Labshake search
Citations for Quantifoil Micro Tools :
101 - 150 of 216 citations for N BOC 3 FLUORO L TYROSINE since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biophysics 2023Quote: ... 3 μL of sample was applied to a freshly glow-discharged UltrAuFoil R1.2/1.3 300 mesh grids (Quantifoil), blotted for 1.5 – 2.0 s ...
-
bioRxiv - Immunology 2023Quote: ... 3 μL of the purified complex (8 mg/ml) was deposited onto a glow-discharged holey grid (Quantifoil Au 300 mesh R1.2/1.3 ...
-
bioRxiv - Biochemistry 2023Quote: ... A sample volume of 3 μL sample was applied to a freshly glow-discharged UltrAuFoil R1.2/1.3 300 mesh (Quantifoil); the sample was incubated for 1min and blotted with Whatman No ...
-
bioRxiv - Microbiology 2024Quote: ... 3 µL aliquots were applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3 300 mesh, Ted Pella) and incubated for 10 s before automated blotting and flash-freezing in liquid ethane with a Vitrobot Mark IV vitrification system (Thermo Fisher Scientific) ...
-
bioRxiv - Biophysics 2024Quote: ... 3 µL of the mixture was then applied to glow-discharged 1.2/1.3 300 mesh Cu grids (Quantifoil). For the detergent sample at pH 9 ...
-
bioRxiv - Microbiology 2020Quote: Usually 5 μL of liquid culture (OD680 ~ 0.3) was pipetted onto holey carbon-coated copper grids (R2/1, 200 mesh, Quantifoil Micro Tools, Jena, Germany). The grids were blotted from the reverse side and immediately plunged into the liquid ethane at liquid nitrogen temperature atmosphere using a Vitrobot ...
-
bioRxiv - Cell Biology 2022Quote: ... A 3 µl volume of the Kif5B suspension was first deposited at the surface of a glow-discharged holey carbon grid (Quantifoil R2/2, Cu200) in the temperature (23 °C ...
-
bioRxiv - Microbiology 2022Quote: ... 3 μl aliquots of the mixture was applied to R2/2 200 mesh copper Quantiofoil grids (Quantifoil Micro Tools) that were freshly glow discharged ...
-
bioRxiv - Biochemistry 2019Quote: ... 3 μl were applied onto freshly glow-discharged Quantifoil Cu/Rh R2/2 holey carbon 200 mesh grids (Quantifoil). The grids were blotted for 4 seconds with a blotting force of −15 ...
-
bioRxiv - Biophysics 2021Quote: ... aliquots (3 μL) of the concentrated protein were placed on glow-discharged holey carbon grids (Quantifoil Au R1.2/1.3) and blotted for 5 s ...
-
bioRxiv - Microbiology 2021Quote: ... 3 µl of sample were applied to a freshly glow-discharged Quantifoil Au R2/2 200 mesh grid (Quantifoil), blotted for 5.5-7.5 s (0.5 s drain time ...
-
bioRxiv - Microbiology 2021Quote: ... 3 µl of sample were applied to a freshly glow-discharged Quantifoil Au R2/2 200 mesh grid (Quantifoil), blotted for 3.5-7.5 s (0.5 s drain time ...
-
bioRxiv - Biophysics 2022Quote: Cryo-EM grids were prepared by applying 3 μL of protein to a glow-discharged QuantiAuFoil R1.2/1.3 300-mesh grid (Quantifoil, Germany) and blotted for 2.5 to 4 s under 100% humidity at 4 °C before plunging into liquid ethane using a Mark IV Vitrobot (FEI).
-
bioRxiv - Biochemistry 2020Quote: ... 3 μL of eluate (72 nM) was applied to a plasma-treated UltraAuFoil 1.2/1.3 grid (Quantifoil, Großlöbichau, Germany). The grids were hand blotted for 3 sec from the backside of the grid before being plunged into liquefied ethane.
-
bioRxiv - Biochemistry 2019Quote: ... 3 ul of sample were applied to glow-discharged holey carbon-coated grids (Quantifoil 300 mesh, Au R1.2/1.3), adsorbed for 5 s ...
-
bioRxiv - Biophysics 2022Quote: ... the pelleted cells resuspended in 100 μl NaH2PO4-NaOH pH 7.5 and a 3 μl drop adsorbed for 20 s to a carbon-coated copper grid (300 mesh, Quantifoil) that had been glow-discharged for 30 s at a current of 25 mA ...
