Labshake search
Citations for GE Life Sciences :
4301 - 4350 of 4868 citations for Glutathione Colorimetric Detection Kit 200 High Cuvettes since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2021Quote: ... The proteins were further purified according to their size on a HiLoad™ 16/60 Superdex™ 200 prep grade prepacked column (GE Healthcare) using an ÄKTAprime chromatography system at 4°C with a SEC buffer containing 50 mM Tris/HCl ...
-
bioRxiv - Biochemistry 2021Quote: ... AMDHD2 was further purified according to its size on a HiLoad™ 16/60 Superdex™ 200 prep grade prepacked column (GE Healthcare) using an ÄKTAprime chromatography system at 4°C with a SEC buffer containing 50 mM Tris-HCl ...
-
bioRxiv - Biochemistry 2021Quote: ... Selected fractions containing the N protein were concentrated and loaded on two connected Superdex 200 10/300 GL size exclusion columns (GE Healthcare Life Sciences) pre-equilibrated with 20 mM HEPES ...
-
bioRxiv - Biochemistry 2021Quote: ... The self-assembled crude octamers were purified by size-exclusion chromatography on a Superdex-200 10/300 GL column attached to an AKTA FPLC (GE Healthcare, Chicago, IL). Pure fractions were identified by 15% SDS-PAGE after coomassie staining ...
-
bioRxiv - Biochemistry 2020Quote: ... connected to a Shimadzu HPLC unit (Shimadzu Corporation, Kyoto, Japan) with a Superdex 200 Increase 10/300 GL SEC column (GE Healthcare Life Sciences) at constant 10°C temperature and equilibrated with the SEC buffer with and without 2 mM CaCl2 ...
-
bioRxiv - Biophysics 2021Quote: Size Exclusion Chromatography - Multi Angle Light Scattering Experiments were performed with a pre-equilibrated analytical SEC column (Superdex 200 10/300 GL; GE Healthcare Life Sciences) with protein buffer ...
-
bioRxiv - Biophysics 2021Quote: ... Proteins were purified by nickel-affinity chromatography and samples were passed over a HiLoad® 16/600 Superdex® 75 or 200 pg column (GE Healthcare), equilibrated in 20 mM Tris pH 8.0 ...
-
bioRxiv - Cell Biology 2021Quote: ... Peak fractions were pooled and further purified by gel filtration using a Superdex 200 Increase 10/300 GL (GE Healthcare, 28-9909-44) column equilibrated with 20 mM HEPES ...
-
bioRxiv - Biochemistry 2020Quote: ... Full-length GFAT-1 and the isomerase domain were further purified according to their size on a HiLoad™ 16/60 Superdex™ 200 prep grade prepacked column (GE Healthcare) using an ÄKTAprime chromatography system at 4°C with a SEC buffer containing 50 mM Tris/HCl ...
-
bioRxiv - Immunology 2021Quote: ... Eluted particles were concentrated using an Amicon Ultra 15 mL 30K concentrator (MilliporeSigma) and purified by SEC using a HiLoad® 16/600 Superdex® 200 (GE Healthcare) column equilibrated with 25 mM Tris-HCl pH 8.0 ...
-
bioRxiv - Biophysics 2021Quote: ... 1x sodium azide) and injected onto a Superdex-200 increase size-exclusion chromatography column connected to an ÄKTA purifier FPLC apparatus (GE Healthcare Bio-Sciences). Peak fractions were pooled and concentrated to 2 mg/mL of protein before plunge freezing.
-
bioRxiv - Biophysics 2020Quote: ... the Mono Q elutions containing desired proteins were further purified by concentration on Amicon Ultra filters followed by size-exclusion chromatograph using a Superdex 200 10/30 GL column (GE Healthcare Life Sciences) in GF150 buffer (25 mM HEPES pH 7.5 ...
-
bioRxiv - Biophysics 2021Quote: ... Protein fractions were pooled and submitted to size exclusion chromatography (SEC) using a Superdex 200 pg HiLoad 26/600 column (GE Healthcare Life Sciences) equilibrated with 20 mM Tris/HCl ...
-
bioRxiv - Biophysics 2022Quote: ... 50 μl of each sample (at a concentration of 3 mg·ml−1) were loaded onto either a Superdex 75 or 200 HR 10/300 GL columns (GE Healthcare, Madison, WI, USA), equilibrated in 25 mM Hepes (pH 7.8) ...
-
bioRxiv - Molecular Biology 2022Quote: ... Spt6-239-1451 used in chemical crosslinking and mass spectrometry experiments was further purified by size exclusion chromatography (GE Healthcare Sephacryl S-200) and anion exchange chromatography (GE Healthcare HiTrap-Q) ...
-
bioRxiv - Biochemistry 2022Quote: ... the crosslinked-sample was again separated with a flow rate of 0.5 ml/min on a Superdex 200 10/300 GL column (GE Healthcare, Little Chalfont, UK), previously equilibrated with buffer S.
