Labshake search
Citations for Covaris :
401 - 450 of 558 citations for DNA Sequencer since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Genomics 2019Quote: ... 100 ng of DNA in 130 μL of elution buffer was sheared on a S2 focused ultrasonicator (Covaris) for 65 seconds using intensity = 4 ...
-
bioRxiv - Microbiology 2020Quote: ... Genomic DNA was sheared to an average of 550 bp fragments using an M220 ultrasonicator (Covaris, Wolburn, MA). Libraries were prepared by using a TruSeq DNA PCR-Free Library Preparation kit (Illumina ...
-
bioRxiv - Microbiology 2020Quote: For Illumina sequencing genomic DNA was sheared into 400–600 base pair (bp) fragments by focused ultrasonication (Covaris Adaptive Focused Acoustics technology ...
-
bioRxiv - Molecular Biology 2022Quote: ... The DNA was quantitated using the Qubit® 2.0 Fluorometer and then sheared on a Covaris E220 (Covaris) to ∼500 bp ...
-
bioRxiv - Microbiology 2022Quote: ... DNA samples were then sheared to about 400 bp fragments using the E220 Focused ultrasonicator (Covaris, Woburn, MA), and libraries were prepared with Hyper prep kit (Kapa Biosystems ...
-
bioRxiv - Microbiology 2021Quote: ... And then DNAs were cleaved into 50∼800 bp fragments by the Covaris E220 ultrasonicator (Covaris, Brighton, UK) and some fragments between 150∼250 bp were selected using AMPure XP beads (Agencourt ...
-
bioRxiv - Genomics 2020Quote: ... approximately 1 μg of genomic DNA was acoustically sheared to ∼200 bp using a M220 Focused-ultrasonicator (Covaris). Sheared DNA was end repaired ...
-
bioRxiv - Microbiology 2022Quote: ... Genomic DNA samples (3 µg) were sheared to an average size of 12 kb via G-tube (Covaris) before library preparation ...
-
bioRxiv - Microbiology 2019Quote: ... 10 μg genomic DNA was sheared to 20 kb fragments by g-tubes (Covaris, Inc., Woburn, MA, USA) according to the manufacturer’s instructions ...
-
bioRxiv - Genetics 2019Quote: ... DNA was sheared to a targeted average size of 20 kb using G-tubes (Covaris, Woburn, MA, U.S.A.) according to the manufacturer’s instructions ...
-
bioRxiv - Cell Biology 2019Quote: ... DNA (3 μg) was sonicated at intensity 4 for 200 cycles per burst for 55 s (Covaris S2), and DNA fragments were end-repaired ...
-
bioRxiv - Zoology 2021Quote: The following ultrasound fragmentation of the total genomic DNA was implemented using Covaris S220 focused ultrasonicator instrument (Covaris). The resulting fragmented DNA was purified and concentrated using paramagnetic bead-based chemistry AMPure XP (Beckman-Coulter ...
-
bioRxiv - Microbiology 2020Quote: ... The good-quality DNA was first sheared randomly to fragments of around 500bp by Focused-ultrasonicattor (Covaris M220) and used for metagenomic library preparation with TruSeq® Nano DNA LT Sample Prep Kit (Illumina ...
-
bioRxiv - Genomics 2019Quote: ... Genomic DNA from FACS-sorted cells was randomly sheared to 100-500 bp in a microtube (Covaris; 520045) using a Covaris S220 device (400 sec ...
-
bioRxiv - Plant Biology 2020Quote: ... One microgram of genomic DNA from individual samples was fragmented using a Covaris S220 instrument (Covaris Inc, USA) and resulting DNA fragments were purified with AMPure XP reagent (Beckman Coulter ...
-
bioRxiv - Genomics 2021Quote: One microgram of genomic DNA from the lymphoblastoid Coriell-NA12878 cell line was sheared using g-Tube (Covaris) to obtain high molecular weight fragments ranging from 50kb to 160 kb ...
-
bioRxiv - Genomics 2021Quote: ... Genomic DNA was sheared to an average size of 300 bp with an M220 ultrasonicator (Covaris, Woburn, MA). Sheared DNA samples were used for paired-end indexed library construction using an Ovation Ultralow library systems V2 kit (NuGEN ...
