Citations for Quantifoil Micro Tools :
101 - 150 of 509 citations for 5 Bromo 2 Tert Butyldimethylsilyl 4 Methylthiazole since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2022Quote: ... 3 mm gold EM finder grids with a perforated carbon film (R 2/2, 200 mesh) were purchased from Quantifoil (AU G200F1 finder ...
-
bioRxiv - Molecular Biology 2020Quote: Samples were diluted to a concentration of 60-65 nM for the Pol II-U1 snRNP complex and 2 μl was applied to each side of the R2/2 UltrAuFoil grids (Quantifoil) that had been glow-discharged for 100 s ...
-
bioRxiv - Microbiology 2020Quote: ... 105 fluorescence-stained cells were deposited on the surface of Au-G200F1 finder grids coated with holey carbon (R 2/2; Quantifoil) and functionalized with Poly-L-Lysine (Merck ...
-
bioRxiv - Biophysics 2021Quote: ... 3.5 μL of sample were applied to glow-discharged 2/2 Quantifoil holey carbon grids (Quantifoil Micro Tools GmbH, Germany) and plunged frozen in liquid ethane with a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Cell Biology 2023Quote: ... 150 or 200 mesh gold holey carbon grids (R 2/2, #N1-C16nAu15-01 and #N1-C16nAu20-01, respectively) were purchased from Quantifoil Micro Tools and glow discharged for 2 min in an ELMO glow discharge unit (Agar Scientific ...
-
bioRxiv - Biochemistry 2024Quote: ... 3 μL of hexapeptide sample were applied to glow-discharged Quantifoil R 2/2 grids (Quantifoil Micro tools GmbH, Germany), blotted for 1 second ...
-
bioRxiv - Biochemistry 2022Quote: R2/2 holey carbon supported copper grids (Quantifoil) coated with a 2nm thin carbon layer were treated as described (A ...
-
bioRxiv - Biochemistry 2020Quote: ... QF AU-200 mesh R2/2 grids (Quantifoil) were glow-discharged and placed into a 6-well tissue culture plate well containing 2 mL of cell culture medium for at least 1 h before cell seeding ...
-
bioRxiv - Microbiology 2022Quote: ... gold finder grids (Au NH2 R2/2, Quantifoil) containing infected amoebae were vitrified by back-blotting (Teflon ...
-
bioRxiv - Biochemistry 2023Quote: ... UltrAufoil Au 200 mesh R2/2 grids (Quantifoil) EM grids were glow-discharged on each side for 90 s at 30 sccm ...
-
bioRxiv - Biochemistry 2020Quote: ... the grids were prepared by applying 3 μl sample on glow-discharged holey carbon grids (Quantifoil Mo 2/2 200 mesh). The sample was ice-embedded using a LEICA EM GP2 (Leica Microsystems ...
-
bioRxiv - Biophysics 2022Quote: ... 10 µl sample was applied onto a glow discharged copper grid coated with holey carbon (R 2/2; Quantifoil, Jena, Germany), and subsequently dipped onto 500 µl deionized H2O for 1 second to clear the sucrose ...
-
bioRxiv - Microbiology 2023Quote: CryoEM samples were prepared by applying 5 μL aliquots of purified PLE PLPs to R2/2 Quantifoil grids and R2/2 Quantifoil grids coated with 2nm ultrathin Carbon (QUANTIFOIL®) that had been glow discharged for 45 seconds in a Pelco Easiglow glow discharging unit ...
-
bioRxiv - Biochemistry 2024Quote: ... of the freshly eluted complex peak solution (4.0 mg/mL) was loaded onto glow-discharged holey carbon grids (Quantifoil 2/2). The procedures for blotting and plunge freezing the grids were the same as above ...
-
bioRxiv - Biophysics 2024Quote: ... samples that have been analyzed here are Influenza A/Hong Kong/1/1968 virions that are produced from MDCK cells grown directly on cryoEM grids (QF AU200 R 2/2, Quantifoil, Germany), infected at a multiplicity of infection <1 ...
-
bioRxiv - Microbiology 2023Quote: ... Gold grids with SiO2 film (Quantifoil, Au 200 mesh, R 1/4) were glow- discharged and coated with 20 µg/ml fibronectin solution for 30 min ...
-
bioRxiv - Biophysics 2021Quote: ... before applying 4 µL of the solution to a glow-discharged (30s at 35 mA) copper R 2/2 200-mesh holey carbon grid (Quantifoil Micro Tools). The grids were blotted manually from the back side with Whatman filter paper #1 for 2-4 s ...
