Labshake search
Citations for Quantifoil Micro Tools :
51 - 100 of 784 citations for 4 Bromo 3' 1 3 dioxolan 2 yl 2 fluorobenzophenone since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2022Quote: ... Samples were prepared by depositing 3 μl of the crystalline slurry onto a glow-discharged EM grid (Quantifoil, Cu 200 mesh, R2/2 holey carbon). Excess liquid was blotted away and the sample was vitrified using a Leica GP2 vitrification robot ...
-
bioRxiv - Microbiology 2020Quote: ... 3.5 μl of that mixture was transferred to a 3 mm freshly glow-discharged Quantifoil R2/2 Cu 300 mesh holey carbon grid (Quantifoil Micro Tools GmbH, Jena, Germany). Excess liquid was blotted away using a Leica EM GP plunge-freezer at room temperature and 80% humidity (blot time 2-3 sec ...
-
bioRxiv - Molecular Biology 2022Quote: ... The pellet was then resuspended in warm EM buffer and 3 μL of this sample was applied to a carbon on gold grid (Quantifoil R2/2 Au 200 mesh), recently glow-discharged for 1 min at 30 mA ...
-
bioRxiv - Molecular Biology 2020Quote: The grids were prepared by applying 4 µL of each complex at ∼70 nM to 400 mesh holey carbon Quantifoil 2/2 grids (Quantifoil Micro Tools). The grids were blotted for 1.5 sec at 4°C ...
-
bioRxiv - Biochemistry 2022Quote: ... holey copper grids (QUANTIFOIL R 2/2). 3.5-μl samples were adsorbed for 1 min at +20 °C ...
-
bioRxiv - Microbiology 2020Quote: Holey carbon-coated (R 2/2; Quantifoil) Au-G200F1 grids were analyzed in cryo-conditions by MISTRAL microscope at ALBA synchrotron ...
-
bioRxiv - Molecular Biology 2020Quote: QUANTIFOIL R 2/1 grids with the 2-nm carbon layer (Cu 200, Quantifoil Micro Tools) were glow discharged with 25 mA with negative polarity for 60 s in a PELCO easiGlow glow discharge unit ...
-
bioRxiv - Biophysics 2024Quote: ... 2 μL of 2 μM taxol-microtubules were incubated on a glow-discharged holey carbon cryo-EM grid (QuantiFoil, Cu 300 R 2/1) for 30 seconds ...
-
bioRxiv - Immunology 2024Quote: ... 3 µL aliquots were applied to UltrAuFoil gold R0.6/1 grids (Quantifoil) and subsequently blotted for 6 seconds at blot force 0 ...
-
bioRxiv - Biochemistry 2020Quote: ... 3 µl of sample were applied to glow-discharged Quantifoil Au 2/2 holey carbon 200 mesh grids or Ultrafoil Au 2/2 holey gold 200 mesh grids (Quantifoil), and flash frozen in liquid ethane using an FEI Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Molecular Biology 2023Quote: A QuantiFoil 300-mesh R 2/2 grid with 2 nm continuous carbon (QuantiFoil Micro Tools GmbH ...
-
bioRxiv - Biochemistry 2020Quote: UltrAUfoil 2/2 300 mesh gold grids (Quantifoil) were used for open hole data collection (Dataset 1) ...
-
bioRxiv - Biochemistry 2023Quote: ... A 3 µL drop was applied to a glow-discharged (PELCO easiGlow, 15 mA, 2 min) holey carbon grid (Quantifoil R1.2/1.3 on gold 200 mesh support), blotted for 3-4 seconds with Whatman Grade 595 filter paper (GE Healthcare) ...
-
bioRxiv - Biophysics 2020Quote: ... or QUANTIFOIL R 2/2 holey carbon grids (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Microbiology 2024Quote: ... copper EM grids (Cu 200 R 2/1, Quantifoil) were used ...
-
bioRxiv - Biophysics 2022Quote: ... holey carbon grid coated with 2 nm ultrathin carbon film (Quantifoil 300-mesh, R 2/2). After waiting for 60 s ...
-
bioRxiv - Molecular Biology 2021Quote: ... 3.5 μL was applied to a glow-discharged Quantifoil copper grid with 2 nm continuous carbon support over holes (Quantifoil R 2/4 400 mesh), blotted ...