-
bioRxiv - Biochemistry 2022Quote: ... pooled and concentrated to 10 ml and applied to a 320 ml size exclusion column (HiLoad ® 26/600 Superdex ® 200, GE Healthcare). The column was equilibrated with 30 mM PIPES pH 7.4 buffer containing 100 mM NaCl + 1 mM TCEP+ 15 μM PLP and eluted with the same buffer ...
-
bioRxiv - Biochemistry 2022Quote: ... A final size exclusion chromatography step was performed using Superdex 75 HiLoadTM 16/60 SuperdexTM 75pg and HiLoadTM 16/60 SuperdexTM 200 pg columns (GE Healthcare Life Sciences) with buffer containing 25 mM Tris pH 8.0 ...
-
bioRxiv - Microbiology 2020Quote: ... The protein purity and enrichment were confirmed by SDS-PAGE and size exclusion using a HiLoad® 16/600 Superdex® 200 pg column using an ÄKTA pure (GE healthcare). However ...
-
bioRxiv - Microbiology 2020Quote: ... The mixtures were incubated at 4°C for 1 h prior to purification on a Superdex 200 Increase SEC column (GE Healthcare Life Sciences) in buffer containing 150mM NaCl ...
-
bioRxiv - Biochemistry 2020Quote: ... These affinity-purified protein concentrates were then applied to a previously equilibrated HiLoad 16/600 Superdex 200 pg column (GE Healthcare Life Sciences) packed with dextran covalently bound to highly cross-linked agarose ...
-
bioRxiv - Biophysics 2021Quote: ... The aggregates and liposomes were removed from the mixture by size-exclusion chromatography using a Superdex 200 Increase column (GE Healthcare Life Sciences) and the peak fractions containing nanodiscs of around 11 nm in diameter were collected.
-
bioRxiv - Microbiology 2019Quote: ... and then further purified by FPLC size exclusion chromatography using a HiLoad 16/60 Superdex 200 prep grade column (GE Healthcare Life Sciences). Pure 6xHis+t-ShyA fractions were collected and concentrated up to 11.4 mg/ml ...
-
bioRxiv - Molecular Biology 2019Quote: ... characterization of an N-terminal Aβ peptide DAE-EG (DAEFRHDSGYSGKQKSRNEGKGGC) binding to anti-mouse captured antibodies from hybridoma supernatants was performed using a BIAcore T-200 instrument (GE Healthcare, Marlborough, MA) [36] ...
-
bioRxiv - Biochemistry 2020Quote: Proteins were expressed and purified as described and then passed over an AKTA pure with an inline Superdex 200 Increase 10/300 GL column (GE Healthcare Life Sciences), miniDAWN TREOS ...
-
bioRxiv - Microbiology 2020Quote: ... The Vip3Aa200-end proteins were further purified by HiTrap Q HP ion-exchange chromatography and Superdex 200 gel filtration chromatography (GE Healthcare Life Sciences). Fractions containing the Vip3Aa200-end protein were concentrated to ∼ 7 mg/ml for crystallization ...
-
bioRxiv - Microbiology 2021Quote: ... The entire ectodomain of IFX was used as the analyte which was first purified and resolved by size exclusion chromatography on a Superdex 200 Increase 10/300 column (GE Healthcare, Chicago, IL) in HBS-EP (10 mM HEPES ...
-
bioRxiv - Biochemistry 2021Quote: ... The elution was concentrated and further purified by size exclusion chromatography using a HiLoad® 26/600 Superdex® 200 PG (GE Healthcare) column equilibrated with SEC-buffer (200 mM NaCl ...
-
bioRxiv - Biochemistry 2020Quote: ... and the CBP eluates were further purified by gel-filtration chromatography using a Superdex 200 Increase 10/300 GL column on an ÄKTA Pure purification system (Cytiva, formerly GE Healthcare Life Sciences). The proteins in the peak fractions were collected and concentrated to 1-3 mg/mL for storage at −75°C ...
-
bioRxiv - Immunology 2020Quote: ... Eluted VLPs were concentrated using an Amicon Ultra 15 mL 30K concentrator (MilliporeSigma) and further purified by SEC using a HiLoad® 16/600 Superdex® 200 (GE Healthcare) column equilibrated with 500 mM glycine pH 8.0 ...
-
bioRxiv - Immunology 2020Quote: ... Eluted NPs were concentrated using an Amicon Ultra 15 mL 30K concentrator (MilliporeSigma) and further purified by SEC using a HiLoad® 16/600 Superdex® 200 (GE Healthcare) column equilibrated with 25 mM Tris-HCl pH 8.0 ...
-
bioRxiv - Biochemistry 2020Quote: ... The elution was concentrated and loaded onto a Superdex 200 Increase 10/300 GL size exclusion column (GE Healthcare Life Sciences, Pittsburgh, PA) equilibrated with minimal buffer (25 mM HEPES-NaOH (pH 7.5) ...
-
bioRxiv - Microbiology 2022Quote: ... and further purified by affinity chromatography using resin attached with streptavidin or Ni-NTA and size-exclusion chromatography (SEC) using a Superdex 200 column (GE Healthcare Life Sciences) with the buffer containing 20 mM Tris pH 8.0 and 200 mM NaCl.
