Labshake search
Citations for Quantifoil Micro Tools :
351 - 400 of 618 citations for tert Butyl 2 chloro 5H pyrrolo 3 4 b pyridine 6 7H carboxylate since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Immunology 2023Quote: ... 3 μL of each LNP sample was deposited onto a holey carbon grid that was glow-discharged (Quantifoil R1.2/1.3) and vitrificated using a Vitrobot Mark IV System (FEI/Thermo Scientific ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... 3 μl of the samples were applied to glow-discharged holey carbon EM grids (Quantifoil 300 copper mesh, R1.2/1.3) in an EM-GP2 plunge freezer (Leica) ...
-
bioRxiv - Neuroscience 2024Quote: Protein sample aliquots of 3 µL were applied to glow-discharged holey carbon grids (Quantifoil Au R1.2/R1.3 300 mesh), blotted with filter paper ...
-
bioRxiv - Biophysics 2024Quote: ... Cryo-EM grids were obtained by flash-freezing 3 µL of purified IPNV particles on glow-discharged holey carbon grids (Quantifoil R2/2 ...
-
bioRxiv - Biophysics 2021Quote: ... was applied to glow discharged gold holey carbon 2/1 300-mesh grids (Quantifoil). Grids were blotted for 4 s at 0 force and 2 s wait time before being plunge vitrified in liquid propane using a MarkIV Vitrobot (ThermoFisher) ...
-
bioRxiv - Cell Biology 2020Quote: ... Quantifoil R2/2 or R3.5/1 200 mesh Au grids with carbon film (Quantifoil) were coated with 0.01% poly-L-ornithine solution (Sigma Aldrich ...
-
bioRxiv - Molecular Biology 2021Quote: QUANTIFOIL R 2/1 grids with 2nm carbon layer (Cu 200, Quantifoil Micro Tools) were glow discharged with 25 mA with negative polarity for 60 seconds in a PELCO easiGlow glow discharge unit ...
-
bioRxiv - Biochemistry 2020Quote: Quantifoil R2/2 300 mesh holey carbon copper grids (Quantifoil Micro Tools, Großlöbichau, Germany) were glow-discharged (ELMO Glow Discharge System ...
-
bioRxiv - Cell Biology 2022Quote: MEF were seeded on R2/2 holey carbon on gold grids (Quantifoil or Protochips) coated with fibronectin in a glass bottom dish (Mattek or Ibidi ...
-
bioRxiv - Cell Biology 2022Quote: ... The cells were seeded on EM grids (Quantifoil SiO2 R2/2, 200 mesh, gold) in a 3D printed specimen holder [43] and grown overnight.
-
bioRxiv - Molecular Biology 2023Quote: ... Quantifoil R1.2/1.3 400-square mesh Cu grids with 2 nm continuous carbon (Quantifoil) were glow-discharged for 8 s at 10 mA using a PELCO easiGlow glow discharging system (Ted Pella ...
-
bioRxiv - Biochemistry 2024Quote: ... Three microliters of sample were applied to glow-discharged R2/2 carbon grids (Quantifoil), which were blored for 5 s and at a blot force of 25 and plunge-frozen in liquid ethane with a Vitrobot Mark IV (ThermoFisher ...
-
bioRxiv - Biochemistry 2023Quote: ... Quantifoil R2/2 Cu 400 mesh holey carbon grids (Quantifoil Micro Tools, Jena, Germany) coated with a 0.4 mg/ml graphene oxide suspension (Sigma-Aldrich ...
-
bioRxiv - Biophysics 2024Quote: ... gold grids coated with holey carbon film (300 mesh, R2/2, Quantifoil, Jena, Germany) were glow-discharged and UV-treated for 1 h ...
-
bioRxiv - Molecular Biology 2024Quote: ... and immediately applied to a graphene oxide coated Holey Carbon 2/1 grids (Quantifoil) 83 ...
-
bioRxiv - Cell Biology 2024Quote: ... cells were seeded onto holey carbon gold EM grids (200 mesh, R2/2, Quantifoil) coated with 10 mg/ml fibronectin ...
-
bioRxiv - Biochemistry 2021Quote: ... 3 microlitres of undiluted eluate and of eluate which was diluted 1:2 or 1:4 in buffer A200 were blotted onto holey carbon R 1.2/1.3 copper 300 mesh grids (Quantifoil) and vitrified in liquid ethane using a Vitrobot MarkIV device (Thermofisher) ...
-
bioRxiv - Biophysics 2021Quote: ... 4 µL of aldolase sample were applied on UltrAuFoil R1.2/1.3 300-mesh grids (Quantifoil Micro Tools GmbH) that had been freshly plasma cleaned for 6 seconds at 15 Watts (75% nitrogen/25% oxygen atmosphere ...
