Labshake search
Citations for Illumina :
201 - 250 of 669 citations for 1 1 Dimethylsila 11 Crown 4 since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Evolutionary Biology 2020Quote: ... They were sequenced at the University of Missouri core facility (Illumina, SE 1 x 50 bp). T ...
-
bioRxiv - Cancer Biology 2021Quote: ... Concurrently 1 ug total RNA was prepped for RNA sequencing according to the manufacturer’s instructions (Illumina). Analysis was performed as described previously1 ...
-
bioRxiv - Microbiology 2020Quote: ... 1 ng of DNA was used to create Nextera XT libraries according to manufacturer’s instructions (Illumina).
-
bioRxiv - Immunology 2021Quote: ... Add 30 μl PCR master mix (2.5 μl Illumina dual indexes primer 1, 2.5 μl Illumina dual index primer 2 ...
-
bioRxiv - Genomics 2021Quote: ... About 320 million paired-end raw reads were generated for AGENOME-ZPMS-HV2a-1 by Illumina sequencing.
-
bioRxiv - Immunology 2023Quote: ... 10% v/v dimethylformamide) containing 1 μl Tagment DNA Enzyme (Nextera DNA Sample Prep Kit (Illumina)) ...
-
bioRxiv - Molecular Biology 2023Quote: ... 1 µl of the forward and reverse fusion primers (10 µM; including Illumina sequencing adapters; SI6), 2 µl of the cleaned-up PCR product ...
-
bioRxiv - Cancer Biology 2024Quote: ... 1 μg of RNA was used for library preparation with Truseq Stranded Total RNAseq kit (Illumina) with rRNA removal and sequenced on Illumina Novaseq 6000 (150 bp paired-end mode ...
-
bioRxiv - Genomics 2024Quote: ... samples were incubated in incorporation mix (MiSeq Nano kit v2 reagent 1) (Illumina MS-103-1003) for 5 minutes at 60 °C on a flat-top thermal cycler ...
-
bioRxiv - Developmental Biology 2024Quote: ... 1 µg of DNAse-treated RNA was treated with RiboZero Gold (Human/Mouse/Rat) kit (Illumina) to remove rRNAs ...
-
bioRxiv - Microbiology 2023Quote: ... and sequenced at Novogene on 1 HiSeq PE 150 lane (6 bp, i7 single index, Illumina). The output of the lane was 375 million reads.
-
bioRxiv - Plant Biology 2024Quote: ... 1 μg of total RNA was processed with the TruSeq Stranded Total RNA LT Kit (Illumina) as follows ...
-
bioRxiv - Molecular Biology 2022Quote: ... 6 pM of DNA library spiked with 1% PhiX viral DNA was clustered on cBot (Illumina) and then sequenced on a HiScanSQ module (Illumina) ...
-
bioRxiv - Genetics 2023Quote: ... and the libraries were subjected to 1 × 7 bp high-throughput sequencing by NextSeq 500 (Illumina).
-
bioRxiv - Bioengineering 2023Quote: ... and samples were sequenced as 1 × 86 bp single-end reads on the NextSeq500 (Illumina, US), yielding on average 42 M reads per sample ...
-
bioRxiv - Microbiology 2024Quote: ... 1 µg of total RNA was processed by Ribo-Zero Magnetic Kit (Bacteria) (#MRZB12424, Illumina, USA). Resulting rRNA-depleted mRNA was phosphorylated by T4 polynucleotide kinase (#M0201 ...
-
bioRxiv - Molecular Biology 2024Quote: ... Single read 1 x 50 bp sequencing of these libraries was performed in HiSeq-2500 (Illumina).
-
bioRxiv - Molecular Biology 2024Quote: ... libraries were prepared using Index Primer Set 1 (NEBNext Multiplex Oligos for Illumina, E7335L, Lot 10172541), Ultra II FS DNA Library Prep Kit for Illumina (E7805L ...
-
bioRxiv - Microbiology 2024Quote: ... A library was prepared independently with 1 μg of total RNA for each sample by Illumina TruSeq Stranded mRNA Sample Prep Kit (Illumina ...
-
bioRxiv - Developmental Biology 2024Quote: ... Libraries were then prepared from 1 ng cDNA using the Nextera XT DNA Library Kit (Illumina). Libraries were sequenced (> 2.107 reads/library ...
-
bioRxiv - Developmental Biology 2021Quote: ... 4 nM 10X scATAC-seq library was sequenced on a NextSeq500 platform (Illumina) using NextSeq 500/550 High Output Kit v2.5 (75 Cycles ...
-
bioRxiv - Developmental Biology 2021Quote: ... 4 nM 10X scRNA-seq libraries were sequenced on a NextSeq500 platform (Illumina) using NextSeq 500/550 High Output Kit v2.5 (150 Cycles ...
-
bioRxiv - Biophysics 2022Quote: ... The sequencing (Step 4) was performed using a Hi-Seq sequencer (Illumina, US) and the data was then filtered using the framing sequence ACAC with a quality score larger then 20 and analyzed (Step 5 ...
-
bioRxiv - Cell Biology 2023Quote: ... 4 ATAC-seq libraries were sequenced per lane in HiSeq 2500 System (Illumina) to generate paired-end 50-bp reads ...
-
bioRxiv - Microbiology 2024Quote: ... DNA from the V3-4 region was amplified using a primer set (Illumina, San Diego ...
-
bioRxiv - Microbiology 2020Quote: ... rRNA was removed from 1 μg of total RNA using Ribo-Zero(TM) rRNA Removal Kit (Illumina). Stranded cDNA libraries were generated using the Illumina Truseq Stranded mRNA Library Prep kit ...
