Labshake search
Citations for GE Life Sciences :
51 - 100 of 6415 citations for B TFIID TATA Box Binding Protein Associated Factor 1 BTAF1 Antibody Biotin since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2020Quote: ... Kinetic constants were determined by the 1:1 Langmuir binding model using Biacore T200 software (GE Healthcare).
-
bioRxiv - Microbiology 2020Quote: ... The resulting data were fit to a 1:1 binding model using Biacore Evaluation Software (GE Healthcare). His-tagged SARS-CoV RBD-SD1 was immobilized to an NiNTA sensorchip to a level of ∼350 RUs using a Biacore X100 and the same running buffer listed above ...
-
bioRxiv - Immunology 2021Quote: ... Data were fit to a 1:1 Langmuir binding model using Biacore insight evaluation software (GE Healthcare). SARS-CoV-1 S1 sensograms were also fit to a two-state kinetics ...
-
bioRxiv - Cell Biology 2021Quote: ... Sites of primary antibody binding were determined using an enhanced chemiluminescence system (GE Healthcare, Pittsburgh, PA, USA). Horseradish peroxidase (HRP)-conjugated secondary antibodies (Santa Cruz Biotechnology ...
-
bioRxiv - Neuroscience 2020Quote: ... Binding was detected with an anti-mouse Cy-3 and anti-rabbit Cy-5 antibodies (GE Healthcare). Blots were scanned using a Typhoon 5 (GE Healthcare ...
-
bioRxiv - Biochemistry 2020Quote: The antibodies binding properties were analyzed at 25 °C on a Biacore ™ 8K instrument (GE Healthcare) using 10mM HEPES pH 7.4 ...
-
bioRxiv - Biochemistry 2021Quote: ... anti-EGFR antibody (#MI-12-1, MBL), anti-GFP antibody (#M-048-3, MBL) and Protein A-Sepharose (GE Healthcare) were used for immunoprecipitation ...
-
bioRxiv - Molecular Biology 2019Quote: ... Protein A and Protein G beads mix (1:1) (GE Healthcare) were washed with HEMG100 ...
-
bioRxiv - Microbiology 2020Quote: ... Untagged His-GmPUB13 U-box and Avr1d were loaded on a superdex 200 gel-filtration column (GE Healthcare) and eluted in superdex buffer (20 mM Tris [pH 8.0] ...
-
bioRxiv - Biophysics 2022Quote: ... recombinant proteins were purified twice by binding to and eluting from a Ni Sepharose 6 Fast Flow column (GE Healthcare) and a HiTrap Heparin HP column (GE Healthcare ...
-
bioRxiv - Cancer Biology 2021Quote: ... data were fitted using a kinetic 1:1 binding model using the Biacore T200 Evaluation Software (GE Healthcare).
-
bioRxiv - Bioengineering 2020Quote: ... Data were fitted using 1:1 Langmuir binding model within the Biacore 8K analysis software (GE Healthcare #29310604).
-
bioRxiv - Immunology 2022Quote: ... and the resulting data were fitted to a 1:1 binding model using BIAcore 8K Evaluation Software (v3.0.12.15655; GE Healthcare).
-
bioRxiv - Molecular Biology 2019Quote: ... Curves were fitted to a 1:1 binding model using the accompanying Biacore evaluation software (Biacore/GE Healthcare).
-
bioRxiv - Bioengineering 2020Quote: ... Data were fitted with 1:1 Langmuir binding kinetic model using the Biacore 8K analysis software (GE Healthcare).
-
bioRxiv - Bioengineering 2023Quote: ... Data were fit with 1:1 Langmuir binding model within the Biacore 8K analysis software (GE Healthcare #29310604).
-
bioRxiv - Immunology 2022Quote: ... The resulting data were fit to a 1:1 binding model using the Biacore Evaluation Software (GE Healthcare).
-
bioRxiv - Microbiology 2021Quote: ... The apparent binding affinity (KD) for individual antibody was calculated using BIAcore® 3000 Evaluation Software (GE Healthcare).
