Labshake search
Citations for New Objective :
351 - 400 of 547 citations since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cancer Biology 2021Quote: ... fused silica picofrit capillary tubing (New Objective). The analytical column was heated to 50 °C using an AgileSLEEVE column heater (Analytical Sales and Services ...
-
bioRxiv - Immunology 2021Quote: ... Peptides were separated on a 450 mm analytical column (8 μm tip, 75 μm inner diameter, PicoTipTMEmitter, New Objective) packed with ReproSil-Pur C18 (1.9 μm particles ...
-
bioRxiv - Immunology 2021Quote: ... Peptides were fractionated by reverse-phase HPLC on a 75 μm x 15 cm PicoFrit column with a 15 μm emitter (New Objective) in-house packed with Magic C18AQ (Michrom BioResources ...
-
bioRxiv - Microbiology 2021Quote: ... The peptides were loaded onto a C18 PicoFrit column (C18 PepMap, 75 µm id × 10 cm, 3.5 µm particle size, 100 Å pore size; New Objective, Ringoes, NJ, USA) and separated with a gradient from 100% mobile phase A (0.1% FA ...
-
bioRxiv - Cell Biology 2021Quote: ... Peptide mixtures were separated on a self-packed C18 (1.9 um Dr. Maisch, Germany) fused silica column (25 cm x 75 μM internal diameter; New Objective, Woburn, MA) by a NanoAcquity UHPLC (Waters ...
-
bioRxiv - Cell Biology 2021Quote: ... 10 μm tip (New Objective). The mass spectrometer was operated in positive ion mode ...
-
bioRxiv - Cell Biology 2021Quote: ... trapped the peptides prior to separation on PicoChip Column: 75um ID x 15um tip packed with 105mm 3um Reprosil-PUR C18-AQ 120A (New Objective). Peptides were eluted with an acetonitrile gradient ...
-
bioRxiv - Genomics 2021Quote: ... Peptide elution occurred over a linear acetonitrile gradient (3-35%) for 140 minutes directly into a UHR-qTOF mass spectrometer (Impact II, Bruker) using a pico-emitter tip (New Objective FS360–20-10-D-20, Woburn, MA). Samples were run in batches using Hystar 4.1 (Bruker) ...
-
bioRxiv - Molecular Biology 2021Quote: ... The nanoUPLC was coupled online through a nanoESI emitter (10 μm tip; New Objective; Woburn, MA, USA) to a quadrupole orbitrap mass spectrometer (Q Exactive Plus ...
-
bioRxiv - Cell Biology 2020Quote: ... equipped with PicoView nanoflow (New Objective) ion source ...
-
bioRxiv - Systems Biology 2020Quote: ... Peptides were separated on 50-cm columns (New Objective) with an inner diameter of 75 μm packed in house with 1.9 μm C18 resin (Dr ...
-
bioRxiv - Cell Biology 2020Quote: ... which was 14 cm × 75 μm PicoFrit Emitter with 15 μm tip (New Objective) self-packed with 1.7 μm Aeris C18 material (Phenomenex) ...
-
bioRxiv - Cell Biology 2020Quote: ... The analytical column was connected to a SilicaTip emitter (New Objective) with a 10 µm tip orifice and coupled to a Q Exactive Plus mass spectrometer (Thermo Fisher Scientific ...
-
bioRxiv - Cell Biology 2020Quote: ... and a trap (IntegraFrit Capillary, 100 µm ID, New Objective) containing Magic C18 AQ 200Å (2 cm) ...
-
bioRxiv - Cell Biology 2020Quote: ... and a trap (IntegraFrit™ Capillary, 100 µm ID, New Objective) containing Magic C18 AQ 200Å (2 cm) ...
-
bioRxiv - Cell Biology 2020Quote: ... The LC system configured in a vented format (72) consisted of a fused-silica nanospray needle (PicoTip™ emitter, 75 µm ID, New Objective) packed in-house with Magic C18 AQ 100 Å reverse-phase media (Michrom Bioresources Inc. ...