-
bioRxiv - Biophysics 2021Quote: ... was achieved through incubation at RT for 1 h and subsequent size-exclusion chromatography on a 16/600 Superdex 200 pg column (GE Healthcare, Pittsburgh, USA), equilibrated in storage buffer (50 mM HEPES pH 7.25 ...
-
bioRxiv - Biochemistry 2020Quote: ... The protein was further purified by size exclusion chromatography (SEC) using a HiPrep™ 26/60 Sephacryl™ S-200 HR (GE healthcare) column previously equilibrated in 20 mM HEPES pH 8.0 ...
-
bioRxiv - Immunology 2020Quote: ... Fractions that yielded proliferation of TN T cells were pooled and subjected to cation exchange chromatography on a Mono S 5/200 GL column (GE Healthcare, Piscataway NJ). The active fractions were again pooled and subjected to buffer exchange (Amicon ultra 3k cutoff ...
-
bioRxiv - Microbiology 2019Quote: ... Eluted proteins were further purified via size exclusion chromatography using a HiLoad 16/60 Superdex 200 gel filtration column (GE Healthcare, Chicago, IL) using an AKTAExplorer 100 FPLC (GE Healthcare) ...
-
bioRxiv - Immunology 2020Quote: ... affinity-purified proteins were further purified by size-exclusion chromatography (SEC) using a HiLoad 16/600 Superdex 200 pg column (GE Healthcare Life Sciences) in 1x TBS (20 mM Tris-HCl pH 8.0 ...
-
bioRxiv - Immunology 2020Quote: ... Large-scale capability demonstration RNA production was performed using a 200 mg scaled-up process and purified via column on a Capto Core 700 instrument (GE Healthcare Life Sciences) and tangential flow filtration.
-
bioRxiv - Biochemistry 2022Quote: ... were subjected to size-exclusion chromatography using a Superdex 200 Increase 10/300 GL column connected to an AKTA PURE 25 FPLC system (GE Healthcare Life Sciences) maintained at 6° C ...
-
bioRxiv - Biochemistry 2022Quote: ... The treated sample was further purified by IMAC and was subjected to size-exclusion chromatography (SEC) using HiLoad Superdex 200 pg (GE Healthcare Life Sciences) in 10 mM HEPES ...
-
bioRxiv - Immunology 2022Quote: ... mFcRn) were purified using a HisTrap Ni NTA column followed by size exclusion chromatography (Superdex 200 Increase column; both GE Healthcare, Chicago, IL) using 20 mM phosphate pH 8.0 ...
-
bioRxiv - Microbiology 2022Quote: ... Eluted particles were concentrated using an Amicon Ultra 15 mL 30K concentrator (MilliporeSigma) and SEC purified using a HiLoad® 16/600 Superdex® 200 (GE Healthcare) column equilibrated with 25 mM Tris-HCl pH 8.0 ...
-
bioRxiv - Microbiology 2022Quote: ... Samples then underwent size exclusion chromatography in an ÄKTA Pure fast protein liquid chromatography (FPLC) using HiLoad 16/600 Superdex 200 or Superdex 75 column (GE Healthcare Life Sciences) in GF-300 buffer (25 mM HEPES buffer at pH 7.5 ...
-
bioRxiv - Biochemistry 2022Quote: ... The treated sample was further purified by IMAC and was subjected to size-exclusion chromatography (SEC) using HiLoad Superdex 200 pg (GE Healthcare Life Sciences) in 10 mM HEPES ...
-
bioRxiv - Microbiology 2022Quote: ... The proteins were further purified by HiTrap Q HP ion-exchange chromatography and Superdex 200 Increase 10/300 GL gel filtration chromatography using an ÄKTApure chromatography system (GE Healthcare Life Sciences). Proteins corresponding to the molecular weight of the tetramerized Vip3Aa were used for subsequent biochemical and bioassay analyses ...
-
bioRxiv - Cell Biology 2022Quote: ... The eluted protein from this affinity step was concentrated and further purified by gel filtration on a HiLoad® 16/600 Superdex® 200 pg column (GE Healthcare) equilibrated in 20 mM TrisHCl ...
-
bioRxiv - Biophysics 2024Quote: All size exclusion chromatography was carried out using HMK buffer with 5 mM DTT added unless stated otherwise using a Superdex 200 10/300 column (GE healthcare Life Sciences). For each experiment ...
-
bioRxiv - Immunology 2023Quote: ... and subjected to size-exclusion chromatography (Superdex 200 increase 10/300 gl and Superdex 75 Increase 10/300 GL, GE Healthcare Life Sciences) and anion-exchange chromatography (Mono Q 5/50 GL ...
-
bioRxiv - Biochemistry 2023Quote: Analytical size exclusion HPLC of purified complexes of Af1:7B8 and Af2:7B8 were carried out using a Superdex 200 5/150 GL column (GE Healthcare, Freiburg, Germany) equilibrated in PBS ...