Labshake search
Citations for Quantifoil Micro Tools :
151 - 200 of 784 citations for 4 Bromo 3' 1 3 dioxolan 2 yl 2 fluorobenzophenone since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Molecular Biology 2020Quote: ... at 13 °C and 100% humidity: 3 μl of sample were applied onto a freshly glow-discharged copper R2/1 300 mesh grid (Quantifoil), blotted for 8 s on both sides with blotting force −20 and plunge-frozen in liquid ethane.
-
bioRxiv - Biochemistry 2020Quote: ... A volume of 3 μL of the sample was applied to a glow-discharged grid (Quantifoil R2/1 300 mesh) at 25 °C and 90 % humidity ...
-
bioRxiv - Cell Biology 2021Quote: ... 3 µl of the samples at 1 µg/µl was applied to UltrAUfoil R1.2/1.3 grids (Quantifoil Micro Tools GmbH). Grids were glow-discharged for 30 sec at 15 mA prior to sample application (PELCO easiGlow™ ...
-
bioRxiv - Biochemistry 2022Quote: 2.8 µl of F-actin sample (3 – 16 µM) was pipetted onto a glow-discharged R2/1 Cu 300 mesh holey-carbon grid (Quantifoil). After incubating for 1 – 2 seconds ...
-
bioRxiv - Microbiology 2022Quote: ... using R2/2 200 mesh grids (Quantifoil) and imaged using a Talos 120 kV cryo-transmission electron microscope.
-
bioRxiv - Microbiology 2023Quote: R2/2 Cu 200 mesh grids (Quantifoil) were glow-discharged for 40 s at 2.7 mA ...
-
bioRxiv - Biochemistry 2023Quote: UltrAuFoil R2/2 Au200 mesh grids (Quantifoil) were glow discharged for 1 min on both sides at 25 mA using a Pelco easiGlow unit (Ted Pella ...
-
bioRxiv - Biochemistry 2024Quote: UltrAuFoil R2/2 Au300 mesh grids (Quantifoil) were glow discharged for 30 seconds on each side at 25 mA using a Pelco easiGlow unit (Ted Pella ...
-
bioRxiv - Cell Biology 2024Quote: ... or G200F1 R2/2 SiO2 grids (Quantifoil). The grids were glow discharged and coated with human fibronectin (FAL356008 ...
-
bioRxiv - Biochemistry 2022Quote: ... Before spotting onto R2/1 grids with an extra 2 nm carbon layer (Quantifoil, Inc), the complex was diluted to a final concentration of ∼100 nM and a 5-fold excess of Met-tRNAiMet ...
-
bioRxiv - Neuroscience 2022Quote: Holey copper or molybdenum EM grids (Quantifoil R 2/1 200 mesh; Quantifoil, Jena, Germany) were glow discharged (Harrick Plasma cleaner PDC-3XG ...
-
bioRxiv - Biochemistry 2024Quote: ... 3.5 µL were applied to freshly glow-discharged R 2/1 holey carbon grids (Quantifoil) at 4 °C and 95% humidity ...
-
bioRxiv - Cell Biology 2024Quote: ... Cells were seeded onto glow discharged cryo-EM grids (Quantifoil 2/1, 200 mesh, Au) overnight ...
-
bioRxiv - Biochemistry 2024Quote: ... 3.5 μl diluted T33-549 (final concentration ∼0.9 mg/ml) was applied to the glow-discharged surface of grids (QUANTIFOIL® R 2/2 on Cu 300 mesh + 2 nm C), then immediately plunged into liquid ethane after blotting for 4s with a blot force of 0 ...
-
bioRxiv - Biophysics 2023Quote: ... using FluoSpheres (diameter of 1 μm) on gold Quantifoil grids (200 mesh, R 2/1, holey SiO2 film; Quantifoil Micro Tools GmbH ...
-
bioRxiv - Cell Biology 2023Quote: ... Two μl of the diluted complex were applied to freshly glow-discharged R 2/2 holey carbon grids (Quantifoil), which were blotted with a force of 6 for 5 seconds and immediately vitrified by plunge-freezing in liquid ethane using a Vitrobot Mark IV (ThermoFisher ...
-
bioRxiv - Cell Biology 2022Quote: Cells were trypsinized and seeded onto 200 mesh gold holey carbon grids (R2/2-2 C, Quantifoil Micro Tools) placed in 3D printed grid holders (51 ...