-
bioRxiv - Immunology 2022Quote: ... The binding curves were analysed using a kinetic binding model supplied with Biacore Evaluation Software (GE Healthcare).
-
bioRxiv - Biophysics 2022Quote: ... The biotinylated protein was separated from excess biotin on a Superdex 200 Increase 10/300 gel filtration column (GE Healthcare) equilibrated in 1x PBS buffer (10 mM Na2HPO4·7H2O ...
-
bioRxiv - Cell Biology 2020Quote: ... GFP fusions were immunoprecipitated using lab-purified GFP binding protein (GBP) (Rothbauer et al., 2008) coupled to NHS-activated Sepharose FastFlow beads (GE Healthcare) using a protocol adapted from (Babiano et al. ...
-
bioRxiv - Microbiology 2021Quote: Kinetic measurements of the DH1047 Fab binding to SARS-CoV and RsSHC014 spike proteins were obtained using a Biacore S200 instrument (Cytiva, formerly GE Healthcare) in HBS-EP+ 1X running buffer ...
-
bioRxiv - Immunology 2022Quote: SPR screening and affinity measurements of monoclonal Fabs binding to SARS-CoV-2 spike proteins were performed using a Biacore S200 instrument (Cytiva, formerly GE Healthcare) in HBS-EP+ 1X running buffer ...
-
bioRxiv - Immunology 2020Quote: ... Ab binding (protein expression) was visualized using Amersham ECL Prime Western blotting detection reagent (GE Healthcare Bio-Sciences AB, Uppsala, Sweden). The following Abs were used in this study ...
-
bioRxiv - Neuroscience 2019Quote: SPR biosensor analysis was used to verify binding between peptides and the PDZ2 domain of FRMPD2 protein using a Biacore 8K instrument (GE Healthcare), as previously described(Zhang et al. ...
-
bioRxiv - Molecular Biology 2021Quote: ... The RNA-protein binding complex was resolved on SDS-PAGE prior to analysis by Coomassie staining and PhosphoImaging (Typhoon FLA 7000, GE Healthcare).
-
bioRxiv - Molecular Biology 2021Quote: ... The protein binding complex was separated on SDS-PAGE prior to analysis by Coomassie staining and Phosphoimaging (Typhoon FLA 7000, GE Healthcare). For pull down with purified PGC-1α protein domains ...
-
bioRxiv - Immunology 2021Quote: ... was used to elute the protein using a binding buffer with 400 mM imidazole followed by size exclusion chromatography on a Superdex75 16/600 (GE Healthcare) column equilibrated in binding buffer ...
-
bioRxiv - Bioengineering 2024Quote: ... SpyTag003-linked non-antigen binding proteins) were injected onto a pre-equilibrated HiLoad 16/600 Superdex 200 pg column (GE Healthcare), or a HiLoad 16/600 Superdex 75 pg column (SUMO-SpyTag003 and affibodies ...
-
bioRxiv - Microbiology 2020Quote: ... The response data were fit to a 1:1 binding model using Biacore™ Insight evaluation software (GE Healthcare). For Fab competition experiments (Figure S8) ...
-
bioRxiv - Biochemistry 2022Quote: ... The resulting data were fitted to a 1:1 binding model using the Biacore 8K Evaluation software (GE Healthcare). The equilibrium dissociation constants (binding affinity ...
-
bioRxiv - Microbiology 2021Quote: ... Data were double reference-subtracted and fit to a 1:1 binding model using Biacore Evaluation Software (GE Healthcare).
-
bioRxiv - Neuroscience 2020Quote: ... Sensorgrams were fitted using 1:1 binding model and kinetic constants determined using Biacore T200 Evaluation software (GE Healthcare).
-
bioRxiv - Immunology 2022Quote: ... The resulting data were fitted to a 1:1 binding model using the Biacore 8K Evaluation software (GE Healthcare). To determine the levels of nanobody competition with the human ACE2 and VHH72 of known epitope specificity ...
