bioRxiv - Cell Biology 2024Quote: ... 4 × 104 MDM cells were seeded on glow discharged and UV-light sterilized holey carbon grids (R2/2, Au, 200 mesh, Quantifoil), which were placed in a glass-bottomed ‘microwell’ of 35-mm MatTek dish (MatTek ...
-
bioRxiv - Cell Biology 2024Quote: ... 3 µl of cell suspension was applied to a freshly grown discharged holey carbon grid (Quantifoil® #200, R2/2). Grids were immediately blotted from the back side using Whatman filter paper #1 (GE Healthcare ...
-
bioRxiv - Biophysics 2023Quote: A 3 µL aliquot of purified CDTbD623A/D734Aprotein sample at a concentration of 30 µM was applied to a glow discharged QUANTIFOIL® copper R 1.2/1.3 grid with a 2 nm thin extra carbon layer (QUANTIFOIL, GMBH). For calcium depleted CDTb (28 µM) ...
-
bioRxiv - Biophysics 2023Quote: ... 3 or 3.5 μl of LRRK2RCKW:inhibitor:E11 DARPin complex were applied to a glow-discharged UltraAuFoil Holey Gold 200 mesh R2/2 grid (Quantifoil, Catalog # Q250AR2A) and incubated in a FEI Vitrobot IV chamber at 4°C and 95% humidity for 20 sec ...
-
bioRxiv - Biochemistry 2023Quote: 2.4 µL of sample were applied to a freshly glow discharged 200-mesh Cu + 2 nm C R1.2/1.3 grid (Quantifoil Micro Tools), blotted for 6 s at 100% humidity ...
-
bioRxiv - Biochemistry 2022Quote: ... 2–2.5 µl of protein solution was applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3 Au 200 mesh). The endogenous samples were applied onto grids containing an additional thin layer of continuous carbon support (Quantifoil R1.2/1.3 Cu 200 mesh + 2 nm C ...
-
bioRxiv - Microbiology 2022Quote: ... and 4 µl of the mixture was applied to a glow-discharged holey-carbon copper EM grid (R2/1 or R2/2, Quantifoil). The grid was automatically blotted from the backside for 4-6 s in a Mark IV Vitrobot by using a Teflon sheet on the front pad ...
-
bioRxiv - Microbiology 2022Quote: ... mixed with 10 nm protein A-coated colloidal gold (Aurion) and applied onto a glow-discharged EM grid (200 mesh, R 2/1, Quantifoil) prior to plunge-freezing with a Leica EM GP2 automatic plunge-freezer.
-
bioRxiv - Biochemistry 2023Quote: ... 3 µL of each sample was applied to glow-discharged (PELCO easiGlow, 15 mA, 2 min) holey carbon grid (Quantifoil R1.2/1.3 on gold or copper 200 mesh support) ...
-
bioRxiv - Cell Biology 2024Quote: HeLa WT cells or HeLa cells stably expressing Apaf1-GFP were plated on 200 mesh gold EM grids with a holey carbon film R2/2 (Quantifoil). HeLa WT cells were transfected with Apaf1-SNAP-tag ...
-
bioRxiv - Microbiology 2024Quote: ... and 4 µl of the mixture was applied to a glow-discharged holey-carbon copper EM grid (R2/1 or R2/2, [Quantifoil]). The grid was automatically blotted from the backside for 4-6 s in a Mark IV Vitrobot by using a Teflon sheet on the front pad ...
-
bioRxiv - Microbiology 2024Quote: ... A 4.5 µL droplet of the culture was applied to glow discharged copper grids (Quantifoil R2/2, Quantifoil Micro Tools) and blotted for 2.5 s in a 95% humidity chamber at 20 °C ...
-
bioRxiv - Neuroscience 2024Quote: Plunge-freezing VLPs: 3 µL of crude enriched VLP resuspension was applied to Holey copper R2/2 grids (Quantifoil GmBH) glow-discharged at 5mA 30s using an EasiGlow system (Pelco) ...
-
bioRxiv - Microbiology 2024Quote: ... We initially prepared frozen-hydrated viruses deposited onto Quantifoil R2/2 or R1.2/1.3 grids (Quantifoil Micro tools GmbH, Germany) or glow discharged Lacey grid (Ted Pella Inc. ...
-
bioRxiv - Microbiology 2024Quote: ... A 4.5 µL droplet of the culture was applied to glow discharged copper grids (Quantifoil R2/2, Quantifoil Micro Tools) and blotted for 2.5 s in a 95% humidity chamber at 20 °C ...
-
bioRxiv - Biochemistry 2024Quote: ... was applied to glow-discharged (GloQube® Plus, Quorum, UK) Quantifoil R1.2/1.3 or R2/2 mesh 200 copper holey carbon grid (Quantifoil, Germany), blotted under 100% humidity at 4°C for 6–8 s ...
-
bioRxiv - Microbiology 2024Quote: ... The mixture was added onto glow-discharged copper R2/2 Quantifoil holey carbon grids (Quantifoil Micro Tools GmbH, Jena, Germany). Grids were blotted for 6-8 seconds (under 100% humidity conditions ...
