bioRxiv - Systems Biology 2023Quote: ... The inlet and outlet holes were punched with a 0.75 mm biopsy puncher (World Precision Instruments). The PDMS chips were sonicated in isopropyl alcohol (Fisher Scientific ...
-
bioRxiv - Neuroscience 2023Quote: ... The animal was placed in a stereotaxic frame (WPI) and over a heating blanket to maintain normothermia during procedures ...
-
bioRxiv - Cell Biology 2023Quote: C2C12 cells were seeded on FluoroDish (WPI, France) cell culture dishes overnight ...
-
bioRxiv - Molecular Biology 2023Quote: ... cells were grown on 35 mm FluoroDish (World Precision Instruments) with 0.17 mm thick optical quality glass bottom and fitted with a 4-well silicone insert (Ibidi) ...
-
bioRxiv - Neuroscience 2023Quote: ... and the recording chamber was sealed with Qwik-sil silicone (World Precision Instruments) to facilitate multiple recording sessions ...
-
bioRxiv - Neuroscience 2023Quote: ... and a total volume of 100 nl was administered at a rate of 50 nl/min using a micropump (Micro4, WPI, Sarasota, FL). To prevent any fluid reflux ...
-
bioRxiv - Neuroscience 2023Quote: ... Glass coverslip held in place with Vetbond and Kwik-Cast (World Precision Instruments) until the day of the recording (several weeks later) ...
-
bioRxiv - Neuroscience 2023Quote: ... A total volume of 0,5 ul of the virus was injected at a controlled rate of 0.1 µl min−1 using a microinjector (WPI, Sarasota, USA) The pipette was slowly lowered to the target site and remained in place for another 5 min post-injection before being slowly withdrawn ...
-
bioRxiv - Neuroscience 2023Quote: ... The right femoral artery was cannulated for continuous recording of mean arterial blood pressure (MAP) and heart rate (fH) using a BP-1 system (WPI Inc., Sarasota, FL, USA) and for monitoring of arterial blood pH ...
-
bioRxiv - Neuroscience 2023Quote: ... Whole-cell patch clamp recordings were obtained with glass pipette electrodes pulled from borosilicate capillaries (World Precision Instruments, Sarasota, FL) on a P97 Flame/Brown Puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2023Quote: ... Body temperature was monitored by a rectal thermometer (RET-3, WPI, Germany) and kept constant by using a heating mat (MediHeat ...
-
bioRxiv - Neuroscience 2023Quote: ... and kept constant by using a heating mat (MediHeat, V1200) and temperature control device (ATC2000-220, WPI, Germany). After reaching surgical tolerance ...
-
bioRxiv - Neuroscience 2023Quote: ... 1.5 cm centrally along the skull bone and craniotomy was performed with a micro drill system (#503599, WPI, Germany) above the target regions ...
-
bioRxiv - Neuroscience 2023Quote: ... Motoneurons were visualized and whole-cell recordings obtained under DIC using pipettes (L: 100 mm, OD: 1.5 mm, ID: 0.84 mm; World Precision Instruments) pulled on a Flaming Brown micropipette puller (Sutter instruments P97 ...
-
bioRxiv - Neuroscience 2023Quote: ... from borosilicate glass (1B200-4, WPI, Sarasota, FL). Pipettes for somatic recording had an impedance of 5-6 MΩ ...
-
bioRxiv - Neuroscience 2023Quote: ... The GRIN lens was protected by a cut-off tip of an Eppendorf tube (Fisher) that was secured using Kwik-Cast (WPI).
-
bioRxiv - Neuroscience 2023Quote: ... UK) and attached to a 100 µl glass Hamilton syringe driven by a microinfusion pump (sp210iw syringe pump, World Precision Instruments, US) was filled with low molecular weight fluorescent tracer ...
-
bioRxiv - Neuroscience 2023Quote: ... Micro4 (World Precision Instruments), at 15 nL per min ...
-
bioRxiv - Neuroscience 2023Quote: ... and controller (Micro2T; World Precision Instruments). After completion of the injections ...
-
bioRxiv - Neuroscience 2023Quote: ... The brains were partitioned into a set of 11 structures using a microsurgical knife (MSP Stab Knife Straight REF 7503, Surgical Specialties) and tweezers (Dumont #5B, World Precision Instruments). Structures in all brains were dissected in the same order ...
-
bioRxiv - Cancer Biology 2023Quote: ... The labeled MDA-MB-231 cell suspension was loaded into a pulled glass capillary and 1-2 nl were micro-injected into the blood circulation of Tg(osx:mCherry) zebrafish embryos via the duct of Cuvier (DoC) using a pneumatic PicoPump (SYS-PV820, WPI, Sarasota, USA). Engrafted embryos were maintained in a new petri dish at 33 °C (26) ...
-
bioRxiv - Cancer Biology 2023Quote: ... Glass needles for injection were pulled from glass capillaries with filament (TW100F-3, WPI) with a P-97 Flaming/Brown micropipette puller (Sutter Instrument Co.) ...
-
bioRxiv - Neuroscience 2023Quote: ... cells were patched using 4-6 MΩ resistant borosilicate pipettes (1B100F-4, World Precision Instruments, USA). Pipettes were pulled by micropipette puller P-1000 (Sutter ...
-
bioRxiv - Neuroscience 2023Quote: Patch electrodes of 5-7 MΩ resistance (thin wall, filament, 1.5 mm, WPI, Florida, USA) were pulled on DMZ Zeitz-Puller (Zeitz-Instruments Vertriebs GmbH ...
-
bioRxiv - Neuroscience 2023Quote: ... and then by silicon based elastomer (Kwik-cast, WPI) that was easily removed just before recording sessions.
