Labshake search
Citations for GE Life Sciences :
4251 - 4300 of 4868 citations for Glutathione Colorimetric Detection Kit 200 High Cuvettes since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Immunology 2024Quote: ... was incubated at room temperature for 20 minutes with a 1.2-fold molar excess of ADI-46143 Fab and the complex was purified by SEC on a Superdex 200 Increase 10/300 GL (GE Healthcare Biosciences) in 2 mM Tris pH 8.0 ...
-
bioRxiv - Immunology 2024Quote: ... Complexes were incubated for 20 minutes at 23 ℃ before further purification via SEC on a Superdex 200 Increase 10/300 GL (GE Healthcare Biosciences) in 2 mM Tris pH 8.0 ...
-
bioRxiv - Molecular Biology 2024Quote: ... The protein fraction obtained was further subjected to Hi-Load Superdex 200 pg 16/600 size-exclusion chromatography column (GE Healthcare/Cytiva) equilibrated with buffer B (20 mM Tris pH 7.5 ...
-
bioRxiv - Molecular Biology 2024Quote: ... The protein eluate was buffer exchanged into 1X PBS and then purified by size exclusion chromatography using a Superdex 200 Increase 10/300 GL Sizing column on the AKTA FPLC system (GE Life Sciences). The fractions of purified protein were analyzed by SDS-PAGE and binding was confirmed using ELISA with known antibodies.
-
bioRxiv - Biochemistry 2024Quote: ... was performed on the double affinity (Ni-+Co-affinity) purified Mtb EfpA using a Superdex™ 200 increase 10/300 GL size-exclusion column (GE Healthcare) plugged into an AKTÄ explorer 100 (Amersham Biosciences ...
-
bioRxiv - Biochemistry 2024Quote: ... TBC-DEG-αβ-tubulin assemblies were purified by size exclusion chromatography (SEC) using a Superdex 200 10/300 column (GE Healthcare, USA) in binding buffer (50 mM HEPES ...
-
bioRxiv - Cell Biology 2023Quote: ... protein solutions were further concentrated to ∼ 100 µM and purified by size exclusion with a Superdex 200 column (SD200 16/60) on an AEKTA purifier (GE Life Sciences) in the final storage buffer (200 mM NaCl ...
-
bioRxiv - Biophysics 2023Quote: ... The amine modified dT nucleotides were labeled with Cy5 in a 20 µL reaction containing 10 mM (200 nmol) NHS-Cy5 (GE Healthcare, PA15100), 0.1 mM (2 nmol ...
-
bioRxiv - Biochemistry 2023Quote: The changes in the oligomeric state of PrASNase were studied using the gel filtration column Superdex-200 (10/300 GL Increase, GE Healthcare, USA). The PrASNase was freshly purified and distributed equally in two different vials ...
-
bioRxiv - Biophysics 2023Quote: ... then concentrated in a 10 kDa NMWL centrifugal filters (Amicon #UFC9003) to ∼500 μL and injected on a Superdex 200 10/30 GL size exclusion column (GE Healthcare #28990944) equilibrated in size exclusion buffer (SEB ...
-
bioRxiv - Biochemistry 2023Quote: ... NCPs were concentred through a 100 kDa spin concentrator column (Amicon® Devices) and loaded on an HiLoad 16/600 Superdex 200 size exclusion column (GE Healthcare) in 20mM HEPEs pH 7.5 ...
-
bioRxiv - Biochemistry 2023Quote: ... 100 µL of purified proteins at 5 mg/mL were injected onto a Superdex 200 Increase 10/300 GL column (GE Life Sciences) in buffer GF ...
-
bioRxiv - Molecular Biology 2023Quote: ... the NbaAgo samples (3 mg/ml in 33 μl) were loaded onto a Superdex 200 Increase 10/300 column (GE Healthcare, USA) operated on a ProStar335 system and connected to a tandem of Prostar 335 detector (Varian ...
-
bioRxiv - Biochemistry 2023Quote: ... Protein samples at 12-25 mg/ml were prepared as described above for SEC-MALS and were loaded onto a Superdex™ 200 Increase 10/300 GL size exclusion chromatography column (GE Healthcare) in 20 mM Hepes pH 7.5 ...
-
bioRxiv - Biochemistry 2023Quote: ... Protein samples at 8-13 mg/ml were loaded onto a Superdex™ 200 Increase 10/300 GL size exclusion chromatography column (GE Healthcare) in 20 mM Hepes pH 7.5 ...
-
bioRxiv - Physiology 2023Quote: Plasma samples (200 μL) were loaded onto AKTA pure FPLC column [Superose™ 6 Increase 10/300 GL FPLC column (GE Healthcare). Lipoproteins were eluted with PBS and 0.25 mL fractions were collected at a flow rate of 0.4 mL/min.