-
bioRxiv - Biophysics 2022Quote: UltraAUfoil R1.2/3 (Quantifoil Micro Tools GmbH) grids were glow-discharged on both sides for 30 s at 15 mA using a Pelco Easiglow ...
-
bioRxiv - Cell Biology 2024Quote: 3 µl cell suspension was applied on glow-discharged (Pelco easiGlow) R1/4 SiO2 gold 200 mesh grids (Quantifoil), blotted for 10 sec from the backside and plunge-frozen on a Leica EM GP2 plunger at 23 °C ...
-
bioRxiv - Biochemistry 2021Quote: Holey grids (gold, 200 mesh, r 2/2 by Quantifoil) were glow-discharged for 30 seconds using a Pelco glow discharge system ...
-
bioRxiv - Biophysics 2024Quote: Holey carbon grids (Quantifoil Au R 2/2, 200 mesh) were glow-discharged with easiGlow at 20 mA for 45 s ...
-
bioRxiv - Molecular Biology 2020Quote: ... 4 μl sample was applied onto Quantifoil grid Rh/Cu 200 R2/2 (Quantifoil, Inc), and was flash frozen into liquid ethane using a Vitrobot (FEI ...
-
bioRxiv - Cell Biology 2021Quote: ... 4 µl sample was applied onto Quantifoil grid Cu/Rh 200 R2/2 (Quantifoil, Inc), and was flash frozen into liquid ethane using a Vitrobot (FEI ...
-
bioRxiv - Biochemistry 2022Quote: ... 3 μL of sample was applied to 200-mesh copper R2/1 grids (Quantifoil), which were glow-discharged twice using a Pelco EasyGlow instrument ...
-
bioRxiv - Molecular Biology 2022Quote: ... 3 μl sample was applied to 1.2/1.3 or 0.6/1 UltrAuFoil grids (Quantifoil) (Russo and Passmore ...
-
bioRxiv - Biophysics 2023Quote: 3 μL of sample was applied on glow-discharged Au200 R2/1 grids (Quantifoil), and the excess liquid was removed by blotting for 4 s (blot force 3 ...
-
bioRxiv - Microbiology 2023Quote: ... 3 μL of 3 mg/mL of protein was added to glow discharged UltrAuFoil holey gold grid (Quantifoil GmbH) using a Vitrobot Mark IV (Thermofisher ...
-
bioRxiv - Biochemistry 2024Quote: ... was used to apply the purified samples (3.5 µl) to freshly glow discharged R3/3 holy copper grids supported with 3 nm continuous carbon (Quantifoil). The samples were incubated for 45 s on the grids at 4 °C and 95% humidity ...
-
bioRxiv - Biochemistry 2024Quote: Grids for cryo-EM were prepared by applying 4 µL of sample on a glow-discharged Quantifoil 300 mesh Cu 2/1 grid (Quantifoil Micro Tools), blotting for 7.5 seconds ...
-
bioRxiv - Biophysics 2021Quote: 4 µL of purified HsPepT1 at 2 mg/mL was applied to a glow discharged gold holey carbon 2/1 300-mesh grid (Quantifoil). The grid was blotted for 4 s at 0 force before being plunge vitrified in liquid propane using a Mark IV Vitrobot (ThermoFisher) ...
-
bioRxiv - Biophysics 2023Quote: ... split onto Poly-D-Lysine coated R 2/2 grids (QUANTIFOIL 100 Holey Carbon Films ...
-
bioRxiv - Immunology 2024Quote: ... The sample was prepared on Quantifoil Cu 300 2/2 (Quantifoil) grids and was frozen in liquid ethane using the Vitroblot Mark IV (Thermo Fisher ...
-
bioRxiv - Biophysics 2023Quote: ... glow discharged QUANTIFOIL® copper R 2/2 grid with a 2 nm thin extra carbon layer (QUANTIFOIL, GMBH) was used ...
-
bioRxiv - Biophysics 2024Quote: ... samples that have been analyzed here are Influenza A/Hong Kong/1/1968 virions that are produced from MDCK cells grown directly on cryoEM grids (QF AU200 R 2/2, Quantifoil, Germany), infected at a multiplicity of infection <1 ...
