Labshake search
Citations for GE Life Sciences :
251 - 300 of 994 citations for Histone H4 mono methyl K16 Rabbit Recombinant mAb since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biophysics 2020Quote: ... equimolar amounts of all histones were dialyzed and the octamer was purified over Superdex 200 (GE healthcare). The DNA and octamer was mixed in a 1:1.1 ratio and purified over a BioRad prep cell after overnight gradient salt dialysis ...
-
bioRxiv - Biochemistry 2021Quote: ... the histone octamer solution was purified via gel filtration (Superdex 200 Increase 10/300 GL; GE Healthcare) that had been pre-equilibrated with Octamer Refolding Buffer ...
-
bioRxiv - Microbiology 2021Quote: ... Recombinant proteins were purified with a HisTrapTM HP (GE Healthcare, Sweden) by an AKTA pure system (GE Healthcare ...
-
bioRxiv - Microbiology 2021Quote: ... The recombinant RBD was captured by Ni-NTA resin (GE Healthcare) and eluted with 500 mM imidazole in HBS buffer ...
-
bioRxiv - Plant Biology 2021Quote: ... The recombinant expressed protein was purified using HisTrap column (GE Healthcare). The His-Sumo tag was digested by ulp1 protease and removed by a second HisTrap column ...
-
bioRxiv - Molecular Biology 2019Quote: ... Recombinant protein was purified using HiTrap DEAEFF (GE Healthcare, Chicago IL), HisTrapHP (Ni-NTA ...
-
bioRxiv - Biochemistry 2020Quote: ... Recombinant proteins in 10 mM acetate buffer (pH 4.5, GE Healthcare) was then injected over the chip surface at a flow rate of 30 μl/min to couple the amino groups of the recombinant proteins to the carboxymethyl dextran matrix ...
-
bioRxiv - Molecular Biology 2021Quote: All recombinant proteins were purified firstly by Ni-NTA (GE healthcare). TOFU-6/PICS-1 was further purified by HiLoad 16/600 Superdex 75 column (GE healthcare ...
-
bioRxiv - Microbiology 2020Quote: ... Recombinant proteins were purified on an AKTA Purifier system (GE Healthcare) using a GSTrap column and elution with 50 mM Tris-HCl ...
-
bioRxiv - Microbiology 2020Quote: ... Recombinant proteins were purified on an AKTA Purifier system (GE Healthcare) using a HiTrap TALON column and eluted with 50 mM sodium phosphate ...
-
Phosphorylation of the Smooth Muscle Master Splicing Regulator RBPMS Regulates its Splicing ActivitybioRxiv - Molecular Biology 2022Quote: ... Recombinant protein was first purified on HisTrap HP column (GE Healthcare) using Buffer A (50mM Tris Base ...
-
bioRxiv - Cell Biology 2022Quote: Recombinant GST-NF2 was bound to a GST resin (GE Healthcare), and MBP-NF2 was bound to an MBP resin (New England Biolabs ...
-
bioRxiv - Cell Biology 2024Quote: ... The recombinant proteins were purified by glutathione Sepharose 4B (GE Healthcare) or Amylose Resin High Flow (New England Biolabs ...
-
bioRxiv - Synthetic Biology 2023Quote: ... recombinant proteins were purified using Ni-Sepharose affinity chromatography (GE Healthcare). Final elution was carried out at 250 mM imidazole ...
-
bioRxiv - Biophysics 2022Quote: ... The different histone chaperone constructs were purified by gravity-flow chromatography using a Ni-NTA resin (GE Healthcare), according to the manufacturer’s instructions ...
-
bioRxiv - Molecular Biology 2023Quote: ... The concentrated histone octamers were further purified on a 120 ml Superdex 200 size exclusion column (GE Healthcare) with SEC buffer (30 mM HEPES-KOH pH 7.5 ...
