Labshake search
Citations for Bioline :
51 - 100 of 377 citations for Parvalbumin PVALB cDNA ORF Clone Mouse N His tag since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2023Quote: ... cDNA was generated using the Tetro cDNA Synthesis Kit (Bioline) and the Uni12 primer (5’-AGCAAAAGCAGG-3’ ...
-
bioRxiv - Cell Biology 2023Quote: ... and cDNA was synthesized using a SensiFast cDNA kit (Bioline) using manufacturer’s instructions from 250 ng of RNA ...
-
bioRxiv - Cell Biology 2024Quote: ... cDNA was generated using Tetro cDNA kit (Bioline BIO-65043), with the following adaptions ...
-
bioRxiv - Cell Biology 2020Quote: ... Quantitative PCR was performed with the SensiFAST SYBR Hi-ROX Kit (Bioline) using a StepOnePlus 96-well plate reader (Applied Biosystems) ...
-
bioRxiv - Microbiology 2023Quote: ... in 20μl reactions using the Sensi FAST Probe Hi-ROX Kit (Bioline) (cycling conditions ...
-
bioRxiv - Genetics 2021Quote: ... cDNA was synthesized using the SensiFast cDNA synthesis kit (Bioline, USA), and qPCR was done using the SYBR green mix (Bio-Rad ...
-
bioRxiv - Genetics 2021Quote: ... cDNA was synthesized using the SensiFast cDNA synthesis kit (Bioline, USA), and qPCR was done using the SYBR green mix (Bio-Rad ...
-
bioRxiv - Cell Biology 2021Quote: ... cDNA synthesis was performed using the Tetro cDNA synthesis kit (Bioline). 2x GoTaq Green master mix (Promega ...
-
bioRxiv - Neuroscience 2020Quote: ... and cDNA synthesis was performed using Tetro cDNA synthesis kit (Bioline). qPCR was carried out on an Applied Biosystems 7900HT Fast Real-Time PCR system using the SYBR Green method using 1 μl cDNA per triplicate ...
-
bioRxiv - Microbiology 2021Quote: ... Libraries of cDNA were created using SensiFAST cDNA Synthesis Kit (Bioline). Control reactions without reverse transcriptase were conducted to confirm the absence of contaminating DNA in all samples ...
-
bioRxiv - Plant Biology 2022Quote: ... patens cDNA was synthesised using the Tetro cDNA synthesis kit (Bioline) with OligodT primers as per manufacturer’s instructions ...
-
bioRxiv - Genomics 2024Quote: ... cDNA was synthesized using SensiFASTTM cDNA Synthesis Kit (BioLine; BIO-65053) and following all protocol specifications from the vendor ...
-
bioRxiv - Genetics 2023Quote: ... Complementary DNA (cDNA) was synthesized using Tetro cDNA synthesis kit (Bioline). Real-time PCR was done in duplicate with Brilliant II SYBR Green QPCR Master Mix (Agilent Technologies ...
-
bioRxiv - Plant Biology 2023Quote: ... purified and converted to cDNA with sensiFAST cDNA Synthesis Kit (Bioline), using the provided mix of random hexamers and anchored oligo dT primers ...
-
bioRxiv - Cancer Biology 2023Quote: ... cDNA was synthesized using Sensifast cDNA synthesis kit (Bioline, BIO-65054). Quantitative real-time PCR (qPCR ...
-
bioRxiv - Genomics 2024Quote: ... cDNA synthesis was performed using a SensiFAST cDNA synthesis kit (BIOLINE) with equalized amounts of RNA between samples ...
-
bioRxiv - Microbiology 2024Quote: ... and then cDNA was synthesized using SensiFAST cDNA synthesis kit (Bioline) as per the manufacturer’s instructions ...
-
bioRxiv - Immunology 2024Quote: ... cDNA synthesis was performed using the SensiFAST cDNA Synthesis kit (Bioline) and 200 ng of RNA as template ...
-
bioRxiv - Cell Biology 2024Quote: ... cDNA synthesis was performed using a SensiFast cDNA synthesis kit (Bioline). Samples were diluted and mixed with SensiFAST Sybr Lo-Rox master mix before loading as triplicates for qRT-PCR ...
-
bioRxiv - Microbiology 2020Quote: ... 12.5 µL SensiFAST(tm) Probe Hi-ROX Kit master mix (Bioline, Tauton, MA), 1.25 µL each of Cx ...
-
bioRxiv - Cancer Biology 2020Quote: Gene Expression was quantified using the SensiFAST SYBR Hi-Rox Kit (Bioline, 92090) in combination with the StepOnePlus Real-Time PCR System (Thermo Fisher) ...
-
bioRxiv - Microbiology 2023Quote: ... 1.5 µl of sterile water and 7.5 µl SYBR Hi-ROX mix (Bioline). Reaction conditions were as follows ...
-
bioRxiv - Developmental Biology 2024Quote: ... Quantitative RT-PCR reactions were performed with SensiFAST SYBR Hi-ROX kit (Bioline) and gene-specific primers (Supplemental File S2) ...
-
bioRxiv - Molecular Biology 2024Quote: RT-qPCR was performed with the SYBR Hi-ROX SensiMix (Bioline Cat: QT60505) polymerase on a Bio-Rad CFX96 thermocycler ...
-
bioRxiv - Cancer Biology 2024Quote: ... Quantitative gene expression was performed using SensiFAST Probe Hi-ROX kit (Bioline, London) on a QuantStudio 5 (Termo Fischer) ...