-
bioRxiv - Microbiology 2022Quote: ... Purified BfpD was diluted to 4.5 mg/ml and 3 µl was applied to a glow-discharged 300 mesh UltraAufoil -1.2/1.3 holey-gold (Quantifoil, Germany). Grids were blotted for 2 s with ash-free Whatman® Grade 540 filter paper in a Vitrobot Mark IV (ThermoFisher Scientific ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... All samples were pipetted at a volume of 3 µL onto UltrAufoil R1.2/1.3 300 mesh holey grids (Quantifoil, Germany) which had been glow discharged in air at 15 mA for 180 s using a Pelco EasyGlow ...
-
bioRxiv - Biophysics 2023Quote: ... 3 μL HA trimer (0.75 mg/ml) was applied to holey carbon grid (Quantifoil 400 mesh Au R1.2/1.3) which was glow discharged 30 s at 15 mA ...
-
bioRxiv - Biophysics 2023Quote: ... 3 μL apoferritin (0.67 mg/ml) was loaded on the holey carbon grids (Quantifoil 400 mesh Cu R1.2/1.3) which was glow discharged for 30s ...
-
bioRxiv - Biophysics 2023Quote: ... 3 μL HA trimer (0.75 mg/ml) was applied to holey carbon grid (Quantifoil 400 mesh Cu R1.2/1.3) which was glow discharged 30 s at 15 mA ...
-
bioRxiv - Bioengineering 2024Quote: About 3 μl droplets emulsion were applied onto glow-discharged holey carbon grids (Quantifoil Cu R1.2/1.3, 300 mesh), blotted with a Vitrobot Marker IV (Thermo Fisher Scientific ...
-
bioRxiv - Cell Biology 2022Quote: ... 4 µL of the mixture were pipetted onto a copper EM grid with holey carbon film (R2/2, 200 mesh, Quantifoil Micro Tools GmbH, Q43486) that had been freshly glow-discharged for 30 s at -30 mAmp ...
-
bioRxiv - Biochemistry 2022Quote: ... 3.5 μL of purified CB1-Gi complex at 12 mg/ml was applied on glow- discharged holey carbon gold grids (Quantifoil R1.2/1.3, 200 mesh) at room temperature (for AM11517) ...
-
Cryo-EM structure of a eukaryotic zinc transporter at a low pH suggests its Zn2+-releasing mechanismbioRxiv - Biochemistry 2022Quote: ... and 3 μl of the protein solution was applied to glow-discharged (45 s) Quantifoil R2/1 300-mesh gold grids (Quantifoil Micro Tools GmbH, Germany). The grids were blotted with standard Vitrobot filter paper for 2.5 s at 4 °C under 100% humidity and plunged into liquid ethane using a Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Biochemistry 2022Quote: ... 3 μL of purified CB1-Gi complex at 15 mg/ml was applied on glow- discharged holey carbon gold grids (Quantifoil R1.2/1.3, 200 mesh). The grids were blotted using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Neuroscience 2023Quote: A volume of 3 µl purified complex at a concentration of 1.5 mg/ml was applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3 Cu 200 mesh). The grids were blotted with a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Molecular Biology 2020Quote: ... at 13 °C and 100% humidity: 3 μl of sample were applied onto a freshly glow-discharged copper R2/1 300 mesh grid (Quantifoil), blotted for 8 s on both sides with blotting force −20 and plunge-frozen in liquid ethane.
-
bioRxiv - Pathology 2019Quote: ... of the purified MNV infectious particles and HNV GII.3 VLP were placed onto R 1.2/1.3 Quantifoil grids (Quantifoil Micro Tools) coated with a thin carbon membrane that were glow-discharged using a plasma ion bombarder (PIB-10 ...
-
bioRxiv - Biophysics 2020Quote: ... and urine were applied in 3 µl-volumes onto glow-discharged Quantifoil Au R2/2 holey carbon 300 mesh grids (Quantifoil). Grids were blotted for 2.0 s and plunged into liquid ethane cooled by liquid nitrogen ...
-
bioRxiv - Biochemistry 2020Quote: ... A volume of 3 μL of the sample was applied to a glow-discharged grid (Quantifoil R2/1 300 mesh) at 25 °C and 90 % humidity ...
-
bioRxiv - Microbiology 2021Quote: ... 3 μL were applied onto a Cu grid with a holey carbon film (Quantifoil R 2/2; Quantifoil, Jena, Germany), blotted ...
-
bioRxiv - Microbiology 2021Quote: ... 3 μL were applied onto a Cu grid with a holey carbon film (Quantifoil R 2/2; Quantifoil, Jena, Germany), blotted ...