-
bioRxiv - Biophysics 2021Quote: ... 4 µL of apoferritin sample were applied on UltrAuFoil R1.2/1.3 300-mesh grids (Quantifoil Micro Tools GmbH) that had been freshly plasma cleaned for 7 seconds at 15 Watts (75% nitrogen/25% oxygen atmosphere ...
-
bioRxiv - Biophysics 2021Quote: The LlCsm RNP and RNP-target RNA samples at approximately 0.5 mg/ml were separately applied in 4 μL volume onto glow-discharged UltrAuFoil 300 mesh R1.2/1.3 grids (Quantifoil), blotted for 3 s at 88% humidity and flash-frozen in liquid ethane using FEI Vitrobot Mark IV ...
-
bioRxiv - Molecular Biology 2022Quote: ... for 15 min before 4 μL of sample was applied to a graphene oxide coated 1.2/1.3 UltrAuFoil grids (Quantifoil) at 4°C under 100% humidity86 ...
-
bioRxiv - Microbiology 2022Quote: ... Aliquots of 4 μL samples were applied to glow-discharged holey carbon girds (Cu, R1.2/1.3, 300 mesh, Quantifoil). The grids were blotted with force 2 for 3 seconds and plunged into liquid ethane using a Vitrobot (FEI Thermo Fisher) ...
-
bioRxiv - Biochemistry 2024Quote: ... 4 uL of the concentrated sample was applied to freshly glow-discharged R2/1 holey carbon grids (Quantifoil), blotted with blot force of 5 for 5 s using a Vitrobot Mark IV (Thermo Fisher ...
-
bioRxiv - Cell Biology 2024Quote: ... 3.5 µl cell suspension applied on glow-discharged (Pelco easiGlow) R1/4 SiO2 gold 200 mesh grids (Quantifoil), blotted for 2 sec from the backside and was plunge-frozen on a Leica EM GP2 plunger at 20 °C ...
-
A distinctive ligand recognition mechanism by the human vasoactive intestinal polypeptide receptor 2bioRxiv - Molecular Biology 2021Quote: The purified PACAP27–VIP2R–Gs complex (3 μL at 3.7 mg per mL) was applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3). Vitrification was performed using a Vitrobot Mark IV (ThermoFisher Scientific ...
-
bioRxiv - Pharmacology and Toxicology 2020Quote: Samples (3 µL) were applied to a glow-discharged UltrAuFoil R1.2/1.3 Au 300 gold foil grids (Quantifoil GmbH, Großlöbichau, Germany) and were flash frozen in liquid ethane using a Vitrobot mark IV (Thermo Fisher Scientific ...
-
Structure of the Human Signal Peptidase Complex Reveals the Determinants for Signal Peptide CleavagebioRxiv - Biochemistry 2020Quote: ... 3 µL samples were applied to freshly glow-discharged Cu 200 Holey Carbon R1.2/1.3 grids (Quantifoil, for samples without FFosC), or Cu 200 Holey Carbon R2/1 grids (Quantifoil ...
-
bioRxiv - Biochemistry 2021Quote: The purified TIP39–PTH2R–Gs complex (3 μL at 8.5 mg per mL) was applied on a glow-discharged holey carbon grid (Quantifoil R1.2/1.3). Vitrification was performed using a Vitrobot Mark IV (ThermoFisher Scientific ...
-
bioRxiv - Molecular Biology 2022Quote: ... The complex (3 μL) was quickly applied on a glow-discharged UltraAuFoil R1.2/1.3 300 mesh holey Au grids (Quantifoil Micro Tools GmbH), blotted with Vitrobot Mark IV (FEI) ...
-
bioRxiv - Biophysics 2024Quote: Approximately 3□μL of the sample solution were put on newly glow-discharged TEM grids (Quantifoil R2/1, Cu, mesh 200) and plunge-frozen in liquid ethane using the Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Biochemistry 2024Quote: ... Cryo-EM grids were prepared by applying 3 µl of concentrated sample onto 400-mesh R1.2/1.3 UltrAuFoil grids (Quantifoil Micro Tools GmbH), which had rendered hydrophilic by glow discharging at 15mA for 60seconds with a PELCO EasyGlow device (TED PELLA ...
-
bioRxiv - Biochemistry 2022Quote: ... stock solution was mixed with 3.5 µL of the KWOCA 4 sample and 3 µl were immediately loaded onto the UltrAuFoil R 1.2/1.3 grids (Au, 300-mesh; Quantifoil Micro Tools GmbH). Prior to sample loading the grids were subjected to Ar/O2 plasma cleaning for 10 s on a Solarus 950 plasma cleaner (Gatan) ...
