Labshake search
Citations for Quantifoil Micro Tools :
201 - 250 of 618 citations for tert Butyl 2 chloro 5H pyrrolo 3 4 b pyridine 6 7H carboxylate since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biophysics 2021Quote: ... with 12-nm-thick holey R1/4 and R1.2/20 SiO2 film (Quantifoil) were used for the experiments ...
-
bioRxiv - Cell Biology 2021Quote: ... Gold Quantifoil grids (R1/4, Au 200 mesh grid, SiO2, Quantifoil Micro Tools) were glow-discharged and UV irradiated for 30 min for sterilization before being immersed in cell culture medium in 35-mm IBIDI μ-Dish ...
-
bioRxiv - Synthetic Biology 2023Quote: 4 µl of sample was adsorbed onto holey carbon-coated grid (Quantifoil, Germany) that was glow-discharged ...
-
bioRxiv - Neuroscience 2024Quote: ... gold mesh grids with holey R1/4 SiO2 film (Quantifoil Micro Tools GmbH) were glow discharged for 60s at 15 mA using an EasiGlow system ...
-
bioRxiv - Cell Biology 2024Quote: EM grids (Quantifoil R 1/4 Au 200 mesh, Quantifoil Micro Tools GmbH) were glow discharged with an Edwards S150B glow discharger at 30mA for 45sec on both sides of the grid ...
-
bioRxiv - Cell Biology 2024Quote: 4 µl of yeast cells were pipetted on Cu R2/1 grids (Quantifoil), blotted manually from the backside of the grid for ∼4 s and plunge frozen in liquid ethane using a manual plunger ...
-
bioRxiv - Cell Biology 2022Quote: The IL-11Δ10/IL-11RαD1-D3/gp130EC complex (1.5 mg/mL) in the presence of 1-2 mM n-dodecyl β-D-maltoside was blotted onto UltrAuFoil grids (R2/2, Quantifoil Micro Tools GmbH) that had been subjected to glow discharge (15 mA for 30 s) ...
-
bioRxiv - Cell Biology 2022Quote: ... Cells were then seeded onto gold grids (either ‘UltrAuFoil’ 200 Au mesh, R2/2 gold film, or Quantifoil 300 Au mesh, R2/2 carbon film (Quantifoil Micro Tools, Großlöbichau, Germany) and grown to 50 % confluency before plunge freezing ...
-
bioRxiv - Biophysics 2023Quote: ... 0.5 μL L-PEG-L (8 mg/ml) and 0.5 μL Pd(NO3)2 (1 mg/ml) was applied to holey carbon grid (Quantifoil 200 mesh Cu R2/2) which was glow discharged 45 s at 15 mA ...
-
bioRxiv - Biochemistry 2023Quote: ... An aliquot (2 μL) of this polarized vesicle solution was applied onto a glow-discharged holey gold grid (Quantifoil Au R2/2, 400 mesh). After incubating the sample on the grid for 3 minutes at 10 °C with a humidity of 100% ...
-
bioRxiv - Biophysics 2024Quote: ... 2 μL of 2 μM taxol-microtubules were incubated on a glow-discharged holey carbon cryo-EM grid (QuantiFoil, Au 300 R 1.2/1.3) for 30 seconds ...
-
bioRxiv - Microbiology 2020Quote: ... Quantifoil Cu R2/2 Finder grids (Quantifoil Micro Tools GmbH) were glow-discharged at 15mA for 1min ...
-
bioRxiv - Biophysics 2020Quote: UltrAuFoil R2/2 200 mesh TEM grids (Quantifoil Micro Tools) were prepared by 200 second glow discharge in 0.39 mBar of room air using a Pelco easiGlow (Ted Pella) ...
-
bioRxiv - Molecular Biology 2020Quote: Quantifoil R2/2 holey carbon copper grids (Quantifoil Micro Tool) were prepared by first applying an additional thin layer of continuous carbon and then glow-discharging them for 15 sec at 15 mA using an easiGlow Discharge cleaning system (PELCO) ...
-
bioRxiv - Biochemistry 2021Quote: Quantifoil R2/2 holey carbon copper grids (Quantifoil Micro Tool) were prepared by applying an additional thin layer of continuous carbon ...