-
bioRxiv - Biochemistry 2023Quote: ... Protein samples at concentrations >8 mg/ml were loaded onto a Superdex™ 200 Increase 10/300 GL size exclusion chromatography column (GE Healthcare) in 20 mM HEPES pH 7.5 ...
-
bioRxiv - Biophysics 2023Quote: ... and gel filtration chromatography on a HiLoad 16/60 Superdex 200 column controlled by an AKTA pure FPLC system (GE Life Sciences). The protein was concentrated to ∼3 mg/ml in buffer containing 150 mM NaCl ...
-
bioRxiv - Molecular Biology 2023Quote: ... 6xHis-3xFLAG-V1H(1-351) was further purified by gel filtration on a Superdex 200 10/300 GL column (GE Life Sciences) into the appropriate buffer for the subsequent application ...
-
bioRxiv - Cell Biology 2023Quote: ... Concentrated protein was further purified by size exclusion chromatography on a Superdex 200 Increase 10/300 GL (GE healthcare, GE28-9909-44) in SEC buffer ...
-
bioRxiv - Biochemistry 2023Quote: ... L proteins then used for single-particle cryo-EM were further purified by size-exclusion chromatography using a Superdex 200 column (Cytiva, formerly GE Life Sciences) in buffer B ...
-
bioRxiv - Biochemistry 2023Quote: ... The purified protein was concentrated and subjected to gel-filtration chromatography using a Superdex 200 increase 10/300 column (GE Healthcare, USA), pre-equilibrated with gel-filtration buffer containing 25 mM HEPES pH 7.5 ...
-
bioRxiv - Cell Biology 2023Quote: ... Protein samples at concentrations >5 mg/ml were loaded onto a Superdex™ 200 Increase 10/300 GL size exclusion chromatography column (GE Healthcare) in 20 mM Tris pH 8.0 ...
-
bioRxiv - Biophysics 2023Quote: ... The processed proteins were purified by size-exclusion chromatography on a Superdex 200 Increase 10/300 GL column (GE Healthcare, Chicago, IL). Purified ...
-
bioRxiv - Molecular Biology 2024Quote: ... ALBA1 was further purified on a HiLoad Superdex™ 200 10/300 GL prep grade column (GE Healtcare) connected to an HPLC ÄKTA Purifier system (GE Healthcare). Eluates were monitored at A280 ...
-
bioRxiv - Plant Biology 2024Quote: ... Enrichment of N-terminal labeled peptides was carried out using 200 µL NHS-Sepharose slurry (17-0906-01, GE Healthcare, Solingen, Germany) per 100 µg protein ...
-
bioRxiv - Cell Biology 2020Quote: ... GST kit (GE Healthcare, Chicago, IL) was used for purifying GST-Rheb following manufactures instructions and eluted with reduced glutathione ...
-
bioRxiv - Cell Biology 2019Quote: ... ECL chemiluminescent kit (RPN2132, GE Healthcare) was used for detection according to manufacturer’s instructions.
-
bioRxiv - Neuroscience 2020Quote: ... A His-capture kit (GE Healthcare) was used to immobilize anti-His antibodies on CM5 chips (as recommended by the manufacturer) ...
-
bioRxiv - Cancer Biology 2019Quote: ... The His SpinTrap Kit (GE Healthcare) was used according to manufacturer’s recommendations to purify the recombinant CELF1 proteins ...
-
bioRxiv - Cell Biology 2019Quote: ... The ECL Prime Kit (GE Healthcare) was used for HRP detection.
-
bioRxiv - Cell Biology 2020Quote: ... 0.5 mM TCEP) using an AKTA pure chromatography system with a Superdex 200 10/300 GL column attached (GE Healthcare, GE17-5175-01). The in vitro interaction experiments using recombinant Ana1 fragments and commercial GST-PBD (Sigma ...
-
bioRxiv - Microbiology 2021Quote: ... The MxiN and Spa33 were combined with an excess of MxiN and the mixture was concentrated to a final volume of 2 mL for injection onto a Hi Load 26/600 Superdex 200 pg column (GE Healthcare Life Sciences). The protein absorbance at 280 nm was monitored to detect protein elution on an AKTA system (GE Healthcare Life Sciences) ...
-
bioRxiv - Neuroscience 2021Quote: ... The affinity tag for Munc18 was cleaved by 2 mg of TEV in PBS with 400 mM imidazole overnight at 4℃ and additional purification was performed using superdex 200 10/300 GL (GE Healthcare, Piscataway, NJ) gel filtration column in TBS buffer (20 mM Tris pH 7.5 ...
