Labshake search
Citations for GE Life Sciences :
2401 - 2450 of 4130 citations for Monocyclohexyl Phthalate 100 Ug Ml In Mtbe Ring 1 2 13C2 Dicarboxyl 13C2 99% since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2020Quote: ... The supernatant was then applied onto a Hi Trap affinity (5 ml) (Ni2+) column (GE Healthcare Life Sciences) The column was washed with 10 column volumes of buffer A ...
-
bioRxiv - Biochemistry 2021Quote: ... The supernatant was filtered and loaded onto a 5 mL HisTrap HP column (GE Life Sciences, now Cytiva), followed by washing [0.05 M Tris pH 7.5 ...
-
bioRxiv - Biochemistry 2021Quote: ... Cleaved DEPTOR protein was then collected and applied to a 5 mL HiTrap Heparin HP column (GE Healthcare) equilibrated with HEP-A buffer (50 mM HEPES pH 8 ...
-
bioRxiv - Biochemistry 2021Quote: ... 4 °C) and the supernatant applied to a GSTrap 5 ml FF column affinity purification column (GE Healthcare) at 4 °C equilibrated with Tris-Cas-A buffer ...
-
bioRxiv - Immunology 2021Quote: ... at a flow rate of 0.7 ml/min in the ÄKTA prime-plus liquid chromatography system (GE Healthcare). Non-specifically bound proteins were washed off by passing at least 20 column volumes of wash buffer (50 mM Tris-HCl ...
-
bioRxiv - Biochemistry 2019Quote: ... His6–Ub-tagged SbtB7001 was purified from cell lysate using a 5 ml HisTrap FF column (GE Healthcare): the pre-equilibrated and lysate-loaded column was washed with binding buffer (20 mM NaH2PO4 ...
-
bioRxiv - Biochemistry 2019Quote: ... Lysate was clarified by centrifugation and loaded onto a HisTrap™ High-Performance 5 mL columns (GE Healthcare) using a peristaltic pump ...
-
bioRxiv - Plant Biology 2019Quote: ... fitted with a Superose 6 Increase 10/300 GL geometric column of 24 ml bed volume (GE Healthcare) was coupled to multi angle light-scattering (MALS ...
-
bioRxiv - Molecular Biology 2019Quote: ... The proteins from the cleared cell lysate were captured in a HisTrap HP 5 ml column (GE Healthcare) in His buffers (20 mM MOPS ...
-
bioRxiv - Biochemistry 2020Quote: ... and the crude lysates were applied to 5 ml HiTrap Capto Q column (GE Healthcare Life Sciences, USA) equilibrated with 5 volumes of buffer A (20 mM Tris (pH 8.0) ...
-
bioRxiv - Molecular Biology 2021Quote: ... the supernatant containing complexes of Panx and LC8 was loaded onto 5 ml HisTrap Fastflow column (GE Healthcare). After extensive washing with Binding buffer ...
-
bioRxiv - Pathology 2021Quote: ... diluted five-fold with extraction buffer and applied to a 5 ml HisTrap column (GE Healthcare, Chicago, IL) equilibrated with extraction buffer ...
-
bioRxiv - Biophysics 2020Quote: ... The EcA2 used for these experiments were previously desalted in a 5-mL HiTrap Desalting (GE Healthcare, USA) and eluted in 10 mM sodium phosphate at pH 7.0 ...
-
bioRxiv - Evolutionary Biology 2020Quote: ... The lysate obtained was loaded onto the pre-equilibrated nickel affinity column (HisTrap FF, 5 mL, GE Healthcare) with loading buffer (50 mM KPi ...
-
bioRxiv - Cancer Biology 2019Quote: ... concentrated and then buffer exchanged by size exclusion chromatography (SEC) using a Superdex75 24 ml column (GE healthcare) equilibrated in 50 mM HEPES pH 7.5 ...
-
bioRxiv - Molecular Biology 2019Quote: ... The cleared lysate was filtered (0.8 µM) and applied to 5 or 10 ml HisTrap FF (GE Healthcare) equilibrated in washing buffer (20 mM Tris-HCl ...
-
bioRxiv - Genetics 2019Quote: The clarified lysate containing mZCWPW1 was then loaded onto a 5 mL His-Trap HP column (GE Healthcare) using NGCTM chromatography system (BioRad) ...
