Labshake search
Citations for World Precision Instruments :
1101 - 1150 of 3820 citations since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Bioengineering 2023Quote: ... 14- and 21-day old live 3D co-culture models were transferred to 35mm fluorodishes (WPI, FD35-100) containing phosphate-buffered saline (PBS ...
-
bioRxiv - Cell Biology 2023Quote: Live imaging was performed in glass-bottomed 35 mm FluoroDishes (WPI) in FluoroBrite DMEM medium (ThermoFisher) ...
-
bioRxiv - Biophysics 2023Quote: ... the embryos were transferred to a glass bottom Petri dish (WPI, Sarasota, FL, USA) filled with 0.75x Egg salt with a drop of SGM ...
-
bioRxiv - Cell Biology 2023Quote: ... The micropipette was bent to a desired degree by heating it over an alcohol lamp and was filled with phosphate-buffered saline (PBS) using the MicroFil (World Precision Instruments, MF34G-5). The micropipette was installed to a micropipette holder ...
-
bioRxiv - Neuroscience 2023Quote: ... The virus (AAV1/2-OXTp-hM4Dgi-mCherry or AAV1/2-OXTp-Venus or AAV1/2-OXTp-mCherry) was loaded into a 20μl NanoFil syringe fitted with a 33gauge needle (cat no. NF33BL, World Precision Instruments Inc, Sarasota, FL, USA). A final volume of 270nl was injected into the PVH (A-P −1.7mm ...
-
bioRxiv - Biophysics 2023Quote: Micropipettes were formed by pulling glass capillaries (World Precision Instruments Inc.) with a pipette puller (Sutter Instruments ...
-
bioRxiv - Biophysics 2023Quote: ... electrical field stimulation was applied via the bipolar electrode that was connected to a high current stimulus isolator (WPI, A385) and Master 8 (A.P.I ...
-
bioRxiv - Biophysics 2023Quote: ... using a Sutter P-97 puller and heat-polished to final resistances between 0.5 and 4 MΩ using a MF-200 microforge (World Precision Instruments). 90% series resistance (Rs ...
-
bioRxiv - Cell Biology 2023Quote: ... and a PV820 microinjector (World Precision Instruments) coupled to a spinning disk confocal microscope ...
-
bioRxiv - Cancer Biology 2023Quote: ... with a chopstick electrode (STX3, World Precision Instruments). Measures were made before radiation and pre-treatments ...
-
bioRxiv - Cell Biology 2023Quote: ... on a FluoroDish (FD35-100, WPI) and incubated in the dark overnight at room temperature to allow the mounting medium to harden ...
-
bioRxiv - Cell Biology 2023Quote: ... glass bottom dishes (World Precision Instruments) or no ...
-
bioRxiv - Cancer Biology 2023Quote: ... and the cells were injected at the position 2 mm to the right lateral bregma and 3 mm deep with a flow of 0.2 μL/min utilizing a 10 μL precision micro syringe (World Precision Instruments, Florida, USA) with a 34-gauge needle ...
-
bioRxiv - Biophysics 2023Quote: Micropipettes were forged by pulling glass capillaries (World Precision Instruments TW100-3) using a P-97 Flaming Brown needle puller (Sutter Instrument ...
-
bioRxiv - Cancer Biology 2023Quote: TEER in monolayer of HAL and HuAST plated on cell culture inserts was measured using a voltohmmeter (EVOM2, World Precision Instruments) with a chopstick electrode (STX3 ...
-
bioRxiv - Cancer Biology 2023Quote: ... A suspension of 100,000 cells/2 µl/injection was then slowly injected using an UltraMicroPump III and a Micro4 Controller (World Precision Instruments). Post-surgical pain was controlled with SQ carprofen ...
-
bioRxiv - Cancer Biology 2023Quote: ... The animal was placed in a heated chamber maintained at physiological temperatures by a forced-air heater (WPI Inc., AirTherm ATX), during the course of imaging and the animals were maintained at 0.75-1.5% isoflurane for the duration of imaging ...
