Labshake search
Citations for GE Life Sciences :
2251 - 2300 of 2500 citations for 5 Bromo 2 Tert Butyldimethylsilyl 4 Methylthiazole since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
Improved Activity and Kinetics of Endoglucanase Biofuel Enzyme with Addition of an AzoTAB SurfactantbioRxiv - Bioengineering 2023Quote: ... The protein solution was filtered and applied to a 5 mL HiTrap Q HP anion exchange column (GE Healthcare, Cat. no. 17115301) and later washed with 30× column volume with the protein buffer ...
-
bioRxiv - Biochemistry 2023Quote: The supernatant containing the target protein was then loaded on a 5 mL Ni-NTA column followed by a size exclusion column (Superdex 75, GE Healthcare, USA). YsiA is then eluted stepwise with 30 mM ...
-
bioRxiv - Microbiology 2023Quote: ... The supernatant containing Fibril Δ(273-512)-His6 was loaded into a pre-packed 5 mL Ni-NTA column (HisTrap; GE Healthcare) equilibrated with binding buffer ...
-
bioRxiv - Cell Biology 2023Quote: ... Protein samples at concentrations >5 mg/ml were loaded onto a Superdex™ 200 Increase 10/300 GL size exclusion chromatography column (GE Healthcare) in 20 mM Tris pH 8.0 ...
-
bioRxiv - Bioengineering 2024Quote: ... beads were suspended in 0.22 mm filtered PBS with 5 ml (10 units) of PreScission protease (catalog # 27084301; GE healthcare Life Sciences) and incubated overnight at 4°C on a rotospin test tube rotator for on-column PreScission protease cleavage ...
-
bioRxiv - Biochemistry 2024Quote: ... The resulting lysate was filtered through a 0.2 μm nylon filter and loaded onto a prepacked 5 mL HiTrapFF Ni-Sepharose column (GE Healthcare Life Sciences) that had been equilibrated in Buffer A ...
-
bioRxiv - Microbiology 2024Quote: Purified PmSLP-1 and FI were mixed to achieve a final concentration ratio of 5:1 and incubated on ice for 10mins before loading onto a Superdex Increase 200 10/300 GL column (GE Life Sciences). The column was pre-equilibrated in 1X PBS pH 7.4 ...
-
bioRxiv - Genomics 2024Quote: ... Peripheral blood mononuclear cells (PMBCs) were also isolated from 5 ml of blood using the standard Percoll ® (GE Healthcare, Chicago, USA) centrifugation method ...
-
bioRxiv - Cell Biology 2020Quote: LC3B (amino acids 1-120) was expressed in BL21 pLysS DE3 E.coli cells from a pGEX-6P-2 plasmid (GE Healthcare) in 250 ml LB medium ...
-
bioRxiv - Physiology 2022Quote: ... The membrane was incubated for 1 hour at RT in 2% enhanced chemiluminiscence (ECL) prime blocking agent (GE Healthcare, RPN418). Membranes were incubated overnight at 4⁰C in blocking buffer (4% bovine serum albumin (BSA ...
-
bioRxiv - Cell Biology 2020Quote: ... Cleaved protein was applied to a Source 15 Q anion exchange column and eluted with a gradient of 200 mM-300 mM NaCl in 20 mM HEPES (pH 7.0) and 2 mM DTT followed by size exclusion chromatography using a Superdex 200 prepgrade column (GE Healthcare) in 25 mM HEPES (pH 7.5) ...
-
bioRxiv - Biophysics 2020Quote: ... The supernatant was collected and incubated with 2 column volume (for 20 mL supernatant) of Gluthatione Sepharose 4B (GE Healthcare) for 1h30 on a rotating wheel ...
-
bioRxiv - Biochemistry 2020Quote: ... The eluted protein sample was dialyzed against 20 mM Tris-HCl (pH 8.0) and 2 mM CaCl2 (buffer B) and applied to a Mono Q 10/100 GL column (GE Healthcare) equilibrated with buffer B ...
-
bioRxiv - Biophysics 2021Quote: ... Proteins were expressed in Rosetta 2 bacteria and purified by affinity chromatography using a HiTrap™ chelating column (GE Healthcare) according to the manufacturer’s instructions in 50 mM Tris at pH 8.0 ...
-
bioRxiv - Biophysics 2020Quote: ... was expressed in E.Coli Rosetta 2 (DE3) and purified by affinity chromatography over a Sepharose 4B GSH affinity column (GE healthcare) followed by gel filtration over a Hiload Superdex 200 column (GE healthcare) ...
-
bioRxiv - Biochemistry 2021Quote: ... Purified Ycf1p NBD1 and NBD1-R were exchanged into the fluorescence buffer (20 mM Na3PO4, 2% glycerol, 150 mM NaCl, pH 7.3) by size exclusion chromatography (Superdex75, GE Healthcare). MgATP-bound and apo NBD1 and NBD1-R were generated by adding 2 mM MgATP or 2 mM EDTA ...