-
bioRxiv - Cell Biology 2022Quote: ... Thin sections of 50μm were obtained using a vibratome and placed onto a glow discharged electron microscopy grid (UltrAuFoil, 200 Au mesh, 2/2 Au film (Quantifoil Micro Tools)) that had been pre-clipped into Autogrids (Thermo Fisher Scientific) ...
-
bioRxiv - Cell Biology 2022Quote: ... A flat-sided planchette was placed flat side upwards and a glow discharged (Glocube, Quorum, Lewes, UK) electron microscopy grids (UltraAuFoil, 200 Au mesh, 2/2 Au film (Quantifoil Micro Tools) placed on top ...
-
bioRxiv - Molecular Biology 2023Quote: ... and samples for cryo-SPA were deposited onto 200-mesh holey carbon grids (Quantifoil Micro Tools, R 2/2 X-103-Cu200) which were first glow-discharged for 2.5 min using an ELMO glow discharge unit (Cordouan Technologies) ...
-
bioRxiv - Biochemistry 2024Quote: Three microliters of liposomes or proteoliposomes were applied to glow discharged Quantifoil R 2/2 grids (Quantifoil Micro Tools GmbH, Jena, Germany) or Lacey grid (Ted Pella inc.) ...
-
bioRxiv - Microbiology 2020Quote: ... loaded onto glow-discharged carbon grids (R2/2, Quantifoil) and plunge-frozen into liquid ethane-propane mix cooled at liquid nitrogen temperatures with a Mark IV Vitrobot(Thermo Fisher Scientific ...
-
bioRxiv - Microbiology 2021Quote: EM grids (G300F1, R2/2 Quantifoil holey carbon, gold) were glow-discharged and treated with bovine fibronectin (20 μg/ml ...
-
bioRxiv - Microbiology 2020Quote: ... loaded onto glow-discharged carbon grids (R2/2, Quantifoil) and plunge-frozen into liquid ethane-propane mix cooled at liquid nitrogen temperatures with a Mark IV Vitrobot maintained at room temperature and 70% humidity ...
-
bioRxiv - Microbiology 2020Quote: ... loaded onto glow-discharged carbon grids (R2/2, Quantifoil) and plunge-frozen into liquid ethane-propane mix cooled at liquid nitrogen temperatures with a FEI Mark IV Vitrobot maintained at room temperature and 70% humidity ...
-
bioRxiv - Cell Biology 2021Quote: Carbon-coated gold TEM grids (Quantifoil NH2A R2/2) were glow-discharged at 2 mA and 1.5–1.8 × 10-1 m bar for 1 min in an ELMO (Cordouan ...
-
bioRxiv - Biochemistry 2022Quote: UltrAuFoil on gold 200 mesh R2/2 grids (Quantifoil) were subjected to micropatterning using the Primo module from Alveole mounted on a Leica DMi8 microscope following the manufacturer procedure ...
-
bioRxiv - Microbiology 2022Quote: ... loaded onto glow discharged carbon grids (R2/2, Quantifoil) and plunge-frozen using a Vitrobot Mark IV (ThermoFisher Scientific) ...
-
bioRxiv - Biochemistry 2024Quote: ... Quantifoil Cu 200 R2/2 holey carbon grids (Quantifoil) were glow discharged negatively for 45 sec before sample application ...
-
bioRxiv - Microbiology 2024Quote: ... copper EM grids (Cu 200 R 2/1, Quantifoil) were used ...
-
bioRxiv - Biophysics 2024Quote: ... Holey carbon grids (Quantifoil Cu 300 mesh, R2/2) were prepared with fiducials by glow-discharging ...
-
bioRxiv - Cell Biology 2023Quote: Carbon-coated gold TEM grids (Quantifoil NH2A R2/2) were glow-discharged at 2 mA and 1.5– × 10−1 m bar for 1 minute in an ELMO (Cordouan ...
-
bioRxiv - Biophysics 2020Quote: The cell suspension in sea water was seeded onto R 2/2 (SiO2) on Au G200F1 finder grids (Quantifoil Micro Tools GmbH, Germany) and incubated with filtered fresh sea water at 18 °C overnight ...
-
bioRxiv - Biochemistry 2022Quote: ... Qualified nucleosomes were then loaded in a freshly glow discharged holey carbon golden grid (Quantifoil™ R 2/2 on 300 gold mesh) (1.0-2.5 µg of nucleosomes were diluted in 40 mM NaCl reconstitution buffer in 3 μL) ...