-
bioRxiv - Genetics 2023Quote: ... to pull 4-inch long thin wall filamented glass capillary tubes (TW100F-4, World Precision Instruments, Sarasota, FL) into injection needles using custom settings ...
-
bioRxiv - Developmental Biology 2023Quote: ... was injected through the uterine wall into the telencephalic vesicle using pulled borosilicate needles (WPI). For gain-of-function experiments ...
-
bioRxiv - Immunology 2023Quote: ... mice were placed on a heating pad (World Precision Instruments) maintained at 37° C ...
-
bioRxiv - Cell Biology 2023Quote: ... Microscope temperature was maintained at 30°C using a custom-made chamber and a heater (Air-Therm ATX, World Precision Instruments). An electronic shutter was used to switch between fluorescence and darkfield illumination ...
-
bioRxiv - Neuroscience 2023Quote: ... The injection was driven at a flow rate of 100 nL/min by a Nanoliter 2020 Injector (World Precision Instruments, Sarasota, FL). The micropipette was left in place for another 5 minutes to allow for tissue diffusion before being retracted slowly ...
-
bioRxiv - Pathology 2023Quote: ... Membrane potential was recorded using an Electro 705 amplifier (World Precision Instruments, Sarasota, FL, USA). Analog output from the amplifier was recorded using Ionwizard software (version 7.5.1.162 ...
-
bioRxiv - Systems Biology 2023Quote: ... These devices were cut out using a scalpel and holes punched using a 0.75mm reusable biopsy punch (World Precision Instruments). PDMS devices were bonded to glass slides using a plasma cleaner (Harris Plasma) ...
-
bioRxiv - Neuroscience 2023Quote: ... The rubber well was then covered with silicone elastomer (Kwik-Cast, World Precision Instruments) until the experiment ...
-
bioRxiv - Neuroscience 2023Quote: ... using 3.0±0.5 MegaOhm glass pipettes (WPI, Inc), pulled with a PC10 puller (Narishige ...
-
bioRxiv - Neuroscience 2023Quote: ... the metal cannula was sealed with a silicone polymer plug (Kwik-kast, World Precision Instruments) to protect the imaging window between imaging experiments ...
-
bioRxiv - Neuroscience 2023Quote: Viral injections were performed using a beveled 33-gauge microinjection needle connected to a 10 μL microsyringe (Nanofil; WPI, Sarasota, FL, USA) at a rate of 100 nL/min using a microsyringe pump (UMP3 ...
-
bioRxiv - Neuroscience 2023Quote: ... at a rate of 100 nL/min using a microsyringe pump (UMP3; WPI) and pump controller (Micro4 ...
-
bioRxiv - Neuroscience 2023Quote: ... and pump controller (Micro4; WPI). After injections were complete ...
-
bioRxiv - Neuroscience 2023Quote: ... The top of the GRIN lens was then covered with a layer of Kwik-Cast (World Precision Instruments) and a final layer of dental acrylic for protection until base plate attachment ...
-
bioRxiv - Animal Behavior and Cognition 2023Quote: ... the craniotomy was sealed with silicone elastomer (Kwik-Sil, World Precision Instruments Inc., USA), and a thin layer of Super-Bond (Sun Medical Co. ...
-
bioRxiv - Neuroscience 2023Quote: ... a low toxicity adhesive (World Precision Instruments, Sarasota, FL) and protected by attaching a plastic cup ...
-
bioRxiv - Biochemistry 2023Quote: ... 1×105 U-2 OS or U-2 OS Flp-In T-Rex cells were seeded in 35 mm glass bottom dishes (FD35-100, WPI); cells were transfected with 1-2 µg of pcDNA5 FRT/TO plasmids containing the gene of interest using GeneJuice transfection reagent (Cat#70967 ...
