Labshake search
Citations for New Objective :
201 - 250 of 547 citations since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cancer Biology 2022Quote: ... using a self-packed PicoFrit column (New Objective, Woburn, MA, USA; 75 µm × 50 cm length) self-packed with ReproSil-Pur 120A C18-Q 1.9 µm resin (Dr ...
-
bioRxiv - Cell Biology 2022Quote: Peptides were loaded onto 250 mm × 75 µm PicoFrit (C18, 2 µm medium) analytical columns (New Objective) at a maximum pressure of 800 bar ...
-
bioRxiv - Cell Biology 2022Quote: ... The analytical column was a 75 um x 10.5 cm PicoChip column packed with 3 um ReproSil-Pur® beads (New Objective, Inc. Woburn, MA). The flow rate was kept at 300nL/min ...
-
bioRxiv - Cancer Biology 2022Quote: ... Sonation) to heat up the nano column (PicoFrit, 100 μm x 250 mm x 15 μm tip, New Objective) for peptide separation ...
-
bioRxiv - Cell Biology 2022Quote: ... Peptides were separated on a 20 cm fused silica emitter (New Objective) packed in-house with reverse-phase Reprosil Pur Basic 1.9 mm (Dr ...
-
bioRxiv - Developmental Biology 2022Quote: ... equipped with a Digital PicoView source (New Objective) and coupled to a nanoAcquity UPLC (Waters Inc.) ...
-
bioRxiv - Plant Biology 2022Quote: ... The sample was injected into a Thermofisher Scientific Orbitrap ELITE mass spectrometer via a PicoTip Emitter (SilicaTip, 30 µM, New Objective) at a flow rate of 0.4 µl·min-1 at 1.5-1.8 kV ...
-
bioRxiv - Plant Biology 2022Quote: ... Ionization (1.5 kV ionization potential) was performed with liquid junction and a non-coated capillary probe (10 μm inner diameter; New Objective). Peptide ions were analyzed using Xcalibur 2.07 with the following data-dependent acquisition steps ...
-
bioRxiv - Neuroscience 2022Quote: ... Chromatography for peptide separation was performed using increasing organic proportion of acetonitrile (5-40% (v/v)) over a 120 min gradient) on a self-packed analytical column using PicoTip™ emitter (New Objective, Woburn, MA) using Reprosil Gold 120 C-18 ...
-
bioRxiv - Neuroscience 2022Quote: ... Peptide eluents were separated on a self-packed C18 (1.9 μm, Dr. Maisch) fused silica column (25 cm × 75 μM internal diameter, New Objective) by a Dionex UltiMate 3000 RSLCnano liquid chromatography system (Thermo Fisher Scientific ...
-
bioRxiv - Immunology 2022Quote: ... Peptides were separated on a 450-mm analytical column (8-μm tip, 75-μm inner diameter, PicoTip emitter, New Objective) packed with ReproSil-Pur C18 (1.9-μm particles ...
-
bioRxiv - Microbiology 2022Quote: ... Peptides were directly injected onto an analytical column (360 µm O.D. x 75 µm I.D.) with an integrated emitter (New Objective) that was packed with 25 cm of ReproSil Pur C18 AQ 1.9 µm particles (Dr ...
-
bioRxiv - Zoology 2022Quote: ... The eluted samples were sprayed through a charged emitter tip (PicoTip Emitter, New Objective, 10 ± 1 µm) into Orbitrap Fusion MS system (Thermo Fisher Scientific) ...
-
bioRxiv - Microbiology 2022Quote: ... were injected via autosampler onto a 25 cm × 75 μM ID reversed phase column packed with 3 μM Reprosil (New Objective, Boston, MA). Peptides were separated and eluted with a gradient from 2 to 32% acetonitrile in 0.1% formic acid over 70 min at 300 nL/min into an LTQ Orbitrap XL hybrid mass spectrometer (Thermo Fisher Scientific ...
-
bioRxiv - Microbiology 2022Quote: ... fused silica emitters 100 mm long with a 75 μm internal diameter (New Objective) packed in-house using a pressurized (35 to 40 bars of helium ...