-
bioRxiv - Microbiology 2020Quote: ... Proteins of interest were detected with protein-specific primary antibodies and HRP-coupled secondary antibodies by enhanced chemiluminescence (GE Healthcare) and imaged using X-ray films or with Fusion Capture Advance FX7 16.15 (Peqlab).
-
bioRxiv - Immunology 2022Quote: The IgG antibody or Fab binding properties were analyzed at 25 °C using a Biacore 8K instrument (GE Healthcare) with 10 mM HEPES pH 7.4 ...
-
bioRxiv - Cell Biology 2024Quote: ... Visualization of the antibody binding sites was achieved using Amersham ECL Prime Western Blotting (GE Healthcare UK Ltd, RPN2232) according to the manufacturer’s protocol.
-
bioRxiv - Molecular Biology 2022Quote: ... The protein solutions were further diluted with buffer B and eIF4A1 fractions subjected to a ResourceQ (GE Healthcare) anion exchange column ...
-
bioRxiv - Developmental Biology 2021Quote: ... antibodies and protein G Mag sepharose (GE Healthcare) overnight at 4°C ...
-
bioRxiv - Immunology 2021Quote: ... Proteins were further purified and excess biotin removed from proteins biotinylated in vitro by size exclusion chromatography (Superdex 75 or 200 column [GE Healthcare]) in HBS-EP ...
-
bioRxiv - Immunology 2020Quote: ... Proteins were further purified and excess biotin removed from proteins biotinylated in vitro by size exclusion chromatography (Superdex 75 or 200 column [GE Healthcare]) in HBS-EP ...
-
bioRxiv - Biophysics 2022Quote: ... 3 volumes of 1 mg/mL affinity-purified antibody was gently rotated with 1 volume Protein A Sepharose beads (GE Healthcare) overnight at 4°C or 1 hour at room temperature ...
-
bioRxiv - Cancer Biology 2023Quote: ... 1 mg lysates were incubated with the appropriate agarose-conjugated primary antibody for 3-4 h at 4°C or with unconjugated antibody (1-2 mg) overnight at 4°C followed by 1 h incubation with Protein G Sepharose beads (GE Healthcare). Immuno-complexes were washed four times with NETN buffer (20 mM Tris ...
-
bioRxiv - Microbiology 2021Quote: ... The protein-antibody complexes were captured with protein-G coupled Sepharose beads (GE Healthcare) by incubation at 4 °C for 1 h ...
-
bioRxiv - Cancer Biology 2022Quote: ... Equal amounts of protein from each sample were added to 50 µl of precleaned CaM binding beads (GE Healthcare, 17-0529-01) in 300 to 500 µl of 1% TX100-TNM lysis buffer and incubated with rotation at 4°C overnight (16-18 hours) ...
-
bioRxiv - Immunology 2020Quote: ... The equilibrium Kd was determined by fitting the data to a steady-state 1:1 binding model using Biacore X100 Evaluation software version 2.0 (GE Healthcare).
-
bioRxiv - Microbiology 2020Quote: ... and the kinetic parameters were obtained by globally fitting the double-reference subtracted data to a 1:1 binding model with mass transport limitation using Biacore T200 Evaluation software v 3.1 (GE Healthcare). The dissociation rate constant (kd ...
-
bioRxiv - Biochemistry 2022Quote: ... fits of the sensorgrams were determined using a 1:1 binding model (Langmuir) using Biacore T200 Evaluation Software 3.1 (GE Healthcare).
-
bioRxiv - Immunology 2022Quote: ... and the raw data curves were fitted to a 1:1 binding model using Biacore 8K Evaluation Software (GE Healthcare).
-
bioRxiv - Biophysics 2023Quote: ... and the binding affinities were obtained using a 1:1 (Langmuir) binding fit model with Biacore T200 Evaluation software version 3.2 (GE Healthcare).