-
bioRxiv - Molecular Biology 2021Quote: ... RNA was reverse transcribed to cDNA using SensiFAST cDNA synthesis kit (Bioline). The cDNA was diluted 1:5 with nuclease free water and 5 μL were used per qPCR reaction ...
-
bioRxiv - Developmental Biology 2020Quote: ... cDNA was transcribed using 1µg RNA and sensiFAST cDNA Synthesis Kit (Bioline) following the instructions of the manufacturer.
-
bioRxiv - Biochemistry 2020Quote: ... cDNA synthesis was carried out using SensiFAST cDNA Synthesis Kit from BIOLINE. Quantitation of all gene transcripts was done by qPCR using SYBR Green (Applied Biosystems ...
-
bioRxiv - Cell Biology 2021Quote: ... and cDNA was synthesised with SensiFast cDNA synthesis kit (Bioline, London, UK) according to the manufacturers’ protocols ...
-
bioRxiv - Cancer Biology 2020Quote: ... and 50ng was converted to cDNA using Tetro cDNA synthesis kit (Bioline) with random hexamers ...
-
bioRxiv - Genetics 2022Quote: ... Complementary DNA (cDNA) was synthesised using the Tetro cDNA synthesis kit (Bioline). qRT-PCR of ISGs (Ifit1 and Irf7 ...
-
bioRxiv - Neuroscience 2024Quote: ... and cDNA synthesis was performed using a Tetro cDNA synthesis kit (Bioline) following the manufacturer’s instructions using the GS-1 G-Storm thermocycler (LabTech) ...
-
bioRxiv - Physiology 2024Quote: ... cDNA synthesis was performed using the SensiFAST ™ cDNA Synthesis Kit (Bioline) according to the manufacturer’s instructions ...
-
bioRxiv - Cancer Biology 2024Quote: ... cDNA was synthesized from purified RNA using SensiFAST cDNA Synthesis Kit (Bioline), as per manufacturer’s protocol ...
-
bioRxiv - Microbiology 2021Quote: ... cDNA was synthesized (Bioline) using random hexamers (26) ...
-
bioRxiv - Immunology 2020Quote: ... and cDNA synthesized (Bioline) for subsequent analysis by qPCR.
-
bioRxiv - Plant Biology 2020Quote: ... cDNA library construction was performed using SensiFAST™ cDNA Synthesis Kit (Bioline, Australia).
-
bioRxiv - Genomics 2020Quote: ... RNA was reverse-transcribed into cDNA using the SensiFAST cDNA Synthesis Kit (Bioline). Pluripotency and early differentiation marker as well as selected known imprinted genes expression was determined by qPCR using the Sensifast SYBR No Rox-Kit (Bioline).
-
bioRxiv - Neuroscience 2022Quote: ... cDNA was synthesized with the SensiFAST cDNA Synthesis Kit (Bioline; Cat. No. 65054). Samples were prepared for qPCR in technical triplicates in 5 µL reaction volumes using SensiFAST SYBR Lo-ROX 2X master mix (Bioline ...
-
bioRxiv - Neuroscience 2022Quote: ... after which RNA was converted to cDNA using SensiFASTTM cDNA synthesis kit (Bioline) according to the manufacturer’s instructions ...
-
bioRxiv - Zoology 2020Quote: RNA was reverse transcribed into cDNA using the SensiFAST cDNA Synthesis Kit (BioLine) according to manufacturer’s specifications ...
-
bioRxiv - Microbiology 2021Quote: ... First strand cDNA was synthesised using a Tetro cDNA synthesis kit (Bioline, USA) according to the manufacturer’s protocol ...
-
bioRxiv - Physiology 2021Quote: ... cDNA synthesis was performed using the SensiFAST cDNA Synthesis Kit (Bioline, London, UK). Then ...
-
bioRxiv - Immunology 2020Quote: ... cDNA synthesis was performed using the SensiFast cDNA synthesis kit (Bioline, BIO-65054). SensiFast SYBR No-Rox kit (Bioline ...
-
bioRxiv - Immunology 2020Quote: ... cDNA synthesis was performed with the SensiFast cDNA synthesis kit (Bioline; BIO-65054). SensiFast SYBR No-Rox kit (Bioline ...
-
bioRxiv - Plant Biology 2023Quote: ... cDNA was synthetized from 1μg of RNA using SensiFAST cDNA Synthesis kit (Bioline). RT PCR was carried out in a Rotor-gene Q2 PLEX (QIAGEN) ...
-
bioRxiv - Neuroscience 2023Quote: ... First strand cDNA synthesis was performed using the Tetro cDNA synthesis kit (Bioline). Quantitative PCR (qPCR ...
-
bioRxiv - Cancer Biology 2023Quote: ... cDNA was synthesized by using the SensiFAST cDNA Synthesis kit (Bioline, London, England). Gene expression levels were measured using a MicroAmp Fast Optical 96-well Reaction Plate with Barcode ...
-
bioRxiv - Immunology 2024Quote: ... RNA was used for cDNA synthesis using a SensiFast cDNA synthesis kit (Bioline). qPCR reactions were performed with TaqMan™ Universal Master Mix II (Applied Biosystems™) ...
-
bioRxiv - Cancer Biology 2024Quote: ... cDNA synthesis was performed using the Sensifast cDNA synthesis kit (Bioline, BIO-65053). Gene-specific primers were designed using the Primer-BLAST tool available at the NCBI website (https://www.ncbi.nlm.nih.gov/tools/primer-blast/ ...