-
bioRxiv - Bioengineering 2023Quote: ... a 200-mesh copper grid covered with a Quantifoil R 2/2 holey carbon film (Quantifoil Micro Tools GmbH) was surface plasma treated for 40 seconds using a Cressington 208 carbon coater ...
-
bioRxiv - Cell Biology 2023Quote: ... three microliters of EV sample were directly placed onto a glow–discharged 2/2 copper grid (Quantifoil, Jena, Germany). The excess sample was removed with 595 filter paper (Schleicher & Schuell ...
-
bioRxiv - Biochemistry 2024Quote: ... a freshly glow-discharged Cu300 R2/2 holey carbon grid with a 2-nm layer of amorphous carbon (Quantifoil) was mounted in the chamber of a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
Genome modularization reveals overlapped gene topology is necessary for efficient viral reproductionbioRxiv - Synthetic Biology 2020Quote: A 4 μL solution of co-isolated small particles were applied to glow-discharged copper grids (Quantifoil R2/2, Quantifoil Micro Tools), blotting for 3-seconds at 4 °C with 90% humidity and plunging into liquid ethane using a Lecia EM GP device (Leica Microsystems ...
-
Genome modularization reveals overlapped gene topology is necessary for efficient viral reproductionbioRxiv - Synthetic Biology 2020Quote: A 4 μL solution of co-isolated small particles were applied to glow-discharged copper grids (Quantifoil R2/2, Quantifoil Micro Tools), blotting for 3-seconds at 4 °C with 90% humidity and plunging into liquid ethane using a Lecia EM GP device (Leica Microsystems ...
-
Mycobacteria form viable cell wall-deficient cells that are undetectable by conventional diagnosticsbioRxiv - Microbiology 2022Quote: ... of which 3-4 µL was applied on glow-discharged 200 mesh copper grids with an extra thick R2/2 carbon film (Quantifoil Micro Tools). Vitrification was performed using an automated Leica EM GP plunge-freezer ...
-
bioRxiv - Biophysics 2024Quote: Approximately 3□μL of the sample solution were put on newly glow-discharged TEM grids (Quantifoil R2/1, Cu, mesh 200) and plunge-frozen in liquid ethane using the Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Biochemistry 2024Quote: Samples (3 μl) were applied onto a glow-discharged UltrAuFoil grid (Quantifoil GmbH) and were flash frozen in liquid ethane using the Vitrobot mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2022Quote: Samples (3 μl) were applied onto a glow-discharged UltrAuFoil grid (Quantifoil GmbH) and were flash-frozen in liquid ethane using the Vitrobot mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2024Quote: ... 3 µl) were deposited onto UltraAuFoil R1.2/1.3 300 gold mesh grids (QuantiFoil) that were plasma cleaned before use ...
-
bioRxiv - Biophysics 2022Quote: ... 3.6 μl were applied to glow-discharged gold holey carbon 2/1 300-mesh grids (Quantifoil). Grids were blotted for 4 s at 0 force and 1-s wait time before being vitrified in liquid propane using a Mark IV Vitrobot (Thermo Fisher Scientific) ...
-
bioRxiv - Immunology 2021Quote: ... was loaded onto plasma-cleaned Quantifoil R 2/1 (Cu, 400-mesh; Quantifoil Micro Tools GmbH) grids ...
-
bioRxiv - Immunology 2021Quote: Quantifoil finder grids (R2/1 or R2/2, Au 200 mesh grid, Quantifoil Micro Tools, Germany) were glow discharged with a 30 mA current for 30 s using Edwards Sputter Coater (S150B) ...
-
bioRxiv - Molecular Biology 2024Quote: ... For the 20S:AKIRIN2:IPO9 sample R3.5/1 200 mesh Cu prefloated with 2 nm Carbon (Quantifoil) were used for plunge freezing ...
-
bioRxiv - Molecular Biology 2020Quote: Samples were diluted to a concentration of 60-65 nM for the Pol II-U1 snRNP complex and 2 μl was applied to each side of the R2/2 UltrAuFoil grids (Quantifoil) that had been glow-discharged for 100 s ...
-
bioRxiv - Microbiology 2020Quote: ... 105 fluorescence-stained cells were deposited on the surface of Au-G200F1 finder grids coated with holey carbon (R 2/2; Quantifoil) and functionalized with Poly-L-Lysine (Merck ...