-
bioRxiv - Biophysics 2022Quote: ... The eluate was concentrated and then applied to an initial size-exclusion chromatography (SEC) step using HiLoad 16/60 Superdex 200 (GE Healthcare, Chicago IL) in SEC200 buffer (50 mM Tris-HCl ...
-
bioRxiv - Immunology 2020Quote: ... Resulting neoglycoconjugates were separated by size-exclusion chromatography on a HiPrep 26/100 Sephacryl® S-200 HR column (GE Healthcare Life Sciences), and fractions were analyzed by 10% SDS-PAGE ...
-
bioRxiv - Biophysics 2019Quote: ... was used to remove the residual impurities by passing through a Superdex 200 10/300 GL gel filtration column (GE Healthcare Life Sciences). The peak fractions were collected and concentrated to 10-12 mg/ml ...
-
bioRxiv - Biochemistry 2019Quote: ... The RNA was then separated from the plasmid and remaining NTPs by FPLC purification using a Superdex 200 filtration column (GE Healthcare Life Sciences) using TEK or TELi buffer ...
-
bioRxiv - Pharmacology and Toxicology 2019Quote: Purified proteins were analyzed by size-exclusion chromatography on a Superdex 200 increase 10/300 GL column on an ÄKTA FPLC (GE Healthcare, Amersham Biosciences). SDS-PAGE was performed with 10% gels (Invitrogen ...
-
bioRxiv - Molecular Biology 2020Quote: ... Fractions showing more than 95% purity were pooled and dialyzed in buffer A containing 200 mM NaCl and further purified from HiTrap Heparin HP affinity columns (GE Healthcare Life sciences) using a linear gradient of NaCl ...
-
bioRxiv - Biophysics 2019Quote: ... The mAb TS2/4-biotin was purified from an excess of NHS-LC-LC-Biotin via gel filtration (Superdex-200 10/300; GE Healthcare Life Sciences), concentrated using Amicon Ultra-4 centrifugal filters (10 kDa cut-off ...
-
bioRxiv - Bioengineering 2019Quote: Purified proteins were analyzed by size-exclusion chromatography on a Superdex 200 increase 10/300 GL column on an ÄKTA FPLC (GE Healthcare, Amersham Biosciences). SDS-PAGE was performed with 10% gels (Invitrogen ...
-
bioRxiv - Biophysics 2020Quote: ... concentrated again (10kDa Amicon®Ultra-4 centrifugal filters) and further purified via gel filtration (Superdex-200 10/300, GE Healthcare Life Sciences). After removal of the poly-E tag with the 3C protease (MERCK) ...
-
bioRxiv - Biophysics 2020Quote: ... AF555-conjugated I-Ek/MCC complexes (either C-terminally extended with 2xHis6 or biotin) were subjected to gel filtration (Superdex-200 10/300 GE Healthcare Life Sciences) to remove an excess of unreacted MCC-AF555 ...
-
bioRxiv - Biophysics 2020Quote: ... the H57-scFV was concentrated with a stirred 10 kDa ultrafiltration cell (PBGC04310, MERCK and purified by means of gel filtration (Superdex-200 10/300 GE Healthcare Life Sciences) using an ÄKTA pure chromatography system (GE Healthcare Life Sciences) ...
-
bioRxiv - Biophysics 2020Quote: ... concentrated again (10kDa Amicon®Ultra-4 centrifugal filters) and further purified via gel filtration (Superdex-200 10/300, GE Healthcare Life Sciences). After removal of the poly-E tag located on the “alive” subunit with 3C protease (MERCK ...
-
bioRxiv - Biochemistry 2021Quote: ... The protein was concentrated to 2 mL in a 30 kDa MWCO spin concentrator and applied onto a HiLoad 16/600 Superdex 200 pg size exclusion chromatography (SEC) column (GE healthcare, IL, USA) equilibrated in 20 mM Tris-HCl pH 7.4 ...
-
bioRxiv - Biochemistry 2021Quote: ... Mint3NT was purified using SEC with a HiLoad 26/60 Superdex® 200 pg or 75 pg column (GE Healthcare, Illinois, United States) at 4°C ...
-
bioRxiv - Biochemistry 2020Quote: ... the reaction mixture was applied to a Superdex 200 Increase 10/300 GL gel filtration column (GE Healthcare Life Sciences #28-9909-44) to remove excess glutaryl-CoA/succinyl-CoA ...
-
bioRxiv - Microbiology 2021Quote: Analytic SEC was adopted to investigate the oligomeric state of AmnC and its variants using a Superdex 200 10/300 GL column (GE Healthcare, United States). The column was pre-equilibrated with analysis buffer (50 mM Tris-Cl ...