-
bioRxiv - Molecular Biology 2022Quote: ... either carbon on Cu/Rh (Quantifoil R2/2 200 mesh) or gold on gold UltrAuFoil R1.2/1.3 300 mesh ...
-
bioRxiv - Biochemistry 2022Quote: Standard holey carbon grids (Quantifoil, Cu 200 mesh, R2/2) were glow discharged for 30 s at 15 mA on the negative setting ...
-
bioRxiv - Immunology 2024Quote: Quantifoil R2/2 holey carbon copper grids (Quantifoil, Grosslöbichau, Germany) were cleaned by overnight incubation in ethyl acetate and coated with 1 nm continuous carbon foil by floatation ...
-
bioRxiv - Physiology 2021Quote: ... 3 µL of the vortexed dispersion were placed on glow discharged carbon-coated grids (Quantifoil, D) for 1 minute ...
-
bioRxiv - Biophysics 2023Quote: ... 3 μl of the sample was applied to a hydrophilized grids (Quantifoil, R1.2/1.3+2nm carbon) with an additional 2 nm layer of amorphous carbon ...
-
bioRxiv - Plant Biology 2023Quote: ... 3 μl protein was applied to glow-discharged carbon grids (Quantifoil Cu R1.2/1.3 300 mesh). Subsequently ...
-
bioRxiv - Biophysics 2024Quote: ... 3 μl sample were applied individually to electron microscopy grids (Quantifoil, 400 mesh Au 1.2/1.3) that were glow discharged for 40 s using Gatan SOLARUS ...
-
bioRxiv - Biochemistry 2024Quote: ... 3 µL of purified protein was applied to an UltrAuFoil® R 1.2/1.3 grid (Quantifoil) that had been glow-discharged for 1 minute and 45 seconds ...
-
bioRxiv - Biophysics 2024Quote: ... 3 µl of the solution was then added to a glow- discharged ultrafoil gold grid (Quantifoil 2/2 ...
-
bioRxiv - Biochemistry 2024Quote: ... 3 µL of the samples were applied to a holey carbon R3.5/1 Cu200 grid (Quantifoil) covered with a 2 nm continuous carbon foil ...
-
bioRxiv - Biophysics 2024Quote: ... 3 ul sample was applied onto glow-discharged R1.2/1.3 300 mesh UltrAuFoil gold grids (Quantifoil) (Russo and Passmore ...
-
bioRxiv - Biophysics 2024Quote: ... Four μl of this mixture was deposited to glow-discharged cryo-EM grids (UltrAuFoil R1.2/1.3, Quantifoil Cu 2/2, or Quantifoil AU 100 Holey carbon Films R2/1), blotted for 3 seconds at relative humidity 98% and temperature 4°C and plunge-frozen into liquid ethane (Vitrobot) ...
-
bioRxiv - Biophysics 2020Quote: ... 4 µl sample was applied to each freshly glow-discharged grid (Quantifoil, R1.2/1.3). The grids were then plunge-frozen in liquid ethane ...
-
bioRxiv - Microbiology 2021Quote: ... 4-7 µl of cells were deposited on R2/1 Cu 200 grids (Quantifoil) that had been glow-discharged for 1 min at 0.19 mbar and 20 mA in a PELCO easiGlow device shortly before use ...
-
bioRxiv - Biophysics 2021Quote: ... of purified CtenDNAV-II virons (10 mg ml-1) was deposited onto freshly glow-discharged holey carbon-coated copper grids (Quantifoil R 2/2, 300 mesh, copper) followed by 2 s of blotting in 100% relative humidity for plunge-freezing (Vitrobot Mark IV ...
-
bioRxiv - Biophysics 2020Quote: Quantifoil grids (200 mesh Au R2/2 and Au Finder; Quantifoil Micro Tools GmbH ...
-
bioRxiv - Cell Biology 2021Quote: R 2/1 Holey Carbon Au 200 mesh EM grids (Quantifoil) were coated with approximately 20 nm of carbon in a MED 020 carbon coater (BAL-TEC ...
-
bioRxiv - Microbiology 2022Quote: ... EM grids (R2/2, Cu 200 mesh; Quantifoil Micro Tools GmbH) were glow-discharged for 45 sec at 25 mA by PELCO easiGlow discharger ...