-
bioRxiv - Synthetic Biology 2022Quote: ... 75-μm-internal-diameter PicoFrit column (New Objective) packed in-house to a length of 50 cm with 1.9 μm ReproSil-Pur 120 Å C18-AQ (Dr ...
-
bioRxiv - Plant Biology 2022Quote: ... The analytical column outlet was directly connected to the Digital PicoView 550 (New Objective) ion source with sheath gas option and SilicaTip emitter (New Objective ...
-
bioRxiv - Plant Biology 2022Quote: ... ion source with sheath gas option and SilicaTip emitter (New Objective; FS360-20-15-N-20-C12) utilization ...
-
bioRxiv - Neuroscience 2022Quote: ... equipped with a Digital PicoView source (New Objective) and coupled to a M-Class UPLC (Waters) ...
-
bioRxiv - Neuroscience 2022Quote: ... Eluting peptides were electrosprayed at 2.4 kV into an Orbitrap-Lumos-Fusion mass spectrometer through a 1 μm emitter tip (New Objective). Survey scans (MS1 ...
-
bioRxiv - Plant Biology 2022Quote: ... The analytical column was a fused silica capillary (75 μm × 32 or 36 cm) with an integrated PicoFrit emitter (New Objective) packed in-house with Reprosil-Pur 120 C18-AQ 1.9 μm resin (Dr ...
-
bioRxiv - Molecular Biology 2022Quote: ... The nanoUPLC was coupled online through a nanoESI emitter (10μm tip; New Objective, Woburn, MA, USA) to a quadrupole orbitrap mass spectrometer (Q Exactive HF ...
-
bioRxiv - Plant Biology 2022Quote: ... Peptides were fractionated on a fused silica HPLC-column tip (I.D. 75 μm, New Objective, self-packed with ReproSil-Pur 120 C18-AQ ...
-
bioRxiv - Microbiology 2022Quote: ... Peptides were separated over a 50 cm analytical column (Picofrit, 360 µm O.D., 75 µm I.D., 10 µm tip opening, non-coated, New Objective) that was packed in-house with Poroshell 120 EC-C18 ...
-
bioRxiv - Physiology 2022Quote: ... 75 μm internal diameter PicoFrit analytical column (New Objective) packed with 1.9 μm ReproSil-Pur 120 C18-AQ media (Dr ...
-
bioRxiv - Microbiology 2022Quote: ... Afterwards the peptides were eluted at 100 nL/min in a 90 minutes extended gradient from 10-40% acetic acid solvent (in 95% acetonitrile) to a 20-cm IntegraFrit column (50 μm inner diameter, Reprosil-Pur C18-AQ 3 μm, New Objective, Woburn, USA). The acquired spectra were analyzed using Thermo Proteome Discoverer in combination with Mascot (ThermoFisher Scientific ...
-
bioRxiv - Cancer Biology 2022Quote: ... Peptides were separated on a 20 cm fused silica emitter (New Objective) packed in-house with reverse-phase Reprosil Pur Basic 1.9 μm (Dr ...
-
bioRxiv - Microbiology 2022Quote: ... 6 cm of 10 μm C18) and a self-pack 5 μm tip analytical column (15 cm of 5 μm C18, New Objective) over a 150 min gradient before nanoelectrospray using a QExactive mass spectrometer (ThermoFisher) ...
-
bioRxiv - Biochemistry 2022Quote: ... with an integrated PicoTip emitter (New Objective) using a 2 hr LC gradient ...
-
bioRxiv - Cell Biology 2022Quote: ... 75 μm internal diameter PicoFrit analytical column (New Objective) packed with 1.9 μm ReproSil-Pur 120 C18-AQ media (Dr ...
-
bioRxiv - Genomics 2022Quote: ... 10 µm tip (New Objective) and a spray voltage of 2.2 kV was applied ...
-
bioRxiv - Molecular Biology 2022Quote: ... using an electrospray ionization nano source and distally coated SilicaTip emitters (New Objective, Woburn, MA, USA) at a spray voltage of 1.4 kV ...
-
bioRxiv - Plant Biology 2022Quote: ... Peptides were separated on 16 cm frit-less silica emitters (New Objective, 75 μm inner diameter), packed in-house with reversed-phase ReproSil-Pur C18 AQ 1.9 μm resin ...