-
bioRxiv - Immunology 2022Quote: ... mAbs were harvested and purified 7 days after transfection using Protein G Sepharose columns (GE Healthcare). All purified recombinant mAbs were analyzed by SDS-PAGE under reducing conditions using NuPAGE Novex 4-12% Bis-Tris polyacrylamide gels and NuPAGE reducing agent (Life Technologies ...
-
bioRxiv - Bioengineering 2021Quote: ... mAbs were captured from the clarified green juice using MabSelect SuRe Protein A columns (GE Healthcare). Protein A Columns were equilibrated and washed with buffer containing 50 mm Tris ...
-
bioRxiv - Immunology 2020Quote: ... mAbs were purified directly from culture supernatants using HiTrap protein G columns (GE Healthcare Life Sciences) according to the manufacturer’s protocol ...
-
bioRxiv - Immunology 2021Quote: ... mAbs were purified directly from culture supernatants using HiTrap protein G columns (GE Healthcare Life Sciences) according to the manufacturer’s protocol.
-
bioRxiv - Cancer Biology 2023Quote: ... The fluorescently-labeled mAb conjugates were purified via size exclusion chromatography (PD-10 column; GE Healthcare) and concentrated using 50 KDa cutoff amicon filters.
-
bioRxiv - Biochemistry 2020Quote: ... The recombinant expressed protein was purified using a HisTrap column (GE Healthcare). The hexahistidine plus MBP tag was removed by TEV protease digestion followed by a second step HisTrap column (GE Healthcare) ...
-
bioRxiv - Biochemistry 2020Quote: ... The recombinant expressed protein was purified using a HisTrap column (GE Healthcare). The hexahistidine plus yeast sumo tag was removed by ulp1 protease digestion followed by a second step HisTrap column (GE Healthcare) ...
-
bioRxiv - Biochemistry 2019Quote: ... Recombinant G6b-B proteins were immobilized on CM5 sensor chips (GE Healthcare) via an Fc antibody using the Human Antibody Capture Kit (GE Healthcare) ...
-
bioRxiv - Immunology 2019Quote: ... Recombinant antibodies were purified from supernatants using protein-G beads (GE Healthcare).
-
bioRxiv - Microbiology 2020Quote: ... The recombinant proteins were purified on a HisTrap HP column (GE Healthcare), followed by buffer exchange on a HiPrepTM 26/10 desalting column (GE Healthcare) ...
-
bioRxiv - Biochemistry 2021Quote: ... The recombinant protein was then isolated using Ni-NTA resin (GE healthcare) and eluted with a buffer containing 25 mM Tris-HCl ...
-
bioRxiv - Microbiology 2020Quote: ... The supernatant containing recombinant was purified on TALON Superflow resin (GE healthcare) per manufacturer’s instructions ...
-
bioRxiv - Molecular Biology 2021Quote: ... Recombinant proteins were purified on a HiTrap SP HP column (GE Healthcare) and subsequently on a HiTrap Q HP column (GE Healthcare ...
-
bioRxiv - Biochemistry 2023Quote: ... recombinant proteins were first purified using a Ni-NTA column (GE HealthCare) and the His-GST tag was removed by cleavage with 3C-PreScision protease and subsequent incubation with Ni2+ beads to remove the uncleaved protein and the tag from the solution ...
-
bioRxiv - Molecular Biology 2021Quote: ... correctly assembled histone octamers were purified by size exclusion chromatography in refolding buffer on a S200 column (GE Healthcare), using an Akta PURE system (GE Healthcare).
-
bioRxiv - Biochemistry 2022Quote: ... the histones were purified from inclusion bodies under denaturing conditions on a 5 mL HiTrap SP FF (GE Healthcare) cation exchange column on a Next Generation Chromatograph (NGC ...
-
bioRxiv - Biochemistry 2023Quote: Histone proteins were mixed in stoichiometric amounts and eluted through a HiLoad 16/600 Superdex 200pg column (GE Healthcare) to produce H2A-H2B dimers and (H3-H4)2 tetramers separately 40 ...