-
bioRxiv - Cell Biology 2020Quote: ... Approximatly 0.5 μg of peptides were loaded on a 50 cm HPLC column (75 μm inner diameter, New Objective; in-house packed using ReproSil-Pur C18-AQ 1.9 lm silica beads ...
-
bioRxiv - Cell Biology 2020Quote: ... peptides were loaded onto 75 µm x 15 cm fused silica capillaries (New Objective) packed with C18AQ resin (Reprosil-Pur 120 ...
-
bioRxiv - Cell Biology 2020Quote: ... or distal coated Silica Tips (FS360-20-10-D, New Objective, Woburn, USA; LTQ-Orbitrap) and externally calibrated using standard compounds ...
-
bioRxiv - Microbiology 2020Quote: ... and 0.1% (v/v) formic acid) after direct injection onto a 20µm PicoFrit emitter (New Objective) packed to 12cm with Strata-X C18 AQ 3µm 120 Å stationary phase ...
-
bioRxiv - Developmental Biology 2020Quote: ... we used PicoFrit fused silica capillary columns (15 cm x 75 µm i.d; New Objective, Woburn, MA) with C-18 reverse-phase material and high pressure packing cells (Jupiter 5 µm particles ...
-
bioRxiv - Molecular Biology 2020Quote: ... The analytical column was a fused silica capillary (75 µm × 35 cm) with an integrated PicoFrit emitter (New Objective) packed in-house with Reprosil-Pur 120 C18-AQ 1.9 µm resin (Dr ...
-
bioRxiv - Molecular Biology 2020Quote: ... Peptides were ionized using a Picotip emitter nanospray needle (New Objective). Each mass spectrometry (MS ...
-
bioRxiv - Molecular Biology 2020Quote: ... Reverse-phase chromatography was performed at 50 °C over a 25 cm IntegraFrit column (IF360–75-50-N-5, New Objective, Woburn, MA) packed in-house with 1.9 μm ReproSil-Pur C18-AQ (Dr ...
-
bioRxiv - Molecular Biology 2020Quote: ... and nanoelectrospry ion source (New Objective, Inc., Woburn, MA). Samples in 0.1% formic acid were injected onto a self-packed precolumn (150 μm I.D ...
-
bioRxiv - Molecular Biology 2020Quote: ... 75-μm-internal-diameter PicoFrit column (New Objective) packed in-house to a length of 50 cm with 1.9 μm ReproSil-Pur 120 Å C18-AQ (Dr ...
-
bioRxiv - Molecular Biology 2020Quote: ... The column was mounted on a DPV ion source (New Objective) connected to an Orbitrap Fusion mass spectrometer (Thermo Scientific) ...
-
bioRxiv - Molecular Biology 2020Quote: ... mounted on a DPV ion source (New Objective). They were measured with a Orbitrap Fusion (Thermo Scientific ...
-
bioRxiv - Molecular Biology 2020Quote: ... Peptides were loaded on capillary columns (PicoFrit, 30 cm × 150 μm ID, New Objective) self-packed with ReproSil-Pur 120 C18-AQ ...
-
bioRxiv - Molecular Biology 2020Quote: ... mounted on a DPV ion source (New Objective) connected to a Orbitrap Fusion (Thermo Scientific) ...
-
bioRxiv - Molecular Biology 2020Quote: ... A proxeon nanoelectrospray source set at 1800 V and a 75 µm (with 10 µm orifice) fused silica nano-electrospray needle (New Objective, Woburn, MA) was used to complete the interface ...
-
bioRxiv - Microbiology 2020Quote: ... Samples were directly loaded onto a PicoFrit column (New Objective, Woburn, MA) packed in house with ReproSil-Pur C18AQ 1.9 um resin (120A° pore size ...
-
bioRxiv - Microbiology 2020Quote: ... equipped with a PicoView Ion Source (New Objective) and coupled to an EASY-nLC 1000 (Thermo Scientific) ...
-
bioRxiv - Biochemistry 2020Quote: ... using coated emitter tips (New Objective) was used for ionization ...