-
bioRxiv - Genomics 2021Quote: 200 ng of genomic DNA was spiked with 1% unmethylated Lambda gDNA and fragmented to 400 bp (Covaris S220 ...
-
bioRxiv - Genomics 2021Quote: ... 100 ng of DNA was fragmented to an average size of 350 bp by ultrasonication (Covaris ME220 ultrasonicator). DNA sequencing libraries were prepared using dual-index adapters with the TruSeq Nano DNA Library Prep kit (Illumina ...
-
bioRxiv - Genomics 2021Quote: ... 100 ng of DNA was fragmented to an average size of 350 bp by ultrasonication (Covaris ME220 ultrasonicator). DNA sequencing libraries were prepared using dual-index adapters with the TruSeq Nano DNA Library Prep kit (Illumina ...
-
bioRxiv - Microbiology 2022Quote: DNA for each sample was sheared to about 300 bp using the Covaris ME220 (Covaris, Woburn, MA, USA). The shotgun sequencing library was constructed using the KAPA Hyper Prep Kit (Roche) ...
-
bioRxiv - Genomics 2022Quote: The extracted DNA for genome assembly was sheared into 20 kb fragments using g-TUBE (Covaris, MA, USA) and converted into 20 kb SMRTbell template libraries ...
-
bioRxiv - Cancer Biology 2023Quote: ... Genomic and tissue DNA was sonicated into fragments of 150 base pairs using a M220TM Focused-ultrasonicator (Covaris) and library preparation performed using NEBNext® FFPE DNA Repair Mix (New England Biolabs® Inc ...
-
bioRxiv - Microbiology 2023Quote: ... genomic DNA isolated from the transposon pool was sheared to ∼300 bp using a Covaris S2 Ultrasonicator (Covaris), custom adapters (Table S1 ...
-
bioRxiv - Genomics 2023Quote: ... genomic DNA was disrupted randomly with 6 kb-20 kb fragments by g-TUBE (Covaris, Woburn, MA, USA) and sequenced by the PacBio Sequel platform ...
-
bioRxiv - Cancer Biology 2023Quote: ... Genomic DNAs were randomly broken into specific short fragments with a length of about 350 bp by Covaris ultrasonic crusher ...
-
bioRxiv - Genetics 2022Quote: ... genomic DNA (2□μg) was diluted in 200 μL of elution buffer and fragmented using g-TUBE (Covaris) by centrifuging at 2400×g for 2□min ...
-
bioRxiv - Genomics 2023Quote: ... The DNA was sheared to 10–30 Kb using a Covaris g-TUBE (Covaris, Inc, Woburn, MA, USA), purified ...
-
bioRxiv - Genomics 2024Quote: DNA samples were sheared to an average size of ∼ 15 kb using the G-tube protocol (Covaris, MA). DNA libraries were prepared using a SMRTbell express template prep kit 2.0 (100-938-900 ...
-
bioRxiv - Molecular Biology 2024Quote: ... Purified DNA was further fragmented to the size of ∼150 bp by the Covaris focused-ultrasonicator (Covaris M220) and subjected to library preparation using the NEBNext Ultra II DNA Library Prep Kit for Illumina (NEB ...
-
bioRxiv - Evolutionary Biology 2021Quote: ... 500ng of DNA was sheared to a 150-700 bp range using the Covaris® E210 (Covaris, Inc., USA). Sheared DNA was used for Illumina® library preparation with a semi-automated protocol ...
-
bioRxiv - Genomics 2020Quote: ... and the cell suspension was sonicated for 1.5-2h until DNA was in the size range of 100-500bp using the Covaris S220 system (Covaris, Peak Power ...
-
bioRxiv - Microbiology 2020Quote: ... DNA was sheared to an average length of approximately 10-20 kb using g-TUBEs (Covaris; Woburn, MA, USA) and SMRTbell template sequencing libraries were prepared using sheared DNA ...
-
bioRxiv - Plant Biology 2022Quote: ... 1 µg DNA from each genotype was fragmented to ~500 bp size using the Covaris S2 (Covaris, MA, USA). The fragmented DNA was purified using 0.6X AMPure® XP beads (Beckman Coulter ...