-
bioRxiv - Molecular Biology 2023Quote: ... The complex was incubated at RT for 20 mins and pipetted onto glowed discharged cryo-EM grids (Quantifoil R 2/2 Au 300). Grids were frozen in liquid ethane by using a Vitrobot Mark IV (ThermoFischer ...
-
bioRxiv - Biophysics 2024Quote: ... 4 × 104 MDM were seeded on glow discharged and UV-light sterilized 200-mesh EM gold grids coated with R 2/2 holey carbon films (Quantifoil Micro Tool GmbH), which were placed in a glass-bottomed ‘microwell’ of 35-mm MatTek dish (MatTek ...
-
bioRxiv - Immunology 2024Quote: ... a 3-μl aliquot was applied onto a glow-discharged QUANTIFOIL® R 1.2/1.3 on Cu 300 mesh grid + 2 nm C Holey Carbon Films with ∼ 2 nm continuous carbon on top (QUANTIFOIL, #C2-C14nCu30-50). The grids were blotted for 2.0 s in 100% humidity at 6°C and plunged into liquid ethane using a VitrobotMkIV (Thermo Fisher Scientific) ...
-
bioRxiv - Biophysics 2021Quote: ... with 12-nm-thick holey R1/4 and R1.2/20 SiO2 film (Quantifoil) were used for the experiments ...
-
bioRxiv - Cell Biology 2021Quote: ... Gold Quantifoil grids (R1/4, Au 200 mesh grid, SiO2, Quantifoil Micro Tools) were glow-discharged and UV irradiated for 30 min for sterilization before being immersed in cell culture medium in 35-mm IBIDI μ-Dish ...
-
bioRxiv - Synthetic Biology 2023Quote: 4 µl of sample was adsorbed onto holey carbon-coated grid (Quantifoil, Germany) that was glow-discharged ...
-
bioRxiv - Neuroscience 2024Quote: ... gold mesh grids with holey R1/4 SiO2 film (Quantifoil Micro Tools GmbH) were glow discharged for 60s at 15 mA using an EasiGlow system ...
-
bioRxiv - Cell Biology 2024Quote: EM grids (Quantifoil R 1/4 Au 200 mesh, Quantifoil Micro Tools GmbH) were glow discharged with an Edwards S150B glow discharger at 30mA for 45sec on both sides of the grid ...
-
bioRxiv - Cell Biology 2024Quote: 4 µl of yeast cells were pipetted on Cu R2/1 grids (Quantifoil), blotted manually from the backside of the grid for ∼4 s and plunge frozen in liquid ethane using a manual plunger ...
-
bioRxiv - Cell Biology 2022Quote: The IL-11Δ10/IL-11RαD1-D3/gp130EC complex (1.5 mg/mL) in the presence of 1-2 mM n-dodecyl β-D-maltoside was blotted onto UltrAuFoil grids (R2/2, Quantifoil Micro Tools GmbH) that had been subjected to glow discharge (15 mA for 30 s) ...
-
bioRxiv - Cell Biology 2022Quote: ... Cells were then seeded onto gold grids (either ‘UltrAuFoil’ 200 Au mesh, R2/2 gold film, or Quantifoil 300 Au mesh, R2/2 carbon film (Quantifoil Micro Tools, Großlöbichau, Germany) and grown to 50 % confluency before plunge freezing ...
-
bioRxiv - Biophysics 2023Quote: ... 0.5 μL L-PEG-L (8 mg/ml) and 0.5 μL Pd(NO3)2 (1 mg/ml) was applied to holey carbon grid (Quantifoil 200 mesh Cu R2/2) which was glow discharged 45 s at 15 mA ...
-
bioRxiv - Biochemistry 2023Quote: ... An aliquot (2 μL) of this polarized vesicle solution was applied onto a glow-discharged holey gold grid (Quantifoil Au R2/2, 400 mesh). After incubating the sample on the grid for 3 minutes at 10 °C with a humidity of 100% ...
-
bioRxiv - Biophysics 2024Quote: ... 2 μL of 2 μM taxol-microtubules were incubated on a glow-discharged holey carbon cryo-EM grid (QuantiFoil, Au 300 R 1.2/1.3) for 30 seconds ...
-
bioRxiv - Microbiology 2020Quote: ... Quantifoil Cu R2/2 Finder grids (Quantifoil Micro Tools GmbH) were glow-discharged at 15mA for 1min ...
-
bioRxiv - Biophysics 2020Quote: UltrAuFoil R2/2 200 mesh TEM grids (Quantifoil Micro Tools) were prepared by 200 second glow discharge in 0.39 mBar of room air using a Pelco easiGlow (Ted Pella) ...