-
bioRxiv - Biophysics 2021Quote: ... 3.5 μL of sample were applied to glow-discharged 2/2 Quantifoil holey carbon grids (Quantifoil Micro Tools GmbH, Germany) and plunged frozen in liquid ethane with a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Cell Biology 2023Quote: ... 150 or 200 mesh gold holey carbon grids (R 2/2, #N1-C16nAu15-01 and #N1-C16nAu20-01, respectively) were purchased from Quantifoil Micro Tools and glow discharged for 2 min in an ELMO glow discharge unit (Agar Scientific ...
-
bioRxiv - Biochemistry 2022Quote: R2/2 holey carbon supported copper grids (Quantifoil) coated with a 2nm thin carbon layer were treated as described (A ...
-
bioRxiv - Biochemistry 2020Quote: ... QF AU-200 mesh R2/2 grids (Quantifoil) were glow-discharged and placed into a 6-well tissue culture plate well containing 2 mL of cell culture medium for at least 1 h before cell seeding ...
-
bioRxiv - Biochemistry 2023Quote: ... UltrAufoil Au 200 mesh R2/2 grids (Quantifoil) EM grids were glow-discharged on each side for 90 s at 30 sccm ...
-
bioRxiv - Microbiology 2022Quote: ... gold finder grids (Au NH2 R2/2, Quantifoil) containing infected amoebae were vitrified by back-blotting (Teflon ...
-
bioRxiv - Biophysics 2023Quote: ... 3 μl of medium containing one isolated muscle fibre was placed on the glow-discharged grid (Quantifoil R2/1 Au 200 mesh). After incubation for 60 seconds at 37 °C ...
-
bioRxiv - Biophysics 2022Quote: ... 10 µl sample was applied onto a glow discharged copper grid coated with holey carbon (R 2/2; Quantifoil, Jena, Germany), and subsequently dipped onto 500 µl deionized H2O for 1 second to clear the sucrose ...
-
bioRxiv - Biochemistry 2024Quote: ... of the freshly eluted complex peak solution (4.0 mg/mL) was loaded onto glow-discharged holey carbon grids (Quantifoil 2/2). The procedures for blotting and plunge freezing the grids were the same as above ...
-
bioRxiv - Microbiology 2023Quote: CryoEM samples were prepared by applying 5 μL aliquots of purified PLE PLPs to R2/2 Quantifoil grids and R2/2 Quantifoil grids coated with 2nm ultrathin Carbon (QUANTIFOIL®) that had been glow discharged for 45 seconds in a Pelco Easiglow glow discharging unit ...
-
bioRxiv - Cell Biology 2020Quote: All samples were imaged on carbon coated 3 mm gold EM finder grids (Quantifoil). Bead test and calibration samples were made by adding 2 µl of 175 nm fluorescent bead solution(Thermo Fisher PS-Speck) ...
-
bioRxiv - Cell Biology 2020Quote: ... and seeded onto a glow discharged holey carbon covered EM-grids (R 2/1, Au 200, Quantifoil). After approximately 16 h ...
-
bioRxiv - Microbiology 2023Quote: ... sample were placed onto glow-discharged Quantifoil R2/1 Cu300 holey carbon grids (1 µm spacing, 2 µm holes, copper mesh) (Quantifoil, Germany), blotted for 3.5 s before flash-freezing in liquid ethane using a Vitrobot mark IV (FEI ...
-
bioRxiv - Biophysics 2020Quote: ... 2.5 μl samples of GDN-purified proteins at a concentration of 1.5-3 mg ml−1 were applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3 or R0.6/1 Au 200 mesh). Excess liquid was removed in a controlled environment (4°C and 100% relative humidity ...
-
bioRxiv - Molecular Biology 2021Quote: ... 4 μl of protein sample (about 0.73 mg/ml) was applied onto a glow-discharged holey carbon grid (Quantifoil Au, R2/2, 300 mesh). After blotting for 3 s ...
-
bioRxiv - Biophysics 2021Quote: ... before applying 4 µL of the solution to a glow-discharged (30s at 35 mA) copper R 2/2 200-mesh holey carbon grid (Quantifoil Micro Tools). The grids were blotted manually from the back side with Whatman filter paper #1 for 2-4 s ...
-
bioRxiv - Molecular Biology 2023Quote: ... and samples for cryo-SPA were deposited onto 200-mesh holey carbon grids (Quantifoil Micro Tools, R 2/2 X-103-Cu200) which were first glow-discharged for 2.5 min using an ELMO glow discharge unit (Cordouan Technologies) ...