-
bioRxiv - Biochemistry 2022Quote: ... The 75 um x 15 cm column (PicoFrit Self pack emitter, New Objective) was in house packed with ReproSIL-Pur-120-C18-AQ (3 μm ...
-
bioRxiv - Immunology 2022Quote: Peptides were resuspended in 0.1% formic acid and 3% directly injected on a 75 μm ID column (New Objective) packed with 25 cm of Reprosil C18 3 μm ...
-
bioRxiv - Biochemistry 2022Quote: ... peptides were separated using 100 μm ID × 15 cm length PicoTip™ EMITTER columns (New Objective) filled with ReproSil-Pur C18-AQ reverse-phase beads (3 μm ...
-
bioRxiv - Biochemistry 2022Quote: ... and then separated onto a 16 cm long silica capillary (Silica Tips FS 360-75-8, New Objective, MA, United States), packed in-house with a C18 ...
-
bioRxiv - Immunology 2022Quote: ... Peptides were separated over a 50 cm analytical column (Picofrit, 360 µm O.D., 75 µm I.D., 10 µm tip opening, non-coated, New Objective) that was packed in-house with Poroshell 120 EC-C18 ...
-
bioRxiv - Cell Biology 2022Quote: For BioID: The desalted and eluted peptides were loaded on an in-house packed C18 column (New Objective, 25 cm long, 75 µm inner diameter) for reverse-phase chromatography ...
-
bioRxiv - Cell Biology 2022Quote: For proteome: The desalted and eluted peptides were loaded on an in-house packed C18 column (New Objective, 50 cm long, 75 µm inner diameter) for reverse-phase chromatography ...
-
bioRxiv - Cell Biology 2022Quote: ... were separated on a self-packed C18 (1.9 μm Dr. Maisch, Germany) fused silica column (25 cm × 75 μm internal diameter; New Objective) by a Easy-nLC 1200 and monitored on a Fusion Lumos mass spectrometer (ThermoFisher Scientific) ...
-
bioRxiv - Cancer Biology 2022Quote: ... The analytical PicoFrit column contained an integrated uncoated pre-cut emitter (Silica Tip, 10 μm tip inner diameter, New Objective). The mass spectrometer was operated in selected reaction monitoring (SRM ...
-
bioRxiv - Cancer Biology 2022Quote: ... Elution was performed using a 50 cm fused silica emitter (New Objective) packed in-house with ReproSil-Pur C18-AQ ...
-
bioRxiv - Cancer Biology 2022Quote: ... Switzerland) and an analytical column (Selfpack PicoFrit column, 35 cm length, 75 μm ID, New Objective, Woburn, MA) both in-house packed with C18 particles (Dr ...
-
bioRxiv - Biophysics 2021Quote: ... Nano-electrospray ionization was achieved using a coated fused silica emitter (New Objective) biased to 2 kV ...
-
bioRxiv - Cancer Biology 2021Quote: ... PicoFrit column (New Objective, Woburn, MA) self-packed with Agilent Poroshell 120S ES-C18 ...
-
bioRxiv - Cancer Biology 2021Quote: ... The NanoSpray III source of the mass spectrometer was fitted with a 10 μm inner diameter PicoTip emitter (New Objective). The mass spectrometer was operated in positive ion mode using Analyst TF1.6 software (Sciex ...
-
bioRxiv - Cancer Biology 2021Quote: ... About 1 μg of peptides was loaded on a 20◻cm analytical HPLC◻column (75 μm ID PicoTip fused silica emitter (New Objective); in◻house packed using ReproSil◻Pur C18◻AQ 1.9◻μm silica beads (Dr Maisch GmbH)) ...
-
bioRxiv - Genetics 2021Quote: ... Online LC separation was carried out using a 75 µm x 25 cm fused silica IntregraFrit capillary column (New Objective, Woburn, MA) packed in-house with 1.9 µm Reprosil-Pur C18 AQ reverse-phase resin (Dr ...
-
bioRxiv - Genetics 2021Quote: ... Online LC separation was carried out using a 75 µm x 25 cm fused silica PicoTip capillary column (New Objective, Woburn, MA) packed in-house with 1.9 µm Reprosil-Pur C18 AQ reverse-phase resin (Dr ...