-
bioRxiv - Neuroscience 2023Quote: ... each time was sequentially blotted 3 times to 300-mesh holey carbon Au R1.2/1.3 grids treated with 25s of glow discharge (Quantifoil, Micro Tools GmbH). Fluorinated Fos-choline-8 (0.65 mM ...
-
bioRxiv - Microbiology 2024Quote: ... The sample solution (3 μl) was applied to glow-discharged (20 mAmp, 30 sec, Quorum GloQube) Quantifoil R1.2/1.3 grids (Quantifoil Micro Tools GmbH), blotted for 5 s using blot force 0 and plunge frozen into liquid ethane using Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Biophysics 2024Quote: Cryo-EM grids for the SIRT7-nucleosome complexes were prepared by applying 3 μL of concentrated sample onto 400-gold mesh R1.2/1.3 Quantifoil grids (Quantifoil Micro Tools GmbH). These grids were rendered hydrophilic by glow discharging at 15 mA for 90 s with a PELCO easiGlow device (Ted Pella Inc.) ...
-
bioRxiv - Biochemistry 2020Quote: ... KBP was diluted to 0.3 mg/ml in KBP dilution buffer and 4 μl were applied to glow-discharged 1.2/1.3 AuFoil gold grids (Quantifoil®). For the third approach ...
-
bioRxiv - Molecular Biology 2021Quote: Purified mtLSU or 55S mitoribosome samples (4 μL) were applied to freshly glow discharged R 3.5/1 holey carbon grids (Quantifoil) that were precoated with a 2-3 nm carbon layer using a Leica EM ACE600 coater ...
-
bioRxiv - Microbiology 2022Quote: ... A 4□μl volume of SsoCsm complex was applied to holey carbon grids (Quantifoil Cu R1.2/1.3, 300 mesh) covered by a graphene oxide layer (27) ...
-
bioRxiv - Biophysics 2024Quote: ... For plunge freezing the cells were pipetted (4 μl) on EM grids (gold/200mesh/R2.2 either UltrAufoil or Quantifoil) in a humidified chamber (98% RH) ...
-
bioRxiv - Cell Biology 2024Quote: ... 3.5 µl of 4 mg/mL proteasomal complexes was applied to glow-discharged R0.6/1 UltrAuFoil 300 mesh grids (Quantifoil) and frozen in liquid ethane using a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Cell Biology 2024Quote: ... For plunge freezing the cells were pipetted (4 µl) on EM grids (gold/200mesh/R2.2 either UltrAufoil or Quantifoil) in a humidified chamber (98% RH) ...
-
bioRxiv - Molecular Biology 2021Quote: ... and applied onto freshly glow-discharged 200 square mesh Ultrafoil R2/2 gold grids (Quantifoil). The samples were plunge-frozen with a FEI Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Microbiology 2021Quote: ... Freshly glow-discharged finder gold quantifoil grids (200 mesh R2/2 – Quantifoil MicroTools GmbH, Germany) were sterilized in 70% EtOH and placed in a glass-bottomed MatTek dish (MatTek Corporation ...
-
bioRxiv - Microbiology 2021Quote: ... were applied to freshly washed and glow-discharged R2/2 holey carbon copper grids (Quantifoil). The grids were manually back blotted for 2 to 3s with filter paper ...
-
bioRxiv - Biochemistry 2022Quote: ... Before spotting onto R2/1 grids with an extra 2 nm carbon layer (Quantifoil, Inc), the complex was diluted to a final concentration of ∼100 nM and a 5-fold excess of Met-tRNAiMet ...
-
bioRxiv - Biochemistry 2021Quote: ... Cryo-EM grids were prepared using glow discharged R2/2 Cu 200 mesh grids (Quantifoil) pre-floated onto custom-made 2.9 nm continuous carbon film ...
-
bioRxiv - Neuroscience 2022Quote: Holey copper or molybdenum EM grids (Quantifoil R 2/1 200 mesh; Quantifoil, Jena, Germany) were glow discharged (Harrick Plasma cleaner PDC-3XG ...
-
bioRxiv - Molecular Biology 2023Quote: ... 3.5 μL) were applied to precoated (2 nm) R1.2/1.3 carbon-supported copper grids (Quantifoil), blotted for 4-5 s at 4°C ...
-
bioRxiv - Biochemistry 2024Quote: ... 3.5 µL were applied to freshly glow-discharged R 2/1 holey carbon grids (Quantifoil) at 4 °C and 95% humidity ...
-
bioRxiv - Cell Biology 2024Quote: ... Cells were seeded onto glow discharged cryo-EM grids (Quantifoil 2/1, 200 mesh, Au) overnight ...