-
bioRxiv - Molecular Biology 2021Quote: ... UltrAuFoil (Russo and Passmore, 2014) R2/2 200 mesh grids (Quantifoil) were glow discharged for 15 s at 30 mA in a Quorum SC7620 ...
-
bioRxiv - Molecular Biology 2022Quote: ... The plus carbon sample (Quantifoil Cu300 R2/1 + 2 nm C) was blotted for 2 s with blot force +3 after a 30 s wait time after sample application and immediately plunge frozen in liquid ethane ...
-
bioRxiv - Biochemistry 2023Quote: ... Holey carbon R2/2 300 mesh grids (Quantifoil Micro Tools GmbH) were glow-discharged for 90 sec at 25 mA using a PELCO easiGlow glow discharge cleaning system ...
-
bioRxiv - Microbiology 2022Quote: ... Gold quantifoil R2/2 200 mesh grids (Quantifoil Micro Tools GmbH) were sterilised with 70% ethanol and placed in glass bottomed MatTek dishes (MatTek Corporation ...
-
bioRxiv - Microbiology 2024Quote: Cryo-EM gold grids (Quantifoil R2/2 Au 200 mesh, Quantifoil) were placed in the slots of a custom-made PDMS stencil (Alvéole ...
-
bioRxiv - Microbiology 2024Quote: Cryo-EM gold grids (Quantifoil R2/2 Au 200 mesh, Quantifoil) were placed in the slots of a custom-made PDMS stencil (Alvéole ...
-
bioRxiv - Biochemistry 2024Quote: Quantifiol R 1.2/1.3 Au 400 mesh 2 nm Carbon (Quantifoil) were glow discharged at 0.2 atm for 30 s and were loaded onto a FEI vitrobot (Thermo Fisher) ...
-
bioRxiv - Molecular Biology 2020Quote: 3 μL of sample was applied onto a holey carbon grid (Quantifoil, Cu, R1.2/1.3, 300 mesh) rendered hydrophilic by a 30 s glow-discharge in air (11 mA current with PIB-10) ...
-
bioRxiv - Plant Biology 2021Quote: Concentrated PSII solution (3 µl) was applied on glow-discharged holey carbon grids (Cu Quantifoil R1.2/1.3) that were vitrified for cryo-EM structural determination using a Vitrobot FEI (3 s blot at 4°C and 100% humidity) ...
-
bioRxiv - Molecular Biology 2022Quote: ... The sample (3 μL) was applied to freshly glow-discharged Au 300 mesh R1.2/1.3 grids (Quantifoil) in a Vitrobot Mark IV (FEI ...
-
bioRxiv - Biophysics 2021Quote: ... 3 μL was applied to Ultrafoil grids (R1.2/1.3, Au/Au, 300 mesh, Quantifoil Micro Tools GmbH) that had been glow-discharged for 2 min using a Pelco easiGlow (Ted Pella ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: Samples (3 µL) were applied to glow-discharged Quantifoil R1.2/1.3 Cu/Rh 200 mesh grids (Quantifoil) (M4R-Gi1-Ipx and M4R-Gi1-Ipx-LY298 ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 μl diluted protein sample was put on freshly glow-discharged Quantifoil R1.2/1.3 Cu grid (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Biophysics 2023Quote: ... 3 µL sample was applied to a freshly glow-discharged UltrAuFoil R1.2/1.3 300 mesh grids (Quantifoil), blotted with Whatman No ...
-
bioRxiv - Biochemistry 2023Quote: ... by applying 3 μL of it to plasma-cleaned 0.6/1 μm holey gold UltrAuFoil grids (Quantifoil). Following a 30 s incubation ...
-
bioRxiv - Biochemistry 2024Quote: Ternary complex sEGFR-Ex3HL/LH-CD3γε (3 µL) was applied to Quantifoil R1.2/1.3 Cu girds (Quantifoil) that had been glow discharged at 10 mA for 40 seconds with a sputter coater (JEOL JEC-3000FC) ...
-
bioRxiv - Biophysics 2024Quote: ... 3 μL were adsorbed to glow-discharged holey carbon-coated grids (Quantifoil 300 mesh, Cu R1.2/1.3). were then blotted for 3 to 6 s at 100% humidity (4 °C ...