-
bioRxiv - Cell Biology 2020Quote: ... or anti-CSP repeat antibody – mAB 3D11 (Yoshida et al., 1980) and HRP bound antibodies (GE healthcare, Thermo Fischer Scientific ...
-
bioRxiv - Biochemistry 2022Quote: ... ActRIIB-Fc was isolated using affinity chromatography with Mab Select Sure Protein A (GE healthcare - Waukesha, WI), followed by dialysis into 10mM Tris ...
-
bioRxiv - Biochemistry 2021Quote: ... PKAc was immobilized via standard N-hydroxysuccinimide (NHS) / 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrochloride (EDC) amine coupling on a CM5 (carboxyl methyl dextran) sensor chip (GE Healthcare). Before covalent immobilization of PKAc ...
-
bioRxiv - Molecular Biology 2023Quote: ... The signals of the transferred radioactively labelled methyl groups were detected by autoradiography using a HyperfilmTM high performance autoradiography film (GE Healthcare) at −80LJ°C in the dark ...
-
bioRxiv - Biophysics 2022Quote: ... Histones were extracted from inclusion bodies under denaturing conditions and purified through Q FF and SP FF columns (GE Healthcare). Histone octamers were then refolded by dialysis and purified by gel filtration using a Superdex 200 10/300 GL column.
-
bioRxiv - Biochemistry 2020Quote: ... The octamer of tailless histones was purified by size-exclusion chromatography using a Superdex 200 16/60 column (GE Healthcare), which separated the octamer from aggregate ...
-
bioRxiv - Biochemistry 2022Quote: ... Histones were then further purified by cation exchange on a 5 ml HiTrap SP HP column (GE Healthcare Life Sciences), pre-equilibrated with HGFB150 (full-length histones and tailless H2B) ...
-
A general role of zinc binding domain revealed by structures of σ28-dependent transcribing complexesbioRxiv - Molecular Biology 2020Quote: ... the recombinant protein was purified through 5 mL HisTrap HP column (GE Healthcare), and the eluted protein was further purified through 5 mL HiTrap Heparin HP column (GE Healthcare) ...
-
bioRxiv - Molecular Biology 2020Quote: ... The recombinant proteins were purified through 5 mL HisTrap HP column (GE Healthcare), and the eluted protein was further purified through 5 mL HiTrap Q HP column (GE Healthcare) ...
-
bioRxiv - Microbiology 2021Quote: ... The recombinant proteins were first purified on a HisTrap HP column (GE Healthcare), followed by buffer exchange using HiPrep 26/10 desalting column (GE Healthcare).
-
bioRxiv - Cell Biology 2022Quote: ... The recombinant proteins were purified by Ni+ sepharose 6 fast flow (GE Healthcare), glutathione Sepharose 4B (GE Healthcare ...
-
bioRxiv - Neuroscience 2019Quote: ... Recombinant tau proteins were immobilized on the CM5 sensor chip (Biacore, GE Healthcare) via amine coupling ...
-
bioRxiv - Immunology 2021Quote: ... Recombinant IgG was purified using HiTrap Protein A columns (GE Healthcare Life Sciences). For IgA1 or IgA2 antibodies ...
-
bioRxiv - Pharmacology and Toxicology 2020Quote: ... The recombinant protein was purified through a nickel-nitrilotriacetic acid column (GE Healthcare) and subsequently loaded on a gel filtration column Sephacryl S-200 HR (GE Healthcare ...
-
bioRxiv - Biochemistry 2021Quote: ... Purified recombinant proteins were loaded onto Superdex 75 10/300 column (GE Healthcare) in 150mM NaCl ...
-
bioRxiv - Microbiology 2020Quote: ... The recombinant proteins were purified by Ni2+-IMAC on HisTrap columns (GE Healthcare). Fractions ...
-
bioRxiv - Immunology 2020Quote: ... The recombinant GST fusion proteins were affinity purified on GSH-Sepharose (GE Healthcare) from bacterial cultures incubated with 0.25 mM isopropyl-β-D-thiogalactopyranoside (Sigma-Aldrich ...