-
bioRxiv - Microbiology 2020Quote: ... The eluate was concentrated to 1.0 ml and loaded onto a Superdex 200 size-exclusion column (GE healthcare) in running buffer containing 10 mM Tris pH 7.4 ...
-
bioRxiv - Biochemistry 2021Quote: ... Full PRC2 complex was separated by size-exclusion chromatography on a 24 mL Superose 6 column (GE Healthcare) in 10 mM Tris-HCl pH 7.5 ...
-
bioRxiv - Microbiology 2022Quote: ... Strep-tagged proteins were affinity-purified on an ÄKTA Purifier using 5 ml StrepTrap HP columns (GE Healthcare) according to manufacturer’s instructions ...
-
bioRxiv - Biochemistry 2022Quote: ... Salt concentration is adjusted and protein is loaded on a 10 ml HiTrap Heparin HP column (GE Healthcare) equilibrated in 20 mM HEPES- KOH pH 7.5 ...
-
bioRxiv - Biochemistry 2022Quote: ... Recombinant Sau-MenD was purified at room temperature by IMAC with 5 mL HisTrap HP columns (GE Healthcare) and an imidazole gradient of 20–500 mM over 50 mL ...
-
bioRxiv - Biochemistry 2022Quote: ... The soluble fraction was added to a 5 mL Ni-Sepharose fast-flow resin (GE Healthcare Life Sciences) pre-equilibrated with buffer A at room temperature ...
-
bioRxiv - Biophysics 2022Quote: ... and 0.03% DDM (TE buffer) before anion exchange chromatography using a 6 mL Resource Q column (GE Healthcare). Nucleotide-free Tth V/A-ATPase (Vnucfree ...
-
bioRxiv - Cell Biology 2022Quote: ... Clear lysate was incubated with 0.5 ml packed beads IgG Sepharose 6 Fast-Flow (GE Healthcare, Chicago, IL) for 2-3 hours at 4°C on a tube roller ...
-
bioRxiv - Cell Biology 2024Quote: ... We then applied the supernatant onto two tandem 5 mL HiTrap Q HP anion exchange columns (GE Healthcare) pre-equilibrated with 20 mM Tris pH 8.0 ...
-
bioRxiv - Biophysics 2024Quote: The PCR product was purified via ion exchange chromatography using a 5 ml HiTrap Q column (GE Healthcare). The column was equilibrated in Buffer A (25 mM HEPES 7.5 ...
-
bioRxiv - Biochemistry 2023Quote: ... Then the solution was injected onto a prewashed SP Sepharose HiTrap column (5 ml, GE Healthcare, Chicago, IL). The column was washed with 20 CV of Buffer D (20 mM HEPES-KOH pH 7.5 ...
-
bioRxiv - Genetics 2023Quote: ... for 45 min and soluble extract was applied to a 5 ml HisTrap FF column (GE healthcare Inc.) using a GE AKTA Avant 25 FPLC system ...
-
bioRxiv - Microbiology 2023Quote: ... proteins were separated by immobilized-metal affinity chromatography (IMAC) on a 5 mL HisTrap HP column (GE Healthcare), previously washed with ddH2O and equilibrated with buffer B (25 mM HEPES/NaOH pH 7.5 ...
-
bioRxiv - Immunology 2022Quote: ... The pellet was resuspended in a 15mL tube in 12 mL of Percoll (GE Healthcare, 17-0891-01). The sample was then centrifuged at 650g for 25 min without brake ...
-
bioRxiv - Biophysics 2023Quote: ... Protein was purified using a 20 mL NiNTA column (Cytiva) attached to an Akta M FPLC (GE Healthcare) and with a 300 mM imidazole elution buffer ...
-
bioRxiv - Microbiology 2023Quote: ... The cell-free lysate was applied to a 5 ml His Trap™ HP column (GE Healthcare, USA) equilibrated in the same buffer ...
-
bioRxiv - Biochemistry 2023Quote: ... and then loaded onto a 24 mL Superdex 200 10/300 GL (GE Healthcare, Cat# 17-5174-01) size exclusion column equilibrated in 20 mM Tris pH [8] (20mM HEPES pH [7.5] for FL SHIP1) ...