-
bioRxiv - Microbiology 2020Quote: ... Peptides were loaded on capillary columns (PicoFrit, 30 cm × 150 μm ID, New Objective) self-packed with ReproSil-Pur 120 C18-AQ ...
-
bioRxiv - Cancer Biology 2020Quote: ... Bruker-Michrom) in-line with a nano-capillary column (Picofrit, 75 μm i.d.x 15 μm tip, New Objective) packed in-house with 10 cm of MAGIC AQ C18 reverse phase material (Michrom Bioresource) ...
-
bioRxiv - Cancer Biology 2020Quote: ... The peptide samples were injected onto a capillary column (Picofrit with 10μm tip opening / 75μm diameter, New Objective, PF360–75-10-N-5) packed in-house with 20cm C18 silica material (1.9 μm ReproSil-Pur C18-AQ medium ...
-
bioRxiv - Systems Biology 2020Quote: ... Peptide mixtures were separated on a self-packed C18 (1.9 μm, Dr. Maisch, Germany) fused silica column (25 cm x 75 μM internal diameter; New Objective, Woburn, MA) by a NanoAcquity UHPLC (Waters ...
-
bioRxiv - Systems Biology 2020Quote: ... The solution (2 µl) was loaded onto a self-packed 1.9 µm ReproSil-Pur C18 (Dr. Maisch) analytical column (New Objective, 50 cm × 75 µm inner diameter ...
-
bioRxiv - Systems Biology 2020Quote: ... column (New Objective, PF360-75-10-N-5) in-house packed with 1.9-µm C18 beads (Dr ...
-
bioRxiv - Systems Biology 2020Quote: ... Peptides were directly eluted (online) into a UHR-qTOF mass spectrometer (ImpactHD, Bruker) using a pico-emitter tip (New Objective FS360–20-10-D-20, Woburn, MA). Batch-processing of samples was controlled with Hystar 4.1 (Bruker ...
-
bioRxiv - Cancer Biology 2020Quote: ... using an in-house packed 20cm x 75μm diameter C18 column (1.9μm Reprosil-Pur C18-AQ beads; Picofrit 10μm opening, Dr. Maisch GmbH (New Objective)) ...
-
bioRxiv - Cell Biology 2020Quote: ... which was coupled to the column with a customized nano-spray EASY-Spray ion-source (Thermo-Fisher) using coated emitter tips (New Objective).
-
bioRxiv - Plant Biology 2020Quote: ... equipped with a Digital PicoView source (New Objective) and coupled to a M-Class UPLC (Waters) ...
-
bioRxiv - Neuroscience 2020Quote: ... The sample was injected from a cooled autosampler onto a 10 cm long fused silica tip column (SilicaTips, New Objective, USA) packed in-house with 1.9 μm C18-AQ ReproSil-Pur (Dr ...
-
bioRxiv - Neuroscience 2020Quote: ... The electrospray source was fitted with an emitter tip 10μm (New Objective, Woburn, MA) and maintained at 1.5 kV electrospray voltage ...
-
bioRxiv - Cell Biology 2020Quote: ... using a glass capillary emitter (PicoTip: New Objective, Woburn, MA, USA), as described previously35.
-
bioRxiv - Systems Biology 2020Quote: ... and buffer B (2% water and 0.1% formic acid in acetonitrile) through an analytical column (75 μm × 20 cm) and a fused silica PicoTip emitter (New Objective, Woburn, MA, USA) with 3-μm 200 Å Magic C18 AQ resin (Michrom BioResources ...
-
bioRxiv - Bioengineering 2020Quote: Peptides were sprayed into the MS through an uncoated fused-silica PicoTip(tm) emitter (360 µm O.D., 20 µm I.D., 10 ± 1.0 µm tip I.D., New Objective). The source parameters were set as follows ...
-
bioRxiv - Bioengineering 2020Quote: ... The cross-linked peptides were loaded onto a Picochip column (C18, 3 μm particle size, 300 Å pore size, 50 μm × 10.5 cm; New Objective) and eluted using a 60 min LC gradient ...