-
bioRxiv - Neuroscience 2023Quote: ... opaque biocompatible silicone (Kwik-Cast, WPI). Mice recovered for at least 5 days following rAAV injection and/or headpost implantation ...
-
bioRxiv - Neuroscience 2023Quote: ... A glass micropipette (5-10 µm outer diameter tip) attached to a nanoinjector (WPI) was used to deliver the viral vector (at 20-50 nL/min) ...
-
bioRxiv - Neuroscience 2023Quote: ... the cranial window had a rectangular laser-cut opening (0.30 x 0.80 mm, Potomac Photonics, Fig. 2a) covered with transparent biocompatible silicone (Kwik-Sil, WPI)76 ...
-
bioRxiv - Physiology 2023Quote: ... band-pass filtered (10Hz–1kHz) (ISO Dam, WPI, UK) and sampled (at 2kHz ...
-
bioRxiv - Neuroscience 2023Quote: ... and rAAV5-EF1α-DIO-ChR2(H134R)-EYFP (3.2 x 1012 VM/mL) were unilaterally administered into the right side of the VMH of mice using a UMP3 UltraMicroPump (WPI, US) with 10 µL NanoFil microsyringe (WPI ...
-
bioRxiv - Neuroscience 2023Quote: ... and 35G NanoFil beveled needle (WPI; Catalog# NF35BV-2). The volume of AAVs was 500-1000 nL at the rate 50-100 nL per minute ...
-
bioRxiv - Neuroscience 2023Quote: ... The spout was connected by tubing to a 10 ml syringe filled with water and secured in a single-syringe infusion pump (AL-1000, World Precision Instruments). The pump was located outside of the box ...
-
bioRxiv - Neuroscience 2023Quote: ... A water pump (AL-1000, World Precision Instruments) and sound presentation were controlled by a custom-written LabVIEW program (National Instruments) ...
-
bioRxiv - Neuroscience 2023Quote: ... Craniotomy site was covered with a biocompatible sealant (Kwik-Sil, World Precision Instruments). During the recording sessions ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... An extracellular amplifier (DAM80, World Precision Instruments) was used to record the mouse ECG (gain 100x ...
-
bioRxiv - Physiology 2023Quote: ... The glass microelectrodes were fashioned from 1 mm borosilicate glass capillaries (1B100F-4, World Precision Instruments, Sarasota, FL, USA) pulled to a tip resistance of 5-7 MΩ in a Flaming-Brown P-1000 micropipette puller ...
-
bioRxiv - Cell Biology 2023Quote: ... equipped with a Nanofil syringe (World Precision Instruments). For ex vivo mGluR5 genetic knockout slices ...
-
bioRxiv - Molecular Biology 2023Quote: ... The nerve was crushed for three seconds using self-closing forceps (Dumoxel, World Precision Instruments, Sarasota, FL). Erythromycin ophthalmic ointment USP ...
-
bioRxiv - Microbiology 2023Quote: ... The coverslip-pad-cell sample assembly was placed inverted onto the base of a 35 mm #1.5 FluoroDish (WPI)45 ...
-
bioRxiv - Physiology 2023Quote: ... incisions using dissection scissors (Cat# 500086, World Precision Instruments Inc) were made to release the ventral abdomen from the rest of the fly body ...
-
bioRxiv - Physiology 2023Quote: ... Both glass and reference electrodes were connected to a Duo 773 two-channel intracellular/extracellular amplifier (World Precision Instruments, Sarasota, FL, USA), and the output was digitized with a PowerLab 4SP A/D converter (ADInstruments ...
-
bioRxiv - Physiology 2023Quote: ... see below) was measured using an Apollo 1000 Free Radical analyser with an ISO-NOPF100 NO microsensor (1 mm) (World Precision Instruments, USA). The sensor was calibrated with S-nitroso-N-Acetyl-D,L-Penicillamine (Toronto Research ...
-
bioRxiv - Neuroscience 2023Quote: ... were pressure-injected into caudate nucleus (Interaural 9.75 mm) and putamen (Interaural 9.75 mm) by Hamilton syringe mounted into motorized microinjector (UMP3T-2, WPI) held by manipulator (Model 1460 ...
-
bioRxiv - Neuroscience 2023Quote: ... was used for pulling recording electrodes with micropipettes (World Precision Instruments). The electrodes had resistance of 3-5 MΩ ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... SM preparations were fixed between a stationary stainless steel hook and an isometric force transducer (AE 801, SensoNor A/S, Norten, Norway) coupled to an AD converter Lab-Trax 4/16 (World Precision Instruments, Inc., Sarasota, FL, USA). The data were continuously recorded using DataTrax2 (World Precision Instruments ...
-
bioRxiv - Neuroscience 2023Quote: ... Opaque silicone elastomer (Kwik-Cast, World Precision Instruments) was used to cover the craniotomy after surgery and between recording sessions ...
-
bioRxiv - Neuroscience 2023Quote: ... A small craniotomy overlying motor cortex was then performed using a hand-held microdrill (WPI) under constant cooling with sterile phosphate buffered saline and visualisation through a surgical microscope (Leica) ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... The data were continuously recorded using DataTrax2 (World Precision Instruments, Inc., Sarasota, FL, USA).
-
bioRxiv - Neuroscience 2023Quote: ... A moisturising sealant was applied over the dura (typically DuraGel (Cambridge NeuroTech) covered with a layer of Kwikcast (World precision instruments)) ...
-
bioRxiv - Neuroscience 2023Quote: ... Drug was perfused to the cortical surface through an infusion pump (Micro4, World Precision Instruments) at a rate of 0.5 μL/min (2 μL volume in total) ...