-
bioRxiv - Genetics 2020Quote: ... Sequencing libraries were generated from total RNA (1 ug) using the TruSeq stranded mRNA kit (Illumina Corp.) and were sequenced using a NovaSeq6000 S4 ...
-
bioRxiv - Genomics 2020Quote: Paired-end sequencing libraries (Additional Table 1) were prepared using the TruSeq DNA Sample Prep kit (Illumina) according to the manufacturer’s instructions ...
-
bioRxiv - Microbiology 2020Quote: ... All libraries were diluted to 1 nM and pooled for further sequencing on the MiniSeq platform (Illumina).
-
bioRxiv - Neuroscience 2020Quote: ... Libraries generated with indexing version 134 (Supplementary Table 1) were sequenced on a HiSeq2500 sequencer (RRID:SCR_016383, Illumina) using custom sequencing primers ...
-
bioRxiv - Biochemistry 2020Quote: ... we reduced the false-positive reads introduced by library generation and sequencing steps (Illumina reported at 1%). We detected and discarded on average 5% of reads due to false-positive mutations ...
-
bioRxiv - Microbiology 2022Quote: ... diluted at a ratio of 1:2 and amplified following the Nextera XT Index protocol (Illumina, Inc.). The amplicons were normalized using a SequalPrep™ Normalization Plate Kit (Thermo Fisher Scientific Inc. ...
-
bioRxiv - Genomics 2022Quote: ... We partitioned the genes into three categories: (1) >5-fold higher in Illumina (“Higher count in Illumina”); (2 ...
-
bioRxiv - Microbiology 2020Quote: ... cultures (Supplementary Table 1) using the Epicentre MasterPure DNA Purification kit (Illumina Biotechnology, San Diego, CA, USA) following the manufacturer’s protocol ...
-
bioRxiv - Genomics 2021Quote: ... The libraries were PE150 sequenced on either HiSeqX (Liver nuclei batch 1) or a NovaSeq 6000 (Illumina). scnmC-Seq2 libraries were prepared according to the previously published protocol (Luo et al. ...
-
bioRxiv - Developmental Biology 2021Quote: ... 1 ng of pre-amplified cDNA from an estimated 600 cells was tagmented by Nextera XT (Illumina) with a custom P5 primer (Integrated DNA Technologies) ...
-
bioRxiv - Microbiology 2021Quote: ... rRNA depletion was conducted with 1 μg total RNA using Ribo-Zero rRNA Removal Kit Bacteria (Illumina), followed by library preparation with NEBNext Ultra Directional RNA Library Prep Kit for Illumina (New England Biolabs) ...
-
bioRxiv - Neuroscience 2023Quote: ... Single read (1×75bp) sequencing was performed on the NextSeq 550 platform (Illumina Inc, SY-415-1002) using the NextSeq 500/550 High-Output v2.5 kit (20024906) ...
-
Transcriptional dissection of symptomatic profiles across the brain of men and women with depressionbioRxiv - Neuroscience 2023Quote: ... RNA libraries were synthesized from 1 μg of RNA using the ScriptSeq Complete Gold Kit (Epicentre, Illumina) including an initial ribosomal RNA depletion step ...
-
bioRxiv - Cancer Biology 2023Quote: ... Fixed cells were transposed using barcoded Tn5 (Seqwell) in a transposition buffer (1 × TD buffer from Illumina Nextera kit ...
-
bioRxiv - Cancer Biology 2023Quote: ... The quantified library pool was diluted to 1 nM and sequenced on MiniSeq (Illumina, FC-420-1001) to check for the quality of reads ...
-
bioRxiv - Genomics 2023Quote: ... The libraries were then subjected to 1×75bp high-throughput sequencing using a NextSeq 500 instrument (Illumina). Reads were mapped to the Arabidopsis TAIR10 reference genome using STAR version 2.7.2b (32) ...
-
Autocrine Sfrp1 inhibits lung fibroblast invasion during transition to injury induced myofibroblastsbioRxiv - Cell Biology 2022Quote: ... 1 ng of pre-amplified cDNA from an estimated 1000 cells was tagmented by Nextera XT (Illumina) with a custom P5-primer (Integrated DNA Technologies) ...
-
bioRxiv - Molecular Biology 2024Quote: ... DNA eluted and purified was sequenced (sequencing single-reads, 1 × 50 bp or paired-end 100bp; Illumina) of the resulting input and IP samples performed by BGI ...
-
bioRxiv - Neuroscience 2023Quote: ... and 1 ng of genomic DNA was used for constructing sequencing libraries with the NexteraXT Kit (Illumina). MagSi-NGSPREP Plus Beads (Steinbrenner Laborsysteme GmbH ...
-
bioRxiv - Molecular Biology 2023Quote: ... Libraries were prepared from 1 μg of RNA using the TruSeq Stranded mRNA library prep kit (Illumina) following the reference guide ...
-
bioRxiv - Immunology 2024Quote: ... Beads were resuspended in 29 µL pre-warmed tagmentation buffer with 1 µL Tn5 transpose (Illumina, 20034197). Samples were incubated for 5 minutes with vigorous mixing at 1100 rpm at 37°C in a thermomixer ...
-
bioRxiv - Microbiology 2022Quote: ... and libraries prepared using the NexteraXT kit and sequenced using HiSeq 1 × 150-cycle v3 kit (Illumina). The operational taxonomic unit (OTU ...
-
bioRxiv - Plant Biology 2022Quote: ... 1 µg of total RNA was used as input for the TruSeq sRNA Library Preparation kit (Illumina) as described in the TruSeq RNA Sample Preparation v2 Guide (Illumina) ...
-
bioRxiv - Genomics 2023Quote: ... and used 1 ng for DNA library preparation using the Nextera XT DNA Library Preparation kit (Illumina), according to manufacturer’s protocol ...