oocyte Ringer’s buffer with added gentamycin (50 μg/ml ...
-
bioRxiv - Microbiology 2021Quote: ... The Em of oocytes was recorded in unclamped mode using conventional boronsilicate glass microelectrodes capillaries (World Precision Instruments) filled with 3 M KCl to a resistance of 5-10 MΩ ...
-
bioRxiv - Neuroscience 2021Quote: ... A small amount of Kwik-Sil (World Precision Instruments, Inc., Sarasota, FL) was then placed over the cut ends of the nerves to prevent crystals from diffusing from the intended labeling site ...
-
bioRxiv - Neuroscience 2021Quote: ... 300 µm transverse slices were cut with a tissue chopper (WPI McIlwain), then positioned on 0.45 µm Durapore membranes on Millicell culture inserts (Millipore ...
-
bioRxiv - Neuroscience 2021Quote: ... attached to a 36-gauge needle and an UltraMicroPump (WPI) mounted to a stereotaxic arm ...
-
bioRxiv - Neuroscience 2021Quote: ... Viral injections were made with a NanoFil (WPI) attached to a 36-gauge needle and an UltraMicroPump (WPI ...
-
bioRxiv - Microbiology 2021Quote: ... and urea were measured using a high-sensitivity colorimetric approach with an AutoAnalyzer II (Technicon) and Liquid Waveguide Capillary Cells (World Precision Instruments, USA) as outlined (51) ...
-
bioRxiv - Neuroscience 2021Quote: ... using a beveled glass pipette (tip diameter ∼20 - 40 μm) on a micro injector UMP3 with a Micro4 controller (World Precision Instruments). The injector was mounted on a micromanipulator (Luigs & Neumann ...
-
bioRxiv - Neuroscience 2021Quote: ... the window was sealed with biocompatible silicone sealant until the recording session (World Precision Instruments, Kwik-Cast).
-
bioRxiv - Neuroscience 2021Quote: ... Current injections were delivered by a stimulus isolator (World Precision Instruments) under control of a TTL output from AxographX software ...
-
bioRxiv - Neuroscience 2021Quote: Borosilicate glass patch pipettes (World Precision Instruments) were pulled to a resistance of 4–6 MΩ for eTCs ...
-
bioRxiv - Evolutionary Biology 2021Quote: ... on NBM medium in incubator at 37°C for at least 2h recovery before being placed in a Fluorodish (WPI) for imaging ...
-
bioRxiv - Neuroscience 2021Quote: NO efflux from cerebellar slices was monitored using a NO-selective amperometric microprobe with a 7 μm tip (WPI), similar to previous work (37) ...