-
bioRxiv - Biochemistry 2024Quote: ... 1 µL of 10 µM 11-16Ub[K48]-GFP-35 was pipetted on a holey carbon R2/2 Cu200 grid (Quantifoil) that was plasma cleaned by a SCD005 sputter coater (Bal-Tec ...
-
bioRxiv - Cell Biology 2024Quote: ... 3 µL of LRRK2RCKW:RN277:E11 DARPin complex were applied to a glow-discharged UltraAuFoil Holey Gold 200 mesh R2/2 grid (Quantifoil, Q250AR2A) and incubated in a FEI Vitrobot IV chamber at 4 °C and 95 % humidity for 20 sec ...
-
bioRxiv - Biochemistry 2024Quote: HeLa cells stably expressing either HRS-mScarlet or HRS-mCherry were grown on 200 mesh gold EM grids with a holey carbon film R2/2 (Quantifoil). Cells were incubated with 50 ng/ml EGF- Alexa 647 ...
-
bioRxiv - Biophysics 2020Quote: ... An aliquot of 4 μl pY39 α-syn fibril solution was applied to a glow-discharged carbon electron microscope grid (Quantifoil R1.2/1.3, 300 mesh). After 10 s of incubation ...
-
bioRxiv - Molecular Biology 2021Quote: The purified GIP1-42–GIPR–Gs–Nb35 complex at a concentration of 6-7 mg/mL was mixed with 100 μM GIP1-42 at 4 C and applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3, Au 300 mesh) that were subsequently vitrified by plunging into liquid ethane using a Vitrobot Mark IV (ThermoFisher Scientific) ...
-
bioRxiv - Molecular Biology 2021Quote: The purified tirzepatide–GIPR–Gs–Nb35 complex at a concentration of 18-20 mg/mL was mixed with 100 μM tirzepatide at 4°C and applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3, Au 300 mesh) that were subsequently vitrified by plunging into liquid ethane using a Vitrobot Mark IV (ThermoFisher Scientific) ...
-
bioRxiv - Molecular Biology 2021Quote: The purified non-acylated tirzepatide–GIPR–mini-Gs–Nb35 complex at a concentration of 14-16 mg/mL was mixed with 100 μM non-acylated tirzepatide at 4°C and applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3, Au 300 mesh) that were subsequently vitrified by plunging into liquid ethane using a Vitrobot Mark IV (ThermoFisher Scientific) ...
-
bioRxiv - Molecular Biology 2021Quote: The purified peptide 20–GIPR–Gs–Nb35 complex at a concentration of 5-6 mg/mL was mixed with 100 μM peptide 20 at 4°C and applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3, Au 300 mesh) that were subsequently vitrified by plunging into liquid ethane using a Vitrobot Mark IV (ThermoFisher Scientific) ...
-
bioRxiv - Molecular Biology 2021Quote: The purified peptide 20–GCGR–Gs–Nb35 complex at a concentration of 12-14 mg/mL was mixed with 100 μM peptide 20 at 4°C and applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3, Au 300 mesh) that were subsequently vitrified by plunging into liquid ethane using a Vitrobot Mark IV (ThermoFisher Scientific) ...
-
bioRxiv - Biochemistry 2023Quote: ... Four microliters of purified Cx36 proteins (4-6 mg/ml) were applied onto a negatively glow-discharged holey carbon grid (Quantifoil R1.2/1.3 Cu 300 mesh). For samples involving Cx36-WT ...
-
bioRxiv - Biochemistry 2022Quote: ... or AE1-Niflumic acid at 5 mg/ml were applied to glow-discharged holey carbon EM grids (Quantifoil 300 copper mesh, R1.2/1.3) in an EM-GP2 plunge freezer (Leica) ...
-
bioRxiv - Biochemistry 2021Quote: ... 3 μL of protein solution at 5 mg/mL (with 0.025% DDM) was applied onto a glow-discharged holey carbon grid (Quantifoil, 300 mesh, R1.2/1.3). Excess samples were blotted for 5.0 s with a blotting force of 3 ...
-
bioRxiv - Biophysics 2021Quote: ... 2.5 μL of each purified CCKAR–G protein complex was applied individually onto the glow-discharged holey carbon grids (Quantifoil, Au300 R1.2/1.3) in a Vitrobot chamber (FEI Vitrobot Mark IV) ...
-
bioRxiv - Biochemistry 2024Quote: ... 3.5 μL of this protein-DNA mix were applied to 300-mesh copper R2/1 Quantifoil Holey Carbon Grids (Quantifoil Micro Tools GmbH) that had been freshly glow discharged for 30 seconds at 25 mA in a GloQube Glow Discharge System (Quorum Technologies ...
-
bioRxiv - Molecular Biology 2022Quote: The purified complex samples (3 μL at 5-8 mg/mL) were applied to glow-discharged holey grids (Quantifoil R1.2/1.3, 300 mesh) and subsequently vitrified using a Vitrobot Mark IV (ThermoFisher ...
-
bioRxiv - Biophysics 2020Quote: ... samples were stored on ice and applied to the cryo-grids (2 nm precoated Quantifoil R3/3 holey carbon supported grids) at a concentration of 10 μM and vitrified using a Vitrobot Mark IV (FEI) ...