-
bioRxiv - Cell Biology 2021Quote: ... Cleaved protein was applied to a Source 15 Q anion exchange column and eluted with a gradient of 150 mMà350 mM NaCl in 20 mM Immidazole (pH 8.0) and 2 mM DTT followed by size exclusion chromatography using a Superdex 200 prepgrade column (GE Healthcare) in 25 mM HEPES (pH 7.5) ...
-
bioRxiv - Immunology 2021Quote: ... Nbs and their mixture (1.6 nmol of SARS-CoV-2 RBD mixed with 1.6 nmol of Nbs) were run over a Superdex 75 column (GE healthcare) at a flow rate of 0.5 mL/min with AKTA pure.
-
bioRxiv - Neuroscience 2020Quote: ... Aliquots (2 µl) of the homogenate were used for protein determination with a BCA (bicinchoninic acid) assay kit (GE Healthcare). Samples were prepared with 5X sample buffer (0.25 M Tris-HCl pH6.8 ...
-
bioRxiv - Cell Biology 2021Quote: ... Plasmids encoding for GST fusion proteins of Cobl-like1-411 were generated by subcloning into pGEX-4T-2 (GE Healthcare). A plasmid encoding for TrxHis-Cobl-like1-411 was generated by PCR and subcloning into pET-32 (Novagen ...
-
bioRxiv - Immunology 2020Quote: The binding kinetics and affinity of mAbs to SARS-CoV-2 RBD were analyzed by SPR (Biacore T200, GE Healthcare). Specifically ...
-
bioRxiv - Biochemistry 2020Quote: ... MRPP1 and 2 formed a complex of ~150 kDa that was further purified by gel-filtration (Superdex 200, GE Healthcare). His6-Δ95 MRPP3 cDNA lacking the N-terminal disordered region was cloned into pMCSG7 vector and expressed and purified ...
-
bioRxiv - Immunology 2020Quote: ... 7.5×104 congenically distinct cells of each sorted memory population were adoptively transferred and tumor-bearing mice were subsequently immunized with 10 μg of GP33-41 and 2 μg of poly(I:C) (GE Healthcare) s.c ...
-
bioRxiv - Biochemistry 2021Quote: All samples were prepared in a total volume of 40 μL in SEC buffer A supplemented with 2 mM DTT and analysed on a Superdex 75 3.2/300 Increase column (GE Healthcare). For the TTP-DCP2 interaction ...
-
bioRxiv - Immunology 2021Quote: ... the protein was diluted with 2-fold volume of 20 mM HEPES with pH 7.0 and loaded on HiTrap SP HP column (GE Healthcare) equilibrated with 100 mM NaCl ...
-
bioRxiv - Immunology 2021Quote: ... fragments or Fabs 2/1.12 or 2/6.14 were either used as analytes or amine immobilized on a CM5 chip in a Biacore 3000 (GE Healthcare) according to the manufacturer’s instructions ...
-
bioRxiv - Bioengineering 2021Quote: HEK293A cells were maintained in Dulbecco’s modified Eagle medium (DMEM) supplemented with 2 mM L-glutamine (GE Healthcare Life Sciences), 10% fetal bovine serum (FBS ...
-
bioRxiv - Immunology 2020Quote: ... Eluted protein was concentrated down to 2 mL for size exclusion chromatography with a Superose6 16/600 column (GE Healthcare) in 10 mM Tris pH8 ...
-
bioRxiv - Cell Biology 2022Quote: Human isoform of amphiphysin 2/BIN1 including exon 11 was expressed in Rosetta 2 bacteria and purified by affinity chromatography using glutathione Sepharose 4B beads according to the manufacturer’s instructions (GE Healthcare) in 50 mM Tris at pH 8.0 ...
-
bioRxiv - Neuroscience 2022Quote: ... Images were taken at 2 second intervals for 1 minute and deconvoluted with Applied Precision softWorx imaging software (GE Healthcare). The microtubule comet tracking and quantification was performed with the MTrackJ plugin in ImageJ/Fiji (Meijering et al. ...
-
bioRxiv - Biophysics 2022Quote: ... the complex was further purified by anion exchange chromatography in presence of 2% CHAPS using the AKTA system (GE Healthcare), flash frozen and stored at −80 °C until use.
-
bioRxiv - Bioengineering 2024Quote: Single-cycle kinetics analysis of CD4-Ig binding to the 16055-ConM-v8.1 SOSIP with C-terminal Spy-tag-2 (ST2) was performed at 25°C on a Biacore T100 (GE Healthcare). 1X HBS-EP containing 10 mM HEPES ...
-
bioRxiv - Biochemistry 2023Quote: ... 150 mM NaCl.) supplemented with 2 mM CaCl2 and loaded onto a Superose6 Increase 10/300 GL column (GE Healthcare) integrated on a high-performance liquid chromatography (HPLC ...