-
bioRxiv - Genomics 2022Quote: ... HMW-DNA (120 ng/µl) was sheared two times (back and forth) with a gTUBE (Covaris; P/N 520079) in a Eppendorf™ Centrifuge 5424 at 4800 rpm (soft ...
-
bioRxiv - Genomics 2022Quote: ... and the DNA was sheared to a target size of 200-400 bp by a Covaris sonicator (Covaris, M220). DNA between 100-400 bp was selected for using AMPure XP beads (Beckman Coulter) ...
-
bioRxiv - Genomics 2019Quote: ... A PE library was constructed from one of the seven sub-samples (120 individuals, 1μg DNA) sheared by ultrasonication (Covaris) company ...
-
bioRxiv - Genomics 2019Quote: ... One microgram of genomic DNA per sample was fragmented into 180-280bp fragments by hydrodynamic shearing (Covaris, Massachusetts, USA). After the reparation of the 3’ and 5’ ends and the adenylation of the 3’ ends ...
-
bioRxiv - Genomics 2020Quote: DNA was sheared down to 200 base pairs (bp) using Adaptive Focused Acoustics on the Covaris E220 (Covaris Inc) following manufacturer recommendations with the following modifications ...
-
bioRxiv - Genetics 2020Quote: ... Single index libraries of 23 F1 isolates were generated by sonicating DNA to ∼ 220 bp (Covaris, Woburn, MA, USA), cleaning and concentrating (1 part DNA ...
-
bioRxiv - Molecular Biology 2021Quote: ... DNA was sheared to ~15-20kb by spinning through a Covaris g-TUBE (Covaris Inc., Woburn, MA, Cat #520079) at 4200 rpm for 1 min ...
-
bioRxiv - Genomics 2019Quote: ... and the DNA was sheared to a target size of 200-400 bp by a Covaris sonicator (Covaris, M220). DNA between 100-400 bp was selected for using AMPure XP beads (Beckman Coulter) ...
-
bioRxiv - Evolutionary Biology 2021Quote: ... We then fragmented the quantified DNA by sonication using Covaris LE220 ultrasonicator and Covaris microTUBE (#520053, Covaris® Inc.) to obtain a final insert size of 250–350 bp ...
-
bioRxiv - Cancer Biology 2020Quote: ... in function of available material 0.1 to 1.0 microgram of genomic DNA was sheared on a Covaris™ LE220-Plus (Covaris). The fragmented DNA was further size-selected for the fragment size of 220-550bp with Agencourt AMPure XP beads (Agencourt ...
-
bioRxiv - Developmental Biology 2021Quote: ... Purified genomic DNA (with 5% mouse DNA and 0.5% lambda DNA spike-in) was sheared to 200 - 500 bp fragments using a M220 Focused-ultrasonicator (Covaris). Bisulfite-converted DNA libraries with methylated adapters were enriched using an in-house anti-CMS antibody bound to protein A/G Dynabeads ...
-
bioRxiv - Microbiology 2019Quote: ... The purified DNA was fragmented to ~400 bp with the aid of an M220 focused-ultrasonicator (Covaris, Woburn, USA) and subsequently used for library preparation using a TruSeq™ DNA Sample Prep Kit (Illumina ...
-
bioRxiv - Genomics 2021Quote: DNA was sheared down to 200 base pairs (bp) using Adaptive Focused Acoustics on the Covaris E220 (Covaris Inc) following manufacturer recommendations with 10 μL Low EDTA TE buffer supplemented with 5 μL of truSHEAR buffer using a microTUBE-15 ...
-
bioRxiv - Genomics 2022Quote: ... Genomic DNA was sheared either by six centrifugations at 1,600 × g in the g-Tube (Covaris, Woburn, MA, USA) or in Megaruptor 2 (Deagenode ...
-
bioRxiv - Microbiology 2022Quote: ... DNA was subjected to acoustic shearing to obtain fragment sizes of approximately 300 bp using g-Tube (Covaris, USA). We adopted and modified the TraDIS protocol published by Barquist et al ...
-
bioRxiv - Molecular Biology 2022Quote: ... The input and the immunoprecipitated DNAs were fragmented to an average size of approximately150 bp by ultra-sonication (Covaris). The fragmented DNAs were end-repaired ...