-
bioRxiv - Plant Biology 2021Quote: ... 3 µl of suspended cells in culture medium were applied to the front side of glow-discharged R2/2 carbon-coated copper grids (Quantifoil MicroTools), with additional 1 µL cells added to the back side ...
-
bioRxiv - Microbiology 2020Quote: ... 3 μL of the sample mixture was applied to a freshly glow-discharged copper R2/2 200 grid (Quantifoil Micro Tools), pre-blotted for 30 seconds ...
-
bioRxiv - Biochemistry 2021Quote: ... Three microliters of the protein solution were applied on a glow-discharged holey carbon grids (200 mesh Quantifoil R2/2 molybdenum), which had been treated with H2 and O2 mixtures in a Solarus plasma cleaner (Gatan ...
-
bioRxiv - Microbiology 2023Quote: ... sample were placed onto glow-discharged Quantifoil R2/1 Cu300 holey carbon grids (1 µm spacing, 2 µm holes, copper mesh) (Quantifoil, Germany), blotted for 3.5 s before flash-freezing in liquid ethane using a Vitrobot mark IV (FEI ...
-
bioRxiv - Biophysics 2023Quote: ... 3 to 3.5 μl of complex was applied to a glow-discharged UltrAuFoil Holey Gold 200 mesh R2/2 grid (Quantifoil, Catalog # Q250AR2A) and incubated in a FEI Vitrobot IV chamber at 4°C and 95% humidity for 20 sec ...
-
bioRxiv - Cell Biology 2022Quote: ... The IL-11Δ10/IL-11RαD1-D3/gp130D1-D3 complex (0.5 mg/mL) was blotted onto UltrAuFoil grids (R2/2, Quantifoil Micro Tools GmbH) that had been subjected to glow discharge (15 mA for 30 s) ...
-
bioRxiv - Biochemistry 2024Quote: ... 3 µL of suspended cells in culture medium were applied to the front side of glow-discharged R2/2 carbon-coated copper grids (Quantifoil MicroTools), with additional 1 µL cells added to the back side ...
-
bioRxiv - Cancer Biology 2024Quote: ... or 0.5 mg/ml of RanGTP•selinexor-XPO1•ASB8ΔN16•ELOB/C supplemented with 2-fold excess ASB8ΔN16-ELOB/C and selinexor) was applied to a 400-mesh copper grid (Quantifoil R1.2/1.3). For unliganded XPO1 ...
-
bioRxiv - Biophysics 2020Quote: ... The WT and Y222F MTs were applied to lacey carbon grids (Agar Scientific AGS166-4 400 mesh copper grids) and holey carbon grids (Quantifoil R1.2/1.3 300 mesh copper grids) immediately after application of glow discharge to the grids ...
-
bioRxiv - Microbiology 2021Quote: ... 5 µl of the cell suspension was placed on freshly glow-discharged (for ∼25 s) holey carbon grids (Quantifoil Cu R2/1, 200 mesh). The grids were front blotted with Whatman filter paper and rapidly frozen in liquid ethane ...
-
bioRxiv - Biophysics 2021Quote: ... 3 μL of the purified lasmiditan–5-HT1F–Gi complex at concentration ∼15 mg/ml were applied onto a glow-discharged holey carbon grid (Quantifoil R1.2/1.3 Au 300). Grids were plunge-frozen in liquid ethane using Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Biophysics 2023Quote: ... 3 μL of purified mGlu5 (with the different ligands) at 5 mg/ml was applied on glow-discharged holey carbon gold grids (Quantifoil R1.2/1.3, 200 mesh). The grids were blotted using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Molecular Biology 2023Quote: Freshly purified ZorAB sample was concentrated to 2-3 mg/mL and 2.7 μL protein was applied onto the glow-discharged (30 s, 5 mA) grids (Quantifoil R0.6/1 300 mesh Au) and plunge-frozen into liquid ethane using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Biophysics 2021Quote: 3 μl of the human sperm sample were applied to glow discharged copper R2/2 200-mesh holey carbon grid (Quantifoil Micro Tools) and plunge frozen in liquid ethane using an automatic plunge freezer (Vitrobot ...
-
bioRxiv - Molecular Biology 2021Quote: ... 3 μL aliquots of the cell suspension were applied to glow-discharged R2/2 200 mesh copper Quantifoil grids (Quantifoil Micro Tools), the sample was pre-blotted for 30 seconds ...
-
bioRxiv - Molecular Biology 2021Quote: ... After another 3 min at 37 °C the termination complexes were placed on ice for 15 min and subsequently applied to Quantifoil R2/2 holey carbon grids (Quantifoil Micro Tools) either coated with a thin continuous carbon film or with graphene oxide flakes (Sigma-Aldrich) ...
-
bioRxiv - Cell Biology 2021Quote: ... 4 µl of the solution was applied to a glow-discharged (30s at 35 mA) copper R2/2 holey carbon grid (Quantifoil Micro Tools). After removing excess liquid by blotting the grid from the back side with Whatman filter paper for 2 s ...