-
bioRxiv - Plant Biology 2023Quote: ... first-strand cDNA was synthesized from 2 µg of total RNA using Ready-to-Go RT-PCR beads (GE healthcare) and an oligo(dT ...
-
bioRxiv - Evolutionary Biology 2023Quote: ... algae were grown for two weeks and harvested using a vacuum filtration with Whatman #2 paper (GE Healthcare 47 mm), washed with distilled water (three times) ...
-
bioRxiv - Microbiology 2023Quote: ... 200 mM NaCl and 2 mM TCEP using a Superdex-200 10/300 GL size-exclusion column from GE Healthcare. All protein concentrations were diluted to 1.7 mg/mL ...
-
bioRxiv - Cell Biology 2024Quote: ... the beads were boiled with 2 × Laemmli’s sample buffer and subjected to immunoblotting using an Amersham ECL Prime Western Blotting Detection System (GE Healthcare).
-
bioRxiv - Biochemistry 2024Quote: ... 50-100 μL of the purified protein samples (concentration ranging 2-15mg/ml) were filtered (with 0.1 μm pore size) and loaded onto a Superdex200 10/300GL column (GE Healthcare) preequilibrated with SEC buffer ...
-
bioRxiv - Molecular Biology 2024Quote: ... the combined peptide containing solutions were passed over pre-equilibrated (50 µl 0.5 % formic acid ) home-made 2-disc Glass microfiber StageTip (disc material: GE Healthcare; pore size ...
-
bioRxiv - Neuroscience 2024Quote: ... 2 µg of protein was immobilized on a nitrocellulose membrane (Amersham) by filtration using a slot blot apparatus (GE Healthcare). The membrane was blocked with 5% skimmed milk and probed with MJFR-14-6-4-2 (Abcam ...
-
bioRxiv - Cancer Biology 2022Quote: ... 1:100 Dako #M7248) (overnight, 4 °C) and biotinylated secondary antibodies (HRP anti-mouse and HRP anti-rabbit, 1:200, GE Healthcare (2h at room temperature). Target proteins were detected with the ABC Kit and the DAB kit (Vector Laboratories).
-
bioRxiv - Cell Biology 2020Quote: ... This protein was coupled to a 1 ml packed column volume of NHS-activated Sepharose 4 Fast Flow resin (GE Healthcare Life Sciences, Marlborough, MA). 10 ml of serum was diluted 1:1 in binding buffer (20mM Tris ...
-
bioRxiv - Molecular Biology 2020Quote: ... at a 1:1000 dilution in 3% milk overnight at 4°C before incubation with secondary HRP-linked sheep anti mouse (NA931-1ML, GE Healthcare Life Sciences, Buckinghamshire, UK) at a 1:3000 dilution in 5% milk for 1 hour at room temperature ...
-
bioRxiv - Pathology 2021Quote: ... 250 μg of total protein was loaded on a 13 cm Immobiline dry-strip (pH 4-7, M/s. GE Healthcare Life Sciences, Amersham, UK), on a rehydration tray ...
-
bioRxiv - Biochemistry 2021Quote: ... Secreted protein was captured by two round of batch absorption (BA) with 4 mL/L of pre-equilibrated Ni Sepharose beads (GE Healthcare, Cat #17-5318-01). The bound beads were transferred to gravity flow column and sequentially washed with 30 CVs Wash Buffer (50 mM HEPES 7.5 ...
-
bioRxiv - Plant Biology 2022Quote: ... chromosomal DNA was purified and amplified to 5.4 - 7.9 μg by multiple displacement amplification (Supplementary Table 3) using an Illustra GenomiPhi V2 DNA Amplification Kit (GE Healthcare, Chalfont St. Giles, United Kingdom) as described by Šimková et al ...
-
bioRxiv - Cell Biology 2023Quote: ... pombe lysate were mixed and incubated at 4 °C for 30 min before the addition of glutathione-sepharose beads (GE Healthcare, Cat#17-0756-01). After 2-hour incubation ...
-
bioRxiv - Biochemistry 2023Quote: ... 55 µg of protein from pulse-labeled samples for analytical gels and 300 µg of protein from unlabeled samples for preparative gels were rehydrated into IPG strips (24 cm, pH 4-7; GE Healthcare, Chalfont St Giles, UK). A Multiphor II (GE Healthcare ...
-
bioRxiv - Immunology 2023Quote: ... Eluate was then cleaved with TEV protease overnight at 4 °C and subsequently purified further by size exclusion chromatography (Superdex 200 26/600 from GE Healthcare; cat # GE28-9893-36) in TBS ...
-
bioRxiv - Molecular Biology 2020Quote: ... Elution buffer was exchanged to standard Tris protein buffer (100 mM Tris and 150 mM NaCl at pH 7.5) with NAP-5 columns (GE Healthcare, Chicago, IL, USA) and samples were concentrated as before.