-
bioRxiv - Neuroscience 2023Quote: ... At least 10 minutes passed following each injection before the pipette was withdrawn and burr holes were filled with KWIK-SIL (WPI). Injections were performed prior to the skull clearing procedure.
-
bioRxiv - Bioengineering 2023Quote: ... Tiny drops of silicone sealant (Kwik-sil, World Precision Instruments) were applied around the coverglass and on the uncovered brain surface ...
-
bioRxiv - Neuroscience 2023Quote: ... and the recordings were obtained by using an ISO-80 amplifier (World Precision Instruments, Hertfordshire, England) and digitized with an ADC-42 system (Pico Technologies ...
-
bioRxiv - Neuroscience 2023Quote: ... and −8.2 mm DV) at a rate of 100 nL/min using a microinfusion pump (UltraMicroPump III, World Precision Instruments, Sarasota, FL, USA) and a 10µL Hamilton syringe (Hamilton ...
-
bioRxiv - Neuroscience 2023Quote: ... The microinjection cannula was connected by PE-50 tubing to a Hamilton syringe mounted on a syringe pump (World Precision Instruments, FL. USA). Rats were microinjected with either pEGFP-N1 plasmid expressing full-length rat FGF-AS gene or in vivo JetPEI mix ...
-
Serotonergic Modulation of Spinal Circuitry Restores Motor Function after Chronic Spinal Cord InjurybioRxiv - Neuroscience 2023Quote: ... The junction was secured using 4-0 silk suture and liquid silicone (World Precision Instruments, Kwik-Sil). Note that an additional small incision was made above the cannula-implant site to expose the proximal (or silicone ...
-
bioRxiv - Neuroscience 2023Quote: E-prime programs (Psychology Software Tools) controlled the task as well as the delivery of liquid rewards via a syringe pump (SP210iw; World Precision Instruments). Liquids from two 60-ml plastic syringes mounted on the pump were merged into one tube and then delivered to the participant’s mouth through a silicon tube (Movie S1).
-
bioRxiv - Neuroscience 2023Quote: ... The incision was secured to the skull with application of cyanoacrylate (VetBond; World Precision Instruments), and the 3D-printed recording chamber was attached to the skull with L-type radiopaque polymer (Super-Bond C&B) ...
-
bioRxiv - Neuroscience 2023Quote: ... 2A-C which used 10-60 μA) were generated by triggering a stimulus isolator (World Precision Instruments, Sarasota, Florida) and applied via fire-polished ...
-
bioRxiv - Neuroscience 2023Quote: ... Dental cement (Parkell, NY) sealed a glass coverslip (3mm) over a drop of Kwik Sil (World Precision Instruments, FL) over the craniotomy ...
-
bioRxiv - Neuroscience 2023Quote: ... the vagus nerve was mechanically stabilized on the micro-cuff electrode by applying a drop of 2-component silicone (Kwik-Sil, World Precision Instruments, Sarasota, FL) and then sectioned either caudal or rostral to the cuff ...
-
bioRxiv - Neuroscience 2023Quote: ... and protected by Kwik-Sil (WPI, Sarasota, FL). The skull was covered with dental cement (Grip Cement ...
-
bioRxiv - Neuroscience 2023Quote: ... mice were injected in layer 5 of the visual cortex using a microinjection pump (WPI Ltd., USA), 5□µl Hamilton syringe (Esslab Ltd. ...
-
bioRxiv - Neuroscience 2023Quote: ... The gap between the lens and the skull was filled using Kwik-Sil (World Precision Instruments), superglued ...
-
bioRxiv - Developmental Biology 2023Quote: ... The spinal cord was transected with a microblade (WPI#501731 or WPI#500249) at the level of the cloaca ...
-
bioRxiv - Developmental Biology 2023Quote: ... The spinal cord was transected with a microblade (WPI#501731 or WPI#500249) at the level of the cloaca ...