-
bioRxiv - Biochemistry 2023Quote: ... and then loaded onto a 24 mL Superdex 200 10/300 GL (GE Healthcare, Cat# 17-5174-01) size exclusion column equilibrated in 20 mM Tris pH [8] ...
-
bioRxiv - Biochemistry 2023Quote: ... The sample was then transferred to a 5 mL tube containing 300 μL CaM-Sepharose resin (GE Healthcare) equilibrated in 50 mM HEPES (pH 7.2 ...
-
bioRxiv - Biochemistry 2023Quote: ... The sample was then applied onto a 120 mL HiLoad 16/600 Superdex 200 column (GE Healthcare, Inc.) equilibrated in buffer B ...
-
bioRxiv - Molecular Biology 2023Quote: ... The concentrated histone octamers were further purified on a 120 ml Superdex 200 size exclusion column (GE Healthcare) with SEC buffer (30 mM HEPES-KOH pH 7.5 ...
-
bioRxiv - Biochemistry 2023Quote: The ammonium sulfate treated hMDH preps were loaded onto a 5 mL HiTrap Butyl HP column (GE Healthcare). An inverse linear gradient of ammonium sulfate from 1.5 M to 0 M was used to purify hMDH where it eluted at a conductivity of 135 mS/cm ...
-
bioRxiv - Biophysics 2023Quote: ... centrifuged and applied to a cation exchange chromatography column (5 mL HiTrap SP HP, GE Healthcare Life Science) equilibrated with 25 mM sodium phosphate ...
-
bioRxiv - Biochemistry 2023Quote: ... a second nickel-affinity chromatography was performed (His Trap, 5 mL, GE Healthcare; equilibrated in 10% HisB buffer). Sample was loaded and unbound protein further washed out with 10% HisB ...
-
bioRxiv - Microbiology 2024Quote: ... at a flow rate of 0.7 ml/min in the ÄKTA prime-plus liquid chromatography system (GE Healthcare). Non-specifically bound proteins were washed off by passing at least 20 column volumes of the wash buffer (300 mM NaCl ...
-
bioRxiv - Molecular Biology 2024Quote: Clarified lysate was added to 2.3 mL of a 50% IgG Sepharose 6 Fast Flow resin (GE Healthcare) slurry and incubated on a roller for 1 hour ...
-
bioRxiv - Biochemistry 2024Quote: ... TEV protease and non-cleaved protein was removed by IMAC (HisTrap FF Crude column, 5 ml, GE Healthcare) with a linear gradient of imidazole (0-500 mM) ...
-
bioRxiv - Biochemistry 2024Quote: ... The eluents were pooled and directly loaded onto HiTrap Q HP 5 mL anion exchange column (GE Healthcare) pre-equilibrated with buffer D [50 mM Tris-HCl (pH 7.5) ...
-
bioRxiv - Biochemistry 2024Quote: ... The dialyzed solution was then loaded on a 5 ml HiTrap SP FF column (GE Healthcare, Pittsburgh, PA) and eluted using a linear gradient of NaCl (20-500 mM) ...
-
bioRxiv - Microbiology 2024Quote: ... The sample was then applied onto a 120- mL HiLoad 16/600 Superdex 200 column (GE Healthcare, Inc.) and eluted with buffer C (20 mM Tris–HCl ...
-
bioRxiv - Neuroscience 2020Quote: ... Blots were incubated with HRP-conjugated secondary anitbodies at 1:3,000 for 1 h at room temperature and bands developed using ECL Prime Western Blotting Detection Reagent (GE Healthcare). Blots were subsequently incubated with 1:20,000 HRP-conjugated β-actin (Abcam ...
-
bioRxiv - Biochemistry 2019Quote: ... For further purification the protein was diluted 1:1 with 20 mM HEPES KOH (pH 7.5) and loaded on a HiTrap Heparin HP (GE Healthcare) column ...
-
bioRxiv - Bioengineering 2020Quote: ... for HRP-conjugated antibodies: donkey monoclonal anti-mouse (1:10000) and donkey monoclonal anti-rabbit antibody (1:10000, GE Healthcare) diluted in 2% BSA-TBST ...