-
bioRxiv - Biochemistry 2021Quote: ... Quantifoil Cu 300 mesh (R 2/2 geometry; Quantifoil Micro Tools GMBH) covered with a thin layer of 3 nm carbon were used for the for the GTPBP5KO sample ...
-
bioRxiv - Molecular Biology 2022Quote: ... 4 μL of the cells were applied to a glow-discharged 200 mesh holey carbon grid copper grid (Quantifoil R1.2/3) and vitrified in a liquid ethane on a Vitrobot Mark IV (Thermo Scientific ...
-
bioRxiv - Cell Biology 2021Quote: R 2/1 Holey Carbon Au 200 mesh EM grids (Quantifoil) were coated with approximately 20 nm of carbon in a MED 020 carbon coater (BAL-TEC ...
-
bioRxiv - Molecular Biology 2022Quote: ... The plus carbon sample (Quantifoil Cu300 R2/1 + 2 nm C) was blotted for 2 s with blot force +3 after a 30 s wait time after sample application and immediately plunge frozen in liquid ethane ...
-
bioRxiv - Biochemistry 2022Quote: R2/2 grids (Quantifoil) were covered with a thin layer of continuous carbon (estimated to be 50 Å thick ...
-
bioRxiv - Microbiology 2024Quote: ... Continuous carbon grids (Quantifoil R 2/2 on Cu 300 mesh grids + 2 nm Carbon, Quantifoil Micro Tools C2-C16nCu30-01) were glow-discharged for 5 sec in an easiGlow Glow Discharge Cleaning System (Ted Pella Inc.) ...
-
bioRxiv - Biochemistry 2022Quote: ... Continuous carbon grids (Quantifoil R 2/2 on Cu 300 mesh grids + 2 nm Carbon, Quantifoil Micro Tools C2-C16nCu30-01) were glow-discharged for 5 sec in an easiGlow Glow Discharge Cleaning System (Ted Pella Inc.) ...
-
bioRxiv - Cell Biology 2024Quote: EM support grids (Au grids 200 mesh, carbon or SiO2 foil, R2/2 or R1/4, Quantifoil) were glow discharged with a Pelco easiGlow for 90 sec at 15 mA ...
-
bioRxiv - Biochemistry 2024Quote: ... 3 µL of the samples were applied to a holey carbon R3.5/1 Cu200 grid (Quantifoil) covered with a 2 nm continuous carbon foil ...
-
bioRxiv - Molecular Biology 2022Quote: ... Glow-discharged carbon coated gold mesh grids (QF 2/2 AU 200, Quantifoil) were placed on the edge of the glass microscopy slides ...
-
bioRxiv - Bioengineering 2022Quote: ... holey carbon grids (Ultrafoil 25 nM Au R 2/2 200 mesh; Quantifoil) were glow-discharged for 10 s using the Solarus plasma cleaner (Gatan) ...
-
bioRxiv - Biochemistry 2023Quote: ... Cryo-EM grids (carbon-coated Quantifoil R 2/2 cupper grids, 300 mesh) were plunge-frozen using a Vitrobot IV (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2023Quote: ... the same proteins were applied to holey grids with a 2 nm carbon film (Quantifoil Cu 2/2 200 mesh from EMS). Samples were frozen after a total of 145 min on the grids without carbon film and 150 min on the grids with carbon film ...
-
bioRxiv - Biochemistry 2022Quote: KRASGTPase/BRAFWT/MEK1SASA/14-3-3 complex in SEC buffer was applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3, 400 mesh) and vitrified using a Leica EM GP ...
-
bioRxiv - Microbiology 2024Quote: ... Sample volumes of 3.5 µl (8 OD260 per ml) were applied to grids (Quantifoil, Cu, 300 mesh, R3/3 with 3 nm carbon) which had been freshly glow-discharged using a GloQube (Quorum Technologies ...
-
bioRxiv - Biochemistry 2024Quote: Sample volumes of 3.5 μl (8 OD260 per ml) were applied to grids (Quantifoil, Cu, 300 mesh, R3/3 with 3 nm carbon) which had been freshly glow-discharged using a GloQube (Quorum Technologies ...