-
bioRxiv - Pharmacology and Toxicology 2021Quote: Samples (3 μL) were applied to a glow-discharged UltrAufoil R1.2/1.3 300 mesh holey grid (Quantifoil GmbH, Großlöbichau, Germany) and were flash frozen in liquid ethane using the Vitrobot mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Cell Biology 2021Quote: ... 3 µl of the samples at 1 µg/µl was applied to UltrAUfoil R1.2/1.3 grids (Quantifoil Micro Tools GmbH). Grids were glow-discharged for 30 sec at 15 mA prior to sample application (PELCO easiGlow™ ...
-
bioRxiv - Microbiology 2022Quote: ... 3 mm gold EM finder grids with a perforated carbon film (R 2/2, 200 mesh) were purchased from Quantifoil (AU G200F1 finder ...
-
bioRxiv - Biochemistry 2022Quote: 2.8 µl of F-actin sample (3 – 16 µM) was pipetted onto a glow-discharged R2/1 Cu 300 mesh holey-carbon grid (Quantifoil). After incubating for 1 – 2 seconds ...
-
bioRxiv - Immunology 2022Quote: ... 3 μL of the mixture was applied to a glow-discharge holey carbon grids (Quantifoil, Cu 200 mesh, R1.2/1.3). The grid was blotted for 4.5 s in 100% humidity before being flash frozen in liquid ethane by using a Vitrobot Mark IV (Thermo Fisher) ...
-
bioRxiv - Molecular Biology 2020Quote: 3.5 µl of the concentrated sample were applied to glow discharged copper grids with holey carbon support and a 2 nm continuous carbon layer (R3/3, Quantifoil). Grids were blotted in a Vitrobot Mark IV (FEI Company ...
-
bioRxiv - Microbiology 2021Quote: ... An aliquot (3 μl) of this mixture was applied to a glow-discharged holey carbon grid (QF R2/2 Cu, QUANTIFOIL), blotted with Whatman® No ...
-
bioRxiv - Immunology 2023Quote: ... 3 μL of the purified complex were loaded onto a glow-discharged holey grid (Quantifoil Au 300 mesh R1.2/1.3), and subsequently were plunge-frozen in liquid ethane using Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Cell Biology 2024Quote: ... 3 µl of cell suspension was applied to a freshly grown discharged holey carbon grid (Quantifoil® #200, R2/2). Grids were immediately blotted from the back side using Whatman filter paper #1 (GE Healthcare ...
-
bioRxiv - Cell Biology 2023Quote: ... An aliquot of 3 ul cell suspension was applied to the glow-discharged holey carbon-coated copper (R 2/1, 200 mesh) (Quantifoil) and blotted for 9 seconds by Leica GP2 (Leica Microsystems) ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 µL of each sample was applied to glow-discharged (PELCO easiGlow, 15 mA, 2 min) holey carbon grid (Quantifoil R1.2/1.3 on gold or copper 200 mesh support) ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... 3 μl of the samples were applied to glow-discharged holey carbon EM grids (Quantifoil 300 copper mesh, R1.2/1.3) in an EM-GP2 plunge freezer (Leica) ...
-
bioRxiv - Immunology 2023Quote: ... 3 μL of each LNP sample was deposited onto a holey carbon grid that was glow-discharged (Quantifoil R1.2/1.3) and vitrificated using a Vitrobot Mark IV System (FEI/Thermo Scientific ...
-
bioRxiv - Biochemistry 2024Quote: ... 3 μL of hexapeptide sample were applied to glow-discharged Quantifoil R 2/2 grids (Quantifoil Micro tools GmbH, Germany), blotted for 1 second ...
-
bioRxiv - Molecular Biology 2022Quote: 3 μL of ~120 nM mitoribosome was applied onto a glow-discharged (20 mA for 30 sec) holey-carbon grid (Quantifoil R2/2, copper, mesh 300) coated with continuous carbon (of ~3 nm thickness ...
-
bioRxiv - Microbiology 2019Quote: ... Four μl of this mixture was applied onto freshly glow-discharged copper R2/2 of th0 Quantifoil holey carbon grids (Quantifoil Micro Tools GmbH, Jena, Germany). Using an FEI Vitrobot Mark IV ...
-
bioRxiv - Biochemistry 2023Quote: 3 μL of ∼120 nM mitoribosome was applied onto a glow-discharged (20 mA for 30 sec) holey- carbon grid (Quantifoil R2/2, copper, mesh 300) coated with continuous carbon (of ∼3 nm thickness ...